Debian Codegraph @

3rdparty/xspublic/xstypes/xsresultvalue.c

raw
1
2 // Copyright (c) 2003-2019 Xsens Technologies B.V. or subsidiaries worldwide.
3 // All rights reserved.
4 //
5 // Redistribution and use in source and binary forms, with or without modification,
6 // are permitted provided that the following conditions are met:
7 //
8 // 1. Redistributions of source code must retain the above copyright notice,
9 // this list of conditions, and the following disclaimer.
10 //
11 // 2. Redistributions in binary form must reproduce the above copyright notice,
12 // this list of conditions, and the following disclaimer in the documentation
13 // and/or other materials provided with the distribution.
14 //
15 // 3. Neither the names of the copyright holders nor the names of their contributors
16 // may be used to endorse or promote products derived from this software without
17 // specific prior written permission.
18 //
19 // THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY
20 // EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
21 // MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL
22 // THE COPYRIGHT HOLDERS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
23 // SPECIAL, EXEMPLARY OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT
24 // OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
25 // HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY OR
26 // TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS
27 // SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.THE LAWS OF THE NETHERLANDS
28 // SHALL BE EXCLUSIVELY APPLICABLE AND ANY DISPUTES SHALL BE FINALLY SETTLED UNDER THE RULES
29 // OF ARBITRATION OF THE INTERNATIONAL CHAMBER OF COMMERCE IN THE HAGUE BY ONE OR MORE
30 // ARBITRATORS APPOINTED IN ACCORDANCE WITH SAID RULES.
31 //
32
33 #include "xsresultvalue.h"
34
35 /*! \addtogroup cinterface C Interface
36 @{
37 */
38
39 //////////////////////////////////////////////////////////////////////////////////////////
40 /*! \brief Retrieve a character string corresponding to the given result code.
41 \param result The result code to convert
42 \return A static string describing the result code
43 \note In the Python interface this function is called XsResultValueToString
44 \note In C/C++ do NOT delete the returned char* as it points to static memory.
45 */
46 const char* XsResultValue_toString(XsResultValue result)
47 {
48 switch(result)
49 {
50 case XRV_OK: return "No error";
51
52 // Communication protocol
53 case XRV_NOBUS: return "Bus has no power";
54 case XRV_BUSNOTREADY: return "Bus not ready for measurement";
55 case XRV_INVALIDPERIOD: return "Period is invalid";
56 case XRV_INVALIDMSG: return "Message is invalid";
57 case XRV_INITBUSFAIL1: return "A slave did not respond to WaitForSetBID";
58 case XRV_INITBUSFAIL2: return "An incorrect answer received after WaitForSetBID";
59 case XRV_INITBUSFAIL3: return "After four bus-scans still undetected Motion Trackers";
60 case XRV_SETBIDFAIL1: return "No reply to SetBID message during SetBID procedure";
61 case XRV_SETBIDFAIL2: return "Other than SetBIDAck received";
62 case XRV_MEASUREMENTFAIL1: return "Timer overflow - period too short to collect all data from Motion Trackers";
63 case XRV_MEASUREMENTFAIL2: return "Motion Tracker responds with other than SlaveData message";
64 case XRV_MEASUREMENTFAIL3: return "Total bytes of data of Motion Trackers incl sample counter exceeds 255 bytes";
65 case XRV_MEASUREMENTFAIL4: return "Timer overflow during measurement - MT does not respond within measurement period. Increase period (lower update rate)";
66 case XRV_MEASUREMENTFAIL5: return "Timer overflow during measurement - MT response was not received within measurement period. Increase period (lower update rate) or use fewer Motion Trackers";
67 case XRV_MEASUREMENTFAIL6: return "No correct response from Motion Tracker during measurement";
68 case XRV_TIMEROVERFLOW: return "Timer overflow during measurement";
69 case XRV_BAUDRATEINVALID: return "Baudrate does not comply with valid range";
70 case XRV_INVALIDPARAM: return "Invalid parameter supplied";
71 case XRV_MEASUREMENTFAIL7: return "TX PC Buffer is full";
72 case XRV_MEASUREMENTFAIL8: return "TX PC Buffer overflow, cannot fit full message";
73 case XRV_WIRELESSFAIL: return "Wireless communication system failed";
74 case XRV_DEVICEERROR: return "The device generated an error, try updating the firmware";
75 case XRV_DATAOVERFLOW: return "Data overflow";
76 case XRV_BUFFEROVERFLOW: return "Sample buffer overflow during communication outage";
77 case XRV_EXTTRIGGERERROR: return "The external trigger is not behaving as configured";
78 case XRV_SAMPLESTREAMERROR: return "Sample stream detected an error in ordering input data";
79 case XRV_POWER_DIP: return "A power dip has been detected and recovered from";
80 case XRV_POWER_OVERCURRENT: return "A current limiter has been activated";
81 case XRV_OVERHEATING: return "Device temperature exceeded operational limits";
82 case XRV_BATTERYLOW: return "Battery level reached lower limit";
83 case XRV_INVALIDFILTERPROFILE: return "Specified filter profile ID is not available on the device or the user is trying to duplicate an existing filter profile type";
84 case XRV_INVALIDSTOREDSETTINGS: return "The settings stored in the device's non volatile memory are invalid";
85 case XRV_ACCESSDENIED: return "Request for control of the device was denied";
