Debian Codegraph @

doc/man/nvmf_disc_log_entry.2

raw
1 .TH "libnvme" 9 "struct nvmf_disc_log_entry" "November 2025" "API Manual" LINUX
2 .SH NAME
3 struct nvmf_disc_log_entry \- Discovery Log Page entry
4 .SH SYNOPSIS
5 struct nvmf_disc_log_entry {
6 .br
7 .BI " __u8 trtype;"
8 .br
9 .BI " __u8 adrfam;"
10 .br
11 .BI " __u8 subtype;"
12 .br
13 .BI " __u8 treq;"
14 .br
15 .BI " __le16 portid;"
16 .br
17 .BI " __le16 cntlid;"
18 .br
19 .BI " __le16 asqsz;"
20 .br
21 .BI " __le16 eflags;"
22 .br
23 .BI " __u8 rsvd12[20];"
24 .br
25 .BI " char trsvcid[NVMF_TRSVCID_SIZE];"
26 .br
27 .BI " __u8 rsvd64[192];"
28 .br
29 .BI " char subnqn[NVME_NQN_LENGTH];"
30 .br
31 .BI " char traddr[NVMF_TRADDR_SIZE];"
32 .br
33 .BI " union nvmf_tsas tsas;"
34 .br
35 .BI "
36 };
37 .br
38
39 .SH Members
40 .IP "trtype" 12
41 Transport Type (TRTYPE): Specifies the NVMe Transport type.
42 See \fIenum nvmf_trtype\fP.
43 .IP "adrfam" 12
44 Address Family (ADRFAM): Specifies the address family.
45 See \fIenum nvmf_addr_family\fP.
46 .IP "subtype" 12
47 Subsystem Type (SUBTYPE): Specifies the type of the NVM subsystem
48 that is indicated in this entry. See \fIenum nvme_subsys_type\fP.
49 .IP "treq" 12
50 Transport Requirements (TREQ): Indicates requirements for the NVMe
51 Transport. See \fIenum nvmf_treq\fP.
52 .IP "portid" 12
53 Port ID (PORTID): Specifies a particular NVM subsystem port.
54 Different NVMe Transports or address families may utilize the same
55 Port ID value (e.g. a Port ID may support both iWARP and RoCE).
56 .IP "cntlid" 12
57 Controller ID (CNTLID): Specifies the controller ID. If the NVM
58 subsystem uses a dynamic controller model, then this field shall
59 be set to FFFFh. If the NVM subsystem uses a static controller model,
60 then this field may be set to a specific controller ID (values 0h
61 to FFEFh are valid). If the NVM subsystem uses a static controller
62 model and the value indicated is FFFEh, then the host should remember
63 the Controller ID returned as part of the Fabrics Connect command
64 in order to re-establish an association in the future with the same
65 controller.
66 .IP "asqsz" 12
67 Admin Max SQ Size (ASQSZ): Specifies the maximum size of an Admin
68 Submission Queue. This applies to all controllers in the NVM
69 subsystem. The value shall be a minimum of 32 entries.
70 .IP "eflags" 12
71 Entry Flags (EFLAGS): Indicates additional information related to
72 the current entry. See \fIenum nvmf_disc_eflags\fP.
73 .IP "rsvd12" 12
74 Reserved
75 .IP "trsvcid" 12
76 Transport Service Identifier (TRSVCID): Specifies the NVMe Transport
77 service identifier as an ASCII string. The NVMe Transport service
78 identifier is specified by the associated NVMe Transport binding
79 specification.
80 .IP "rsvd64" 12
81 Reserved
82 .IP "subnqn" 12
83 NVM Subsystem Qualified Name (SUBNQN): NVMe Qualified Name (NQN)
84 that uniquely identifies the NVM subsystem. For a subsystem, if that
85 Discovery subsystem has a unique NQN (i.e., the NVM Subsystem NVMe
86 Qualified Name (SUBNQN) field in that Discovery subsystem's Identify
87 Controller data structure contains a unique NQN value), then the
88 value returned shall be that unique NQN. If the Discovery subsystem
89 does not have a unique NQN, then the value returned shall be the
90 well-known Discovery Service NQN (nqn.2014-08.org.nvmexpress.discovery).
91 .IP "traddr" 12
92 Transport Address (TRADDR): Specifies the address of the NVM subsystem
93 that may be used for a Connect command as an ASCII string. The
94 Address Family field describes the reference for parsing this field.
95 .IP "tsas" 12
96 Transport specific attribute settings