Debian Codegraph @

config/eurotronic/eur_temphumin.xml

raw
1 <?xml version="1.0" encoding="utf-8"?>
2 <!--
3 Eurotronic Z-Wave Plus temperature and humitity sensor
4 Product website: https://eurotronic.org/produkte/sensoren/temperatur-feuchte-sensor/
5 -->
6 <Product Revision="2" xmlns="https://github.com/OpenZWave/open-zwave">
7 <MetaData>
8 <MetaDataItem name="OzwInfoPage">http://www.openzwave.com/device-database/0148:0001:0004</MetaDataItem>
9 <MetaDataItem name="Name">Temperature and Humidity Sensor</MetaDataItem>
10 <MetaDataItem name="ProductPic">images/eurotronic/eur_temphumid.png</MetaDataItem>
11 <MetaDataItem name="InclusionDescription">Start Inclusion mode of your primary Z-Wave Controller.
12 Press the network button three times within 1 second.</MetaDataItem>
13 <MetaDataItem name="ResetDescription">Please use this procedure only when the network primary controller is missing or otherwise inoperable.
14
15 Press and hold the network button for at least 10 seconds. The temperature humidity sensor will indicate
16 the reset blinking pattern once the reset is completed.
17 </MetaDataItem>
18 <MetaDataItem id="0001" name="FrequencyName" type="0004">CEPT (Europe)</MetaDataItem>
19 <MetaDataItem id="0001" name="ZWProductPage" type="0004">https://eurotronic.org/produkte/sensoren/temperatur-feuchte-sensor/</MetaDataItem>
20 <MetaDataItem name="ProductManual">https://eurotronic.org/</MetaDataItem>
21 <MetaDataItem name="Description">
22 <!--
23 TODO: English manual not yet available on website of eurotronics
24 -->
25 This Z-Wave sensor provides comprehensive information on indoor
26 temperature and humidity.
27 • Returns the following values:
28 - Temperature (°C)
29 - Humidity (%)
30 - Dew point (°C)
31 • Supports Z-Wave Plus S2 security (encryption)
32 </MetaDataItem>
33
34 <ChangeLog>
35 <Entry author="[email protected]" date="13 Mar 2020" revision="2">Initial Metadata Import </Entry>
36 </ChangeLog>
37 </MetaData>
38
39 <!-- Configuration Parameters -->
40 <CommandClass id="112">
41 <Instance index="1"/>
42 <Value type="byte" genre="config" instance="1" index="1" label="Temperature on Change Reporting" min="0" max="50" value="5" size="1">
43 <Help>
44 0: Don't report temperature changes
45 1-50: Report temperature changes from 0,1°C - 5,0°C
46 Default: 5
47 </Help>
48 </Value>
49
50 <Value type="byte" genre="config" instance="1" index="2" label="Humidity on Change Reporting" min="0" max="10" value="5" size="1">
51 <Help>
52 0: Don't report humidity changes
53 1-10: report humidity changes in 1% steps
54 Default: 5
55 </Help>
56 </Value>
57 <Value type="list" genre="config" instance="1" index="3" label="Temperature Scale" min="0" max="1" value="0" size="1">
58 <Help>
59 0: Temperature in Degrees Celcius
60 1: Temperature in Degrees Fahrenheit
61 Default: 0
62 </Help>
63 <Item label="Celsius" value="0" />
64 <Item label="Fahrenheit" value="1" />
65 </Value>
66 <Value type="byte" genre="config" instance="1" index="4" label="Temperature Resolution" min="0" max="2" value="1" size="1">
67 <Help>
68 0: no decimal places
69 1: one decimal place
70 2: two decimal places
71 Default: 1
72 </Help>
73 </Value>
74 <Value type="byte" genre="config" instance="1" index="5" label="Humidity Resolution" min="0" max="2" value="0" size="1">
75 <Help>
76 0: no decimal places
77 1: one decimal place
78 2: two decimal places
79 Default: 0
80 </Help>
81 </Value>
82 </CommandClass>
83
84
85 <!-- Association Groups -->
86 <CommandClass id="133">
87 <Associations num_groups="2">
88 <Group index="1" max_associations="1" label="Lifeline" />
89 <Group index="2" max_associations="5" label="Temperature" />
90 </Associations>
91 </CommandClass>
92 </Product>