| 1 |
What: /sys/bus/iio/devices/iio:deviceX/ac_excitation_en |
| 2 |
KernelVersion: |
| 3 |
Contact: [email protected] |
| 4 |
Description: |
| 5 |
This attribute, if available, is used to enable the AC |
| 6 |
excitation mode found on some converters. In ac excitation mode, |
| 7 |
the polarity of the excitation voltage is reversed on |
| 8 |
alternate cycles, to eliminate DC errors. |
| 9 |
|
| 10 |
What: /sys/bus/iio/devices/iio:deviceX/bridge_switch_en |
| 11 |
KernelVersion: |
| 12 |
Contact: [email protected] |
| 13 |
Description: |
| 14 |
This attribute, if available, is used to close or open the |
| 15 |
bridge power down switch found on some converters. |
| 16 |
In bridge applications, such as strain gauges and load cells, |
| 17 |
the bridge itself consumes the majority of the current in the |
| 18 |
system. To minimize the current consumption of the system, |
| 19 |
the bridge can be disconnected (when it is not being used |
| 20 |
using the bridge_switch_en attribute. |
| 21 |
|
| 22 |
What: /sys/bus/iio/devices/iio:deviceX/in_voltage2-voltage2_shorted_raw |
| 23 |
KernelVersion: |
| 24 |
Contact: [email protected] |
| 25 |
Description: |
| 26 |
Measure voltage from AIN2 pin connected to AIN(+) |
| 27 |
and AIN(-) shorted. |