| 1 |
# Configuration file contributed by Eric Le Bras. |
| 2 |
|
| 3 |
|
| 4 |
# Configuration file for Intel D201GLY2 motherboard |
| 5 |
# Hardware monitor subsystem controlled by Winbond W83627DHG-B I/O controller. |
| 6 |
# Created using information from BIOS and board documentation. |
| 7 |
|
| 8 |
chip "w83627dhg-*" |
| 9 |
|
| 10 |
label in1 "+12V" |
| 11 |
label in4 "+5V" |
| 12 |
label in6 "+1.5V" |
| 13 |
|
| 14 |
# in5 is obviously unconnected, so ignore it |
| 15 |
ignore in5 |
| 16 |
|
| 17 |
compute in1 @*(55/8), @/(55/8) |
| 18 |
compute in4 @*(1+18/10), @/(1+18/10) |
| 19 |
|
| 20 |
set in1_min 12.0 * 0.95 |
| 21 |
set in1_max 12.0 * 1.05 |
| 22 |
set in4_min 5.0 * 0.95 |
| 23 |
set in4_max 5.0 * 1.05 |
| 24 |
set in6_min 1.5 * 0.90 |
| 25 |
set in6_max 1.5 * 1.10 |
| 26 |
|
| 27 |
label fan1 "Chassis fan" |
| 28 |
label fan2 "CPU fan" |
| 29 |
|
| 30 |
# By default the D201GLY2 has a passive heatsink. If the optional active |
| 31 |
# heatsink is present, then one of the following lines is to be commented out |
| 32 |
# (very likely fan2, though not tried). |
| 33 |
ignore fan2 |
| 34 |
ignore fan3 |
| 35 |
ignore fan4 |
| 36 |
|
| 37 |
label temp1 "Sys temp" |
| 38 |
label temp2 "CPU temp" |
| 39 |
ignore temp3 |
| 40 |
|
| 41 |
set temp1_max 50 |
| 42 |
set temp1_max_hyst 48 |
| 43 |
|
| 44 |
ignore cpu0_vid |
| 45 |
ignore intrusion0 |