| 1 |
.. 6.90 |
| 2 |
|
| 3 |
B-H Curve |
| 4 |
========= |
| 5 |
|
| 6 |
Schematic |
| 7 |
--------- |
| 8 |
|
| 9 |
- To Record Magnetic Hysterisis using a solenoid connected to PV1, and a MPU925x magnetometer connected to the I2C port. |
| 10 |
|
| 11 |
Instructions |
| 12 |
------------ |
| 13 |
|
| 14 |
- Connect the coil between PV1 and ground |
| 15 |
- Connect the Magnetometer(MPU925x) to the I2C port |
| 16 |
- Place the solenoid on top of the sensor such that the magnetic axis is perpendicular to the sensor |
| 17 |
- Acquire data : This changes the PV1 voltage from -3 to 3 volts in 100 steps, and returns from 3V to -3V . This results in a proportional magnetic field generated by the solenoid which is also measured by the sensor and plotted |
| 18 |
- Add a ferromagnetic material such as an alligator clip, and repeat the acquisition. Observe the hysteris for various different materials. |