Debian Codegraph @

doc/man/nvme_id_ctrl.2

raw
1 .TH "libnvme" 9 "struct nvme_id_ctrl" "November 2025" "API Manual" LINUX
2 .SH NAME
3 struct nvme_id_ctrl \- Identify Controller data structure
4 .SH SYNOPSIS
5 struct nvme_id_ctrl {
6 .br
7 .BI " __le16 vid;"
8 .br
9 .BI " __le16 ssvid;"
10 .br
11 .BI " char sn[20];"
12 .br
13 .BI " char mn[40];"
14 .br
15 .BI " char fr[8];"
16 .br
17 .BI " __u8 rab;"
18 .br
19 .BI " __u8 ieee[3];"
20 .br
21 .BI " __u8 cmic;"
22 .br
23 .BI " __u8 mdts;"
24 .br
25 .BI " __le16 cntlid;"
26 .br
27 .BI " __le32 ver;"
28 .br
29 .BI " __le32 rtd3r;"
30 .br
31 .BI " __le32 rtd3e;"
32 .br
33 .BI " __le32 oaes;"
34 .br
35 .BI " __le32 ctratt;"
36 .br
37 .BI " __le16 rrls;"
38 .br
39 .BI " __u8 bpcap;"
40 .br
41 .BI " __u8 rsvd103;"
42 .br
43 .BI " __le32 nssl;"
44 .br
45 .BI " __u8 rsvd108[2];"
46 .br
47 .BI " __u8 plsi;"
48 .br
49 .BI " __u8 cntrltype;"
50 .br
51 .BI " __u8 fguid[16];"
52 .br
53 .BI " __le16 crdt1;"
54 .br
55 .BI " __le16 crdt2;"
56 .br
57 .BI " __le16 crdt3;"
58 .br
59 .BI " __u8 crcap;"
60 .br
61 .BI " __u8 rsvd135[118];"
62 .br
63 .BI " __u8 nvmsr;"
64 .br
65 .BI " __u8 vwci;"
66 .br
67 .BI " __u8 mec;"
68 .br
69 .BI " __le16 oacs;"
70 .br
71 .BI " __u8 acl;"
72 .br
73 .BI " __u8 aerl;"
74 .br
75 .BI " __u8 frmw;"
76 .br
77 .BI " __u8 lpa;"
78 .br
79 .BI " __u8 elpe;"
80 .br
81 .BI " __u8 npss;"
82 .br
83 .BI " __u8 avscc;"
84 .br
85 .BI " __u8 apsta;"
86 .br
87 .BI " __le16 wctemp;"
88 .br
89 .BI " __le16 cctemp;"
90 .br
91 .BI " __le16 mtfa;"
92 .br
93 .BI " __le32 hmpre;"
94 .br
95 .BI " __le32 hmmin;"
96 .br
97 .BI " __u8 tnvmcap[16];"
98 .br
99 .BI " __u8 unvmcap[16];"
100 .br
101 .BI " __le32 rpmbs;"
102 .br
103 .BI " __le16 edstt;"
104 .br
105 .BI " __u8 dsto;"
106 .br
107 .BI " __u8 fwug;"
108 .br
109 .BI " __le16 kas;"
110 .br
111 .BI " __le16 hctma;"
112 .br
113 .BI " __le16 mntmt;"
114 .br
115 .BI " __le16 mxtmt;"
116 .br
117 .BI " __le32 sanicap;"
118 .br
119 .BI " __le32 hmminds;"
120 .br
121 .BI " __le16 hmmaxd;"
122 .br
123 .BI " __le16 nsetidmax;"
124 .br
125 .BI " __le16 endgidmax;"
126 .br
127 .BI " __u8 anatt;"
128 .br
129 .BI " __u8 anacap;"
130 .br
131 .BI " __le32 anagrpmax;"
132 .br
133 .BI " __le32 nanagrpid;"
134 .br
135 .BI " __le32 pels;"
136 .br
137 .BI " __le16 domainid;"
138 .br
139 .BI " __u8 kpioc;"
140 .br
141 .BI " __u8 rsvd359;"
142 .br
143 .BI " __le16 mptfawr;"
144 .br
145 .BI " __u8 rsvd362[6];"
146 .br
147 .BI " __u8 megcap[16];"
148 .br
149 .BI " __u8 tmpthha;"
150 .br
151 .BI " __u8 rsvd385;"
152 .br
153 .BI " __le16 cqt;"
154 .br
155 .BI " __u8 rsvd388[124];"
156 .br
157 .BI " __u8 sqes;"
158 .br
159 .BI " __u8 cqes;"
160 .br
161 .BI " __le16 maxcmd;"
162 .br
163 .BI " __le32 nn;"
164 .br
