.SH NAME |
| 4 |
sane\-mustek \- SANE backend for Mustek SCSI flatbed scanners (and some other devices) |
| 5 |
.SH DESCRIPTION |
| 6 |
The |
| 7 |
.B sane\-mustek |
| 8 |
library implements a SANE (Scanner Access Now Easy) backend that provides access |
| 9 |
to Mustek (and some relabeled Trust and Primax) SCSI and parport flatbed |
| 10 |
scanners. At present, the following scanners are known to work more or less |
| 11 |
with this backend: |
| 12 |
.PP |
| 13 |
.RS |
| 14 |
Paragon MFS-6000CX |
| 15 |
.br |
| 16 |
Paragon MFS-12000CX |
| 17 |
.br |
| 18 |
Paragon MFC-600S, 600 II CD, ScanMagic 600 II SP |
| 19 |
.br |
| 20 |
Paragon MFC-800S, 800 II SP |
| 21 |
.br |
| 22 |
Paragon MFS-6000SP |
| 23 |
.br |
| 24 |
Paragon MFS-8000SP |
| 25 |
.br |
| 26 |
Paragon MFS-1200SP, MFS-12000SP |
| 27 |
.br |
| 28 |
ScanExpress 6000SP |
| 29 |
.br |
| 30 |
ScanExpress 12000SP, 12000SP Plus, Paragon 1200 III SP, ScanMagic 9636S, 9636S Plus |
| 31 |
.br |
| 32 |
Paragon 1200 LS |
| 33 |
.br |
| 34 |
ScanExpress A3 SP |
| 35 |
.br |
| 36 |
Paragon 1200 SP Pro |
| 37 |
.br |
| 38 |
Paragon 1200 A3 Pro |
| 39 |
.br |
| 40 |
Paragon 600 II EP |
| 41 |
.br |
| 42 |
Paragon 600 II N |
| 43 |
.br |
| 44 |
Trust Imagery 1200 |
| 45 |
.br |
| 46 |
Trust Imagery 1200 SP |
| 47 |
.br |
| 48 |
Trust Imagery 4800 SP |
| 49 |
.br |
| 50 |
Trust SCSI Connect 19200 |
| 51 |
.br |
| 52 |
Primax Compact 4800 SCSI |
| 53 |
.br |
| 54 |
.RE |
| 55 |
.PP |
| 56 |
More details can be found on the Mustek SCSI backend homepage |
| 57 |
.IR http://www.meier\-geinitz.de/sane/mustek\-backend/ . |
| 58 |
.PP |
| 59 |
Don't mix up MFS (Paragon), Pro and ScanExpress models! They're |
| 60 |
completely different. Check the exact model name! |
| 61 |
.PP |
| 62 |
Note that most of the above scanners come with a SCSI interface. The only |
| 63 |
non-SCSI scanners that have some support at this point is the 600 II N and 600 |
| 64 |
II EP scanners. The former one comes with its own parallel port adapter (i.e., |
| 65 |
it does |
| 66 |
.I not |
| 67 |
attach to the printer port). Both scanners use the SCSI protocol internally, |
| 68 |
too. More info on how to use these parallel port scanners can be found below in |
| 69 |
section |
| 70 |
.BR "PARALLEL PORT SCANNERS" . |
| 71 |
Other parallel port scanners are not supported by this backend but you may be |
| 72 |
successful using the Mustek parallel port backend mustek_pp, see |
| 73 |
.BR sane\-mustek_pp (5). |
| 74 |
USB scanners are also not supported by this backend but the ma1509, mustek_usb, |
| 75 |
gt68xx, and plustek backends include support for some of them, see |
| 76 |
.BR sane\-ma1509 (5), |
| 77 |
.BR sane\-mustek_usb (5), |
| 78 |
.BR sane\-gt68xx "(5), and" |
| 79 |
.BR sane\-plustek (5). |
| 80 |
.PP |
| 81 |
Mustek scanners have no protection against exceeding the physical scan |
| 82 |
area height. That is, if a scan is attempted with a height that |
| 83 |
exceeds the height of the scan surface, the scanner begins making loud |
| 84 |
noises and the scan mechanism may be damaged. Thus, if you hear such |
| 85 |
a noise, IMMEDIATELY turn off the scanner. This shouldn't happen if |
| 86 |
your scanner is in the list of known scanners. There is more |
| 87 |
information in the |
| 88 |
.I /usr/share/doc/libsane/PROBLEMS |
| 89 |
file. |
| 90 |
.PP |
| 91 |
If you own a Mustek (or Trust) scanner other than the ones listed |
| 92 |
above that works with this backend, please let us know by sending the |
| 93 |
scanner's exact model name (look at the front and back of the scanner) |
| 94 |
and a debug output to |
| 95 |
.IR sane\[email protected] . |
| 96 |
You can get the debug output by setting the environment variable |
