Debian Codegraph @

t/results/recursive

raw
1 From [email protected] Thu Jan 1 05:56:53 1998
2 Received: from aleve.media.mit.edu by hub.media.mit.edu; (5.65v3.2/1.1/06Jun95-8.2MPM)
3 id AA29720; Thu, 1 Jan 1998 05:56:53 -0500
4 Received: from kott.my.domain ([email protected] [198.110.144.127])
5 by aleve.media.mit.edu (8.8.7/ML970927) with ESMTP id FAA31795
6 for <[email protected]>; Thu, 1 Jan 1998 05:06:14 -0500 (EST)
7 Received: from kott.my.domain ([email protected] [192.168.0.1])
8 by kott.my.domain (8.8.8/8.8.5) with SMTP id FAA01072
9 for <[email protected]>; Thu, 1 Jan 1998 05:06:33 -0500 (EST)
10 Date: Thu, 1 Jan 1998 05:06:32 -0500 (EST)
11 From: David Kott <[email protected]>
12 Sender: [email protected]
13 To: [email protected]
14 Subject: Re: Digital outputs.
15 In-Reply-To: <[email protected]>
16 Message-Id: <[email protected]>
17 Mime-Version: 1.0
18 Content-Type: TEXT/PLAIN; charset=US-ASCII
19
20 On Wed, 31 Dec 1997, Tom Brusehaver wrote:
21
22 <snip>
23 >
24 > G> Wich are the options to have 3 digital outputs in the handyboard?
25 > G> No matter if i have to do little modifications to the Hardware. I
26 > G> already know how to conect the keypad if you can tell me how
27 > G> obtain 3 outputs.. :)
28 >
29 >
30 > The SPI port is sitting there. I think you can get at 3 outputs from
31 > those pins (SD/RD/CLK).
32 >
33 </snip>
34
35 yet ANOTHER idea, if you are suitably masochistic, is to use the SPI port
36 for a much more extensible I/O system. As you know, SPI uses 4 basic
37 control signals, MOSI, MISO, CLK and SS... Ok, what we used to do in
38 Embedded Controllers class is hook up a Serial In/Parallel Out
39 (hereforward referred to as a SIPO) shift register. You must have at
40 least ONE output available, so, this pretty much eliminates a L293 or, if
41 you are bold enough, obtain additional outputs using a '138 as outlined in
42 the HandyBoard FAQ. A SIPO you might use is the 8 bit 74164.
43
44 Hook the DATA IN on the SIPO to the MOSI pin on the SPI. Hook the
45 SPI's CLK output to the SIPO's clock pin. Use a transparent latch to
46 update and hold the data on the outputs of the SIPO and update it with the
47 one output pin, perhaps a 74373.
48
49 To update the new 8 bits of data appearing at your latch's output, you load
50 the SPI's data register with the byte value that you want to have across
51 your new outputs. This data will be shifted out during the next 8 E-clock
52 cycles. After the SPI's data register is empty indicating that the SIPO
53 has the output byte on it's parallel outputs, pulse the single control
54 output to update the latch's outputs.
55
56 With this arrangement, you could, in theory, have many, many SIPO shift
57 register/Latch pairs; the Serial Data In of the next stage connected to
58 the last Parallel Output on the previous adjacent stage.
59
60 One would just have to make sure that you coordinated the number of stages
61 with the number of bytes outshifted by the SPI data register (naturally).
62 The downside to this arrangement is the time it takes to update a digital
63 output. The entire train (8 bits, 16 bits, 24 bits... more?) Need to be
64 loaded and shifted out to change just ONE output. The upside is, the data
65 will shift at 2 Mhz, which makes for a (250 ns * [8+2] ) 2.5 ms update
66 time. Not suitable for time critical applications, (PWM, Communication)
67 but not bad for bulk outputs.
68
69 I don't think I have explained my little circuit here very well.. perhaps
70 an ASCII graphic?
71
72 Output originally going to an L293D
73 +---------------------------------------+
74 |Or added via a '138 from the |
75 |expansion buss. |
76 | +--+----+
77 +----+---------+ +---------+ | LE |
78 | | SPI CLK |'164 PO0|----| '373 |----
79 | +-----------+ CP PO1|----| |----
80 | 68HC11 | SPI MOSI | PO2|----| |----
81 | +-----------+ Data PO3|----| |---- New
82 | | | PO4|----| |---- Digital
83 +--------------+ | PO5|----| |---- Outputs
84 | PO6|----| |----
85 | PO7|----| |----
86 +---------+ +-------+
87
88
89 Where:
90 PO# is a "Parallel Output" on a SIPO
91 Data is the "Serial Data Input" on a SIPO
92 CP is the SIPO's clock
93
94
95 -d
96
97
98 Win95/NT - 32 bit extensions and a graphical shell for a 16 bit patch to
99 an 8 bit operating system originally coded for a 4 bit microprocessor,
100 written by a 2 bit company that can't stand 1 bit of competition. -UGU