Debian Codegraph @

doc/man/nvme_id_psd.2

raw
1 .TH "libnvme" 9 "struct nvme_id_psd" "November 2025" "API Manual" LINUX
2 .SH NAME
3 struct nvme_id_psd \- Power Management data structure
4 .SH SYNOPSIS
5 struct nvme_id_psd {
6 .br
7 .BI " __le16 mp;"
8 .br
9 .BI " __u8 rsvd2;"
10 .br
11 .BI " __u8 flags;"
12 .br
13 .BI " __le32 enlat;"
14 .br
15 .BI " __le32 exlat;"
16 .br
17 .BI " __u8 rrt;"
18 .br
19 .BI " __u8 rrl;"
20 .br
21 .BI " __u8 rwt;"
22 .br
23 .BI " __u8 rwl;"
24 .br
25 .BI " __le16 idlp;"
26 .br
27 .BI " __u8 ips;"
28 .br
29 .BI " __u8 rsvd19;"
30 .br
31 .BI " __le16 actp;"
32 .br
33 .BI " __u8 apws;"
34 .br
35 .BI " __u8 epfrt;"
36 .br
37 .BI " __u8 fqvt;"
38 .br
39 .BI " __u8 epfvt;"
40 .br
41 .BI " __u8 epfr_fqv_ts;"
42 .br
43 .BI " __u8 epfvts;"
44 .br
45 .BI " __u8 rsvd28[4];"
46 .br
47 .BI "
48 };
49 .br
50
51 .SH Members
52 .IP "mp" 12
53 Maximum Power indicates the sustained maximum power consumed by the
54 NVM subsystem in this power state. The power in Watts is equal to
55 the value in this field multiplied by the scale specified in the Max
56 Power Scale bit (see \fIenum nvme_psd_flags\fP). A value of 0 indicates
57 Maximum Power is not reported.
58 .IP "rsvd2" 12
59 Reserved
60 .IP "flags" 12
61 Additional decoding flags, see \fIenum nvme_psd_flags\fP.
62 .IP "enlat" 12
63 Entry Latency indicates the maximum latency in microseconds
64 associated with entering this power state. A value of 0 indicates
65 Entry Latency is not reported.
66 .IP "exlat" 12
67 Exit Latency indicates the maximum latency in microseconds
68 associated with exiting this power state. A value of 0 indicates
69 Exit Latency is not reported.
70 .IP "rrt" 12
71 Relative Read Throughput indicates the read throughput rank
72 associated with this power state relative to others. The value in
73 this is less than the number of supported power states.
74 .IP "rrl" 12
75 Relative Read Latency indicates the read latency rank associated
76 with this power state relative to others. The value in this field is
77 less than the number of supported power states.
78 .IP "rwt" 12
79 Relative Write Throughput indicates write throughput rank associated
80 with this power state relative to others. The value in this field is
81 less than the number of supported power states
82 .IP "rwl" 12
83 Relative Write Latency indicates the write latency rank associated
84 with this power state relative to others. The value in this field is
85 less than the number of supported power states
86 .IP "idlp" 12
87 Idle Power indicates the typical power consumed by the NVM
88 subsystem over 30 seconds in this power state when idle.
89 .IP "ips" 12
90 Idle Power Scale indicates the scale for \fIstruct nvme_id_psd\fP.idlp,
91 see \fIenum nvme_psd_ps\fP for decoding this field.
92 .IP "rsvd19" 12
93 Reserved
94 .IP "actp" 12
95 Active Power indicates the largest average power consumed by the
96 NVM subsystem over a 10 second period in this power state with
97 the workload indicated in the Active Power Workload field.
98 .IP "apws" 12
99 Bits 7-6: Active Power Scale(APS) indicates the scale for the \fIstruct
100 nvme_id_psd\fP.actp, see \fIenum nvme_psd_ps\fP for decoding this value.
101 Bits 2-0: Active Power Workload(APW) indicates the workload
102 used to calculate maximum power for this power state.
103 See \fIenum nvme_psd_workload\fP for decoding this field.
104 .IP "epfrt" 12
105 Emergency power fail recovery time
106 .IP "fqvt" 12
107 Forced quiescence vault time
108 .IP "epfvt" 12
109 Emergency power fail vault time
110 .IP "epfr_fqv_ts" 12
111 Bits 7-4: Forced quiescence vault time scale
112 Bits 3-0: Emergency power fail recovery time scale
113 .IP "epfvts" 12
114 Bits 3-0: Emergency power fail vault time scale
115 .IP "rsvd28" 12
116 Reserved