| 1 |
.TH floppymeter 1 "27Jan21" fdutils-5.6 |
| 2 |
.SH Name |
| 3 |
floppymeter - measure raw capacity and exact rotation speed of floppy drive |
| 4 |
'\" t |
| 5 |
.de TQ |
| 6 |
.br |
| 7 |
.ns |
| 8 |
.TP \\$1 |
| 9 |
.. |
| 10 |
|
| 11 |
.tr \(is' |
| 12 |
.tr \(if` |
| 13 |
.tr \(pd" |
| 14 |
|
| 15 |
.SH Note |
| 16 |
This manpage has been automatically generated from fdutils's texinfo |
| 17 |
documentation. However, this process is only approximative, and some |
| 18 |
items, such as cross-references, footnotes and indices are lost in this |
| 19 |
translation process. Indeed, these items have no appropriate |
| 20 |
representation in the manpage format. Moreover, only the items specific |
| 21 |
to each command have been translated, and the general information about |
| 22 |
fdutils has been dropped in the manpage version. Thus I strongly advise |
| 23 |
you to use the original texinfo doc. |
| 24 |
.TP |
| 25 |
* \ \ |
| 26 |
To generate a printable copy from the texinfo doc, run the following |
| 27 |
commands: |
| 28 |
|
| 29 |
.nf |
| 30 |
.ft 3 |
| 31 |
.in +0.3i |
| 32 |
./configure; make dvi; dvips fdutils.dvi |
| 33 |
.fi |
| 34 |
.in -0.3i |
| 35 |
.ft R |
| 36 |
|
| 37 |
\&\fR |
| 38 |
.TP |
| 39 |
* \ \ |
| 40 |
To generate a HTML copy, run: |
| 41 |
|
| 42 |
.nf |
| 43 |
.ft 3 |
| 44 |
.in +0.3i |
| 45 |
./configure; make html |
| 46 |
.fi |
| 47 |
.in -0.3i |
| 48 |
.ft R |
| 49 |
|
| 50 |
\&\fRA pre-made HTML can be found at: |
| 51 |
\&\fR\&\f(CW\(ifhttp://www.tux.org/pub/knaff/fdutils\(is\fR |
| 52 |
.TP |
| 53 |
* \ \ |
| 54 |
To generate an info copy (browsable using emacs' info mode), run: |
| 55 |
|
| 56 |
.nf |
| 57 |
.ft 3 |
| 58 |
.in +0.3i |
| 59 |
./configure; make info |
| 60 |
.fi |
| 61 |
.in -0.3i |
| 62 |
.ft R |
| 63 |
|
| 64 |
\&\fR |
| 65 |
.PP |
| 66 |
The texinfo doc looks most pretty when printed or as HTML. Indeed, in |
| 67 |
the info version certain examples are difficult to read due to the |
| 68 |
quoting conventions used in info. |
| 69 |
.SH Description |
| 70 |
.PP |
| 71 |
|
| 72 |
.nf |
| 73 |
.ft 3 |
| 74 |
.in +0.3i |
| 75 |
\&\fR\&\f(CWfloppymeter [\fR\&\f(CW\-f] [\fR\&\f(CW\-w \fIwarmup\-delay\fR\&\f(CW] [\fR\&\f(CW\-W \fIwindow\fR\&\f(CW] |
| 76 |
[\fR\&\f(CW\-c \fIcycles\fR\&\f(CW] [\fR\&\f(CW\-h] \fIdrive\fR\&\f(CW |
| 77 |
.fi |
| 78 |
.in -0.3i |
| 79 |
.ft R |
| 80 |
|
| 81 |
\&\fR |
| 82 |
.PP |
| 83 |
The \fR\&\f(CWfloppymeter\fR program measures characteristic parameters of a |
| 84 |
floppy drive and floppy controller, such as the rotation speed of the |
| 85 |
drive, the data transfer rate of the controller, and the resulting raw |
| 86 |
capacity of a disk track. To use this program, insert a disposable |
| 87 |
floppy in the drive, and type \fR\&\f(CWfloppymeter \-\-\fR\fIdensity\fR, where |
| 88 |
density describes the density of the disk used for the test. (Should be |
| 89 |
one of \fR\&\f(CWdd, hd\fR or \fR\&\f(CWed\fR). \fBCAUTION: the data on the |
| 90 |
disk will be erased\fR. This program should be used to verify whether the |
| 91 |
drive and controller are out of tolerance if you experience problems |
| 92 |
with some high capacity formats. It only needs to be run once per |
| 93 |
drive: although a disk is needed to perform the measurements, the |
| 94 |
measured data only depend on the drive and the controller, and not on |
| 95 |
the disk. |
| 96 |
.PP |
| 97 |
To measure the raw capacity of the disk track, the floppymeter program |
| 98 |
formats the first track of the drive in a special way that allows it to |
| 99 |
read the raw data (gaps and headers) of the disk. \fBThus, all data |
| 100 |
