| 1 |
======================= |
| 2 |
Energy Aware Scheduling |
| 3 |
======================= |
| 4 |
|
| 5 |
1. Introduction |
| 6 |
--------------- |
| 7 |
|
| 8 |
Energy Aware Scheduling (or EAS) gives the scheduler the ability to predict |
| 9 |
the impact of its decisions on the energy consumed by CPUs. EAS relies on an |
| 10 |
Energy Model (EM) of the CPUs to select an energy efficient CPU for each task, |
| 11 |
with a minimal impact on throughput. This document aims at providing an |
| 12 |
introduction on how EAS works, what are the main design decisions behind it, and |
| 13 |
details what is needed to get it to run. |
| 14 |
|
| 15 |
Before going any further, please note that at the time of writing:: |
| 16 |
|
| 17 |
/!\ EAS does not support platforms with symmetric CPU topologies /!\ |
| 18 |
|
| 19 |
EAS operates only on heterogeneous CPU topologies (such as Arm big.LITTLE) |
| 20 |
because this is where the potential for saving energy through scheduling is |
| 21 |
the highest. |
| 22 |
|
| 23 |
The actual EM used by EAS is _not_ maintained by the scheduler, but by a |
| 24 |
dedicated framework. For details about this framework and what it provides, |
| 25 |
please refer to its documentation (see Documentation/power/energy-model.rst). |
| 26 |
|
| 27 |
|
| 28 |
2. Background and Terminology |
| 29 |
----------------------------- |
| 30 |
|
| 31 |
To make it clear from the start: |
| 32 |
- energy = [joule] (resource like a battery on powered devices) |
| 33 |
- power = energy/time = [joule/second] = [watt] |
| 34 |
|
| 35 |
The goal of EAS is to minimize energy, while still getting the job done. That |
| 36 |
is, we want to maximize:: |
| 37 |
|
| 38 |
performance [inst/s] |
| 39 |
-------------------- |
| 40 |
power [W] |
| 41 |
|
| 42 |
which is equivalent to minimizing:: |
| 43 |
|
| 44 |
energy [J] |
| 45 |
----------- |
| 46 |
instruction |
| 47 |
|
| 48 |
while still getting 'good' performance. It is essentially an alternative |
| 49 |
optimization objective to the current performance-only objective for the |
| 50 |
scheduler. This alternative considers two objectives: energy-efficiency and |
| 51 |
performance. |
| 52 |
|
| 53 |
The idea behind introducing an EM is to allow the scheduler to evaluate the |
| 54 |
implications of its decisions rather than blindly applying energy-saving |
| 55 |
techniques that may have positive effects only on some platforms. At the same |
| 56 |
time, the EM must be as simple as possible to minimize the scheduler latency |
| 57 |
impact. |
| 58 |
|
| 59 |
In short, EAS changes the way CFS tasks are assigned to CPUs. When it is time |
| 60 |
for the scheduler to decide where a task should run (during wake-up), the EM |
| 61 |
is used to break the tie between several good CPU candidates and pick the one |
| 62 |
that is predicted to yield the best energy consumption without harming the |
| 63 |
system's throughput. The predictions made by EAS rely on specific elements of |
| 64 |
knowledge about the platform's topology, which include the 'capacity' of CPUs, |
| 65 |
and their respective energy costs. |
| 66 |
|
| 67 |
|
| 68 |
3. Topology information |
| 69 |
----------------------- |
| 70 |
|
| 71 |
EAS (as well as the rest of the scheduler) uses the notion of 'capacity' to |
| 72 |
differentiate CPUs with different computing throughput. The 'capacity' of a CPU |
| 73 |
represents the amount of work it can absorb when running at its highest |
| 74 |
frequency compared to the most capable CPU of the system. Capacity values are |
| 75 |
normalized in a 1024 range, and are comparable with the utilization signals of |
| 76 |
tasks and CPUs computed by the Per-Entity Load Tracking (PELT) mechanism. Thanks |
| 77 |
to capacity and utilization values, EAS is able to estimate how big/busy a |
| 78 |
task/CPU is, and to take this into consideration when evaluating performance vs |
| 79 |
energy trade-offs. The capacity of CPUs is provided via arch-specific code |
| 80 |
through the arch_scale_cpu_capacity() callback. |
| 81 |
|
| 82 |
The rest of platform knowledge used by EAS is directly read from the Energy |
| 83 |
