BusLogic, Inc. designed and manufactured a variety of high performance SCSI |
| 28 |
host adapters which share a common programming interface across a diverse |
| 29 |
collection of bus architectures by virtue of their MultiMaster ASIC technology. |
| 30 |
BusLogic was acquired by Mylex Corporation in February 1996, but the products |
| 31 |
supported by this driver originated under the BusLogic name and so that name is |
| 32 |
retained in the source code and documentation. |
| 33 |
|
| 34 |
This driver supports all present BusLogic MultiMaster Host Adapters, and should |
| 35 |
support any future MultiMaster designs with little or no modification. More |
| 36 |
recently, BusLogic introduced the FlashPoint Host Adapters, which are less |
| 37 |
costly and rely on the host CPU, rather than including an onboard processor. |
| 38 |
Despite not having an onboard CPU, the FlashPoint Host Adapters perform very |
| 39 |
well and have very low command latency. BusLogic has recently provided me with |
| 40 |
the FlashPoint Driver Developer's Kit, which comprises documentation and freely |
| 41 |
redistributable source code for the FlashPoint SCCB Manager. The SCCB Manager |
| 42 |
is the library of code that runs on the host CPU and performs functions |
| 43 |
analogous to the firmware on the MultiMaster Host Adapters. Thanks to their |
| 44 |
having provided the SCCB Manager, this driver now supports the FlashPoint Host |
| 45 |
Adapters as well. |
| 46 |
|
| 47 |
My primary goals in writing this completely new BusLogic driver for Linux are |
| 48 |
to achieve the full performance that BusLogic SCSI Host Adapters and modern |
| 49 |
SCSI peripherals are capable of, and to provide a highly robust driver that can |
| 50 |
be depended upon for high performance mission critical applications. All of |
| 51 |
the major performance features can be configured from the Linux kernel command |
| 52 |
line or at module initialization time, allowing individual installations to |
| 53 |
tune driver performance and error recovery to their particular needs. |
| 54 |
|
| 55 |
The latest information on Linux support for BusLogic SCSI Host Adapters, as |
| 56 |
well as the most recent release of this driver and the latest firmware for the |
| 57 |
BT-948/958/958D, will always be available from my Linux Home Page at URL |
| 58 |
"http://sourceforge.net/projects/dandelion/". |
| 59 |
|
| 60 |
Bug reports should be sent via electronic mail to "[email protected]". Please |
| 61 |
include with the bug report the complete configuration messages reported by the |
| 62 |
driver and SCSI subsystem at startup, along with any subsequent system messages |
| 63 |
relevant to SCSI operations, and a detailed description of your system's |
| 64 |
hardware configuration. |
| 65 |
|
| 66 |
Mylex has been an excellent company to work with and I highly recommend their |
| 67 |
products to the Linux community. In November 1995, I was offered the |
| 68 |
opportunity to become a beta test site for their latest MultiMaster product, |
| 69 |
the BT-948 PCI Ultra SCSI Host Adapter, and then again for the BT-958 PCI Wide |
| 70 |
Ultra SCSI Host Adapter in January 1996. This was mutually beneficial since |
| 71 |
Mylex received a degree and kind of testing that their own testing group cannot |
| 72 |
readily achieve, and the Linux community has available high performance host |
| 73 |
adapters that have been well tested with Linux even before being brought to |
| 74 |
market. This relationship has also given me the opportunity to interact |
| 75 |
directly with their technical staff, to understand more about the internal |
| 76 |
workings of their products, and in turn to educate them about the needs and |
| 77 |
potential of the Linux community. |
| 78 |
|
| 79 |
