| 1 |
What: /sys/bus/iio/devices/iio:deviceX/in_proximity<id>_setup |
| 2 |
Date: November 2021 |
| 3 |
KernelVersion: 5.17 |
| 4 |
Contact: Gwendal Grignou <[email protected]> |
| 5 |
Description: |
| 6 |
SX9324 has 3 inputs, CS0, CS1 and CS2. Hardware layout |
| 7 |
defines if the input is |
| 8 |
|
| 9 |
+ not connected (HZ), |
| 10 |
+ grounded (GD), |
| 11 |
+ connected to an antenna where it can act as a base |
| 12 |
(DS - data shield), or measured input (MI). |
| 13 |
|
| 14 |
The sensor rotates measurement across 4 phases |
| 15 |
(PH0, PH1, PH2, PH3), where the inputs are configured |
| 16 |
and then measured. |
| 17 |
|
| 18 |
By default, during the first phase, [PH0], CS0 is measured, |
| 19 |
while CS1 and CS2 are used as shields. |
| 20 |
`cat in_proximity0_setup` returns "MI,DS,DS". |
| 21 |
[PH1], CS1 is measured, CS0 and CS2 are shield: |
| 22 |
`cat in_proximity1_setup` returns "DS,MI,DS". |
| 23 |
[PH2], CS2 is measured, CS0 and CS1 are shield: |
| 24 |
`cat in_proximity1_setup` returns "DS,DS,MI". |
| 25 |
[PH3], CS1 and CS2 are measured (combo mode): |
| 26 |
`cat in_proximity1_setup` returns "DS,MI,MI". |
| 27 |
|
| 28 |
Note, these are the chip default. Hardware layout will most |
| 29 |