| 1 |
|
| 2 |
// Copyright (c) 2003-2019 Xsens Technologies B.V. or subsidiaries worldwide. |
| 3 |
// All rights reserved. |
| 4 |
// |
| 5 |
// Redistribution and use in source and binary forms, with or without modification, |
| 6 |
// are permitted provided that the following conditions are met: |
| 7 |
// |
| 8 |
// 1. Redistributions of source code must retain the above copyright notice, |
| 9 |
// this list of conditions, and the following disclaimer. |
| 10 |
// |
| 11 |
// 2. Redistributions in binary form must reproduce the above copyright notice, |
| 12 |
// this list of conditions, and the following disclaimer in the documentation |
| 13 |
// and/or other materials provided with the distribution. |
| 14 |
// |
| 15 |
// 3. Neither the names of the copyright holders nor the names of their contributors |
| 16 |
// may be used to endorse or promote products derived from this software without |
| 17 |
// specific prior written permission. |
| 18 |
// |
| 19 |
// THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY |
| 20 |
// EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF |
| 21 |
// MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL |
| 22 |
// THE COPYRIGHT HOLDERS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, |
| 23 |
// SPECIAL, EXEMPLARY OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT |
| 24 |
// OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) |
| 25 |
// HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY OR |
| 26 |
// TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS |
| 27 |
// SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.THE LAWS OF THE NETHERLANDS |
| 28 |
// SHALL BE EXCLUSIVELY APPLICABLE AND ANY DISPUTES SHALL BE FINALLY SETTLED UNDER THE RULES |
| 29 |
// OF ARBITRATION OF THE INTERNATIONAL CHAMBER OF COMMERCE IN THE HAGUE BY ONE OR MORE |
| 30 |
// ARBITRATORS APPOINTED IN ACCORDANCE WITH SAID RULES. |
| 31 |
// |
| 32 |
|
| 33 |
#ifndef XSRESULTVALUE_H |
| 34 |
#define XSRESULTVALUE_H |
| 35 |
|
| 36 |
#include "xstypesconfig.h" |
| 37 |
|
| 38 |
#ifdef __cplusplus |
| 39 |
extern "C" { |
| 40 |
#endif |
| 41 |
|
| 42 |
////////////////////////////////////////////////////////////////////////////////////////// |
| 43 |
/*! \addtogroup enums Global enumerations |
| 44 |
@{ |
| 45 |
*/ |
| 46 |
/*! \brief Xsens result values |
| 47 |
\details These values are used to signal success or specific failures of functions |
| 48 |
\sa XsResultValue_toString |
| 49 |
*/ |
| 50 |
enum XsResultValue { |
| 51 |
// general OK |
| 52 |
XRV_OK = 0 //!< 0: Operation was performed successfully |
| 53 |
|
| 54 |
// communication protocol |
| 55 |
,XRV_NOBUS = 1 //!< 1: No bus communication possible |
| 56 |
,XRV_BUSNOTREADY = 2 //!< 2: InitBus and/or SetBID are not issued |
| 57 |
,XRV_INVALIDPERIOD = 3 //!< 3: Period sent is invalid |
| 58 |
,XRV_INVALIDMSG = 4 //!< 4: The message is invalid or not implemented |
| 59 |
,XRV_INITBUSFAIL1 = 16 //!< 16: A slave did not respond to WaitForSetBID |
| 60 |
,XRV_INITBUSFAIL2 = 17 //!< 17: An incorrect answer received after WaitForSetBID |
| 61 |
,XRV_INITBUSFAIL3 = 18 //!< 18: After four bus-scans still undetected Motion Trackers |
| 62 |
,XRV_SETBIDFAIL1 = 20 //!< 20: No reply to SetBID message during SetBID procedure |
| 63 |
,XRV_SETBIDFAIL2 = 21 //!< 21: Other than SetBIDAck received |