More recently, Mylex has reaffirmed the company's interest in supporting the |
| 80 |
Linux community, and I am now working on a Linux driver for the DAC960 PCI RAID |
| 81 |
Controllers. Mylex's interest and support is greatly appreciated. |
| 82 |
|
| 83 |
Unlike some other vendors, if you contact Mylex Technical Support with a |
| 84 |
problem and are running Linux, they will not tell you that your use of their |
| 85 |
products is unsupported. Their latest product marketing literature even states |
| 86 |
"Mylex SCSI host adapters are compatible with all major operating systems |
| 87 |
including: ... Linux ...". |
| 88 |
|
| 89 |
Mylex Corporation is located at 34551 Ardenwood Blvd., Fremont, California |
| 90 |
94555, USA and can be reached at 510/796-6100 or on the World Wide Web at |
| 91 |
http://www.mylex.com. Mylex HBA Technical Support can be reached by electronic |
| 92 |
mail at [email protected], by Voice at 510/608-2400, or by FAX at 510/745-7715. |
| 93 |
Contact information for offices in Europe and Japan is available on the Web |
| 94 |
site. |
| 95 |
|
| 96 |
|
| 97 |
Driver Features |
| 98 |
=============== |
| 99 |
|
| 100 |
Configuration Reporting and Testing |
| 101 |
----------------------------------- |
| 102 |
|
| 103 |
During system initialization, the driver reports extensively on the host |
| 104 |
adapter hardware configuration, including the synchronous transfer parameters |
| 105 |
requested and negotiated with each target device. AutoSCSI settings for |
| 106 |
Synchronous Negotiation, Wide Negotiation, and Disconnect/Reconnect are |
| 107 |
reported for each target device, as well as the status of Tagged Queuing. |
| 108 |
If the same setting is in effect for all target devices, then a single word |
| 109 |
or phrase is used; otherwise, a letter is provided for each target device to |
| 110 |
indicate the individual status. The following examples |
| 111 |
should clarify this reporting format: |
| 112 |
|
| 113 |
Synchronous Negotiation: Ultra |
| 114 |
|
| 115 |
Synchronous negotiation is enabled for all target devices and the host |
| 116 |
adapter will attempt to negotiate for 20.0 mega-transfers/second. |
| 117 |
|
| 118 |
Synchronous Negotiation: Fast |
| 119 |
|
| 120 |
Synchronous negotiation is enabled for all target devices and the host |
| 121 |
adapter will attempt to negotiate for 10.0 mega-transfers/second. |
| 122 |
|
| 123 |
Synchronous Negotiation: Slow |
| 124 |
|
| 125 |
Synchronous negotiation is enabled for all target devices and the host |
| 126 |
adapter will attempt to negotiate for 5.0 mega-transfers/second. |
| 127 |
|
| 128 |
Synchronous Negotiation: Disabled |
| 129 |
|
| 130 |
Synchronous negotiation is disabled and all target devices are limited to |
| 131 |
asynchronous operation. |
| 132 |
|
| 133 |
Synchronous Negotiation: UFSNUUU#UUUUUUUU |
| 134 |
|
| 135 |
Synchronous negotiation to Ultra speed is enabled for target devices 0 |
| 136 |
and 4 through 15, to Fast speed for target device 1, to Slow speed for |
| 137 |
target device 2, and is not permitted to target device 3. The host |
| 138 |
adapter's SCSI ID is represented by the "#". |
| 139 |
|
| 140 |
The status of Wide Negotiation, Disconnect/Reconnect, and Tagged Queuing |
| 141 |
are reported as "Enabled", Disabled", or a sequence of "Y" and "N" letters. |
| 142 |
|
| 143 |
Performance Features |
| 144 |
-------------------- |
| 145 |
|
| 146 |
BusLogic SCSI Host Adapters directly implement SCSI-2 Tagged Queuing, and so |
| 147 |
support has been included in the driver to utilize tagged queuing with any |
| 148 |
target devices that report having the tagged queuing capability. Tagged |
| 149 |
queuing allows for multiple outstanding commands to be issued to each target |
| 150 |
device or logical unit, and can improve I/O performance substantially. In |
| 151 |