165 .BI " __le16 oncs;"
166 .br
167 .BI " __le16 fuses;"
168 .br
169 .BI " __u8 fna;"
170 .br
171 .BI " __u8 vwc;"
172 .br
173 .BI " __le16 awun;"
174 .br
175 .BI " __le16 awupf;"
176 .br
177 .BI " __u8 icsvscc;"
178 .br
179 .BI " __u8 nwpc;"
180 .br
181 .BI " __le16 acwu;"
182 .br
183 .BI " __le16 ocfs;"
184 .br
185 .BI " __le32 sgls;"
186 .br
187 .BI " __le32 mnan;"
188 .br
189 .BI " __u8 maxdna[16];"
190 .br
191 .BI " __le32 maxcna;"
192 .br
193 .BI " __le32 oaqd;"
194 .br
195 .BI " __u8 rhiri;"
196 .br
197 .BI " __u8 hirt;"
198 .br
199 .BI " __le16 cmmrtd;"
200 .br
201 .BI " __le16 nmmrtd;"
202 .br
203 .BI " __u8 minmrtg;"
204 .br
205 .BI " __u8 maxmrtg;"
206 .br
207 .BI " __u8 trattr;"
208 .br
209 .BI " __u8 rsvd577;"
210 .br
211 .BI " __le16 mcudmq;"
212 .br
213 .BI " __le16 mnsudmq;"
214 .br
215 .BI " __le16 mcmr;"
216 .br
217 .BI " __le16 nmcmr;"
218 .br
219 .BI " __le16 mcdqpc;"
220 .br
221 .BI " __u8 rsvd588[180];"
222 .br
223 .BI " char subnqn[NVME_NQN_LENGTH];"
224 .br
225 .BI " __u8 rsvd1024[768];"
226 .br
227 .BI " __le32 ioccsz;"
228 .br
229 .BI " __le32 iorcsz;"
230 .br
231 .BI " __le16 icdoff;"
232 .br
233 .BI " __u8 fcatt;"
234 .br
235 .BI " __u8 msdbd;"
236 .br
237 .BI " __le16 ofcs;"
238 .br
239 .BI " __u8 dctype;"
240 .br
241 .BI " __u8 rsvd1807[241];"
242 .br
243 .BI " struct nvme_id_psd psd[32];"
244 .br
245 .BI " __u8 vs[1024];"
246 .br
247 .BI "
248 };
249 .br
250
251 .SH Members
252 .IP "vid" 12
253 PCI Vendor ID, the company vendor identifier that is assigned by
254 the PCI SIG.
255 .IP "ssvid" 12
256 PCI Subsystem Vendor ID, the company vendor identifier that is
257 assigned by the PCI SIG for the subsystem.
258 .IP "sn" 12
259 Serial Number in ASCII
260 .IP "mn" 12
261 Model Number in ASCII
262 .IP "fr" 12
263 Firmware Revision in ASCII, the currently active firmware
264 revision for the NVM subsystem
265 .IP "rab" 12
266 Recommended Arbitration Burst, reported as a power of two
267 .IP "ieee" 12
268 IEEE assigned Organization Unique Identifier
269 .IP "cmic" 12
270 Controller Multipath IO and Namespace Sharing Capabilities of
271 the controller and NVM subsystem. See \fIenum nvme_id_ctrl_cmic\fP.
272 .IP "mdts" 12
273 Max Data Transfer Size is the largest data transfer size. The
274 host should not submit a command that exceeds this maximum data
275 transfer size. The value is in units of the minimum memory page
276 size (CAP.MPSMIN) and is reported as a power of two
277 .IP "cntlid" 12
278 Controller ID, the NVM subsystem unique controller identifier
279 associated with the controller.
280 .IP "ver" 12
281 Version, this field contains the value reported in the Version
282 register, or property (see \fIenum nvme_registers\fP NVME_REG_VS).