previously stored on that disk is lost\fR. |
| 101 |
.PP |
| 102 |
The rotation speed is measured by timing the return time of a |
| 103 |
\&\fR\&\f(CWreadid\fR command. In order to gain more precision, the command is |
| 104 |
issued many times in a row. During this phase, the number of rotations |
| 105 |
since the start of the test, the average time per rotation since the start, |
| 106 |
and a sliding average of the times of the last 30 rotations is printed, |
| 107 |
and updated continuously. |
| 108 |
.PP |
| 109 |
The data transfer rate is deduced from the two parameters above. |
| 110 |
.PP |
| 111 |
At the end of the program, all parameters (raw capacity, duration of one |
| 112 |
rotation, and data transfer rate) are printed again, as well as their |
| 113 |
relative deviation to the standard value. Finally, it suggests a |
| 114 |
capacity deviation description line, which can be directly pasted into |
| 115 |
the drive definition file (See section Drive descriptions.). |
| 116 |
.PP |
| 117 |
Usually, the data transfer rate should not deviate more than 150 ppm |
| 118 |
from the expected value, and the rotation speed of the drive should not |
| 119 |
deviate more than 3000 ppm from the expected value. If these deviations |
| 120 |
are bigger, you may get problems with certain high capacity formats. |
| 121 |
.PP |
| 122 |
If the raw capacity of the drive is too small, some high capacity |
| 123 |
formats may become unformattable on this drive/controller combo. |
| 124 |
.PP |
| 125 |
If on the other hand, the raw capacity of the drive is too big, you may |
| 126 |
get problems when writing to a disk formatted by this drive on another |
| 127 |
drive with a smaller raw capacity. In order to avoid this, increase |
| 128 |
superformats gap parameter (\fR\&\f(CW\-G\fR). |
| 129 |
.IP |
| 130 |
.TP |
| 131 |
\&\fR\&\f(CW\-h\fR\ |
| 132 |
Prints a short help |
| 133 |
.TP |
| 134 |
\&\fR\&\f(CW\-\-dd\fR\ |
| 135 |
Tells the program that we use a Double Density disk. |
| 136 |
.TP |
| 137 |
\&\fR\&\f(CW\-\-hd\fR\ |
| 138 |
Tells the program that we use a High Density disk. |
| 139 |
.TP |
| 140 |
\&\fR\&\f(CW\-\-ed\fR\ |
| 141 |
Tells the program that we use an Extra Density disk. |
| 142 |
.TP |
| 143 |
\&\fR\&\f(CW\-f\fR\ |
| 144 |
Runs the measurement non interactively. With this option, the program |
| 145 |
doesn't ask for confirmation, and doesn't display the continuously |
| 146 |
updated values during the rotation speed measurement. |
| 147 |
.TP |
| 148 |
\&\fR\&\f(CW\-W\ \fIWindow\fR\&\f(CW\fR\ |
| 149 |
This value describes how many rotations are used for the computation of |
| 150 |
the sliding average. Default is 30. |
| 151 |
.TP |
| 152 |
\&\fR\&\f(CW\-c\ \fIcycles\fR\&\f(CW\fR\ |
| 153 |
Describes the number of rotations clocked during the rotations speed |
| 154 |
determination test. Default is 1000. |
| 155 |
.PP |
| 156 |
.SH Bugs |
| 157 |
.PP |
| 158 |
This program is quite new, and may have bugs. Here are a few suggested |
| 159 |
tests to check its sanity: |
| 160 |
.TP |
| 161 |
* \ \ |
| 162 |
The deviation of the data transfer rate solely depends on the |
| 163 |
controller. It should not be different between two drives connected to |
| 164 |
the same controller. However, the drive rotation speed may be different |
| 165 |
for different drives. |
| 166 |
.TP |
| 167 |
* \ \ |
| 168 |
All data transfer rates (for double, high and extra density) are derived |
| 169 |
from a same master frequency. Thus the \fIdeviation\fR of the data |
| 170 |
transfer rate should be independent of the density used. |
| 171 |
.SH See Also |
| 172 |
Fdutils' texinfo doc |