addition, BusLogic's Strict Round Robin Mode is used to optimize host adapter |
| 152 |
performance, and scatter/gather I/O can support as many segments as can be |
| 153 |
effectively utilized by the Linux I/O subsystem. Control over the use of |
| 154 |
tagged queuing for each target device as well as individual selection of the |
| 155 |
tagged queue depth is available through driver options provided on the kernel |
| 156 |
command line or at module initialization time. By default, the queue depth |
| 157 |
is determined automatically based on the host adapter's total queue depth and |
| 158 |
the number, type, speed, and capabilities of the target devices found. In |
| 159 |
addition, tagged queuing is automatically disabled whenever the host adapter |
| 160 |
firmware version is known not to implement it correctly, or whenever a tagged |
| 161 |
queue depth of 1 is selected. Tagged queuing is also disabled for individual |
| 162 |
target devices if disconnect/reconnect is disabled for that device. |
| 163 |
|
| 164 |
Robustness Features |
| 165 |
------------------- |
| 166 |
|
| 167 |
The driver implements extensive error recovery procedures. When the higher |
| 168 |
level parts of the SCSI subsystem request that a timed out command be reset, |
| 169 |
a selection is made between a full host adapter hard reset and SCSI bus reset |
| 170 |
versus sending a bus device reset message to the individual target device |
| 171 |
based on the recommendation of the SCSI subsystem. Error recovery strategies |
| 172 |
are selectable through driver options individually for each target device, |
| 173 |
and also include sending a bus device reset to the specific target device |
| 174 |
associated with the command being reset, as well as suppressing error |
| 175 |
recovery entirely to avoid perturbing an improperly functioning device. If |
| 176 |
the bus device reset error recovery strategy is selected and sending a bus |
| 177 |
device reset does not restore correct operation, the next command that is |
| 178 |
reset will force a full host adapter hard reset and SCSI bus reset. SCSI bus |
| 179 |
resets caused by other devices and detected by the host adapter are also |
| 180 |
handled by issuing a soft reset to the host adapter and re-initialization. |
| 181 |
Finally, if tagged queuing is active and more than one command reset occurs |
| 182 |
in a 10 minute interval, or if a command reset occurs within the first 10 |
| 183 |
minutes of operation, then tagged queuing will be disabled for that target |
| 184 |
device. These error recovery options improve overall system robustness by |
| 185 |
preventing individual errant devices from causing the system as a whole to |
| 186 |
lock up or crash, and thereby allowing a clean shutdown and restart after the |
| 187 |
offending component is removed. |
| 188 |
|
| 189 |
PCI Configuration Support |
| 190 |
------------------------- |
| 191 |
|
| 192 |
On PCI systems running kernels compiled with PCI BIOS support enabled, this |
| 193 |
driver will interrogate the PCI configuration space and use the I/O port |
| 194 |
addresses assigned by the system BIOS, rather than the ISA compatible I/O |
| 195 |
port addresses. The ISA compatible I/O port address is then disabled by the |
| 196 |
driver. On PCI systems it is also recommended that the AutoSCSI utility be |
| 197 |
used to disable the ISA compatible I/O port entirely as it is not necessary. |
| 198 |
The ISA compatible I/O port is disabled by default on the BT-948/958/958D. |
| 199 |
|
| 200 |
/proc File System Support |
| 201 |
------------------------- |
| 202 |
|
| 203 |
Copies of the host adapter configuration information together with updated |
| 204 |
data transfer and error recovery statistics are available through the |
| 205 |
/proc/scsi/BusLogic/<N> interface. |