283 .IP "rtd3r" 12
284 RTD3 Resume Latency, the expected latency in microseconds to resume
285 from Runtime D3
286 .IP "rtd3e" 12
287 RTD3 Exit Latency, the typical latency in microseconds to enter
288 Runtime D3.
289 .IP "oaes" 12
290 Optional Async Events Supported, see \fIenum\fP nvme_id_ctrl_oaes.
291 .IP "ctratt" 12
292 Controller Attributes, see \fIenum\fP nvme_id_ctrl_ctratt.
293 .IP "rrls" 12
294 Read Recovery Levels. If a bit is set, then the corresponding
295 Read Recovery Level is supported. If a bit is cleared, then the
296 corresponding Read Recovery Level is not supported.
297 .IP "bpcap" 12
298 Boot Partition Capabilities, see \fIenum nvme_id_ctrl_bpcap\fP.
299 .IP "rsvd103" 12
300 Reserved
301 .IP "nssl" 12
302 NVM Subsystem Shutdown Latency (NSSL). This field indicates the
303 typical latency in microseconds for an NVM Subsystem Shutdown to
304 complete.
305 .IP "rsvd108" 12
306 Reserved
307 .IP "plsi" 12
308 Power Loss Signaling Information (PLSI), see \fIenum nvme_id_ctrl_plsi\fP
309 .IP "cntrltype" 12
310 Controller Type, see \fIenum nvme_id_ctrl_cntrltype\fP
311 .IP "fguid" 12
312 FRU GUID, a 128-bit value that is globally unique for a given
313 Field Replaceable Unit
314 .IP "crdt1" 12
315 Controller Retry Delay time in 100 millisecond units if CQE CRD
316 field is 1
317 .IP "crdt2" 12
318 Controller Retry Delay time in 100 millisecond units if CQE CRD
319 field is 2
320 .IP "crdt3" 12
321 Controller Retry Delay time in 100 millisecond units if CQE CRD
322 field is 3
323 .IP "crcap" 12
324 Controller Reachability Capabilities (CRCAP), see
325 \fIenum nvme_id_ctrl_crcap\fP
326 .IP "rsvd135" 12
327 Reserved
328 .IP "nvmsr" 12
329 NVM Subsystem Report, see \fIenum nvme_id_ctrl_nvmsr\fP
330 .IP "vwci" 12
331 VPD Write Cycle Information, see \fIenum nvme_id_ctrl_vwci\fP
332 .IP "mec" 12
333 Management Endpoint Capabilities, see \fIenum nvme_id_ctrl_mec\fP
334 .IP "oacs" 12
335 Optional Admin Command Support,the optional Admin commands and
336 features supported by the controller, see \fIenum nvme_id_ctrl_oacs\fP.
337 .IP "acl" 12
338 Abort Command Limit, the maximum number of concurrently
339 executing Abort commands supported by the controller. This is a
340 0's based value.
341 .IP "aerl" 12
342 Async Event Request Limit, the maximum number of concurrently
343 outstanding Asynchronous Event Request commands supported by the
344 controller This is a 0's based value.
345 .IP "frmw" 12
346 Firmware Updates indicates capabilities regarding firmware
347 updates. See \fIenum nvme_id_ctrl_frmw\fP.
348 .IP "lpa" 12
349 Log Page Attributes, see \fIenum nvme_id_ctrl_lpa\fP.
350 .IP "elpe" 12
351 Error Log Page Entries, the maximum number of Error Information
352 log entries that are stored by the controller. This field is a
353 0's based value.
354 .IP "npss" 12
355 Number of Power States Supported, the number of NVM Express
356 power states supported by the controller, indicating the number
357 of valid entries in \fIstruct nvme_id_ctrl\fP.psd. This is a 0's
358 based value.
359 .IP "avscc" 12
360 Admin Vendor Specific Command Configuration, see
361 \fIenum nvme_id_ctrl_avscc\fP.
362 .IP "apsta" 12
363 Autonomous Power State Transition Attributes, see
364 \fIenum nvme_id_ctrl_apsta\fP.
365 .IP "wctemp" 12
366 Warning Composite Temperature Threshold indicates
367 the minimum Composite Temperature field value (see \fIstruct
368 nvme_smart_log\fP.critical_comp_time) that indicates an overheating
369 condition during which controller operation continues.
370 .IP "cctemp" 12
371 Critical Composite Temperature Threshold, field indicates the
372 minimum Composite Temperature field value (see \fIstruct
373 nvme_smart_log\fP.critical_comp_time) that indicates a critical
374 overheating condition.
375 .IP "mtfa" 12
376 Maximum Time for Firmware Activation indicates the maximum time
377 the controller temporarily stops processing commands to activate
378 the firmware image, specified in 100 millisecond units. This
379 field is always valid if the controller supports firmware
380 activation without a reset.
