* pid.c PID controller for testing cooling devices |
| 4 |
* |
| 5 |
* Copyright (C) 2012 Intel Corporation. All rights reserved. |
| 6 |
* |
| 7 |
* Author Name Jacob Pan <[email protected]> |
| 8 |
*/ |
| 9 |
|
| 10 |
#include <unistd.h> |
| 11 |
#include <stdio.h> |
| 12 |
#include <stdlib.h> |
| 13 |
#include <string.h> |
| 14 |
#include <stdint.h> |
| 15 |
#include <sys/types.h> |
| 16 |
#include <dirent.h> |
| 17 |
#include <libintl.h> |
| 18 |
#include <ctype.h> |
| 19 |
#include <assert.h> |
| 20 |
#include <time.h> |
| 21 |
#include <limits.h> |
| 22 |
#include <math.h> |
| 23 |
#include <sys/stat.h> |
| 24 |
#include <syslog.h> |
| 25 |
|
| 26 |
#include "tmon.h" |
| 27 |
|
| 28 |
/************************************************************************** |
| 29 |
* PID (Proportional-Integral-Derivative) controller is commonly used in |
| 30 |
* linear control system, consider the process. |
| 31 |
* G(s) = U(s)/E(s) |
| 32 |
* kp = proportional gain |
| 33 |
* ki = integral gain |
| 34 |
* kd = derivative gain |
| 35 |
* Ts |
| 36 |
* We use type C Alan Bradley equation which takes set point off the |
| 37 |
* output dependency in P and D term. |
| 38 |
* |
| 39 |
* y[k] = y[k-1] - kp*(x[k] - x[k-1]) + Ki*Ts*e[k] - Kd*(x[k] |
| 40 |
* - 2*x[k-1]+x[k-2])/Ts |
| 41 |
* |
| 42 |
* |
| 43 |
***********************************************************************/ |
| 44 |
struct pid_params p_param; |
| 45 |
/* cached data from previous loop */ |
| 46 |
static double xk_1, xk_2; /* input temperature x[k-#] */ |
| 47 |
|
| 48 |
/* |
| 49 |
* TODO: make PID parameters tuned automatically, |
| 50 |
* 1. use CPU burn to produce open loop unit step response |
| 51 |
* 2. calculate PID based on Ziegler-Nichols rule |
| 52 |
* |
| 53 |
* add a flag for tuning PID |
| 54 |
*/ |
| 55 |
int init_thermal_controller(void) |
| 56 |
{ |
| 57 |
|
| 58 |
/* init pid params */ |
| 59 |
p_param.ts = ticktime; |
| 60 |
/* TODO: get it from TUI tuning tab */ |
| 61 |
p_param.kp = .36; |
| 62 |
p_param.ki = 5.0; |
| 63 |
p_param.kd = 0.19; |
| 64 |
|
| 65 |
p_param.t_target = target_temp_user; |
| 66 |
|
| 67 |
return 0; |
| 68 |
} |
| 69 |
|
| 70 |
void controller_reset(void) |
| 71 |
{ |
| 72 |
/* TODO: relax control data when not over thermal limit */ |
| 73 |
syslog(LOG_DEBUG, "TC inactive, relax p-state\n"); |
| 74 |
p_param.y_k = 0.0; |
| 75 |
xk_1 = 0.0; |
| 76 |
xk_2 = 0.0; |
| 77 |
set_ctrl_state(0); |
| 78 |
} |
| 79 |
|
| 80 |
/* To be called at time interval Ts. Type C PID controller. |
| 81 |
* y[k] = y[k-1] - kp*(x[k] - x[k-1]) + Ki*Ts*e[k] - Kd*(x[k] |
| 82 |
* - 2*x[k-1]+x[k-2])/Ts |
| 83 |
* TODO: add low pass filter for D term |
| 84 |
*/ |
| 85 |
#define GUARD_BAND (2) |
| 86 |
void controller_handler(const double xk, double *yk) |
| 87 |
{ |
| 88 |
double ek; |
| 89 |
double p_term, i_term, d_term; |
| 90 |
|
| 91 |
ek = p_param.t_target - xk; /* error */ |
| 92 |
if (ek >= 3.0) { |
| 93 |
syslog(LOG_DEBUG, "PID: %3.1f Below set point %3.1f, stop\n", |
| 94 |
xk, p_param.t_target); |
| 95 |
controller_reset(); |
| 96 |
*yk = 0.0; |
| 97 |
return; |
| 98 |
} |
| 99 |
/* compute intermediate PID terms */ |
| 100 |
p_term = -p_param.kp * (xk - xk_1); |
| 101 |
i_term = p_param.kp * p_param.ki * p_param.ts * ek; |
| 102 |
d_term = -p_param.kp * p_param.kd * (xk - 2 * xk_1 + xk_2) / p_param.ts; |
| 103 |
/* compute output */ |
| 104 |
*yk += p_term + i_term + d_term; |
| 105 |
/* update sample data */ |
| 106 |
xk_1 = xk; |
| 107 |
xk_2 = xk_1; |
| 108 |
|
| 109 |
/* clamp output adjustment range */ |
| 110 |
if (*yk < -LIMIT_HIGH) |
| 111 |
*yk = -LIMIT_HIGH; |
| 112 |
else if (*yk > -LIMIT_LOW) |
| 113 |
*yk = -LIMIT_LOW; |
| 114 |
|
| 115 |
p_param.y_k = *yk; |
| 116 |
|
| 117 |
set_ctrl_state(lround(fabs(p_param.y_k))); |
| 118 |
|
| 119 |
} |