| 206 |
|
| 207 |
Shared Interrupts Support |
| 208 |
------------------------- |
| 209 |
|
| 210 |
On systems that support shared interrupts, any number of BusLogic Host |
| 211 |
Adapters may share the same interrupt request channel. |
| 212 |
|
| 213 |
|
| 214 |
Supported Host Adapters |
| 215 |
======================= |
| 216 |
|
| 217 |
The following list comprises the supported BusLogic SCSI Host Adapters as of |
| 218 |
the date of this document. It is recommended that anyone purchasing a BusLogic |
| 219 |
Host Adapter not in the following table contact the author beforehand to verify |
| 220 |
that it is or will be supported. |
| 221 |
|
| 222 |
FlashPoint Series PCI Host Adapters: |
| 223 |
|
| 224 |
======================= ============================================= |
| 225 |
FlashPoint LT (BT-930) Ultra SCSI-3 |
| 226 |
FlashPoint LT (BT-930R) Ultra SCSI-3 with RAIDPlus |
| 227 |
FlashPoint LT (BT-920) Ultra SCSI-3 (BT-930 without BIOS) |
| 228 |
FlashPoint DL (BT-932) Dual Channel Ultra SCSI-3 |
| 229 |
FlashPoint DL (BT-932R) Dual Channel Ultra SCSI-3 with RAIDPlus |
| 230 |
FlashPoint LW (BT-950) Wide Ultra SCSI-3 |
| 231 |
FlashPoint LW (BT-950R) Wide Ultra SCSI-3 with RAIDPlus |
| 232 |
FlashPoint DW (BT-952) Dual Channel Wide Ultra SCSI-3 |
| 233 |
FlashPoint DW (BT-952R) Dual Channel Wide Ultra SCSI-3 with RAIDPlus |
| 234 |
======================= ============================================= |
| 235 |
|
| 236 |
MultiMaster "W" Series Host Adapters: |
| 237 |
|
| 238 |
======= === ============================== |
| 239 |
BT-948 PCI Ultra SCSI-3 |
| 240 |
BT-958 PCI Wide Ultra SCSI-3 |
| 241 |
BT-958D PCI Wide Differential Ultra SCSI-3 |
| 242 |
======= === ============================== |
| 243 |
|
| 244 |
MultiMaster "C" Series Host Adapters: |
| 245 |
|
| 246 |
======== ==== ============================== |
| 247 |
BT-946C PCI Fast SCSI-2 |
| 248 |
BT-956C PCI Wide Fast SCSI-2 |
| 249 |
BT-956CD PCI Wide Differential Fast SCSI-2 |
| 250 |
BT-445C VLB Fast SCSI-2 |
| 251 |
BT-747C EISA Fast SCSI-2 |
| 252 |
BT-757C EISA Wide Fast SCSI-2 |
| 253 |
BT-757CD EISA Wide Differential Fast SCSI-2 |
| 254 |
======== ==== ============================== |
| 255 |
|
| 256 |
MultiMaster "S" Series Host Adapters: |
| 257 |
|
| 258 |
======= ==== ============================== |
| 259 |
BT-445S VLB Fast SCSI-2 |
| 260 |
BT-747S EISA Fast SCSI-2 |
| 261 |
BT-747D EISA Differential Fast SCSI-2 |
| 262 |
BT-757S EISA Wide Fast SCSI-2 |
| 263 |
BT-757D EISA Wide Differential Fast SCSI-2 |
| 264 |
BT-742A EISA SCSI-2 (742A revision H) |
| 265 |
======= ==== ============================== |
| 266 |
|
| 267 |
MultiMaster "A" Series Host Adapters: |
| 268 |
|
| 269 |
======= ==== ============================== |
| 270 |
BT-742A EISA SCSI-2 (742A revisions A - G) |
| 271 |
======= ==== ============================== |
| 272 |
|
| 273 |
AMI FastDisk Host Adapters that are true BusLogic MultiMaster clones are also |
| 274 |
supported by this driver. |
| 275 |
|
| 276 |
BusLogic SCSI Host Adapters are available packaged both as bare boards and as |
| 277 |
retail kits. The BT- model numbers above refer to the bare board packaging. |
| 278 |
The retail kit model numbers are found by replacing BT- with KT- in the above |
| 279 |
list. The retail kit includes the bare board and manual as well as cabling and |
| 280 |
driver media and documentation that are not provided with bare boards. |
| 281 |
|
| 282 |
|
| 283 |
FlashPoint Installation Notes |
| 284 |
============================= |
| 285 |
|
| 286 |
RAIDPlus Support |
| 287 |
---------------- |
| 288 |
|
| 289 |
FlashPoint Host Adapters now include RAIDPlus, Mylex's bootable software |
| 290 |
RAID. RAIDPlus is not supported on Linux, and there are no plans to support |
| 291 |