| 64 |
,XRV_MEASUREMENTFAIL1 = 24 //!< 24: Timer overflow - period too short to collect all data from Motion Trackers |
| 65 |
,XRV_MEASUREMENTFAIL2 = 25 //!< 25: Motion Tracker responds with other than SlaveData message |
| 66 |
,XRV_MEASUREMENTFAIL3 = 26 //!< 26: Total bytes of data of Motion Trackers including sample counter exceeds 255 bytes |
| 67 |
,XRV_MEASUREMENTFAIL4 = 27 //!< 27: Timer overflows during measurement |
| 68 |
,XRV_MEASUREMENTFAIL5 = 28 //!< 28: Timer overflows during measurement |
| 69 |
,XRV_MEASUREMENTFAIL6 = 29 //!< 29: No correct response from Motion Tracker during measurement |
| 70 |
,XRV_TIMEROVERFLOW = 30 //!< 30: Timer overflows during measurement |
| 71 |
,XRV_BAUDRATEINVALID = 32 //!< 32: Baud rate does not comply with valid range |
| 72 |
,XRV_INVALIDPARAM = 33 //!< 33: An invalid parameter is supplied |
| 73 |
,XRV_MEASUREMENTFAIL7 = 35 //!< 35: TX PC Buffer is full |
| 74 |
,XRV_MEASUREMENTFAIL8 = 36 //!< 36: TX PC Buffer overflow, cannot fit full message |
| 75 |
,XRV_WIRELESSFAIL = 37 //!< 37: Wireless subsystem failed |
| 76 |
,XRV_DEVICEERROR = 40 //!< 40: The device generated an error, try updating the firmware |
| 77 |
,XRV_DATAOVERFLOW = 41 //!< 41: The device generates more data than the bus communication can handle (baud rate may be too low) |
| 78 |
,XRV_BUFFEROVERFLOW = 42 //!< 42: The sample buffer of the device was full during a communication outage |
| 79 |
,XRV_EXTTRIGGERERROR = 43 //!< 43: The external trigger is not behaving as configured |
| 80 |
,XRV_SAMPLESTREAMERROR = 44 //!< 44: The sample stream detected an error in the ordering of sample data |
| 81 |
,XRV_POWER_DIP = 45 //!< 45: A dip in the power supply was detected and recovered from |
| 82 |
,XRV_POWER_OVERCURRENT = 46 //!< 46: A current limiter has been activated, shutting down the device |
| 83 |
,XRV_OVERHEATING = 47 //!< 47: Device temperature is not within operational limits |
| 84 |
,XRV_BATTERYLOW = 48 //!< 48: Battery level reached lower limit |
| 85 |
,XRV_INVALIDFILTERPROFILE = 49 //!< 49: Specified filter profile ID is not available on the device or the user is trying to duplicate an existing filter profile type |
| 86 |
,XRV_INVALIDSTOREDSETTINGS = 50 //!< 50: The settings stored in the device's non volatile memory are invalid |
| 87 |
,XRV_ACCESSDENIED = 51 //!< 51: Request for control of the device was denied |
| 88 |
,XRV_FILEERROR = 52 //!< 52: Failure reading, writing, opening or closing a file |
| 89 |
,XRV_OUTPUTCONFIGERROR = 53 //!< 53: Erroneous output configuration, device can not go to measurement |
| 90 |
|
| 91 |
// CMT / XDA / XME / etc |
| 92 |
,XRV_ERROR = 256 //!< 256: A generic error occurred |
| 93 |
,XRV_NOTIMPLEMENTED = 257 //!< 257: Operation not implemented in this version (yet) |
| 94 |
,XRV_TIMEOUT = 258 //!< 258: A timeout occurred |
| 95 |
,XRV_TIMEOUTNODATA = 259 //!< 259: Operation aborted because of no data read |
| 96 |
,XRV_CHECKSUMFAULT = 260 //!< 260: Checksum fault occurred |
| 97 |
,XRV_OUTOFMEMORY = 261 //!< 261: No internal memory available |
| 98 |
,XRV_NOTFOUND = 262 //!< 262: The requested item was not found |
| 99 |
,XRV_UNEXPECTEDMSG = 263 //!< 263: Unexpected message received (e.g. no acknowledge message received) |
| 100 |
,XRV_INVALIDID = 264 //!< 264: Invalid id supplied |
