| 1 |
.TH LPR 1 2006-12-09 "LPRng" "lpr command" |
| 2 |
.SH NAME |
| 3 |
lpr \- off line print |
| 4 |
.SH SYNOPSIS |
| 5 |
.B lpr |
| 6 |
[ |
| 7 |
.B \-A |
| 8 |
] |
| 9 |
[ |
| 10 |
.B \-B |
| 11 |
] |
| 12 |
[ |
| 13 |
.B \-b,l |
| 14 |
] |
| 15 |
[ |
| 16 |
.BI \-C " class" |
| 17 |
] |
| 18 |
[ |
| 19 |
.BI \-D " debugopt" |
| 20 |
] |
| 21 |
.ti +5n |
| 22 |
[ |
| 23 |
.BI \-F " filterformat" |
| 24 |
] |
| 25 |
[ |
| 26 |
.B \-G |
| 27 |
] |
| 28 |
[ |
| 29 |
.B \-h |
| 30 |
] |
| 31 |
[ |
| 32 |
.BI \-i " indentcols" |
| 33 |
] |
| 34 |
.ti +5n |
| 35 |
[ |
| 36 |
.B \-k |
| 37 |
] |
| 38 |
[ |
| 39 |
.BI \-J " job" |
| 40 |
] |
| 41 |
[ |
| 42 |
.BI \-K,# " copies" |
| 43 |
] |
| 44 |
.ti +5n |
| 45 |
[ |
| 46 |
.BI \-m " mailTo" |
| 47 |
] |
| 48 |
[ |
| 49 |
.BI \-P " printer" |
| 50 |
] |
| 51 |
[ |
| 52 |
.B \-r |
| 53 |
] |
| 54 |
.ti +5n |
| 55 |
[ |
| 56 |
.BI \-R " remoteAccount" |
| 57 |
] |
| 58 |
[ |
| 59 |
.B \-s |
| 60 |
] |
| 61 |
[ |
| 62 |
.BI \-T " title" |
| 63 |
] |
| 64 |
[ |
| 65 |
.BI \-U " user" |
| 66 |
] |
| 67 |
.ti +5n |
| 68 |
[ |
| 69 |
.B \-V |
| 70 |
] |
| 71 |
[ |
| 72 |
.BI \-w " width" |
| 73 |
] |
| 74 |
[ |
| 75 |
.BI \-X " userfile" |
| 76 |
] |
| 77 |
[ |
| 78 |
.B \-Y |
| 79 |
] |
| 80 |
[ |
| 81 |
.BI \-Z " options" |
| 82 |
] |
| 83 |
[ |
| 84 |
.BI \-1,2,3,4 " font" |
| 85 |
] |
| 86 |
[ |
| 87 |
.B \-\- |
| 88 |
] |
| 89 |
.ti +5n |
| 90 |
[ |
| 91 |
.IR filename " \|.\|.\|." |
| 92 |
] |
| 93 |
.SH DESCRIPTION |
| 94 |
.B Lpr |
| 95 |
uses a spooling daemon to print the named files when facilities |
| 96 |
become available. If no names appear, the standard input is assumed. |
| 97 |
.SH OPTIONS |
| 98 |
.TP 5 |
| 99 |
.B \-A |
| 100 |
The authentication type is set by the value of the AUTH environment variable. |
| 101 |
.TP 5 |
| 102 |
.B \-B |
| 103 |
Do filtering of job files by the filters specified by the printcap. |
| 104 |
Combine the output of the filtering operation into a single job file and then |
| 105 |
send the single file to the lpd print spooler. |
| 106 |
.TP 5 |
| 107 |
.B "\-b, \-l" |
| 108 |
either of these flags specifies a |
| 109 |
binary or literal file, |
| 110 |
and no (or minimal) processing is to be done by the print spooling system. |
| 111 |
Printed using the |
| 112 |
.I f |
| 113 |
format filter (:if=... or :filter=...). |
| 114 |
.TP 5 |
| 115 |
.BI \-C " class" |
| 116 |
Specify the job classification for use on the burst page and to |
| 117 |
set the priority. |
| 118 |
Priorities range from A (lowest) to Z (highest); |
| 119 |
the default priority is A. |
| 120 |
For example, |
| 121 |
.br |
| 122 |
.ti +0.5i |
| 123 |
lpr \-C B foo.c |
| 124 |
.br |
| 125 |
sets the priority/class to B and the file foo.c is printed. |
| 126 |
.TP 5 |
| 127 |
\fB\-D\fP\ \fIdebugoptions\fP |
| 128 |
Debugging is controlled using the |
| 129 |
.B \-D |
| 130 |
option. This accepts a comma-separated list of debugging |
| 131 |
settings. These settings take one of two forms: |
| 132 |
.BI facility =value, |
| 133 |
or |
| 134 |
.B value |
| 135 |
to set an overall default value. |
| 136 |
.TP 5 |
| 137 |
\fB\-F\fI filterformat\fR |
| 138 |
Filter or format specification. |
| 139 |
By default, |
| 140 |
input is assumed to a standard text file and the |
| 141 |
.I f |
| 142 |
format is used; |
| 143 |
the output device is assumed to be a simple line printer. |
| 144 |