Model (EM) framework. The EM of a platform is composed of a power cost table |
| 84 |
per 'performance domain' in the system (see Documentation/power/energy-model.rst |
| 85 |
for further details about performance domains). |
| 86 |
|
| 87 |
The scheduler manages references to the EM objects in the topology code when the |
| 88 |
scheduling domains are built, or re-built. For each root domain (rd), the |
| 89 |
scheduler maintains a singly linked list of all performance domains intersecting |
| 90 |
the current rd->span. Each node in the list contains a pointer to a struct |
| 91 |
em_perf_domain as provided by the EM framework. |
| 92 |
|
| 93 |
The lists are attached to the root domains in order to cope with exclusive |
| 94 |
cpuset configurations. Since the boundaries of exclusive cpusets do not |
| 95 |
necessarily match those of performance domains, the lists of different root |
| 96 |
domains can contain duplicate elements. |
| 97 |
|
| 98 |
Example 1. |
| 99 |
Let us consider a platform with 12 CPUs, split in 3 performance domains |
| 100 |
(pd0, pd4 and pd8), organized as follows:: |
| 101 |
|
| 102 |
CPUs: 0 1 2 3 4 5 6 7 8 9 10 11 |
| 103 |
PDs: |--pd0--|--pd4--|---pd8---| |
| 104 |
RDs: |----rd1----|-----rd2-----| |
| 105 |
|
| 106 |
Now, consider that userspace decided to split the system with two |
| 107 |
exclusive cpusets, hence creating two independent root domains, each |
| 108 |
containing 6 CPUs. The two root domains are denoted rd1 and rd2 in the |
| 109 |
above figure. Since pd4 intersects with both rd1 and rd2, it will be |
| 110 |
present in the linked list '->pd' attached to each of them: |
| 111 |
|
| 112 |
* rd1->pd: pd0 -> pd4 |
| 113 |
* rd2->pd: pd4 -> pd8 |
| 114 |
|
| 115 |
Please note that the scheduler will create two duplicate list nodes for |
| 116 |
pd4 (one for each list). However, both just hold a pointer to the same |
| 117 |
shared data structure of the EM framework. |
| 118 |
|
| 119 |
Since the access to these lists can happen concurrently with hotplug and other |
| 120 |
things, they are protected by RCU, like the rest of topology structures |
| 121 |
manipulated by the scheduler. |
| 122 |
|
| 123 |
EAS also maintains a static key (sched_energy_present) which is enabled when at |
| 124 |
least one root domain meets all conditions for EAS to start. Those conditions |
| 125 |
are summarized in Section 6. |
| 126 |
|
| 127 |
|
| 128 |
4. Energy-Aware task placement |
| 129 |
------------------------------ |
| 130 |
|
| 131 |
EAS overrides the CFS task wake-up balancing code. It uses the EM of the |
| 132 |
platform and the PELT signals to choose an energy-efficient target CPU during |
| 133 |
wake-up balance. When EAS is enabled, select_task_rq_fair() calls |
| 134 |
find_energy_efficient_cpu() to do the placement decision. This function looks |
| 135 |
for the CPU with the highest spare capacity (CPU capacity - CPU utilization) in |
| 136 |
each performance domain since it is the one which will allow us to keep the |
| 137 |
frequency the lowest. Then, the function checks if placing the task there could |
| 138 |
save energy compared to leaving it on prev_cpu, i.e. the CPU where the task ran |
| 139 |
in its previous activation. |
| 140 |
|
| 141 |
find_energy_efficient_cpu() uses compute_energy() to estimate what will be the |
| 142 |
energy consumed by the system if the waking task was migrated. compute_energy() |
| 143 |
looks at the current utilization landscape of the CPUs and adjusts it to |
| 144 |
'simulate' the task migration. The EM framework provides the em_pd_energy() API |
| 145 |
which computes the expected energy consumption of each performance domain for |
| 146 |
the given utilization landscape. |
| 147 |
|
| 148 |
An example of energy-optimized task placement decision is detailed below. |
| 149 |
|
| 150 |
Example 2. |
| 151 |
Let us consider a (fake) platform with 2 independent performance domains |
| 152 |
composed of two CPUs each. CPU0 and CPU1 are little CPUs; CPU2 and CPU3 |
| 153 |
are big. |
| 154 |
|
| 155 |
The scheduler must decide where to place a task P whose util_avg = 200 |
| 156 |
and prev_cpu = 0. |
| 157 |
|
| 158 |
The current utilization landscape of the CPUs is depicted on the graph |