86 case XRV_FILEERROR: return "Failure reading, writing, opening or closing a file";
87 case XRV_OUTPUTCONFIGERROR: return "Erroneous output configuration, device can not go to measurement";
88
89 // XDA / XME / etc
90 case XRV_ERROR: return "Generic error";
91 case XRV_NOTIMPLEMENTED: return "Operation not implemented";
92 case XRV_TIMEOUT: return "Timeout occurred, some data received";
93 case XRV_TIMEOUTNODATA: return "Timeout occurred, no data was received";
94 case XRV_CHECKSUMFAULT: return "Checksum fault";
95 case XRV_OUTOFMEMORY: return "Out of memory";
96 case XRV_NOTFOUND: return "Requested item was not found";
97 case XRV_UNEXPECTEDMSG: return "Unexpected message received";
98 case XRV_INVALIDID: return "Invalid id supplied";
99 case XRV_INVALIDOPERATION: return "Invalid operation";
100 case XRV_INSUFFICIENTSPACE: return "Insufficient buffer space available";
101 case XRV_INPUTCANNOTBEOPENED: return "Could not open input device";
102 case XRV_OUTPUTCANNOTBEOPENED: return "Could not open output device";
103 case XRV_ALREADYOPEN: return "A device is already open";
104 case XRV_ENDOFFILE: return "End of file reached";
105 case XRV_COULDNOTREADSETTINGS: return "A required settings file could not be opened or is missing some data";
106 case XRV_NODATA: return "No data available";
107 case XRV_READONLY: return "Tried to change a read-only value";
108 case XRV_NULLPTR: return "Invalid NULL pointer supplied";
109 case XRV_INSUFFICIENTDATA: return "Insufficient data supplied";
110 case XRV_BUSY: return "Busy processing, try again later";
111 case XRV_INVALIDINSTANCE: return "Invalid instance called, because of an invalid or missing license";
112 case XRV_DATACORRUPT: return "Data-source corrupt";
113
114 case XRV_READINITFAILED: return "Failure during reading of settings. File may be old or corrupt.";
115 case XRV_NOXMFOUND: return "Could not find any MVN-compatible hardware, check connections and LEDs";
116 case XRV_DEVICECOUNTZERO: return "No xsens devices found, check connections";
117 case XRV_MTLOCATIONINVALID: return "One or more sensors are not where they were expected, check locations";
118 case XRV_INSUFFICIENTMTS: return "Not enough sensors were found, check connections";
119 case XRV_INITFUSIONFAILED: return "Failure during initialization of Fusion Engine. Source file may be old or corrupt.";
120 case XRV_OTHER: return "Something else was received than was requested";
121
122 case XRV_NOFILEOPEN: return "No file open";
123 case XRV_NOPORTOPEN: return "No serial port open";
124 case XRV_NOFILEORPORTOPEN: return "No file or serial port open";
125 case XRV_PORTNOTFOUND: return "A required port could not be found";
126 case XRV_INITPORTFAILED: return "The low-level port handler failed to initialize";
127 case XRV_CALIBRATIONFAILED: return "A calibration routine failed";
128
129 case XRV_CONFIGCHECKFAIL: return "Failure during device configuration";
130 case XRV_ALREADYDONE: return "This once only operation has already been performed";
131
132 case XRV_SYNC_SINGLE_SLAVE: return "The single connected device is configured as a slave";
133 case XRV_SYNC_SECOND_MASTER: return "More than one master was detected";
134 case XRV_SYNC_NO_SYNC: return "A device was detected that was neither master nor slave";
135 case XRV_SYNC_NO_MASTER: return "No master detected";
136 case XRV_SYNC_DATA_MISSING: return "A device is not sending enough data, check synchronization cables";
137
138 case XRV_VERSION_TOO_LOW: return "The version of the object is too low for the requested operation";
139 case XRV_VERSION_PROBLEM: return "The object has an unrecognized version, so it's not safe to perform the operation";
140
141 case XRV_ABORTED: return "The process was aborted by an external event";
142 case XRV_UNSUPPORTED: return "The requested functionality is not supported by the device";
143
144 case XRV_PACKETCOUNTERMISSED: return "A packet counter value was missed";
145
146 case XRV_MEASUREMENTFAILED: return "Failed to start measurement";
147 case XRV_STARTRECORDINGFAILED: return "A device could not start recording";
148 case XRV_STOPRECORDINGFAILED: return "A device could not stop recording";
149
150 case XRV_RADIO_CHANNEL_IN_USE: return "Detected another system using the selected radio channel";
151 case XRV_UNEXPECTED_DISCONNECT: return "Motion tracker disconnected unexpectedly";
152 case XRV_TOO_MANY_CONNECTED_TRACKERS: return "Too many motion trackers connected";
153 case XRV_GOTOCONFIGFAILED: return "Failed to go to config mode";
154 case XRV_OUTOFRANGE: return "Device has gone out of range";
155 case XRV_BACKINRANGE: return "Device is back in range, resuming normal operation";
156 case XRV_EXPECTED_DISCONNECT: return "The device was disconnected";
157
158 case XRV_RESTORE_COMMUNICATION_FAILED: return "Restore communication failed";
159 case XRV_RESTORE_COMMUNICATION_STOPPED: return "Restore communication was stopped";
160
161 case XRV_EXPECTED_CONNECT: return "The device connected";
162
163 case XRV_SHUTTINGDOWN: return "The device is shutting down";
164 case XRV_GNSSCONFIGURATIONERROR:return "A configuration item was refused by the GNSS module";
165 case XRV_GNSSCOMMTIMEOUT: return "The communication with the GNSS module timed out";
166 case XRV_GNSSERROR: return "Communication between the device and the GNSS module failed";
167 case XRV_DEVICE_NOT_CALIBRATED: return "The EMTS of the device does not contain calibration data";
168
169 default: return "!!Undefined Result Value!!";
170 }
171 }
172
173 /*! @} */