| 1 |
.. SPDX-License-Identifier: GPL-2.0 |
| 2 |
|
| 3 |
======================= |
| 4 |
Universal Flash Storage |
| 5 |
======================= |
| 6 |
|
| 7 |
|
| 8 |
.. Contents |
| 9 |
|
| 10 |
1. Overview |
| 11 |
2. UFS Architecture Overview |
| 12 |
2.1 Application Layer |
| 13 |
2.2 UFS Transport Protocol (UTP) layer |
| 14 |
2.3 UFS Interconnect (UIC) Layer |
| 15 |
3. UFSHCD Overview |
| 16 |
3.1 UFS controller initialization |
| 17 |
3.2 UTP Transfer requests |
| 18 |
3.3 UFS error handling |
| 19 |
3.4 SCSI Error handling |
| 20 |
4. BSG Support |
| 21 |
5. UFS Reference Clock Frequency configuration |
| 22 |
|
| 23 |
|
| 24 |
1. Overview |
| 25 |
=========== |
| 26 |
|
| 27 |
Universal Flash Storage (UFS) is a storage specification for flash devices. |
| 28 |
It aims to provide a universal storage interface for both |
| 29 |
embedded and removable flash memory-based storage in mobile |
| 30 |
devices such as smart phones and tablet computers. The specification |
| 31 |
is defined by JEDEC Solid State Technology Association. UFS is based |
| 32 |
on the MIPI M-PHY physical layer standard. UFS uses MIPI M-PHY as the |
| 33 |
physical layer and MIPI Unipro as the link layer. |
| 34 |
|
| 35 |
The main goals of UFS are to provide: |
| 36 |
|
| 37 |
* Optimized performance: |
| 38 |
|
| 39 |
For UFS version 1.0 and 1.1 the target performance is as follows: |
| 40 |
|
| 41 |
- Support for Gear1 is mandatory (rate A: 1248Mbps, rate B: 1457.6Mbps) |
| 42 |
- Support for Gear2 is optional (rate A: 2496Mbps, rate B: 2915.2Mbps) |
| 43 |
|
| 44 |
Future version of the standard, |
| 45 |
|
| 46 |
- Gear3 (rate A: 4992Mbps, rate B: 5830.4Mbps) |
| 47 |
|
| 48 |
* Low power consumption |
| 49 |
* High random IOPs and low latency |
| 50 |
|
| 51 |
|
| 52 |
2. UFS Architecture Overview |
| 53 |
============================ |
| 54 |
|
| 55 |
UFS has a layered communication architecture which is based on SCSI |
| 56 |
SAM-5 architectural model. |
| 57 |
|
| 58 |
UFS communication architecture consists of the following layers. |
| 59 |
|
| 60 |
2.1 Application Layer |
| 61 |
--------------------- |
| 62 |
|
| 63 |
The Application layer is composed of the UFS command set layer (UCS), |
| 64 |
Task Manager and Device manager. The UFS interface is designed to be |
| 65 |
protocol agnostic, however SCSI has been selected as a baseline |
| 66 |
protocol for versions 1.0 and 1.1 of the UFS protocol layer. |
| 67 |
|
| 68 |
UFS supports a subset of SCSI commands defined by SPC-4 and SBC-3. |
| 69 |
|
| 70 |
* UCS: |
| 71 |
It handles SCSI commands supported by UFS specification. |
| 72 |
* Task manager: |
| 73 |
It handles task management functions defined by the |
| 74 |
UFS which are meant for command queue control. |
| 75 |
* Device manager: |
| 76 |
It handles device level operations and device |
| 77 |
configuration operations. Device level operations mainly involve |
| 78 |
device power management operations and commands to Interconnect |
| 79 |
layers. Device level configurations involve handling of query |
| 80 |
requests which are used to modify and retrieve configuration |
| 81 |
information of the device. |
| 82 |
|
| 83 |
2.2 UFS Transport Protocol (UTP) layer |
| 84 |
-------------------------------------- |
| 85 |
|
| 86 |
The UTP layer provides services for |
| 87 |
the higher layers through Service Access Points. UTP defines 3 |
| 88 |
service access points for higher layers. |
| 89 |
|
| 90 |
* UDM_SAP: Device manager service access point is exposed to device |
| 91 |
manager for device level operations. These device level operations |
| 92 |
are done through query requests. |
| 93 |
* UTP_CMD_SAP: Command service access point is exposed to UFS command |
| 94 |
set layer (UCS) to transport commands. |
| 95 |
* UTP_TM_SAP: Task management service access point is exposed to task |
| 96 |
manager to transport task management functions. |
| 97 |
|
| 98 |
UTP transports messages through UFS protocol information unit (UPIU). |
| 99 |
|
| 100 |
2.3 UFS Interconnect (UIC) Layer |
| 101 |
-------------------------------- |
| 102 |
|
| 103 |
UIC is the lowest layer of the UFS layered architecture. It handles |
| 104 |
the connection between UFS host and UFS device. UIC consists of |
| 105 |
MIPI UniPro and MIPI M-PHY. UIC provides 2 service access points |
| 106 |
to upper layer: |
| 107 |
|
| 108 |
* UIC_SAP: To transport UPIU between UFS host and UFS device. |
| 109 |
* UIO_SAP: To issue commands to Unipro layers. |
| 110 |
|
| 111 |
|
| 112 |
3. UFSHCD Overview |
| 113 |
================== |
| 114 |
|
| 115 |
The UFS host controller driver is based on the Linux SCSI Framework. |
| 116 |