381 .IP "hmpre" 12
382 Host Memory Buffer Preferred Size indicates the preferred size
383 that the host is requested to allocate for the Host Memory
384 Buffer feature in 4 KiB units.
385 .IP "hmmin" 12
386 Host Memory Buffer Minimum Size indicates the minimum size that
387 the host is requested to allocate for the Host Memory Buffer
388 feature in 4 KiB units.
389 .IP "tnvmcap" 12
390 Total NVM Capacity, the total NVM capacity in the NVM subsystem.
391 The value is in bytes.
392 .IP "unvmcap" 12
393 Unallocated NVM Capacity, the unallocated NVM capacity in the
394 NVM subsystem. The value is in bytes.
395 .IP "rpmbs" 12
396 Replay Protected Memory Block Support, see
397 \fIenum nvme_id_ctrl_rpmbs\fP.
398 .IP "edstt" 12
399 Extended Device Self-test Time, if Device Self-test command is
400 supported (see \fIstruct nvme_id_ctrl\fP.oacs, NVME_CTRL_OACS_SELF_TEST),
401 then this field indicates the nominal amount of time in one
402 minute units that the controller takes to complete an extended
403 device self-test operation when in power state 0.
404 .IP "dsto" 12
405 Device Self-test Options, see \fIenum nvme_id_ctrl_dsto\fP.
406 .IP "fwug" 12
407 Firmware Update Granularity indicates the granularity and
408 alignment requirement of the firmware image being updated by the
409 Firmware Image Download command. The value is reported in 4 KiB
410 units. A value of 0h indicates no information on granularity is
411 provided. A value of FFh indicates no restriction
412 .IP "kas" 12
413 Keep Alive Support indicates the granularity of the Keep Alive
414 Timer in 100 millisecond units.
415 .IP "hctma" 12
416 Host Controlled Thermal Management Attributes, see
417 \fIenum nvme_id_ctrl_hctm\fP.
418 .IP "mntmt" 12
419 Minimum Thermal Management Temperature indicates the minimum
420 temperature, in degrees Kelvin, that the host may request in the
421 Thermal Management Temperature 1 field and Thermal Management
422 Temperature 2 field of a Set Features command with the Feature
423 Identifier field set to NVME_FEAT_FID_HCTM.
424 .IP "mxtmt" 12
425 Maximum Thermal Management Temperature indicates the maximum
426 temperature, in degrees Kelvin, that the host may request in the
427 Thermal Management Temperature 1 field and Thermal Management
428 Temperature 2 field of the Set Features command with the Feature
429 Identifier set to NVME_FEAT_FID_HCTM.
430 .IP "sanicap" 12
431 Sanitize Capabilities, see \fIenum nvme_id_ctrl_sanicap\fP
432 .IP "hmminds" 12
433 Host Memory Buffer Minimum Descriptor Entry Size indicates the
434 minimum usable size of a Host Memory Buffer Descriptor Entry in
435 4 KiB units.
436 .IP "hmmaxd" 12
437 Host Memory Maximum Descriptors Entries indicates the number of
438 usable Host Memory Buffer Descriptor Entries.
439 .IP "nsetidmax" 12
440 NVM Set Identifier Maximum, defines the maximum value of a valid
441 NVM Set Identifier for any controller in the NVM subsystem.
442 .IP "endgidmax" 12
443 Endurance Group Identifier Maximum, defines the maximum value of
444 a valid Endurance Group Identifier for any controller in the NVM
445 subsystem.
446 .IP "anatt" 12
447 ANA Transition Time indicates the maximum amount of time, in
448 seconds, for a transition between ANA states or the maximum
449 amount of time, in seconds, that the controller reports the ANA
450 change state.
451 .IP "anacap" 12
452 Asymmetric Namespace Access Capabilities, see
453 \fIenum nvme_id_ctrl_anacap\fP.
454 .IP "anagrpmax" 12
455 ANA Group Identifier Maximum indicates the maximum value of a
456 valid ANA Group Identifier for any controller in the NVM
457 subsystem.
458 .IP "nanagrpid" 12
459 Number of ANA Group Identifiers indicates the number of ANA
460 groups supported by this controller.
461 .IP "pels" 12
462 Persistent Event Log Size indicates the maximum reportable size
463 for the Persistent Event Log.
464 .IP "domainid" 12
465 Domain Identifier indicates the identifier of the domain
466 that contains this controller.