| 97 |
.B SANE_DEBUG_MUSTEK |
| 98 |
to 5 and showing the list of available scanners with |
| 99 |
.IR "scanimage \-L" . |
| 100 |
Please send all of it to the mailing list. You must be subscribed to sane\-devel |
| 101 |
before you can send mail to the list. See |
| 102 |
.I http://www.sane\-project.org/mailing\-lists.html |
| 103 |
for details. |
| 104 |
|
| 105 |
.SH "DEVICE NAMES" |
| 106 |
This backend expects device names of the form: |
| 107 |
.PP |
| 108 |
.RS |
| 109 |
.I special |
| 110 |
.RE |
| 111 |
.PP |
| 112 |
Where |
| 113 |
.I special |
| 114 |
is either the path-name for the special device that corresponds to a |
| 115 |
SCSI scanner or the port number at which the parallel port scanners can |
| 116 |
be found (see section |
| 117 |
.B "PARALLEL PORT SCANNERS" |
| 118 |
below). For SCSI scanners, the special device name must be a generic SCSI |
| 119 |
device or a symlink to such a device. The program |
| 120 |
.BR sane\-find\-scanner (1) |
| 121 |
helps to find out the correct device. Under Linux, such a device name |
| 122 |
could be |
| 123 |
.I /dev/sg0 |
| 124 |
or |
| 125 |
.IR /dev/sg3 , |
| 126 |
for example. See |
| 127 |
.BR sane\-scsi (5) |
| 128 |
for details. |
| 129 |
.SH CONFIGURATION |
| 130 |
The contents of the |
| 131 |
.I mustek.conf |
| 132 |
file is a list of options and device names that correspond to Mustek |
| 133 |
scanners. Empty lines and lines starting with a hash mark (#) are |
| 134 |
ignored. See |
| 135 |
.BR sane\-scsi (5) |
| 136 |
on details of what constitutes a valid device name. |
| 137 |
.PP |
| 138 |
The supported options are |
| 139 |
.BR linedistance\-fix , |
| 140 |
.BR lineart\-fix , |
| 141 |
.BR legal\-size , |
| 142 |
.BR buffersize , |
| 143 |
.BR blocksize , |
| 144 |
.BR strip\-height , |
| 145 |
.BR disable\-double\-buffering , |
| 146 |
.BR disable\-backtracking , |
| 147 |
and |
| 148 |
.BR force\-wait . |
| 149 |
.PP |
| 150 |
Options come in two flavors: global and positional ones. Global |
| 151 |
options apply to all devices managed by the backend whereas positional |
| 152 |
options apply just to the most recently mentioned device. Note that |
| 153 |
this means that the order in which the options appear matters! |
| 154 |
.PP |
| 155 |
Option |
| 156 |
.B linedistance\-fix |
| 157 |
is positional and works around a problem that occurs with some SCSI |
| 158 |
controllers (notably the ncr810 controller under Linux). If color |
| 159 |
scans have horizontal stripes and/or the colors are off, then it's |
| 160 |
likely that your controller suffers from this problem. Turning on |
| 161 |
this option usually fixes the problem. |
| 162 |
.PP |
| 163 |
Option |
| 164 |
.B lineart\-fix |
| 165 |
is positional and works around a timing problem that seems to exist |
| 166 |
with certain MFS-12000SP scanners. The problem manifests itself in |
| 167 |
dropped lines when scanning in lineart mode. Turning on this option |
| 168 |
should fix the problem but may slow down scanning a bit. |
| 169 |
.PP |
| 170 |
Option |
| 171 |
.B legal\-size |
| 172 |
is positional and sets the size of the scan area to Legal format. Set this |
| 173 |
option if you own a Paragon 12000 LS. It can't be distinguished by |
| 174 |
software from a ScanExpress 12000 SP (ISO A4 format). |
| 175 |
.PP |
| 176 |
Option |
| 177 |
.B buffersize |
| 178 |
is a positional option that overrides the default value set for the size of |
| 179 |
the SCSI buffer. The buffer size is specified in kilobytes. The default value |
| 180 |
is 128. Because of double buffering the buffer actually sent to the scanner |
| 181 |
is half the size of this value. Try to increase this value to achieve higher |
| 182 |
