| 1 |
WAXS processing and merging |
| 2 |
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ |
| 3 |
|
| 4 |
Several SAXS beamlines use two (or more) detectors to collect different q regions. For example, |
| 5 |
the MacCHESS G1 beamline used dual Pilatus detectors to measure SAXS and WAXS from *q* ~0.008 – 0.75 |
| 6 |
Å\ :sup:`-1`\ . The SAXS detector has *q* ~< 0.25 Å\ :sup:`-1` and the wide-angle scattering |
| 7 |
(WAXS) data has *q* >~ 0.25 Å\ :sup:`-1`\ . All of the data that you have been working with |
| 8 |
so far has been SAXS data. Some experiments can make use of the WAXS data. In this part of the |
| 9 |
tutorial you will learn the basics of processing it. |
| 10 |
|
| 11 |
A video version of this tutorial is available: |
| 12 |
|
| 13 |
.. raw:: html |
| 14 |
|
| 15 |
<style>.embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }</style><div class='embed-container'><iframe src='https://www.youtube.com/embed/UZCGXjQdk7Y' frameborder='0' allowfullscreen></iframe></div> |
| 16 |
|
| 17 |
The written version of the tutorial follows. |
| 18 |
|
| 19 |
#. Clear any data in RAW. |
| 20 |
|
| 21 |
#. Navigate to the **standards_data** and load the **WAXS.cfg** file. |
| 22 |
|
| 23 |
#. Plot the **lysbuff2** **PIL3** and **lys2** **PIL3** files. These are the images from the WAXS |
| 24 |
detector. Average these files and create a subtracted WAXS scattering profile. |
| 25 |
|
| 26 |
* *Tip:* Filenames should be **lysbuff2_<stuff>_PIL3_<stuff>.tiff** |
| 27 |
and **lys2_<stuff>_PIL3_<stuff>.tiff**\ . |
| 28 |
|
| 29 |
#. Load the saved subtracted SAXS scattering profile for the lysozyme standards data. |
| 30 |
|
| 31 |
* *Note:* You should have saved it in the **standards_data** folder, and it is likely |
| 32 |
named **S_A_lys2_A9_17_001_0000.dat**\ . |
| 33 |
|
| 34 |
#. Move the SAXS scattering profile you just loaded to the bottom plot by right clicking |
| 35 |
on it in the Profiles list and selecting “Move to bottom plot.” |
| 36 |
|
| 37 |
#. The WAXS data is not on the same scale as the SAXS data. For this data, the known scale |
| 38 |
factor to apply is 0.000014 to the WAXS data. |
| 39 |
|
| 40 |
* *Note:* The scale factor can be calculated as the ratio of solid angles subtended |
| 41 |
by the pixels on the SAXS and WAXS detectors, plus any scale factor for absolute |
| 42 |
calibration and normalization included for one curve but not the other. |
| 43 |
|
| 44 |
#. Star the WAXS data. Right click on the SAXS data and select Other Operations -> Merge. |
| 45 |
This will create a new merged scattering profile. The new file will have the |
| 46 |
prefix **M_** to indicate it is a merged file. |
| 47 |
|
| 48 |
* *Tip:* If you can’t see it, that’s probably because it appeared on the upper plot, |
| 49 |
and is hidden by the very large intensities of the averaged WAXS files. Either try |
| 50 |
hiding those, or move the Merged curve to the lower plot. |