| 1 |
/* SPDX-License-Identifier: GPL-2.0-or-later */ |
| 2 |
/* |
| 3 |
* tmon.h contains data structures and constants used by TMON |
| 4 |
* |
| 5 |
* Copyright (C) 2012 Intel Corporation. All rights reserved. |
| 6 |
* |
| 7 |
* Author Name Jacob Pan <[email protected]> |
| 8 |
*/ |
| 9 |
|
| 10 |
#ifndef TMON_H |
| 11 |
#define TMON_H |
| 12 |
|
| 13 |
#define MAX_DISP_TEMP 125 |
| 14 |
#define MAX_CTRL_TEMP 105 |
| 15 |
#define MIN_CTRL_TEMP 40 |
| 16 |
#define MAX_NR_TZONE 16 |
| 17 |
#define MAX_NR_CDEV 32 |
| 18 |
#define MAX_NR_TRIP 16 |
| 19 |
#define MAX_NR_CDEV_TRIP 12 /* number of cooling devices that can bind |
| 20 |
* to a thermal zone trip. |
| 21 |
*/ |
| 22 |
#define MAX_TEMP_KC 140000 |
| 23 |
/* starting char position to draw sensor data, such as tz names |
| 24 |
* trip point list, etc. |
| 25 |
*/ |
| 26 |
#define DATA_LEFT_ALIGN 10 |
| 27 |
#define NR_LINES_TZDATA 1 |
| 28 |
#define TMON_LOG_FILE "/var/tmp/tmon.log" |
| 29 |
|
| 30 |
#include <sys/time.h> |
| 31 |
#include <pthread.h> |
| 32 |
|
| 33 |
extern unsigned long ticktime; |
| 34 |
extern double time_elapsed; |
| 35 |
extern unsigned long target_temp_user; |
| 36 |
extern int dialogue_on; |
| 37 |
extern char ctrl_cdev[]; |
| 38 |
extern pthread_mutex_t input_lock; |
| 39 |
extern int tmon_exit; |
| 40 |
extern int target_thermal_zone; |
| 41 |
/* use fixed size record to simplify data processing and transfer |
| 42 |
* TBD: more info to be added, e.g. programmable trip point data. |
| 43 |
*/ |
| 44 |
struct thermal_data_record { |
| 45 |
struct timeval tv; |
| 46 |
unsigned long temp[MAX_NR_TZONE]; |
| 47 |
double pid_out_pct; |
| 48 |
}; |
| 49 |
|
| 50 |
struct cdev_info { |
| 51 |
char type[64]; |
| 52 |
int instance; |
| 53 |
unsigned long max_state; |
| 54 |
unsigned long cur_state; |
| 55 |
unsigned long flag; |
| 56 |
}; |
| 57 |
|
| 58 |
enum trip_type { |
| 59 |
THERMAL_TRIP_CRITICAL, |
| 60 |
THERMAL_TRIP_HOT, |
| 61 |
THERMAL_TRIP_PASSIVE, |
| 62 |
THERMAL_TRIP_ACTIVE, |
| 63 |
NR_THERMAL_TRIP_TYPE, |
| 64 |
}; |
| 65 |
|
| 66 |
struct trip_point { |
| 67 |
enum trip_type type; |
| 68 |
unsigned long temp; |
| 69 |
unsigned long hysteresis; |
| 70 |
int attribute; /* programmability etc. */ |
| 71 |
}; |
| 72 |
|
| 73 |
/* thermal zone configuration information, binding with cooling devices could |
| 74 |
* change at runtime. |
| 75 |
*/ |
| 76 |
struct tz_info { |
| 77 |
char type[256]; /* e.g. acpitz */ |
| 78 |
int instance; |
| 79 |
int passive; /* active zone has passive node to force passive mode */ |
| 80 |
int nr_cdev; /* number of cooling device binded */ |
| 81 |
int nr_trip_pts; |
| 82 |
struct trip_point tp[MAX_NR_TRIP]; |
| 83 |
unsigned long cdev_binding; /* bitmap for attached cdevs */ |
| 84 |
/* cdev bind trip points, allow one cdev bind to multiple trips */ |
| 85 |
unsigned long trip_binding[MAX_NR_CDEV]; |
| 86 |
}; |
| 87 |
|
| 88 |
struct tmon_platform_data { |
| 89 |
int nr_tz_sensor; |
| 90 |
int nr_cooling_dev; |
| 91 |
/* keep track of instance ids since there might be gaps */ |
| 92 |
int max_tz_instance; |
| 93 |
int max_cdev_instance; |
| 94 |
struct tz_info *tzi; |
| 95 |
struct cdev_info *cdi; |
| 96 |
}; |
| 97 |
|
| 98 |
struct control_ops { |
| 99 |
void (*set_ratio)(unsigned long ratio); |
| 100 |
unsigned long (*get_ratio)(unsigned long ratio); |
| 101 |
|
| 102 |
}; |
| 103 |
|
| 104 |
enum cdev_types { |
| 105 |
CDEV_TYPE_PROC, |
| 106 |
CDEV_TYPE_FAN, |