Other formats available are listed below. |
| 145 |
Not all formats may be available on all printers; |
| 146 |
see |
| 147 |
.BR printcap (5) |
| 148 |
for details. |
| 149 |
Formats are single lower case letters; |
| 150 |
the following are the valid arguments for |
| 151 |
.B \-F |
| 152 |
together with the assumed type of data. |
| 153 |
For compatibility with previous versions of |
| 154 |
.BR lpr , |
| 155 |
the format types can be used as options themselves |
| 156 |
(i.e. by omitting the |
| 157 |
.BR F ) |
| 158 |
except where noted below, |
| 159 |
a warning may be issued in such cases. |
| 160 |
.\".RS 5 |
| 161 |
.TP 5 |
| 162 |
\fB\-G\fP |
| 163 |
Similar to the |
| 164 |
\fB\-B\fP option, |
| 165 |
but only processes individual files. |
| 166 |
.TP 5 |
| 167 |
\fB\-h\fP |
| 168 |
No banner or header for this job. |
| 169 |
.TP 5 |
| 170 |
.BI \-i " indentcols" |
| 171 |
Indent input by indentcols. |
| 172 |
Note that this option is not supported on all printers. |
| 173 |
.TP 5 |
| 174 |
.BI -J " jobname" |
| 175 |
Specify the job name to print on the burst page; |
| 176 |
defaults to the name of files in the job or |
| 177 |
.I "(STDIN)" |
| 178 |
if input is from a pipe. |
| 179 |
.TP 5 |
| 180 |
\fB\-K\fP\fIcopies\fP,\0\fB\-#\fP\fIcopies\fP |
| 181 |
Specify the number of copies of each file to be printed. |
| 182 |
You may or may not get the requested number of copies depending on the |
| 183 |
intelligence of the remote printing system. |
| 184 |
.TP 5 |
| 185 |
.B \-k |
| 186 |
.B lpr |
| 187 |
normally creates a temporary file |
| 188 |
for the input read from stdin before sending it to the remote |
| 189 |
printer. |
| 190 |
The |
| 191 |
.B \-k |
| 192 |
(kut-through) option |
| 193 |
will simply copy from STDIN to the destination print spooling system. |
| 194 |
If you kill the job in the middle of creation |
| 195 |
then the partly transferred file will get printed. |
| 196 |
This option may not work with very large jobs, |
| 197 |
non-LPRng spoolers, |
| 198 |
or |
| 199 |
when you have encryption or authentication enabled. |
| 200 |
.TP 5 |
| 201 |
.BI \-m " mailTo" |
| 202 |
Send mail upon unsuccessful completion to user |
| 203 |
.IR mailTo . |
| 204 |
The mailTo value has been used to do such things as |
| 205 |
specify email (user@host), paging (page:user@host), |
| 206 |
both (user@host,page:user@host) |
| 207 |
and all sorts of other notifier information. |
| 208 |
See the LPRng HOWTO for details on how this is implemented. |
| 209 |
.TP 5 |
| 210 |
.BI \-P " printer" |
| 211 |
By default, |
| 212 |
the destination printer |
| 213 |
is taken from |
| 214 |
the command line |
| 215 |
.I "-P printer" |
| 216 |
value, |
| 217 |
then |
| 218 |
the environment variables |
| 219 |
PRINTER, |
| 220 |
LPDEST, |
| 221 |
NPRINTER, |
| 222 |
NGPRINTER, |
| 223 |
then first entry in the printcap information, |
| 224 |
and and finally the default_printer entry from the |
| 225 |
configuration file, |
| 226 |
and then the compile time default. |
| 227 |
.TP 5 |
| 228 |
.BI \-R " remoteAccount" |
| 229 |
Specify accounting information to be used by a remote system that prints |
| 230 |
your output. |
| 231 |
.sp |
| 232 |
This parameter |
| 233 |
can be used to specify a billing code to be charged for the |
| 234 |
printing. |
| 235 |
.TP 5 |
| 236 |
.B \-r |
| 237 |
The DREADED |
| 238 |
.B "REMOVE AFTER PRINTING" |