| 159 |
below. CPUs 0-3 have a util_avg of 400, 100, 600 and 500 respectively |
| 160 |
Each performance domain has three Operating Performance Points (OPPs). |
| 161 |
The CPU capacity and power cost associated with each OPP is listed in |
| 162 |
the Energy Model table. The util_avg of P is shown on the figures |
| 163 |
below as 'PP':: |
| 164 |
|
| 165 |
CPU util. |
| 166 |
1024 - - - - - - - Energy Model |
| 167 |
+-----------+-------------+ |
| 168 |
| Little | Big | |
| 169 |
768 ============= +-----+-----+------+------+ |
| 170 |
| Cap | Pwr | Cap | Pwr | |
| 171 |
+-----+-----+------+------+ |
| 172 |
512 =========== - ##- - - - - | 170 | 50 | 512 | 400 | |
| 173 |
## ## | 341 | 150 | 768 | 800 | |
| 174 |
341 -PP - - - - ## ## | 512 | 300 | 1024 | 1700 | |
| 175 |
PP ## ## +-----+-----+------+------+ |
| 176 |
170 -## - - - - ## ## |
| 177 |
## ## ## ## |
| 178 |
------------ ------------- |
| 179 |
CPU0 CPU1 CPU2 CPU3 |
| 180 |
|
| 181 |
Current OPP: ===== Other OPP: - - - util_avg (100 each): ## |
| 182 |
|
| 183 |
|
| 184 |
find_energy_efficient_cpu() will first look for the CPUs with the |
| 185 |
maximum spare capacity in the two performance domains. In this example, |
| 186 |
CPU1 and CPU3. Then it will estimate the energy of the system if P was |
| 187 |
placed on either of them, and check if that would save some energy |
| 188 |
compared to leaving P on CPU0. EAS assumes that OPPs follow utilization |
| 189 |
(which is coherent with the behaviour of the schedutil CPUFreq |
| 190 |
governor, see Section 6. for more details on this topic). |
| 191 |
|
| 192 |
**Case 1. P is migrated to CPU1**:: |
| 193 |
|
| 194 |
1024 - - - - - - - |
| 195 |
|
| 196 |
Energy calculation: |
| 197 |
768 ============= * CPU0: 200 / 341 * 150 = 88 |
| 198 |
* CPU1: 300 / 341 * 150 = 131 |
| 199 |
* CPU2: 600 / 768 * 800 = 625 |
| 200 |
512 - - - - - - - ##- - - - - * CPU3: 500 / 768 * 800 = 520 |
| 201 |
## ## => total_energy = 1364 |
| 202 |
341 =========== ## ## |
| 203 |
PP ## ## |
| 204 |
170 -## - - PP- ## ## |
| 205 |
## ## ## ## |
| 206 |
------------ ------------- |
| 207 |
CPU0 CPU1 CPU2 CPU3 |
| 208 |
|
| 209 |
|
| 210 |
**Case 2. P is migrated to CPU3**:: |
| 211 |
|
| 212 |
1024 - - - - - - - |
| 213 |
|
| 214 |
Energy calculation: |
| 215 |
768 ============= * CPU0: 200 / 341 * 150 = 88 |
| 216 |
* CPU1: 100 / 341 * 150 = 43 |
| 217 |
PP * CPU2: 600 / 768 * 800 = 625 |
| 218 |
512 - - - - - - - ##- - -PP - * CPU3: 700 / 768 * 800 = 729 |
| 219 |
## ## => total_energy = 1485 |
| 220 |
341 =========== ## ## |
| 221 |
## ## |
| 222 |
170 -## - - - - ## ## |
| 223 |
## ## ## ## |
| 224 |
------------ ------------- |
| 225 |
CPU0 CPU1 CPU2 CPU3 |
| 226 |
|
| 227 |
|
| 228 |
**Case 3. P stays on prev_cpu / CPU 0**:: |
| 229 |
|
| 230 |
1024 - - - - - - - |
| 231 |
|
| 232 |
Energy calculation: |
| 233 |
768 ============= * CPU0: 400 / 512 * 300 = 234 |
| 234 |
* CPU1: 100 / 512 * 300 = 58 |
| 235 |
* CPU2: 600 / 768 * 800 = 625 |
| 236 |
512 =========== - ##- - - - - * CPU3: 500 / 768 * 800 = 520 |
| 237 |
## ## => total_energy = 1437 |
| 238 |
341 -PP - - - - ## ## |
| 239 |
PP ## ## |
| 240 |
170 -## - - - - ## ## |
| 241 |
## ## ## ## |
| 242 |
------------ ------------- |
| 243 |
CPU0 CPU1 CPU2 CPU3 |
| 244 |
|
| 245 |
|
| 246 |
From these calculations, the Case 1 has the lowest total energy. So CPU 1 |
| 247 |
is the best candidate from an energy-efficiency standpoint. |
| 248 |
|
| 249 |
Big CPUs are generally more power hungry than the little ones and are thus used |
| 250 |
mainly when a task doesn't fit the littles. However, little CPUs aren't always |
| 251 |
necessarily more energy-efficient than big CPUs. For some systems, the high OPPs |
| 252 |
of the little CPUs can be less energy-efficient than the lowest OPPs of the |
| 253 |
bigs, for example. So, if the little CPUs happen to have enough utilization at |
| 254 |
a specific point in time, a small task waking up at that moment could be better |
| 255 |
off executing on the big side in order to save energy, even though it would fit |
| 256 |
on the little side. |
| 257 |
|
| 258 |