it. The MD driver in Linux 2.0 provides for concatenation (LINEAR) and |
| 292 |
striping (RAID-0), and support for mirroring (RAID-1), fixed parity (RAID-4), |
| 293 |
and distributed parity (RAID-5) is available separately. The built-in Linux |
| 294 |
RAID support is generally more flexible and is expected to perform better |
| 295 |
than RAIDPlus, so there is little impetus to include RAIDPlus support in the |
| 296 |
BusLogic driver. |
| 297 |
|
| 298 |
Enabling UltraSCSI Transfers |
| 299 |
---------------------------- |
| 300 |
|
| 301 |
FlashPoint Host Adapters ship with their configuration set to "Factory |
| 302 |
Default" settings that are conservative and do not allow for UltraSCSI speed |
| 303 |
to be negotiated. This results in fewer problems when these host adapters |
| 304 |
are installed in systems with cabling or termination that is not sufficient |
| 305 |
for UltraSCSI operation, or where existing SCSI devices do not properly |
| 306 |
respond to synchronous transfer negotiation for UltraSCSI speed. AutoSCSI |
| 307 |
may be used to load "Optimum Performance" settings which allow UltraSCSI |
| 308 |
speed to be negotiated with all devices, or UltraSCSI speed can be enabled on |
| 309 |
an individual basis. It is recommended that SCAM be manually disabled after |
| 310 |
the "Optimum Performance" settings are loaded. |
| 311 |
|
| 312 |
|
| 313 |
BT-948/958/958D Installation Notes |
| 314 |
================================== |
| 315 |
|
| 316 |
The BT-948/958/958D PCI Ultra SCSI Host Adapters have some features which may |
| 317 |
require attention in some circumstances when installing Linux. |
| 318 |
|
| 319 |
PCI I/O Port Assignments |
| 320 |
------------------------ |
| 321 |
|
| 322 |
When configured to factory default settings, the BT-948/958/958D will only |
| 323 |
recognize the PCI I/O port assignments made by the motherboard's PCI BIOS. |
| 324 |
The BT-948/958/958D will not respond to any of the ISA compatible I/O ports |
| 325 |
that previous BusLogic SCSI Host Adapters respond to. This driver supports |
| 326 |
the PCI I/O port assignments, so this is the preferred configuration. |
| 327 |
However, if the obsolete BusLogic driver must be used for any reason, such as |
| 328 |
a Linux distribution that does not yet use this driver in its boot kernel, |
| 329 |
BusLogic has provided an AutoSCSI configuration option to enable a legacy ISA |
| 330 |
compatible I/O port. |
| 331 |
|
| 332 |
To enable this backward compatibility option, invoke the AutoSCSI utility via |
| 333 |
Ctrl-B at system startup and select "Adapter Configuration", "View/Modify |
| 334 |
Configuration", and then change the "ISA Compatible Port" setting from |
| 335 |
"Disable" to "Primary" or "Alternate". Once this driver has been installed, |
| 336 |
the "ISA Compatible Port" option should be set back to "Disable" to avoid |
| 337 |
possible future I/O port conflicts. The older BT-946C/956C/956CD also have |
| 338 |
this configuration option, but the factory default setting is "Primary". |
| 339 |
|
| 340 |
PCI Slot Scanning Order |
| 341 |
----------------------- |
| 342 |
|
| 343 |
In systems with multiple BusLogic PCI Host Adapters, the order in which the |
| 344 |
PCI slots are scanned may appear reversed with the BT-948/958/958D as |
| 345 |
compared to the BT-946C/956C/956CD. For booting from a SCSI disk to work |
| 346 |
correctly, it is necessary that the host adapter's BIOS and the kernel agree |
| 347 |
on which disk is the boot device, which requires that they recognize the PCI |
| 348 |
host adapters in the same order. The motherboard's PCI BIOS provides a |
| 349 |
standard way of enumerating the PCI host adapters, which is used by the Linux |
| 350 |
kernel. Some PCI BIOS implementations enumerate the PCI slots in order of |
| 351 |