467 .IP "kpioc" 12
468 Key Per I/O Capabilities (KPIOC), see \fIenum nvme_id_ctrl_kpioc\fP
469 .IP "rsvd359" 12
470 Reserved
471 .IP "mptfawr" 12
472 Maximum Processing Time for Firmware Activation Without Reset
473 (MPTFAWR). This field shall indicate the estimated maximum time
474 in 100 ms units required by the controller to process a Firmware
475 Commit command that specifies a value of 011b in the Commit
476 Action field
477 .IP "rsvd362" 12
478 Reserved
479 .IP "megcap" 12
480 Max Endurance Group Capacity indicates the maximum capacity
481 of a single Endurance Group.
482 .IP "tmpthha" 12
483 Temperature Threshold Hysteresis Attributes
484 .IP "rsvd385" 12
485 Reserved
486 .IP "cqt" 12
487 Command Quiesce Time (CQT). his field indicates the expected
488 worst-case time in 1 millisecond units for the controller to
489 quiesce all outstanding commands after a Keep Alive Timeout or
490 other communication loss.
491 .IP "rsvd388" 12
492 Reserved
493 .IP "sqes" 12
494 Submission Queue Entry Size, see \fIenum nvme_id_ctrl_sqes\fP.
495 .IP "cqes" 12
496 Completion Queue Entry Size, see \fIenum nvme_id_ctrl_cqes\fP.
497 .IP "maxcmd" 12
498 Maximum Outstanding Commands indicates the maximum number of
499 commands that the controller processes at one time for a
500 particular queue.
501 .IP "nn" 12
502 Number of Namespaces indicates the maximum value of a valid
503 nsid for the NVM subsystem. If the MNAN (\fIstruct nvme_id_ctrl\fP.mnan
504 field is cleared to 0h, then this field also indicates the
505 maximum number of namespaces supported by the NVM subsystem.
506 .IP "oncs" 12
507 Optional NVM Command Support, see \fIenum nvme_id_ctrl_oncs\fP.
508 .IP "fuses" 12
509 Fused Operation Support, see \fIenum nvme_id_ctrl_fuses\fP.
510 .IP "fna" 12
511 Format NVM Attributes, see \fIenum nvme_id_ctrl_fna\fP.
512 .IP "vwc" 12
513 Volatile Write Cache, see \fIenum nvme_id_ctrl_vwc\fP.
514 .IP "awun" 12
515 Atomic Write Unit Normal indicates the size of the write
516 operation guaranteed to be written atomically to the NVM across
517 all namespaces with any supported namespace format during normal
518 operation. This field is specified in logical blocks and is a
519 0's based value.
520 .IP "awupf" 12
521 Atomic Write Unit Power Fail indicates the size of the write
522 operation guaranteed to be written atomically to the NVM across
523 all namespaces with any supported namespace format during a
524 power fail or error condition. This field is specified in
525 logical blocks and is a 0’s based value.
526 .IP "icsvscc" 12
527 NVM Vendor Specific Command Configuration, see
528 \fIenum nvme_id_ctrl_nvscc\fP.
529 .IP "nwpc" 12
530 Namespace Write Protection Capabilities, see
531 \fIenum nvme_id_ctrl_nwpc\fP.
532 .IP "acwu" 12
533 Atomic Compare & Write Unit indicates the size of the write
534 operation guaranteed to be written atomically to the NVM across
535 all namespaces with any supported namespace format for a Compare
536 and Write fused operation. This field is specified in logical
537 blocks and is a 0’s based value.
538 .IP "ocfs" 12
539 Optional Copy Formats Supported, each bit n means controller
540 supports Copy Format n.
541 .IP "sgls" 12
542 SGL Support, see \fIenum nvme_id_ctrl_sgls\fP
543 .IP "mnan" 12
544 Maximum Number of Allowed Namespaces indicates the maximum
545 number of namespaces supported by the NVM subsystem.
546 .IP "maxdna" 12
547 Maximum Domain Namespace Attachments indicates the maximum
548 of the sum of the number of namespaces attached to each I/O
549 controller in the Domain.
550 .IP "maxcna" 12
551 Maximum I/O Controller Namespace Attachments indicates the
552 maximum number of namespaces that are allowed to be attached to
553 this I/O controller.
554 .IP "oaqd" 12
555 Optimal Aggregated Queue Depth indicates the recommended maximum
556 total number of outstanding I/O commands across all I/O queues
557 on the controller for optimal operation.