And even in the case where all OPPs of the big CPUs are less energy-efficient |
| 259 |
than those of the little, using the big CPUs for a small task might still, under |
| 260 |
specific conditions, save energy. Indeed, placing a task on a little CPU can |
| 261 |
result in raising the OPP of the entire performance domain, and that will |
| 262 |
increase the cost of the tasks already running there. If the waking task is |
| 263 |
placed on a big CPU, its own execution cost might be higher than if it was |
| 264 |
running on a little, but it won't impact the other tasks of the little CPUs |
| 265 |
which will keep running at a lower OPP. So, when considering the total energy |
| 266 |
consumed by CPUs, the extra cost of running that one task on a big core can be |
| 267 |
smaller than the cost of raising the OPP on the little CPUs for all the other |
| 268 |
tasks. |
| 269 |
|
| 270 |
The examples above would be nearly impossible to get right in a generic way, and |
| 271 |
for all platforms, without knowing the cost of running at different OPPs on all |
| 272 |
CPUs of the system. Thanks to its EM-based design, EAS should cope with them |
| 273 |
correctly without too many troubles. However, in order to ensure a minimal |
| 274 |
impact on throughput for high-utilization scenarios, EAS also implements another |
| 275 |
mechanism called 'over-utilization'. |
| 276 |
|
| 277 |
|
| 278 |
5. Over-utilization |
| 279 |
------------------- |
| 280 |
|
| 281 |
From a general standpoint, the use-cases where EAS can help the most are those |
| 282 |
involving a light/medium CPU utilization. Whenever long CPU-bound tasks are |
| 283 |
being run, they will require all of the available CPU capacity, and there isn't |
| 284 |
much that can be done by the scheduler to save energy without severely harming |
| 285 |
throughput. In order to avoid hurting performance with EAS, CPUs are flagged as |
| 286 |
'over-utilized' as soon as they are used at more than 80% of their compute |
| 287 |
capacity. As long as no CPUs are over-utilized in a root domain, load balancing |
| 288 |
is disabled and EAS overrides the wake-up balancing code. EAS is likely to load |
| 289 |
the most energy efficient CPUs of the system more than the others if that can be |
| 290 |
done without harming throughput. So, the load-balancer is disabled to prevent |
| 291 |
it from breaking the energy-efficient task placement found by EAS. It is safe to |
| 292 |
do so when the system isn't overutilized since being below the 80% tipping point |
| 293 |
implies that: |
| 294 |
|
| 295 |
a. there is some idle time on all CPUs, so the utilization signals used by |
| 296 |
EAS are likely to accurately represent the 'size' of the various tasks |
| 297 |
in the system; |
| 298 |
b. all tasks should already be provided with enough CPU capacity, |
| 299 |
regardless of their nice values; |
| 300 |
c. since there is spare capacity all tasks must be blocking/sleeping |
| 301 |
regularly and balancing at wake-up is sufficient. |
| 302 |
|
| 303 |
As soon as one CPU goes above the 80% tipping point, at least one of the three |
| 304 |
assumptions above becomes incorrect. In this scenario, the 'overutilized' flag |
| 305 |
is raised for the entire root domain, EAS is disabled, and the load-balancer is |
| 306 |
re-enabled. By doing so, the scheduler falls back onto load-based algorithms for |
| 307 |
wake-up and load balance under CPU-bound conditions. This provides a better |
| 308 |
respect of the nice values of tasks. |
| 309 |
|
| 310 |
Since the notion of overutilization largely relies on detecting whether or not |
| 311 |
there is some idle time in the system, the CPU capacity 'stolen' by higher |
| 312 |
(than CFS) scheduling classes (as well as IRQ) must be taken into account. As |
| 313 |
such, the detection of overutilization accounts for the capacity used not only |
| 314 |
by CFS tasks, but also by the other scheduling classes and IRQ. |
| 315 |
|
| 316 |
|
| 317 |
6. Dependencies and requirements for EAS |
| 318 |
---------------------------------------- |
| 319 |
|
| 320 |
Energy Aware Scheduling depends on the CPUs of the system having specific |
| 321 |