increasing bus number and device number, while others do so in the opposite |
| 352 |
direction. |
| 353 |
|
| 354 |
Unfortunately, Microsoft decided that Windows 95 would always enumerate the |
| 355 |
PCI slots in order of increasing bus number and device number regardless of |
| 356 |
the PCI BIOS enumeration, and requires that their scheme be supported by the |
| 357 |
host adapter's BIOS to receive Windows 95 certification. Therefore, the |
| 358 |
factory default settings of the BT-948/958/958D enumerate the host adapters |
| 359 |
by increasing bus number and device number. To disable this feature, invoke |
| 360 |
the AutoSCSI utility via Ctrl-B at system startup and select "Adapter |
| 361 |
Configuration", "View/Modify Configuration", press Ctrl-F10, and then change |
| 362 |
the "Use Bus And Device # For PCI Scanning Seq." option to OFF. |
| 363 |
|
| 364 |
This driver will interrogate the setting of the PCI Scanning Sequence option |
| 365 |
so as to recognize the host adapters in the same order as they are enumerated |
| 366 |
by the host adapter's BIOS. |
| 367 |
|
| 368 |
Enabling UltraSCSI Transfers |
| 369 |
---------------------------- |
| 370 |
|
| 371 |
The BT-948/958/958D ship with their configuration set to "Factory Default" |
| 372 |
settings that are conservative and do not allow for UltraSCSI speed to be |
| 373 |
negotiated. This results in fewer problems when these host adapters are |
| 374 |
installed in systems with cabling or termination that is not sufficient for |
| 375 |
UltraSCSI operation, or where existing SCSI devices do not properly respond |
| 376 |
to synchronous transfer negotiation for UltraSCSI speed. AutoSCSI may be |
| 377 |
used to load "Optimum Performance" settings which allow UltraSCSI speed to be |
| 378 |
negotiated with all devices, or UltraSCSI speed can be enabled on an |
| 379 |
individual basis. It is recommended that SCAM be manually disabled after the |
| 380 |
"Optimum Performance" settings are loaded. |
| 381 |
|
| 382 |
|
| 383 |
Driver Options |
| 384 |
============== |
| 385 |
|
| 386 |
BusLogic Driver Options may be specified either via the Linux Kernel Command |
| 387 |
Line or via the Loadable Kernel Module Installation Facility. Driver Options |
| 388 |
for multiple host adapters may be specified either by separating the option |
| 389 |
strings by a semicolon, or by specifying multiple "BusLogic=" strings on the |
| 390 |
command line. Individual option specifications for a single host adapter are |
| 391 |
separated by commas. The Probing and Debugging Options apply to all host |
| 392 |
adapters whereas the remaining options apply individually only to the |
| 393 |
selected host adapter. |
| 394 |
|
| 395 |
The BusLogic Driver Probing Options comprise the following: |
| 396 |
|
| 397 |
NoProbe |
| 398 |
|
| 399 |
The "NoProbe" option disables all probing and therefore no BusLogic Host |
| 400 |
Adapters will be detected. |
| 401 |
|
| 402 |
NoProbePCI |
| 403 |
|
| 404 |
The "NoProbePCI" options disables the interrogation of PCI Configuration |
| 405 |
Space and therefore only ISA Multimaster Host Adapters will be detected, as |
| 406 |
well as PCI Multimaster Host Adapters that have their ISA Compatible I/O |
| 407 |
Port set to "Primary" or "Alternate". |
| 408 |
|
| 409 |
NoSortPCI |
| 410 |
|
| 411 |
The "NoSortPCI" option forces PCI MultiMaster Host Adapters to be |
| 412 |
enumerated in the order provided by the PCI BIOS, ignoring any setting of |
| 413 |
the AutoSCSI "Use Bus And Device # For PCI Scanning Seq." option. |
| 414 |
|
| 415 |
MultiMasterFirst |
| 416 |
|
| 417 |
The "MultiMasterFirst" option forces MultiMaster Host Adapters to be probed |
| 418 |
before FlashPoint Host Adapters. By default, if both FlashPoint and PCI |
| 419 |
MultiMaster Host Adapters are present, this driver will probe for |