| 239 |
option. |
| 240 |
Beware, for |
| 241 |
.I lpr |
| 242 |
will delete the files after spooling them. |
| 243 |
Present by demand from users for compatibility with other Berkeley lpr |
| 244 |
implementation, |
| 245 |
but really should NOT be present. |
| 246 |
.TP 5 |
| 247 |
.BI \-T " title" |
| 248 |
Specify the title used by |
| 249 |
.BR pr (1); |
| 250 |
defaults to the file name. |
| 251 |
.TP 5 |
| 252 |
\fB\-U\fP\ \fIusername\fP |
| 253 |
The |
| 254 |
.B \-U |
| 255 |
option is used to specify a user name |
| 256 |
for the job. |
| 257 |
This is available only to ROOT or users listed in the |
| 258 |
.I allow_user_setting |
| 259 |
configuration option. |
| 260 |
This is obviously a security loophole, |
| 261 |
but it is present to allow systems such as SAMBA |
| 262 |
to submit jobs on behalf of users. |
| 263 |
See |
| 264 |
.B "Authenticated Transfers" |
| 265 |
below. |
| 266 |
.TP 5 |
| 267 |
.B \-V |
| 268 |
Verbose mode. Additional -V flags increase verbosity. |
| 269 |
Use debug flags for extreme verbosity. |
| 270 |
.TP 5 |
| 271 |
.BI \-w " width" |
| 272 |
Specify the page width for printing the job. |
| 273 |
.TP 5 |
| 274 |
.BI \-X " path" |
| 275 |
User specified filter for job files. Processing is done on |
| 276 |
the client host. |
| 277 |
.TP 5 |
| 278 |
.B \-Y |
| 279 |
Make a direct connection to the printer device and do not spool. |
| 280 |
.TP 5 |
| 281 |
.BI -Z " options" |
| 282 |
Pass the specified options to the print spooler. |
| 283 |
Used when additional or specialized information |
| 284 |
must be provided to the spooler. |
| 285 |
.TP 5 |
| 286 |
.B "OBSOLETE OPTIONS Lower case \-c, \-d, \-g, \-n, \-t, \-v" |
| 287 |
Used to indicate: |
| 288 |
.B \-c |
| 289 |
is data produced by |
| 290 |
.BR cifplot (l), |
| 291 |
.B \-d |
| 292 |
is |
| 293 |
.BR tex (l) |
| 294 |
(DVI format from Stanford), |
| 295 |
.B \-g |
| 296 |
is |
| 297 |
standard plot data as produced by the |
| 298 |
.BR plot (3X) |
| 299 |
routines, |
| 300 |
.B \-n |
| 301 |
and |
| 302 |
.B \-t |
| 303 |
is output from (device independent) |
| 304 |
.BR troff , |
| 305 |
.B \-v |
| 306 |
a raster image for devices like the Benson Varian. |
| 307 |
.B "These are obsolete." |
| 308 |
These are retained for historical compatibility, |
| 309 |
but most of their functionality has been replaced by the |
| 310 |
abilities of the printer support system to determine the |
| 311 |
file type and do the appropriate conversions. |
| 312 |
.\".RE |
| 313 |
.TP 5 |
| 314 |
.B "OBSOLETE OPTION \-p" |
| 315 |
.B "This is obsolete." |
| 316 |
This option is retained for historical compatibility, |
| 317 |
but this functionality should be implemented on the |
| 318 |
client system before sending the job to the printer. |
| 319 |
Use |
| 320 |
.BR pr (1) |
| 321 |
to format the files, |
| 322 |
then print using |
| 323 |
.I f |
| 324 |
format. |
| 325 |
This may not be supported on the print system. |
| 326 |
.TP 5 |
| 327 |
.B "OBSOLETE \-s" |
| 328 |
This flag is included for compatibility with other versions of |
| 329 |
.BR lpr . |
| 330 |
In these versions it will create a symbolic link to the files to be |
| 331 |
printed. |
| 332 |
.B Lpr |
| 333 |
now sends files directly to the server and it is irrelevant. |
| 334 |
.TP 5 |
| 335 |
.BI "OBSOLETE OPTIONS \-1,2,3,4" "fontname" |
| 336 |
Specify a font to be mounted on font position \fIi\fR |