scan speeds. Note that some ScanExpress scanners don't like buffer sizes above |
| 183 |
64 kb (buffersize = 128). If your sg driver can't set SCSI buffer sizes at |
| 184 |
runtime you may have to change that value, too. See |
| 185 |
.BR sane\-scsi (5) |
| 186 |
for details. |
| 187 |
.PP |
| 188 |
Option |
| 189 |
.B blocksize |
| 190 |
is a positional option that overrides the default value set for the maximum |
| 191 |
amount of data scanned in one block. The buffer size is specified in |
| 192 |
kilobytes. Some scanners freeze if this value is bigger than 2048. The default |
| 193 |
value is 1 GB (so effectively no limit) for most scanners. Don't change this |
| 194 |
value if you don't know exactly what you do. |
| 195 |
.PP |
| 196 |
Option |
| 197 |
.B strip\-height |
| 198 |
is a global option that limits the maximum height of the strip scanned with a |
| 199 |
single SCSI read command. The height is specified in inches and may contain a |
| 200 |
fractional part (e.g., 1.5). Setting the strip\-height to a small value (one |
| 201 |
inch, for example) reduces the likelihood of encountering problems with SCSI |
| 202 |
driver timeouts and/or timeouts with other devices on the same SCSI bus. |
| 203 |
Unfortunately, it also increases scan times. With current SCSI adapters and |
| 204 |
drivers this option shouldn't be needed any more. |
| 205 |
.PP |
| 206 |
Option |
| 207 |
.B disable\-double\-buffering |
| 208 |
is a global option. If set, the backend will only send one buffer at a time to |
| 209 |
the scanner. Try this option if you have trouble while scanning, e.g. SCSI |
| 210 |
errors, freezes, or the first few cm are repeated over and over again in your |
| 211 |
image. |
| 212 |
.PP |
| 213 |
Option |
| 214 |
.B disable\-backtracking |
| 215 |
is a positional option. If set, the scanner will not move back its slider |
| 216 |
after each SCSI buffer is filled (`backtracking'). Setting this option will |
| 217 |
lead to faster scans but may also produce horizontal stripes. This option |
| 218 |
doesn't work with every scanner (only some of the paragon models can modify |
| 219 |
backtracking). |
| 220 |
.PP |
| 221 |
Finally, |
| 222 |
.B force\-wait |
| 223 |
is a global option. If set, the backend will wait until the device is ready |
| 224 |
before sending the inquiry command. Further more the backend will force the |
| 225 |
scan slider to return to its starting position (not implemented for all |
| 226 |
scanners). This option may be necessary with the 600 II N or when |
| 227 |
.BR scanimage (1) |
| 228 |
is used multiple times (e.g. in scripts). The default is off (not set). |
| 229 |
.PP |
| 230 |
A sample configuration file is shown below: |
| 231 |
.PP |
| 232 |
.RS |
| 233 |
# limit strip height of all scanners to 1.5 inches: |
| 234 |
.br |
| 235 |
option strip\-height 1.5 |
| 236 |
.br |
| 237 |
.br |
| 238 |
/dev/scanner # first Mustek scanner |
| 239 |
.br |
| 240 |
# 1 MB buffer for /dev/scanner: |
| 241 |
.br |
| 242 |
option buffersize 1024 |
| 243 |
.br |
| 244 |
/dev/sge # second Mustek scanner |
| 245 |
.br |
| 246 |
# turn on fixes for /dev/sge: |
| 247 |
.br |
| 248 |
option lineart\-fix |
| 249 |
.br |
| 250 |
option linedistance\-fix |
| 251 |
.RE |
| 252 |
|
| 253 |
.SH "SCSI ADAPTER TIPS" |
| 254 |
.PP |
| 255 |
You need a SCSI adapter for the SCSI scanners. Even if the connector is the |
| 256 |
same as that of parallel port scanners, connecting it to the computers |
| 257 |
parallel port will NOT work. |
| 258 |
.PP |
| 259 |
Mustek SCSI scanners are typically delivered with an ISA SCSI adapter. |
| 260 |
Unfortunately, that adapter is not worth much since it is not |
| 261 |