| 420 |
FlashPoint Host Adapters first unless the BIOS primary disk is controlled |
| 421 |
by the first PCI MultiMaster Host Adapter, in which case MultiMaster Host |
| 422 |
Adapters will be probed first. |
| 423 |
|
| 424 |
FlashPointFirst |
| 425 |
|
| 426 |
The "FlashPointFirst" option forces FlashPoint Host Adapters to be probed |
| 427 |
before MultiMaster Host Adapters. |
| 428 |
|
| 429 |
The BusLogic Driver Tagged Queuing Options allow for explicitly specifying |
| 430 |
the Queue Depth and whether Tagged Queuing is permitted for each Target |
| 431 |
Device (assuming that the Target Device supports Tagged Queuing). The Queue |
| 432 |
Depth is the number of SCSI Commands that are allowed to be concurrently |
| 433 |
presented for execution (either to the Host Adapter or Target Device). Note |
| 434 |
that explicitly enabling Tagged Queuing may lead to problems; the option to |
| 435 |
enable or disable Tagged Queuing is provided primarily to allow disabling |
| 436 |
Tagged Queuing on Target Devices that do not implement it correctly. The |
| 437 |
following options are available: |
| 438 |
|
| 439 |
QueueDepth:<integer> |
| 440 |
|
| 441 |
The "QueueDepth:" or QD:" option specifies the Queue Depth to use for all |
| 442 |
Target Devices that support Tagged Queuing, as well as the maximum Queue |
| 443 |
Depth for devices that do not support Tagged Queuing. If no Queue Depth |
| 444 |
option is provided, the Queue Depth will be determined automatically based |
| 445 |
on the Host Adapter's Total Queue Depth and the number, type, speed, and |
| 446 |
capabilities of the detected Target Devices. Target Devices that |
| 447 |
do not support Tagged Queuing always have their Queue Depth set to |
| 448 |
BusLogic_UntaggedQueueDepth or BusLogic_UntaggedQueueDepthBB, unless a |
| 449 |
lower Queue Depth option is provided. A Queue Depth of 1 automatically |
| 450 |
disables Tagged Queuing. |
| 451 |
|
| 452 |
QueueDepth:[<integer>,<integer>...] |
| 453 |
|
| 454 |
The "QueueDepth:[...]" or "QD:[...]" option specifies the Queue Depth |
| 455 |
individually for each Target Device. If an <integer> is omitted, the |
| 456 |
associated Target Device will have its Queue Depth selected automatically. |
| 457 |
|
| 458 |
TaggedQueuing:Default |
| 459 |
|
| 460 |
The "TaggedQueuing:Default" or "TQ:Default" option permits Tagged Queuing |
| 461 |
based on the firmware version of the BusLogic Host Adapter and based on |
| 462 |
whether the Queue Depth allows queuing multiple commands. |
| 463 |
|
| 464 |
TaggedQueuing:Enable |
| 465 |
|
| 466 |
The "TaggedQueuing:Enable" or "TQ:Enable" option enables Tagged Queuing for |
| 467 |
all Target Devices on this Host Adapter, overriding any limitation that |
| 468 |
would otherwise be imposed based on the Host Adapter firmware version. |
| 469 |
|
| 470 |
TaggedQueuing:Disable |
| 471 |
|
| 472 |
The "TaggedQueuing:Disable" or "TQ:Disable" option disables Tagged Queuing |
| 473 |
for all Target Devices on this Host Adapter. |
| 474 |
|
| 475 |
TaggedQueuing:<Target-Spec> |
| 476 |
|
| 477 |
The "TaggedQueuing:<Target-Spec>" or "TQ:<Target-Spec>" option controls |
| 478 |
Tagged Queuing individually for each Target Device. <Target-Spec> is a |
| 479 |
sequence of "Y", "N", and "X" characters. "Y" enables Tagged Queuing, "N" |
| 480 |
disables Tagged Queuing, and "X" accepts the default based on the firmware |
| 481 |
version. The first character refers to Target Device 0, the second to |
| 482 |
Target Device 1, and so on; if the sequence of "Y", "N", and "X" characters |
| 483 |
does not cover all the Target Devices, unspecified characters are assumed |
| 484 |
to be "X". |
| 485 |
|
| 486 |
The BusLogic Driver Miscellaneous Options comprise the following: |
| 487 |
|
| 488 |
BusSettleTime:<seconds> |