| 337 |
for TROFF printing (Obsolete). |
| 338 |
.SH FILENAMES |
| 339 |
.PP |
| 340 |
By default, |
| 341 |
if no filenames are specified |
| 342 |
.B lpr |
| 343 |
will read stdin and print it. |
| 344 |
.SH "AUTHENTICATED TRANSFERS" |
| 345 |
.PP |
| 346 |
The original LPR network protocol defined in RFC1179 did not |
| 347 |
provide for user to server authentication. |
| 348 |
This is now supported by LPRng. |
| 349 |
See the LPRng support documentation for details on its operation |
| 350 |
and support. |
| 351 |
.SH COMPATIBILITY |
| 352 |
.PP |
| 353 |
The LPRng version of |
| 354 |
.B lpr |
| 355 |
attempts to be functionally compatible with common implementations of |
| 356 |
.BR lpr . |
| 357 |
However, |
| 358 |
there are some commands and functionality that are deliberately missing. |
| 359 |
.IP "\fB\-s\fP\ Symbolic Links" 5 |
| 360 |
(Berkeley LPR) This option specified that a symbolic link |
| 361 |
to the original data file |
| 362 |
rather than a copy of the data file was to be used when spooling jobs. |
| 363 |
This opens up a variety of security problems, |
| 364 |
as well as being ineffective when printing to a remote host. |
| 365 |
.SH "THE -B, -Y, -X filter ULTRA-LIGHTWEIGHT PRINTING OPTIONS" |
| 366 |
.PP |
| 367 |
LPRng supports ultra-lightweight printing by eliminating the need |
| 368 |
for a print spooler. |
| 369 |
This is quite dangerous, but makes the lpr client very lightweight. |
| 370 |
The |
| 371 |
.B \-Y |
| 372 |
command line option and the |
| 373 |
.B :direct |
| 374 |
printcap option enables lpr to connect directly to a specified port |
| 375 |
or use a program to send a job. |
| 376 |
This filter also enables client side filtering, so if there are |
| 377 |
any filters specified in the printcap entry they will be used. |
| 378 |
For example: |
| 379 |
.nf |
| 380 |
lpr -Y -Phost%port file1 file2 ... |
| 381 |
approximately equivalent to: |
| 382 |
for i in file1 file2 ...; do |
| 383 |
${filter} <$i; |
| 384 |
# ${filter} is filter from printcap |
| 385 |
done >host%port (TCP/IP connection) |
| 386 |
|
| 387 |
lpr -Y -Phost%port -X userfilter file1 file2 ... |
| 388 |
approximately equivalent to: |
| 389 |
for i in file1 file2 ...; do |
| 390 |
userfilter <$i; |
| 391 |
done >host%port (TCP/IP connection) |
| 392 |
|
| 393 |
Summary: |
| 394 |
-P host%port > TCP/IP connection to host%port |
| 395 |
-P /dev/lp > /dev/lp |
| 396 |
-P '|/program' | /program |
| 397 |
|
| 398 |
SPECIAL CASE |
| 399 |
lpr -Y -Ppr@host -X userfilter file1 file2 ... |
| 400 |
approximately equivalent to: |
| 401 |
for i in file1 file2 ...; do |
| 402 |
userfilter <$i >temp.$i; |
| 403 |
done |
| 404 |
lpr -Ppr@host temp.file1 temp.file2 |
| 405 |
.fi |
| 406 |
.PP |
| 407 |
The |
| 408 |
.B \-B |
| 409 |
option or the :lpr_bounce is used to filter and make a single file out |
| 410 |
of a set of print files and then forward them. |
| 411 |
.RS |
| 412 |
.nf |
| 413 |
lpr -B -Ppr@host |
| 414 |
approximately equivalent to: |
| 415 |
lpr -Y -P/tmp/tempfile file1 file2 ... |
| 416 |
lpr -Ppr@host /tmp/tempfile |
| 417 |
.fi |
| 418 |
.RE |
| 419 |
.PP |
| 420 |
You can also use a printcap entry and the |
| 421 |
.B :direct |
| 422 |
options. |
| 423 |
.RS |
| 424 |
.nf |
| 425 |
Printcap: |
| 426 |
lp:direct:lp=h14%9100:remote_support=R |
| 427 |
lpr -Plp file1 file2 |
| 428 |
Same as: |
| 429 |