interrupt driven. It is (sometimes) possible to get the supplied card |
| 262 |
to work, but without interrupt line, scanning will be very slow and put |
| 263 |
so much load on the system, that it becomes almost unusable for other tasks. |
| 264 |
.PP |
| 265 |
If you already have a working SCSI controller in your system, you |
| 266 |
should consider that Mustek scanners do not support the SCSI-2 |
| 267 |
disconnect/reconnect protocol and hence tie up the SCSI bus while a |
| 268 |
scan is in progress. This means that no other SCSI device on the same |
| 269 |
bus can be accessed while a scan is in progress. |
| 270 |
.PP |
| 271 |
Because the Mustek-supplied adapter is not worth much and because |
| 272 |
Mustek scanners do not support the SCSI-2 disconnect/reconnect |
| 273 |
protocol, it is recommended to install a separate (cheap) SCSI |
| 274 |
controller for Mustek scanners. For example, ncr810 based cards are |
| 275 |
known to work fine and cost as little as fifty US dollars. |
| 276 |
.PP |
| 277 |
For Mustek scanners, it is typically necessary to configure the low-level SCSI |
| 278 |
driver to disable synchronous transfers (sync negotiation), tagged command |
| 279 |
queuing, and target disconnects. See |
| 280 |
.BR sane\-scsi (5) |
| 281 |
for driver- and platform-specific information. |
| 282 |
.PP |
| 283 |
The ScanExpress models have sometimes trouble with high resolution |
| 284 |
color mode. If you encounter sporadic corrupted images (parts duplicated |
| 285 |
or shifted horizontally) kill all other applications before scanning |
| 286 |
and (if sufficient memory is available) disable swapping. |
| 287 |
.PP |
| 288 |
Details on how to get the Mustek SCSI adapters and other cards running can be |
| 289 |
found at |
| 290 |
.IR http://www.meier\-geinitz.de/sane/mustek\-backend/#SCSI . |
| 291 |
|
| 292 |
.SH "PARALLEL PORT SCANNERS" |
| 293 |
This backend has support for the Paragon 600 II EP and Paragon 600 II N parallel |
| 294 |
port scanners. Note that the latter scanner comes with its own ISA card that |
| 295 |
implements a funky parallel port (in other words, the scanner does not connected |
| 296 |
to the printer parallel port). |
| 297 |
.PP |
| 298 |
These scanners can be configured by listing the port number |
| 299 |
of the adapter or the parallel port in the mustek.conf file. Valid port numbers |
| 300 |
for the 600 II N are |
| 301 |
.IR 0x26b ", " 0x2ab ", " 0x2eb ", " 0x22b ", " 0x32b ", " 0x36b ", " |
| 302 |
.IR 0x3ab ", " 0x3eb . |
| 303 |
For the 600 II EP use one of these: |
| 304 |
.IR parport0 ", " parport1 ", " parport2 ", " 0x378 ", " 0x278 ", " 0x3bc . |
| 305 |
Pick one that doesn't conflict with the other hardware in your computer. Put |
| 306 |
only one number on a single line. Example: |
| 307 |
.PP |
| 308 |
.RS |
| 309 |
.I 0x3eb |
| 310 |
.RE |
| 311 |
.PP |
| 312 |
Note that for these scanners usually root privileges are required to access the |
| 313 |
I/O ports. Thus, either make frontends such as |
| 314 |
.BR scanimage (1) |
| 315 |
and |
| 316 |
.BR xscanimage (1) |
| 317 |
setuid root (generally not recommended for security reasons) or, alternatively, |
| 318 |
access this backend through the network daemon |
| 319 |
.BR saned (8). |
| 320 |
.PP |
| 321 |
If the Mustek backend blocks while sending the inquiry command to the scanner, |
| 322 |
add the option |
| 323 |
.B force\-wait |
| 324 |
to |
| 325 |
.IR mustek.conf . |
| 326 |
.PP |
| 327 |
Also note that after a while of no activity, some scanners themselves (not |
| 328 |
the SANE backend) turns off their CCFL lamps. This shutdown is not always |
| 329 |
perfect with the result that the lamp sometimes continues to glow |
| 330 |