| 489 |
|
| 490 |
The "BusSettleTime:" or "BST:" option specifies the Bus Settle Time in |
| 491 |
seconds. The Bus Settle Time is the amount of time to wait between a Host |
| 492 |
Adapter Hard Reset which initiates a SCSI Bus Reset and issuing any SCSI |
| 493 |
Commands. If unspecified, it defaults to BusLogic_DefaultBusSettleTime. |
| 494 |
|
| 495 |
InhibitTargetInquiry |
| 496 |
|
| 497 |
The "InhibitTargetInquiry" option inhibits the execution of an Inquire |
| 498 |
Target Devices or Inquire Installed Devices command on MultiMaster Host |
| 499 |
Adapters. This may be necessary with some older Target Devices that do not |
| 500 |
respond correctly when Logical Units above 0 are addressed. |
| 501 |
|
| 502 |
The BusLogic Driver Debugging Options comprise the following: |
| 503 |
|
| 504 |
TraceProbe |
| 505 |
|
| 506 |
The "TraceProbe" option enables tracing of Host Adapter Probing. |
| 507 |
|
| 508 |
TraceHardwareReset |
| 509 |
|
| 510 |
The "TraceHardwareReset" option enables tracing of Host Adapter Hardware |
| 511 |
Reset. |
| 512 |
|
| 513 |
TraceConfiguration |
| 514 |
|
| 515 |
The "TraceConfiguration" option enables tracing of Host Adapter |
| 516 |
Configuration. |
| 517 |
|
| 518 |
TraceErrors |
| 519 |
|
| 520 |
The "TraceErrors" option enables tracing of SCSI Commands that return an |
| 521 |
error from the Target Device. The CDB and Sense Data will be printed for |
| 522 |
each SCSI Command that fails. |
| 523 |
|
| 524 |
Debug |
| 525 |
|
| 526 |
The "Debug" option enables all debugging options. |
| 527 |
|
| 528 |
The following examples demonstrate setting the Queue Depth for Target Devices |
| 529 |
1 and 2 on the first host adapter to 7 and 15, the Queue Depth for all Target |
| 530 |
Devices on the second host adapter to 31, and the Bus Settle Time on the |
| 531 |
second host adapter to 30 seconds. |
| 532 |
|
| 533 |
Linux Kernel Command Line:: |
| 534 |
|
| 535 |
linux BusLogic=QueueDepth:[,7,15];QueueDepth:31,BusSettleTime:30 |
| 536 |
|
| 537 |
LILO Linux Boot Loader (in /etc/lilo.conf):: |
| 538 |
|
| 539 |
append = "BusLogic=QueueDepth:[,7,15];QueueDepth:31,BusSettleTime:30" |
| 540 |
|
| 541 |
INSMOD Loadable Kernel Module Installation Facility:: |
| 542 |
|
| 543 |
insmod BusLogic.o \ |
| 544 |
'BusLogic="QueueDepth:[,7,15];QueueDepth:31,BusSettleTime:30"' |
| 545 |
|
| 546 |
|
| 547 |
.. Note:: |
| 548 |
|
| 549 |
Module Utilities 2.1.71 or later is required for correct parsing |
| 550 |
of driver options containing commas. |
| 551 |
|
| 552 |
|
| 553 |
Driver Installation |
| 554 |
=================== |
| 555 |
|
| 556 |
This distribution was prepared for Linux kernel version 2.0.35, but should be |
| 557 |
compatible with 2.0.4 or any later 2.0 series kernel. |
| 558 |
|
| 559 |
To install the new BusLogic SCSI driver, you may use the following commands, |
| 560 |
replacing "/usr/src" with wherever you keep your Linux kernel source tree:: |
| 561 |
|
| 562 |
cd /usr/src |
| 563 |
tar -xvzf BusLogic-2.0.15.tar.gz |
| 564 |
mv README.* LICENSE.* BusLogic.[ch] FlashPoint.c linux/drivers/scsi |
| 565 |
patch -p0 < BusLogic.patch (only for 2.0.33 and below) |
| 566 |
cd linux |
| 567 |
make config |
| 568 |
make zImage |
| 569 |
|
| 570 |
Then install "arch/x86/boot/zImage" as your standard kernel, run lilo if |
| 571 |
appropriate, and reboot. |
| 572 |
|
| 573 |
|
| 574 |
BusLogic Announcements Mailing List |
| 575 |
=================================== |
| 576 |
|
| 577 |
The BusLogic Announcements Mailing List provides a forum for informing Linux |
| 578 |
users of new driver releases and other announcements regarding Linux support |
| 579 |
for BusLogic SCSI Host Adapters. To join the mailing list, send a message to |
| 580 |
"[email protected]" with the line "subscribe" in the |
| 581 |
message body. |