UFSHCD is a low-level device driver which acts as an interface between |
| 117 |
the SCSI Midlayer and PCIe-based UFS host controllers. |
| 118 |
|
| 119 |
The current UFSHCD implementation supports the following functionality: |
| 120 |
|
| 121 |
3.1 UFS controller initialization |
| 122 |
--------------------------------- |
| 123 |
|
| 124 |
The initialization module brings the UFS host controller to active state |
| 125 |
and prepares the controller to transfer commands/responses between |
| 126 |
UFSHCD and UFS device. |
| 127 |
|
| 128 |
3.2 UTP Transfer requests |
| 129 |
------------------------- |
| 130 |
|
| 131 |
Transfer request handling module of UFSHCD receives SCSI commands |
| 132 |
from the SCSI Midlayer, forms UPIUs and issues the UPIUs to the UFS Host |
| 133 |
controller. Also, the module decodes responses received from the UFS |
| 134 |
host controller in the form of UPIUs and intimates the SCSI Midlayer |
| 135 |
of the status of the command. |
| 136 |
|
| 137 |
3.3 UFS error handling |
| 138 |
---------------------- |
| 139 |
|
| 140 |
Error handling module handles Host controller fatal errors, |
| 141 |
Device fatal errors and UIC interconnect layer-related errors. |
| 142 |
|
| 143 |
3.4 SCSI Error handling |
| 144 |
----------------------- |
| 145 |
|
| 146 |
This is done through UFSHCD SCSI error handling routines registered |
| 147 |
with the SCSI Midlayer. Examples of some of the error handling commands |
| 148 |
issues by the SCSI Midlayer are Abort task, LUN reset and host reset. |
| 149 |
UFSHCD Routines to perform these tasks are registered with |
| 150 |
SCSI Midlayer through .eh_abort_handler, .eh_device_reset_handler and |
| 151 |
.eh_host_reset_handler. |
| 152 |
|
| 153 |
In this version of UFSHCD, Query requests and power management |
| 154 |
functionality are not implemented. |
| 155 |
|
| 156 |
4. BSG Support |
| 157 |
============== |
| 158 |
|
| 159 |
This transport driver supports exchanging UFS protocol information units |
| 160 |
(UPIUs) with a UFS device. Typically, user space will allocate |
| 161 |
struct ufs_bsg_request and struct ufs_bsg_reply (see ufs_bsg.h) as |
| 162 |
request_upiu and reply_upiu respectively. Filling those UPIUs should |
| 163 |
be done in accordance with JEDEC spec UFS2.1 paragraph 10.7. |
| 164 |
*Caveat emptor*: The driver makes no further input validations and sends the |
| 165 |
UPIU to the device as it is. Open the bsg device in /dev/ufs-bsg and |
| 166 |
send SG_IO with the applicable sg_io_v4:: |
| 167 |
|
| 168 |
io_hdr_v4.guard = 'Q'; |
| 169 |
io_hdr_v4.protocol = BSG_PROTOCOL_SCSI; |
| 170 |
io_hdr_v4.subprotocol = BSG_SUB_PROTOCOL_SCSI_TRANSPORT; |
| 171 |
io_hdr_v4.response = (__u64)reply_upiu; |
| 172 |
io_hdr_v4.max_response_len = reply_len; |
| 173 |
io_hdr_v4.request_len = request_len; |
| 174 |
io_hdr_v4.request = (__u64)request_upiu; |
| 175 |
if (dir == SG_DXFER_TO_DEV) { |
| 176 |
io_hdr_v4.dout_xfer_len = (uint32_t)byte_cnt; |
| 177 |
io_hdr_v4.dout_xferp = (uintptr_t)(__u64)buff; |
| 178 |
} else { |
| 179 |
io_hdr_v4.din_xfer_len = (uint32_t)byte_cnt; |
| 180 |
io_hdr_v4.din_xferp = (uintptr_t)(__u64)buff; |
| 181 |
} |
| 182 |
|
| 183 |
If you wish to read or write a descriptor, use the appropriate xferp of |
| 184 |
sg_io_v4. |
| 185 |
|
| 186 |
The userspace tool that interacts with the ufs-bsg endpoint and uses its |
| 187 |
UPIU-based protocol is available at: |
| 188 |
|
| 189 |
https://github.com/westerndigitalcorporation/ufs-tool |
| 190 |
|
| 191 |
For more detailed information about the tool and its supported |
| 192 |
features, please see the tool's README. |
| 193 |
|
| 194 |
UFS specifications can be found at: |
| 195 |
|
| 196 |
- UFS - http://www.jedec.org/sites/default/files/docs/JESD220.pdf |
| 197 |
- UFSHCI - http://www.jedec.org/sites/default/files/docs/JESD223.pdf |
| 198 |
|
| 199 |
5. UFS Reference Clock Frequency configuration |
| 200 |
============================================== |
| 201 |
|
| 202 |
Devicetree can define a clock named "ref_clk" under the UFS controller node |
| 203 |
to specify the intended reference clock frequency for the UFS storage |
| 204 |
parts. ACPI-based system can specify the frequency using ACPI |
| 205 |
Device-Specific Data property named "ref-clk-freq". In both ways the value |
| 206 |
is interpreted as frequency in Hz and must match one of the values given in |
| 207 |
the UFS specification. UFS subsystem will attempt to read the value when |
| 208 |
executing common controller initialization. If the value is available, UFS |
| 209 |
subsystem will ensure the bRefClkFreq attribute of the UFS storage device is |
| 210 |
set accordingly and will modify it if there is a mismatch. |