lpr -Plp -Y -Ph14%9100 file1 file2 |
| 430 |
.fi |
| 431 |
.RE |
| 432 |
.PP |
| 433 |
The |
| 434 |
.B :remote_support |
| 435 |
option is used to prevent the |
| 436 |
.B lpq |
| 437 |
and |
| 438 |
.B lpc |
| 439 |
program from attempting to send jobs to the device. |
| 440 |
|
| 441 |
.SH ENVIRONMENT |
| 442 |
.PP |
| 443 |
By default, |
| 444 |
the destination printer |
| 445 |
is taken from |
| 446 |
the command line |
| 447 |
.I "-P printer" |
| 448 |
value, |
| 449 |
then |
| 450 |
the environment variables |
| 451 |
PRINTER, |
| 452 |
LPDEST, |
| 453 |
NPRINTER, |
| 454 |
NGPRINTER, |
| 455 |
then first entry in the printcap information, |
| 456 |
and and finally the default_printer entry from the |
| 457 |
configuration file, |
| 458 |
and then the compile time default. |
| 459 |
.SH "EXIT STATUS" |
| 460 |
.PP |
| 461 |
The following exit values are returned: |
| 462 |
.TP 15 |
| 463 |
.B "zero (0)" |
| 464 |
Successful completion. |
| 465 |
.TP |
| 466 |
.B "non-zero (!=0)" |
| 467 |
An error occurred. |
| 468 |
.SH "PRINTCAP INFORMATION" |
| 469 |
.LP |
| 470 |
The printer names and other information is obtained by using a printcap |
| 471 |
file or some other database. |
| 472 |
The ${HOME}/.printcap |
| 473 |
file can be used to specify user level options and configuration |
| 474 |
information. |
| 475 |
See |
| 476 |
printcap(5) |
| 477 |
for more information. |
| 478 |
.SH FILES |
| 479 |
.PP |
| 480 |
The files used by LPRng are set by values in the |
| 481 |
printer configuration file. |
| 482 |
The following are a commonly used set of default values. |
| 483 |
.nf |
| 484 |
.ta \w'/var/spool/lpd/printcap.<hostname> 'u |
| 485 |
/etc/lprng/lpd.conf LPRng configuration file |
| 486 |
${HOME}/.printcap user printer description file |
| 487 |
/etc/printcap printer description file |
| 488 |
/etc/lprng/lpd.perms permissions |
| 489 |
/var/run/lprng/lpd lock file for queue control |
| 490 |
/var/spool/lpd spool directories |
| 491 |
/var/spool/lpd/QUEUE/control queue control |
| 492 |
/var/spool/lpd/QUEUE/log trace or debug log file |
| 493 |
/var/spool/lpd/QUEUE/acct accounting file |
| 494 |
/var/spool/lpd/QUEUE/status status file |
| 495 |
.fi |
| 496 |
.SH "SEE ALSO" |
| 497 |
.BR lpd.conf (5), |
| 498 |
.BR lpc (8), |
| 499 |
.BR lpd (8), |
| 500 |
.BR checkpc (8), |
| 501 |
.BR lpq (1), |
| 502 |
.BR lprm (1), |
| 503 |
.BR checkpc (8), |
| 504 |
.BR printcap (5), |
| 505 |
.BR lpd.perms (5), |
| 506 |
.BR pr (1). |
| 507 |
.SH "AUTHOR" |
| 508 |
Patrick Powell <[email protected]>. |
| 509 |
.SH DIAGNOSTICS |
| 510 |
Most of the diagnostics are self explanatory. |
| 511 |
If you are puzzled over the exact cause of failure, |
| 512 |
set the debugging level on (-D5) and run again. |
| 513 |
The debugging information will |
| 514 |
help you to pinpoint the exact cause of failure. |
| 515 |
.SH "HISTORY" |
| 516 |
LPRng is a enhanced printer spooler system |
| 517 |
with functionality similar to the Berkeley LPR software. |
| 518 |
The LPRng developer mailing list is [email protected]; |
| 519 |
subscribe by visiting |
| 520 |
.B https://lists.sourceforge.net/lists/listinfo/lprng-devel |
| 521 |
or sending mail to |
| 522 |
.B [email protected] |
| 523 |
with |
| 524 |
the word |
| 525 |
.I subscribe |
| 526 |
in the body. |
| 527 |
.br |
| 528 |
The software is available via |
| 529 |
.B http://lprng.sourceforge.net |