hardware properties and on other features of the kernel being enabled. This |
| 322 |
section lists these dependencies and provides hints as to how they can be met. |
| 323 |
|
| 324 |
|
| 325 |
6.1 - Asymmetric CPU topology |
| 326 |
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ |
| 327 |
|
| 328 |
|
| 329 |
As mentioned in the introduction, EAS is only supported on platforms with |
| 330 |
asymmetric CPU topologies for now. This requirement is checked at run-time by |
| 331 |
looking for the presence of the SD_ASYM_CPUCAPACITY_FULL flag when the scheduling |
| 332 |
domains are built. |
| 333 |
|
| 334 |
See Documentation/scheduler/sched-capacity.rst for requirements to be met for this |
| 335 |
flag to be set in the sched_domain hierarchy. |
| 336 |
|
| 337 |
Please note that EAS is not fundamentally incompatible with SMP, but no |
| 338 |
significant savings on SMP platforms have been observed yet. This restriction |
| 339 |
could be amended in the future if proven otherwise. |
| 340 |
|
| 341 |
|
| 342 |
6.2 - Energy Model presence |
| 343 |
^^^^^^^^^^^^^^^^^^^^^^^^^^^ |
| 344 |
|
| 345 |
EAS uses the EM of a platform to estimate the impact of scheduling decisions on |
| 346 |
energy. So, your platform must provide power cost tables to the EM framework in |
| 347 |
order to make EAS start. To do so, please refer to documentation of the |
| 348 |
independent EM framework in Documentation/power/energy-model.rst. |
| 349 |
|
| 350 |
Please also note that the scheduling domains need to be re-built after the |
| 351 |
EM has been registered in order to start EAS. |
| 352 |
|
| 353 |
EAS uses the EM to make a forecasting decision on energy usage and thus it is |
| 354 |
more focused on the difference when checking possible options for task |
| 355 |
placement. For EAS it doesn't matter whether the EM power values are expressed |
| 356 |
in milli-Watts or in an 'abstract scale'. |
| 357 |
|
| 358 |
|
| 359 |
6.3 - Energy Model complexity |
| 360 |
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ |
| 361 |
|
| 362 |
EAS does not impose any complexity limit on the number of PDs/OPPs/CPUs but |
| 363 |
restricts the number of CPUs to EM_MAX_NUM_CPUS to prevent overflows during |
| 364 |
the energy estimation. |
| 365 |
|
| 366 |
|
| 367 |
6.4 - Schedutil governor |
| 368 |
^^^^^^^^^^^^^^^^^^^^^^^^ |
| 369 |
|
| 370 |
EAS tries to predict at which OPP will the CPUs be running in the close future |
| 371 |
in order to estimate their energy consumption. To do so, it is assumed that OPPs |
| 372 |
of CPUs follow their utilization. |
| 373 |
|
| 374 |
Although it is very difficult to provide hard guarantees regarding the accuracy |
| 375 |
of this assumption in practice (because the hardware might not do what it is |
| 376 |
told to do, for example), schedutil as opposed to other CPUFreq governors at |
| 377 |
least _requests_ frequencies calculated using the utilization signals. |
| 378 |
Consequently, the only sane governor to use together with EAS is schedutil, |
| 379 |
because it is the only one providing some degree of consistency between |
| 380 |
frequency requests and energy predictions. |
| 381 |
|
| 382 |
Using EAS with any other governor than schedutil is not supported. |
| 383 |
|
| 384 |
|
| 385 |
6.5 Scale-invariant utilization signals |
| 386 |
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ |
| 387 |
|
| 388 |
In order to make accurate predictions across CPUs and for all performance |
| 389 |
states, EAS needs frequency-invariant and CPU-invariant PELT signals. These can |
| 390 |
be obtained using the architecture-defined arch_scale{cpu,freq}_capacity() |
| 391 |
callbacks. |
| 392 |
|
| 393 |
Using EAS on a platform that doesn't implement these two callbacks is not |
| 394 |
supported. |
| 395 |
|
| 396 |
|
| 397 |
6.6 Multithreading (SMT) |
| 398 |
^^^^^^^^^^^^^^^^^^^^^^^^ |
| 399 |
|
| 400 |
EAS in its current form is SMT unaware and is not able to leverage |
| 401 |
multithreaded hardware to save energy. EAS considers threads as independent |
| 402 |
CPUs, which can actually be counter-productive for both performance and energy. |
| 403 |
|
| 404 |
EAS on SMT is not supported. |