dimly at one end. This doesn't appear to be dangerous since as soon as |
| 331 |
you use the scanner again, the lamp turns back on to the normal high |
| 332 |
brightness. However, the first image scanned after such a shutdown may |
| 333 |
have stripes and appear to be over-exposed. When this happens, just |
| 334 |
take another scan, and the image will be fine. |
| 335 |
|
| 336 |
.SH FILES |
| 337 |
.TP |
| 338 |
.I /etc/sane.d/mustek.conf |
| 339 |
The backend configuration file (see also description of |
| 340 |
.B SANE_CONFIG_DIR |
| 341 |
below). |
| 342 |
.TP |
| 343 |
.I /usr/lib/x86_64-linux-gnu/sane/libsane\-mustek.a |
| 344 |
The static library implementing this backend. |
| 345 |
.TP |
| 346 |
.I /usr/lib/x86_64-linux-gnu/sane/libsane\-mustek.so |
| 347 |
The shared library implementing this backend (present on systems that |
| 348 |
support dynamic loading). |
| 349 |
|
| 350 |
.SH ENVIRONMENT |
| 351 |
.TP |
| 352 |
.B SANE_CONFIG_DIR |
| 353 |
This environment variable specifies the list of directories that may |
| 354 |
contain the configuration file. On *NIX systems, the directories are |
| 355 |
separated by a colon (`:'), under OS/2, they are separated by a |
| 356 |
semi-colon (`;'). If this variable is not set, the configuration file |
| 357 |
is searched in two default directories: first, the current working |
| 358 |
directory (".") and then in |
| 359 |
.IR /etc/sane.d . |
| 360 |
If the value of the |
| 361 |
environment variable ends with the directory separator character, then |
| 362 |
the default directories are searched after the explicitly specified |
| 363 |
directories. For example, setting |
| 364 |
.B SANE_CONFIG_DIR |
| 365 |
to "/tmp/config:" would result in directories |
| 366 |
.IR "tmp/config" , |
| 367 |
.IR "." , |
| 368 |
and |
| 369 |
.I "/etc/sane.d" |
| 370 |
being searched (in this order). |
| 371 |
.TP |
| 372 |
.B SANE_DEBUG_MUSTEK |
| 373 |
If the library was compiled with debug support enabled, this |
| 374 |
environment variable controls the debug level for this backend. Higher |
| 375 |
debug levels increase the verbosity of the output. |
| 376 |
|
| 377 |
.ft CR |
| 378 |
.nf |
| 379 |
Value Description |
| 380 |
0 no output |
| 381 |
1 print fatal errors |
| 382 |
2 print important messages |
| 383 |
3 print non-fatal errors and less important messages |
| 384 |
4 print all but debugging messages |
| 385 |
5 print everything |
| 386 |
.fi |
| 387 |
.ft R |
| 388 |
|
| 389 |
Example: |
| 390 |
export SANE_DEBUG_MUSTEK=4 |
| 391 |
|
| 392 |
.SH "SEE ALSO" |
| 393 |
.BR sane (7), |
| 394 |
.BR sane\-find\-scanner (1), |
| 395 |
.BR sane\-scsi (5), |
| 396 |
.BR sane\-mustek_usb (5), |
| 397 |
.BR sane\-gt68xx (5), |
| 398 |
.BR sane\-plustek (5), |
| 399 |
.BR sane\-mustek_pp (5), |
| 400 |
.BR sane\-ma1509 (5), |
| 401 |
.BR scanimage (1), |
| 402 |
.BR xscanimage (1) |
| 403 |
|
| 404 |
.br |
| 405 |
.I /usr/share/doc/libsane/mustek/mustek.CHANGES |
| 406 |
.br |
| 407 |
.I http://www.meier\-geinitz.de/sane/mustek\-backend/ |
| 408 |
|
| 409 |
.SH AUTHOR |
| 410 |
David Mosberger, Andreas Czechanowski, Andreas Bolsch (SE extensions), |
| 411 |
Henning Meier-Geinitz, James Perry (600 II EP). |
| 412 |
|
| 413 |
.SH BUGS |
| 414 |
Scanning with the SCSI adapters supplied by Mustek is very slow at |
| 415 |
high resolutions and wide scan areas. |
| 416 |
.PP |
| 417 |
Some scanners (e.g. Paragon 1200 A3 + Pro, SE A3) need more testing. |
| 418 |
.PP |
| 419 |
The gamma table supports only 256 colors, even if some scanners can do more. |
| 420 |
.PP |
| 421 |
More detailed bug information is available at the Mustek backend |
| 422 |
homepage: |
| 423 |
.IR http://www.meier\-geinitz.de/sane/mustek\-backend/ . |