Debian Codegraph @

doc/man/nvme_lm_migration_recv_fields.2

raw
1 .TH "libnvme" 9 "enum nvme_lm_migration_recv_fields" "November 2025" "API Manual" LINUX
2 .SH NAME
3 enum nvme_lm_migration_recv_fields \- Migration Receive command fields
4 .SH SYNOPSIS
5 enum nvme_lm_migration_recv_fields {
6 .br
7 .BI " NVME_LM_MIGRATION_RECV_MOS_SHIFT"
8 ,
9 .br
10 .br
11 .BI " NVME_LM_MIGRATION_RECV_MOS_MASK"
12 ,
13 .br
14 .br
15 .BI " NVME_LM_MIGRATION_RECV_SEL_SHIFT"
16 ,
17 .br
18 .br
19 .BI " NVME_LM_MIGRATION_RECV_SEL_MASK"
20 ,
21 .br
22 .br
23 .BI " NVME_LM_SEL_GET_CONTROLLER_STATE"
24 ,
25 .br
26 .br
27 .BI " NVME_LM_MIGRATION_RECV_UIDX_SHIFT"
28 ,
29 .br
30 .br
31 .BI " NVME_LM_MIGRATION_RECV_UIDX_MASK"
32 ,
33 .br
34 .br
35 .BI " NVME_LM_GET_CONTROLLER_STATE_CSVI_SHIFT"
36 ,
37 .br
38 .br
39 .BI " NVME_LM_GET_CONTROLLER_STATE_CSVI_MASK"
40 ,
41 .br
42 .br
43 .BI " NVME_LM_GET_CONTROLLER_STATE_CSUIDXP_SHIFT"
44 ,
45 .br
46 .br
47 .BI " NVME_LM_GET_CONTROLLER_STATE_CSUIDXP_MASK"
48 ,
49 .br
50 .br
51 .BI " NVME_LM_GET_CONTROLLER_STATE_CSUUIDI_SHIFT"
52 ,
53 .br
54 .br
55 .BI " NVME_LM_GET_CONTROLLER_STATE_CSUUIDI_MASK"
56 ,
57 .br
58 .br
59 .BI " NVME_LM_GET_CONTROLLER_STATE_CNTLID_SHIFT"
60 ,
61 .br
62 .br
63 .BI " NVME_LM_GET_CONTROLLER_STATE_CNTLID_MASK"
64 ,
65 .br
66 .br
67 .BI " NVME_LM_GET_CONTROLLER_STATE_CSUP"
68
69 };
70 .SH Constants
71 .IP "NVME_LM_MIGRATION_RECV_MOS_SHIFT" 12
72 Shift amount to set Management Specific Operation
73 (MOS) field
74 .IP "NVME_LM_MIGRATION_RECV_MOS_MASK" 12
75 Mask to set MOS field
76 .IP "NVME_LM_MIGRATION_RECV_SEL_SHIFT" 12
77 Shift amount to set Select (SEL) field
78 .IP "NVME_LM_MIGRATION_RECV_SEL_MASK" 12
79 Mask to set SEL field
80 .IP "NVME_LM_SEL_GET_CONTROLLER_STATE" 12
81 Get Controller State select option
82 .IP "NVME_LM_MIGRATION_RECV_UIDX_SHIFT" 12
83 Shift to set UUID Index (UIDX)
84 .IP "NVME_LM_MIGRATION_RECV_UIDX_MASK" 12
85 Mask to set UIDX
86 .IP "NVME_LM_GET_CONTROLLER_STATE_CSVI_SHIFT" 12
87 Shift amount to set Controller State Version Index
88 (CSVI) relative to MOS
89 .IP "NVME_LM_GET_CONTROLLER_STATE_CSVI_MASK" 12
90 Mask to set CSVI relative to MOS
91 .IP "NVME_LM_GET_CONTROLLER_STATE_CSUIDXP_SHIFT" 12
92 Shift amount to set Controller State UUID Index
93 Parameter (CSUIDXP)
94 .IP "NVME_LM_GET_CONTROLLER_STATE_CSUIDXP_MASK" 12
95 Mask to set CSUIDXP
96 .IP "NVME_LM_GET_CONTROLLER_STATE_CSUUIDI_SHIFT" 12
97 Shift amount to set Controller State UUID Index
98 (CSUUIDI)
99 .IP "NVME_LM_GET_CONTROLLER_STATE_CSUUIDI_MASK" 12
100 Mask to set CSUUIDI
101 .IP "NVME_LM_GET_CONTROLLER_STATE_CNTLID_SHIFT" 12
102 Shift amount to set Controller ID (CNTLID)
103 .IP "NVME_LM_GET_CONTROLLER_STATE_CNTLID_MASK" 12