1 <?xml version="1.0" encoding="utf-8"?>
2 <!--
3 Eurotronic Z-Wave Plus air quality sensor
4 Product website: https://eurotronic.org/produkte/sensoren/luftguetesensor/
5 -->
6 <Product Revision="2" xmlns="https://github.com/OpenZWave/open-zwave">
7 <MetaData>
8 <MetaDataItem name="OzwInfoPage">http://www.openzwave.com/device-database/0148:0001:0005</MetaDataItem>
9 <MetaDataItem name="ProductPic">images/eurotronic/eur_airquality.png</MetaDataItem>
10 <MetaDataItem name="InclusionDescription">Start Inclusion mode of your primary Z-Wave Controller.
11 Press the network button three times within 1 second.</MetaDataItem>
12 <MetaDataItem name="ProductManual">https://eurotronic.org/wp-content/uploads/2020/02/LGS-Z-Wave-Plus_BDA_web_EN-1.pdf</MetaDataItem>
13 <MetaDataItem name="ExclusionDescription">Start Exclusion mode of your primary Z-Wave Controller.
14 Press the network button three times within 1 second.</MetaDataItem>
15 <MetaDataItem name="Name">Air Quality Sensor</MetaDataItem>
16 <MetaDataItem name="ResetDescription">Please use this procedure only when the network primary controller is missing or otherwise inoperable.
17
18 Press and hold the network button for at least 10 seconds. The Air Quality Sensor Z-Wave Plus will indicate
19 the reset blinking pattern once the reset is completed.
20 </MetaDataItem>
21 <MetaDataItem name="Description">This Z-Wave sensor provides comprehensive information on indoor
22 air quality.
23 • Multicolor LED for signalling ventilation recommendations
24 • Returns the following values:
25 - VOC value (volatile organic compounds) in ppm
26 - CO2 value (as CO2 equivalent) in ppm
27 - Temperature (°C)
28 - Humidity (%)
29 - Dew point (°C)
30 • Supports Z-Wave Plus S2 security (encryption)
31 • Z-Wave repeater function
32 • Operation with plug-in power supply unit
33 </MetaDataItem>
34 <ChangeLog>
35 <Entry author="[email protected]" date="13 Mar 2020" revision="2">Initial Metadata Import from https://eurotronic.org/wp-content/uploads/2020/02/LGS-Z-Wave-Plus_BDA_web_EN-1.pdf/</Entry>
36 </ChangeLog>
37 <MetaDataItem id="0001" name="FrequencyName" type="0005">CEPT (Europe)</MetaDataItem>
38 <MetaDataItem id="0001" name="ZWProductPage" type="0005">https://eurotronic.org/produkte/sensoren/luftguetesensor/</MetaDataItem>
39 </MetaData>
40
41 <!-- Configuration Parameters -->
42 <CommandClass id="112">
43 <Instance index="1"/>
44 <Value type="byte" genre="config" instance="1" index="1" label="Temperature on Change Reporting" min="0" max="50" value="5" size="1">
45 <Help>
46 0: No on change reporting (only time-based reports)
47 1-50: report if temperature changed by delta = 0,1°C - 5,0°C
48 Default: 5
49 </Help>
50 </Value>
51
52 <Value type="byte" genre="config" instance="1" index="2" label="Humidity on Change Reporting" min="0" max="10" value="5" size="1">
53 <Help>
54 0: No on change reporting (only time-based reports)
55 1-10: report if humidity changed by delta = 1% ...10%
56 Default: 5
57 </Help>
58 </Value>
59 <Value type="list" genre="config" instance="1" index="3" label="Temperature Scale" min="0" max="1" value="0" size="1">
60 <Help>
61 Temperature in Degrees Celcius
62 Temperature in Degrees Fahrenheit
63 Default: Temperature in Degrees Celcius
64 </Help>
65 <Item label="Celsius" value="0" />
66 <Item label="Fahrenheit" value="1" />
67 </Value>
68 <Value type="list" genre="config" instance="1" index="4" label="Temperature Resolution" min="0" max="2" value="1" size="1">
69 <Help>
70 No resolution (example 22°C)
71 1/10 resolution (example 22.3°C)
72 1/100 resolution (example 22.35°C)
73 Default: No resolution (example 22°C)
74 </Help>
75 <Item label="No resolution (example 22°C)" value="0" />
76 <Item label="1/10 resolution (example 22.3°C)" value="1" />
77 <Item label="1/100 resolution (example 22.35°C)" value="2" />
78 </Value>
79 <Value type="list" genre="config" instance="1" index="5" label="Humidity Resolution" min="0" max="2" value="0" size="1">
80 <Help>
81 No resolution (example 33%)
82 1/10 resolution (example 33.4%)
83 1/100 resolution (example 33.45%
84 Default: No resolution (example 33%
85 </Help>
86 <Item label="No resolution (example 33%)" value="0" />
87 <Item label="1/10 resolution (example 33.4%)" value="1" />
88 <Item label="1/100 resolution (example 33.45%)" value="2" />
89 </Value>
90 <Value type="byte" genre="config" instance="1" index="6" label="VOC on Change Reporting" min="0" max="10" value="5" size="1">
91 <Help>
92 0: No on change reporting (only time-based reports)
93 1-10: report if VOC reading changed by 100ppb - 1000ppb
94 Default: 5
95 </Help>
96 </Value>
97 <Value type="byte" genre="config" instance="1" index="7" label="CO2eq on Change Reporting" min="0" max="10" value="5" size="1">
98 <Help>
99 0: No on change reporting (only time-based reports)
100 1-10: report if CO2eq reading changed by 100ppm - 1000ppm
101 Default: 5
102 </Help>
103 </Value>
104 <Value type="list" genre="config" instance="1" index="8" label="Air quality indication via LED" min="0" max="1" value="1" size="1">
105 <Help>
106 0: No air quality indication via LEDs
107 1: Indicate measuered air quality via LEDs
108 Default: 1
109 </Help>
110 <Item label="No air quality indication via LEDs" value="0" />
111 <Item label="Indicate measuered air quality via LEDs" value="1" />
112 </Value>
113 </CommandClass>
114 <!-- Association Groups -->
115 <CommandClass id="133">
116 <Associations num_groups="2">
117 <Group index="1" max_associations="1" label="Lifeline" />
118 <Group index="2" max_associations="5" label="Temperature" />