| 107 |
CDEV_TYPE_MEM, |
| 108 |
CDEV_TYPE_NR, |
| 109 |
}; |
| 110 |
|
| 111 |
/* REVISIT: the idea is to group sensors if possible, e.g. on intel mid |
| 112 |
* we have "skin0", "skin1", "sys", "msicdie" |
| 113 |
* on DPTF enabled systems, we might have PCH, TSKN, TAMB, etc. |
| 114 |
*/ |
| 115 |
enum tzone_types { |
| 116 |
TZONE_TYPE_ACPI, |
| 117 |
TZONE_TYPE_PCH, |
| 118 |
TZONE_TYPE_NR, |
| 119 |
}; |
| 120 |
|
| 121 |
/* limit the output of PID controller adjustment */ |
| 122 |
#define LIMIT_HIGH (95) |
| 123 |
#define LIMIT_LOW (2) |
| 124 |
|
| 125 |
struct pid_params { |
| 126 |
double kp; /* Controller gain from Dialog Box */ |
| 127 |
double ki; /* Time-constant for I action from Dialog Box */ |
| 128 |
double kd; /* Time-constant for D action from Dialog Box */ |
| 129 |
double ts; |
| 130 |
double k_lpf; |
| 131 |
|
| 132 |
double t_target; |
| 133 |
double y_k; |
| 134 |
}; |
| 135 |
|
| 136 |
extern int init_thermal_controller(void); |
| 137 |
extern void controller_handler(const double xk, double *yk); |
| 138 |
|
| 139 |
extern struct tmon_platform_data ptdata; |
| 140 |
extern struct pid_params p_param; |
| 141 |
|
| 142 |
extern FILE *tmon_log; |
| 143 |
extern int cur_thermal_record; /* index to the trec array */ |
| 144 |
extern struct thermal_data_record trec[]; |
| 145 |
extern const char *trip_type_name[]; |
| 146 |
extern unsigned long no_control; |
| 147 |
|
| 148 |
extern void initialize_curses(void); |
| 149 |
extern void show_controller_stats(char *line); |
| 150 |
extern void show_title_bar(void); |
| 151 |
extern void setup_windows(void); |
| 152 |
extern void disable_tui(void); |
| 153 |
extern void show_sensors_w(void); |
| 154 |
extern void show_data_w(void); |
| 155 |
extern void write_status_bar(int x, char *line); |
| 156 |
extern void show_control_w(); |
| 157 |
|
| 158 |
extern void show_cooling_device(void); |
| 159 |
extern void show_dialogue(void); |
| 160 |
extern int update_thermal_data(void); |
| 161 |
|
| 162 |
extern int probe_thermal_sysfs(void); |
| 163 |
extern void free_thermal_data(void); |
| 164 |
extern void resize_handler(int sig); |
| 165 |
extern void set_ctrl_state(unsigned long state); |
| 166 |
extern void get_ctrl_state(unsigned long *state); |
| 167 |
extern void *handle_tui_events(void *arg); |
| 168 |
extern int sysfs_set_ulong(char *path, char *filename, unsigned long val); |
| 169 |
extern int zone_instance_to_index(int zone_inst); |
| 170 |
extern void close_windows(void); |
| 171 |
|
| 172 |
#define PT_COLOR_DEFAULT 1 |
| 173 |
#define PT_COLOR_HEADER_BAR 2 |
| 174 |
#define PT_COLOR_ERROR 3 |
| 175 |
#define PT_COLOR_RED 4 |
| 176 |
#define PT_COLOR_YELLOW 5 |
| 177 |
#define PT_COLOR_GREEN 6 |
| 178 |
#define PT_COLOR_BRIGHT 7 |
| 179 |
#define PT_COLOR_BLUE 8 |
| 180 |
|
| 181 |
/* each thermal zone uses 12 chars, 8 for name, 2 for instance, 2 space |
| 182 |
* also used to list trip points in forms of AAAC, which represents |
| 183 |
* A: Active |
| 184 |
* C: Critical |
| 185 |
*/ |
| 186 |
#define TZONE_RECORD_SIZE 12 |
| 187 |
#define TZ_LEFT_ALIGN 32 |
| 188 |
#define CDEV_NAME_SIZE 20 |
| 189 |
#define CDEV_FLAG_IN_CONTROL (1 << 0) |
| 190 |
|
| 191 |
/* dialogue box starts */ |
| 192 |
#define DIAG_X 48 |
| 193 |
#define DIAG_Y 8 |
| 194 |
#define THERMAL_SYSFS "/sys/class/thermal" |
| 195 |
#define CDEV "cooling_device" |
| 196 |
#define TZONE "thermal_zone" |
| 197 |
#define TDATA_LEFT 16 |
| 198 |