1 # Configuration file contributed by Arseny Klimovsky.
2
3
4 # Created for board DH67BL using information from Intel Desktop Utilities and BIOS
5 # "FRONT" and "REAR" fan labels correspond to the motherboard
6 # headers, but not necessarily the actual fan locations.
7
8 chip "nct6775-isa-0290"
9
10 # Fans
11 label fan1 "Rear fan"
12 set fan1_min 250 # From IDU
13
14 label fan2 "CPU fan"
15 set fan2_min 250 # From IDU
16
17 label fan3 "Front fan"
18 set fan3_min 250 # From IDU
19
20 # There is no fan4 on the board
21 ignore fan4
22
23 # Voltages
24
25 # Processor Vcc
26 label in0 "Vcore"
27 set in0_min 0.6 # From IDU
28 set in0_max 1.6 # From IDU
29
30 # This should be "12 Volts", but computations are strange
31 label in1 "+12V"
32 compute in1 11*@, @/11
33 set in1_min 11.1 # From IDU
34 set in1_max 12.9 # From IDU
35
36 # AVCC(?) - Not shown in BIOS or IDU
37 label in2 "AVCC"
38 set in2_min 3.0 # same as +3.3V
39 set in2_max 3.6 # same as +3.3V
40
41 # +3.3 Volts
42 label in3 "+3.3V"
43 set in3_min 3.0 # from IDU
44 set in3_max 3.6 # from IDU
45
46 # +5 Volts
47 label in4 "+5V"
48 compute in4 5*@, @/5
49 set in4_min 4.6 # from IDU
50 set in4_max 5.4 # from IDU
51
52 # Memory Vcc ("SDRAM Vcc" in IDU)
53 label in5 "MemV"
54 compute in5 1.5*@, @/1.5
55 set in5_min 0.4 # from IDU
56 set in5_max 2.0 # from IDU
57
58 # PCH Vcc
59 label in6 "PCHV"
60 set in6_min 0.6 # from IDU
61 set in6_max 1.6 # from IDU
62
63 # +3.3 Volt Standby
64 label in7 "3VSB"
65 set in7_min 3.0 # from IDU
66 set in7_max 3.6 # from IDU
67
68 # VBAT(?) - Not shown in BIOS or IDU
69 label in8 "Vbat"
70
71 # It shows +2.050 V, seems to be not used
72 ignore cpu0_vid
73
74 # Temperatures
75
76 # Labeled as "SYSTIN"
77 # Guess!
78 label temp1 "VR temp"
79 set temp1_max 90 # From IDU
80 set temp1_max_hyst 75 # From IDU
81 # Labeled as "CPUTIN"
82 label temp2 "CPU temp"
83 set temp2_max 93 # From IDU
84 set temp2_max_hyst 75 # From IDU
85 # Labeled as "PECI Agent 0"
86 # Guess!
87 label temp3 "Memory DIMM temp"
88 set temp3_max 90 # From IDU
89 set temp3_max_hyst 75 # From IDU
90 # Labeled as "PCH_CHIP_TEMP"
91 label temp4 "PCH temp"
92