558 .IP "rhiri" 12
559 Recommended Host-Initiated Refresh Interval (RHIRI). If the
560 Host-Initiated Refresh capability is supported, then this field
561 indicates the recommended time interval in days from last power
562 down to the time at which the host should initiate the
563 Host-Initiated Refresh operation. If this field is cleared to
564 0h, then this field is not reported.
565 .IP "hirt" 12
566 Host-Initiated Refresh Time (HIRT). If the Host-Initiated
567 Refresh capability is supported, then this field indicates the
568 nominal amount of time in minutes that the controller takes to
569 complete the Host-Initiated Refresh operation. If this field is
570 cleared to 0h, then this field is not reported.
571 .IP "cmmrtd" 12
572 Controller Maximum Memory Range Tracking Descriptors indicates
573 the maximum number of Memory Range Tracking Descriptors the
574 controller supports.
575 .IP "nmmrtd" 12
576 NVM Subsystem Maximum Memory Range Tracking Descriptors
577 indicates the maximum number of Memory Range Tracking Descriptors
578 the NVM subsystem supports.
579 .IP "minmrtg" 12
580 Minimum Memory Range Tracking Granularity indicates the minimum
581 value supported in the Requested Memory Range Tracking
582 Granularity (RMRTG) field of the Track Memory Ranges data
583 structure.
584 .IP "maxmrtg" 12
585 Maximum Memory Range Tracking Granularity indicates the maximum
586 value supported in the Requested Memory Range Tracking
587 Granularity (RMRTG) field of the Track Memory Ranges data
588 structure.
589 .IP "trattr" 12
590 Tracking Attributes indicates supported attributes for the Track Send
591 command and Track Receive command. see \fIenum nvme_id_ctrl_trattr\fP
592 .IP "rsvd577" 12
593 Reserved
594 .IP "mcudmq" 12
595 Maximum Controller User Data Migration Queues indicates the
596 maximum number of User Data Migration Queues supported by the
597 controller.
598 .IP "mnsudmq" 12
599 Maximum NVM Subsystem User Data Migration Queues indicates the
600 maximum number of User Data Migration Queues supported by the NVM
601 subsystem.
602 .IP "mcmr" 12
603 Maximum CDQ Memory Ranges indicates the maximum number of
604 memory ranges allowed to be specified by the PRP1 field of a
605 Controller Data Queue command.
606 .IP "nmcmr" 12
607 NVM Subsystem Maximum CDQ Memory Ranges indicates the maximum
608 number of memory ranges for all Controller Data Queues in the
609 NVM subsystem.
610 .IP "mcdqpc" 12
611 Maximum Controller Data Queue PRP Count indicates the maximum
612 number of PRPs allowed to be specified in the PRP list in the
613 Controller Data Queue command.
614 .IP "rsvd588" 12
615 Reserved
616 .IP "subnqn" 12
617 NVM Subsystem NVMe Qualified Name, UTF-8 null terminated string
618 .IP "rsvd1024" 12
619 Reserved
620 .IP "ioccsz" 12
621 I/O Queue Command Capsule Supported Size, defines the maximum
622 I/O command capsule size in 16 byte units.
623 .IP "iorcsz" 12
624 I/O Queue Response Capsule Supported Size, defines the maximum
625 I/O response capsule size in 16 byte units.
626 .IP "icdoff" 12
627 In Capsule Data Offset, defines the offset where data starts
628 within a capsule. This value is applicable to I/O Queues only.
629 .IP "fcatt" 12
630 Fabrics Controller Attributes, see \fIenum nvme_id_ctrl_fcatt\fP.
631 .IP "msdbd" 12
632 Maximum SGL Data Block Descriptors indicates the maximum
633 number of SGL Data Block or Keyed SGL Data Block descriptors
634 that a host is allowed to place in a capsule. A value of 0h
635 indicates no limit.
636 .IP "ofcs" 12
637 Optional Fabric Commands Support, see \fIenum nvme_id_ctrl_ofcs\fP.
638 .IP "dctype" 12
639 Discovery Controller Type (DCTYPE). This field indicates what
640 type of Discovery controller the controller is (see enum
641 nvme_id_ctrl_dctype)
642 .IP "rsvd1807" 12
643 Reserved
644 .IP "psd" 12
645 Power State Descriptors, see \fIstruct nvme_id_psd\fP.
646 .IP "vs" 12
647 Vendor Specific