Debian Codegraph @

src/bonsai/test/bim/feature/qto.feature

raw
1 @qto
2 Feature: Qto
3
4 Scenario: Calculate circle radius
5 Given an empty Blender session
6 And I add a cube
7 And the object "Cube" is selected
8 And I look at the "Simple Quantity Calculator" panel
9 When I click "Calculate Circle Radius"
10 Then I see the "Results" property is "1.732"
11
12 Scenario: Calculate edge lengths
13 Given an empty Blender session
14 And I add a cube
15 And the object "Cube" is selected
16 And I look at the "Simple Quantity Calculator" panel
17 When I click "Calculate Edge Lengths"
18 Then I see the "Results" property is "24.0"
19
20 Scenario: Calculate face areas
21 Given an empty Blender session
22 And I add a cube
23 And the object "Cube" is selected
24 And I look at the "Simple Quantity Calculator" panel
25 When I click "Calculate Face Areas"
26 Then I see the "Results" property is "24.0"
27
28 Scenario: Calculate object volumes
29 Given an empty Blender session
30 And I add a cube
31 And the object "Cube" is selected
32 And I look at the "Simple Quantity Calculator" panel
33 When I click "Calculate Object Volumes"
34 Then I see the "Results" property is "8.0"
35
36 Scenario: Execute qto method - formwork areas
37 Given an empty Blender session
38 And I add a cube
39 And I add a cube of size "1" at "1,0,0"
40 And the object "Cube" is selected
41 And additionally the object "Cube.001" is selected
42 When I press "bim.calculate_formwork_area"
43 Then "scene.BIMQtoProperties.qto_result" is "21.5"
44
45 Scenario: Execute qto method - side formwork areas
46 Given an empty Blender session
47 And I add a cube
48 And the object "Cube" is selected
49 When I press "bim.calculate_side_formwork_area"
50 Then "scene.BIMQtoProperties.qto_result" is "16.0"
51
52 Scenario: Perform quantity take-off - no objects
53 Given an empty IFC project
54 When I look at the "Quantity Take-off" panel
55 Then I see "Quantifying All Objects"
56 When I click "Perform Quantity Take-off"
57 Then nothing happens
58
59 Scenario: Perform quantity take-off
60 Given an empty IFC project
61 And I add a cube
62 And the object "Cube" is selected
63 And I look at the "Class" panel
64 And I set the "Products" property to "IfcElement"
65 And I set the "Class" property to "IfcWall"
66 And I click "Assign IFC Class"
67 And I look at the "Quantity Take-off" panel
68 When I see "Quantifying 1 Selected Objects"
69 And I click "Perform Quantity Take-off"
70 When I look at the "Quantity Sets" panel
71 Then I see "Qto_WallBaseQuantities"
72 And I see "NetVolume"
73
74 Scenario: Perform quantity take-off - using Blender engine
75 Given an empty IFC project
76 And I add a cube
77 And the object "Cube" is selected
78 And I look at the "Class" panel
79 And I set the "Products" property to "IfcElement"
80 And I set the "Class" property to "IfcWall"
81 And I click "Assign IFC Class"
82 And I look at the "Quantity Take-off" panel
83 When I set the "qto_rule" property to "IFC4 Base Quantities - Blender"
84 And I see "Quantifying 1 Selected Objects"
85 And I click "Perform Quantity Take-off"
86 When I look at the "Quantity Sets" panel
87 Then I see "Qto_WallBaseQuantities"
88 And I see "NetVolume"
89
90 Scenario: Manual quantification
91 Given an empty IFC project
92 And I add a cube
93 And the object "Cube" is selected
94 And I look at the "Class" panel
95 And I set the "Products" property to "IfcElement"
96 And I set the "Class" property to "IfcWall"
97 And I click "Assign IFC Class"
98 And I look at the "Manual Quantification" panel
99 When I set the "qto_name" property to "Foo"
100 And I set the "prop_name" property to "Bar"
101 And I click "Calculate Single Quantity"
102 When I look at the "Quantity Sets" panel
103 Then I see "Foo"
104 And I see "Bar"
105
106 Scenario: Manual quantification - set an engine and function
107 Given an empty IFC project
108 And I add a cube
109 And the object "Cube" is selected
110 And I look at the "Class" panel
111 And I set the "Products" property to "IfcElement"
112 And I set the "Class" property to "IfcWall"
113 And I click "Assign IFC Class"
114 And I look at the "Manual Quantification" panel
115 And I set the "Calculator" property to "IfcOpenShell"
116 And I set the "Function" property to "Volume: Net Volume"
117 When I set the "qto_name" property to "Foo"
118 And I set the "prop_name" property to "Bar"
119 And I click "Calculate Single Quantity"
120 When I look at the "Quantity Sets" panel
121 Then I see "Foo"
122 And I see "Bar"