| 101 |
,XRV_INVALIDOPERATION = 265 //!< 265: Operation is invalid at this point |
| 102 |
,XRV_INSUFFICIENTSPACE = 266 //!< 266: Insufficient buffer space available |
| 103 |
,XRV_INPUTCANNOTBEOPENED = 267 //!< 267: The specified i/o device can not be opened |
| 104 |
,XRV_OUTPUTCANNOTBEOPENED = 268 //!< 268: The specified i/o device can not be opened |
| 105 |
,XRV_ALREADYOPEN = 269 //!< 269: An I/O device is already opened with this object |
| 106 |
,XRV_ENDOFFILE = 270 //!< 270: End of file is reached |
| 107 |
,XRV_COULDNOTREADSETTINGS = 271 //!< 271: A required settings file could not be opened or is missing some data |
| 108 |
,XRV_NODATA = 272 //!< 272: No data is available |
| 109 |
,XRV_READONLY = 273 //!< 273: Tried to change a read-only value |
| 110 |
,XRV_NULLPTR = 274 //!< 274: Tried to supply a NULL value where it is not allowed |
| 111 |
,XRV_INSUFFICIENTDATA = 275 //!< 275: Insufficient data was supplied to a function |
| 112 |
,XRV_BUSY = 276 //!< 276: Busy processing, try again later |
| 113 |
,XRV_INVALIDINSTANCE = 277 //!< 277: Invalid instance called, because of an invalid or missing license |
| 114 |
,XRV_DATACORRUPT = 278 //!< 278: A trusted data stream proves to contain corrupted data |
| 115 |
|
| 116 |
,XRV_READINITFAILED = 279 //!< 279: Failure during read of settings |
| 117 |
,XRV_NOXMFOUND = 280 //!< 280: Could not find any MVN-compatible hardware |
| 118 |
,XRV_DEVICECOUNTZERO = 282 //!< 282: No xsens devices found |
| 119 |
,XRV_MTLOCATIONINVALID = 283 //!< 283: One or more sensors are not where they were expected |
| 120 |
,XRV_INSUFFICIENTMTS = 284 //!< 284: Not enough sensors were found |
| 121 |
,XRV_INITFUSIONFAILED = 285 //!< 285: Failure during initialization of Fusion Engine |
| 122 |
,XRV_OTHER = 286 //!< 286: Something else was received than was requested |
| 123 |
|
| 124 |
,XRV_NOFILEOPEN = 287 //!< 287: No file opened for reading/writing |
| 125 |
,XRV_NOPORTOPEN = 288 //!< 288: No serial port opened for reading/writing |
| 126 |
,XRV_NOFILEORPORTOPEN = 289 //!< 289: No file or serial port opened for reading/writing |
| 127 |
,XRV_PORTNOTFOUND = 290 //!< 290: A required port could not be found |
| 128 |
,XRV_INITPORTFAILED = 291 //!< 291: The low-level port handler failed to initialize |
| 129 |
,XRV_CALIBRATIONFAILED = 292 //!< 292: A calibration routine failed |
| 130 |
|
| 131 |
,XRV_CONFIGCHECKFAIL = 293 //!< 293: A configuration-time check of the device failed |
| 132 |
,XRV_ALREADYDONE = 294 //!< 294: The operation is once only and has already been performed |
| 133 |
|
| 134 |
,XRV_SYNC_SINGLE_SLAVE = 295 //!< 295: The single connected device is configured as a slave |
| 135 |
,XRV_SYNC_SECOND_MASTER = 296 //!< 296: More than one master was detected |
| 136 |
,XRV_SYNC_NO_SYNC = 297 //!< 297: A device was detected that was neither master nor slave |
| 137 |
,XRV_SYNC_NO_MASTER = 298 //!< 298: No master detected |
| 138 |
,XRV_SYNC_DATA_MISSING = 299 //!< 299: A device is not sending enough data |
| 139 |
|
| 140 |
,XRV_VERSION_TOO_LOW = 300 //!< 300: The version of the object is too low for the requested operation |
| 141 |
,XRV_VERSION_PROBLEM = 301 //!< 301: The object has an unrecognised version, so it's not safe to perform the operation |
| 142 |
|
| 143 |
,XRV_ABORTED = 302 //!< 302: The process was aborted by an external event, usually a user action or process termination |
