Debian Codegraph @

doc/man/nvme_cc.2

raw
1 .TH "libnvme" 9 "enum nvme_cc" "November 2025" "API Manual" LINUX
2 .SH NAME
3 enum nvme_cc \- This field indicates the controller configuration
4 .SH SYNOPSIS
5 enum nvme_cc {
6 .br
7 .BI " NVME_CC_EN_SHIFT"
8 ,
9 .br
10 .br
11 .BI " NVME_CC_CSS_SHIFT"
12 ,
13 .br
14 .br
15 .BI " NVME_CC_MPS_SHIFT"
16 ,
17 .br
18 .br
19 .BI " NVME_CC_AMS_SHIFT"
20 ,
21 .br
22 .br
23 .BI " NVME_CC_SHN_SHIFT"
24 ,
25 .br
26 .br
27 .BI " NVME_CC_IOSQES_SHIFT"
28 ,
29 .br
30 .br
31 .BI " NVME_CC_IOCQES_SHIFT"
32 ,
33 .br
34 .br
35 .BI " NVME_CC_CRIME_SHIFT"
36 ,
37 .br
38 .br
39 .BI " NVME_CC_EN_MASK"
40 ,
41 .br
42 .br
43 .BI " NVME_CC_CSS_MASK"
44 ,
45 .br
46 .br
47 .BI " NVME_CC_MPS_MASK"
48 ,
49 .br
50 .br
51 .BI " NVME_CC_AMS_MASK"
52 ,
53 .br
54 .br
55 .BI " NVME_CC_SHN_MASK"
56 ,
57 .br
58 .br
59 .BI " NVME_CC_CRIME_MASK"
60 ,
61 .br
62 .br
63 .BI " NVME_CC_IOSQES_MASK"
64 ,
65 .br
66 .br
67 .BI " NVME_CC_IOCQES_MASK"
68 ,
69 .br
70 .br
71 .BI " NVME_CC_CSS_NVM"
72 ,
73 .br
74 .br
75 .BI " NVME_CC_CSS_CSI"
76 ,
77 .br
78 .br
79 .BI " NVME_CC_CSS_ADMIN"
80 ,
81 .br
82 .br
83 .BI " NVME_CC_AMS_RR"
84 ,
85 .br
86 .br
87 .BI " NVME_CC_AMS_WRRU"
88 ,
89 .br
90 .br
91 .BI " NVME_CC_AMS_VS"
92 ,
93 .br
94 .br
95 .BI " NVME_CC_SHN_NONE"
96 ,
97 .br
98 .br
99 .BI " NVME_CC_SHN_NORMAL"
100 ,
101 .br
102 .br
103 .BI " NVME_CC_SHN_ABRUPT"
104 ,
105 .br
106 .br
107 .BI " NVME_CC_CRWME"
108 ,
109 .br
110 .br
111 .BI " NVME_CC_CRIME"
112
113 };
114 .SH Constants
115 .IP "NVME_CC_EN_SHIFT" 12
116 Shift amount to get the enable
117 .IP "NVME_CC_CSS_SHIFT" 12
118 Shift amount to get the I/O command set selected
119 .IP "NVME_CC_MPS_SHIFT" 12
120 Shift amount to get the memory page size
121 .IP "NVME_CC_AMS_SHIFT" 12
122 Shift amount to get the arbitration mechanism selected
123 .IP "NVME_CC_SHN_SHIFT" 12
124 Shift amount to get the shutdown notification
125 .IP "NVME_CC_IOSQES_SHIFT" 12
126 Shift amount to get the I/O submission queue entry size
127 .IP "NVME_CC_IOCQES_SHIFT" 12
128 Shift amount to get the I/O completion queue entry size
129 .IP "NVME_CC_CRIME_SHIFT" 12
130 Shift amount to get the controller ready independent of media enable
131 .IP "NVME_CC_EN_MASK" 12
132 Mask to get the enable
133 .IP "NVME_CC_CSS_MASK" 12
134 Mask to get the I/O command set selected
135 .IP "NVME_CC_MPS_MASK" 12
136 Mask to get the memory page size
137 .IP "NVME_CC_AMS_MASK" 12
138 Mask to get the arbitration mechanism selected
139 .IP "NVME_CC_SHN_MASK" 12
140 Mask to get the shutdown notification
141 .IP "NVME_CC_CRIME_MASK" 12
142 Mask to get the I/O submission queue entry size
143 .IP "NVME_CC_IOSQES_MASK" 12
144 Mask to get the I/O completion queue entry size
145 .IP "NVME_CC_IOCQES_MASK" 12
146 Mask to get the controller ready independent of media enable
147 .IP "NVME_CC_CSS_NVM" 12
148 NVM command set
149 .IP "NVME_CC_CSS_CSI" 12
150 All supported I/O command sets
151 .IP "NVME_CC_CSS_ADMIN" 12
152 Admin command set only
153 .IP "NVME_CC_AMS_RR" 12
154 Round robin
155 .IP "NVME_CC_AMS_WRRU" 12
156 Weighted round robin with urgent priority class
157 .IP "NVME_CC_AMS_VS" 12
158 Vendor specific
159 .IP "NVME_CC_SHN_NONE" 12
160 No notification; no effect
161 .IP "NVME_CC_SHN_NORMAL" 12
162 Normal shutdown notification
163 .IP "NVME_CC_SHN_ABRUPT" 12
164 Abrupt shutdown notification
165 .IP "NVME_CC_CRWME" 12
166 Controller ready with media enable
167 .IP "NVME_CC_CRIME" 12
168 Controller ready independent of media enable