| 144 |
,XRV_UNSUPPORTED = 303 //!< 303: The requested functionality is not supported by the device |
| 145 |
|
| 146 |
,XRV_PACKETCOUNTERMISSED = 304 //!< 304: A packet counter value was missed |
| 147 |
|
| 148 |
,XRV_MEASUREMENTFAILED = 305 //!< 305: An error occurred while trying to put the device in measurement mode |
| 149 |
,XRV_STARTRECORDINGFAILED = 306 //!< 306: A device could not start recording |
| 150 |
,XRV_STOPRECORDINGFAILED = 307 //!< 307: A device could not stop recording |
| 151 |
|
| 152 |
,XRV_RADIO_CHANNEL_IN_USE = 311 //!< 311: Radio channel is in use by another system |
| 153 |
,XRV_UNEXPECTED_DISCONNECT = 312 //!< 312: Motion tracker disconnected unexpectedly |
| 154 |
,XRV_TOO_MANY_CONNECTED_TRACKERS = 313 //!< 313: Too many motion trackers connected |
| 155 |
,XRV_GOTOCONFIGFAILED = 314 //!< 314: A device could not be put in config mode |
| 156 |
,XRV_OUTOFRANGE = 315 //!< 315: Device has gone out of range |
| 157 |
,XRV_BACKINRANGE = 316 //!< 316: Device is back in range, resuming normal operation |
| 158 |
,XRV_EXPECTED_DISCONNECT = 317 //!< 317: The device was disconnected |
| 159 |
|
| 160 |
,XRV_RESTORE_COMMUNICATION_FAILED = 318 //!< 318: Restore communication failed |
| 161 |
,XRV_RESTORE_COMMUNICATION_STOPPED = 319 //!< 319: Restore communication was stopped |
| 162 |
|
| 163 |
,XRV_EXPECTED_CONNECT = 320 //!< 320: The device was connected |
| 164 |
|
| 165 |
// notifications |
| 166 |
,XRV_SHUTTINGDOWN = 400 //!< 400: The device is shutting down |
| 167 |
,XRV_GNSSCONFIGURATIONERROR = 401 //!< 401: A configuration item was refused by the GNSS module |
| 168 |
,XRV_GNSSCOMMTIMEOUT = 402 //!< 402: The communication with the GNSS module timed out |
| 169 |
,XRV_GNSSERROR = 403 //!< 403: Communication between the device and the GNSS module failed |
| 170 |
,XRV_DEVICE_NOT_CALIBRATED = 404 //!< 404: The EMTS of the device does not contain calibration data |
| 171 |
|
| 172 |
}; |
| 173 |
/*! @} */ |
| 174 |
typedef enum XsResultValue XsResultValue; |
| 175 |
|
| 176 |
//! These enum values can be used to specify a device error (XRV_DEVICEERROR 0x28), i.e. a xbus message like [FA FF 42 05 28 XXXXXXXX CS] |
| 177 |
enum XsDeviceErrorType |
| 178 |
{ |
| 179 |
XERR_Unknown = 0 |
| 180 |
, XERR_ImcuTimeout = 1 |
| 181 |
, XERR_ImcuSettingsInvalid = 2 |
| 182 |
, XERR_ImcuSettingsFailure = 3 |
| 183 |
, XERR_ImcuEmtsWriteFailure = 4 |
| 184 |
, XERR_ImcuEmtsReadFailure = 5 |
| 185 |
, XERR_DspCrashed = 6 |
| 186 |
, XERR_DspBootingTimeout = 7 |
| 187 |
, XERR_DspSettingsInvalid = 8 |
| 188 |
}; |
| 189 |
typedef enum XsDeviceErrorType XsDeviceErrorType; |
| 190 |
|
| 191 |
////////////////////////////////////////////////////////////////////////////////////////// |
| 192 |
|
| 193 |
/* \brief Retrieve a string corresponding to the given result code. |
| 194 |
|
| 195 |
This function uses the XsResultText list to return a string with the relevant result |
| 196 |
code in a textual format. If the supplied result code is invalid the |
| 197 |
"!!Undefined Result Value!!" string is returned. |
| 198 |
*/ |
| 199 |
XSTYPES_DLL_API const char* XsResultValue_toString(XsResultValue result); |
| 200 |
|
| 201 |
#ifdef __cplusplus |
| 202 |
} // extern "C" |
| 203 |
#endif |
| 204 |
|
| 205 |
#endif |