Debian Codegraph @

Documentation/driver-api/thermal/intel_dptf.rst

raw
1 .. SPDX-License-Identifier: GPL-2.0
2
3 ===============================================================
4 Intel(R) Dynamic Platform and Thermal Framework Sysfs Interface
5 ===============================================================
6
7 :Copyright: © 2022 Intel Corporation
8
9 :Author: Srinivas Pandruvada <[email protected]>
10
11 Introduction
12 ------------
13
14 Intel(R) Dynamic Platform and Thermal Framework (DPTF) is a platform
15 level hardware/software solution for power and thermal management.
16
17 As a container for multiple power/thermal technologies, DPTF provides
18 a coordinated approach for different policies to effect the hardware
19 state of a system.
20
21 Since it is a platform level framework, this has several components.
22 Some parts of the technology is implemented in the firmware and uses
23 ACPI and PCI devices to expose various features for monitoring and
24 control. Linux has a set of kernel drivers exposing hardware interface
25 to user space. This allows user space thermal solutions like
26 "Linux Thermal Daemon" to read platform specific thermal and power
27 tables to deliver adequate performance while keeping the system under
28 thermal limits.
29
30 DPTF ACPI Drivers interface
31 ----------------------------
32
33 :file:`/sys/bus/platform/devices/<N>/uuids`, where <N>
34 =INT3400|INTC1040|INTC1041|INTC10A0
35
36 ``available_uuids`` (RO)
37 A set of UUIDs strings presenting available policies
38 which should be notified to the firmware when the
39 user space can support those policies.
40
41 UUID strings:
42
43 "42A441D6-AE6A-462b-A84B-4A8CE79027D3" : Passive 1
44
45 "3A95C389-E4B8-4629-A526-C52C88626BAE" : Active
46
47 "97C68AE7-15FA-499c-B8C9-5DA81D606E0A" : Critical
48
49 "63BE270F-1C11-48FD-A6F7-3AF253FF3E2D" : Adaptive performance
50
51 "5349962F-71E6-431D-9AE8-0A635B710AEE" : Emergency call
52
53 "9E04115A-AE87-4D1C-9500-0F3E340BFE75" : Passive 2
54
55 "F5A35014-C209-46A4-993A-EB56DE7530A1" : Power Boss
56
57 "6ED722A7-9240-48A5-B479-31EEF723D7CF" : Virtual Sensor
58
59 "16CAF1B7-DD38-40ED-B1C1-1B8A1913D531" : Cooling mode
60
61 "BE84BABF-C4D4-403D-B495-3128FD44dAC1" : HDC
62
63 ``current_uuid`` (RW)
64 User space can write strings from available UUIDs, one at a
65 time.
66
67 :file:`/sys/bus/platform/devices/<N>/`, where <N>
68 =INT3400|INTC1040|INTC1041|INTC10A0
69
70 ``imok`` (WO)
71 User space daemon write 1 to respond to firmware event
72 for sending keep alive notification. User space receives
73 THERMAL_EVENT_KEEP_ALIVE kobject uevent notification when
74 firmware calls for user space to respond with imok ACPI
75 method.
76
77 ``odvp*`` (RO)
78 Firmware thermal status variable values. Thermal tables
79 calls for different processing based on these variable
80 values.
81
82 ``data_vault`` (RO)
83 Binary thermal table. Refer to
84 https:/github.com/intel/thermal_daemon for decoding
85 thermal table.
86
87 ``production_mode`` (RO)
88 When different from zero, manufacturer locked thermal configuration
89 from further changes.
90
91 ACPI Thermal Relationship table interface
92 ------------------------------------------
93
94 :file:`/dev/acpi_thermal_rel`
95
96 This device provides IOCTL interface to read standard ACPI
97 thermal relationship tables via ACPI methods _TRT and _ART.
98 These IOCTLs are defined in
99 drivers/thermal/intel/int340x_thermal/acpi_thermal_rel.h
100
101 IOCTLs:
102
103 ACPI_THERMAL_GET_TRT_LEN: Get length of TRT table
104
105 ACPI_THERMAL_GET_ART_LEN: Get length of ART table
106
107 ACPI_THERMAL_GET_TRT_COUNT: Number of records in TRT table
108
109 ACPI_THERMAL_GET_ART_COUNT: Number of records in ART table
110
111 ACPI_THERMAL_GET_TRT: Read binary TRT table, length to read is
112 provided via argument to ioctl().
113
114 ACPI_THERMAL_GET_ART: Read binary ART table, length to read is
115 provided via argument to ioctl().
116
117 DPTF ACPI Sensor drivers
118 -------------------------
119
120 DPTF Sensor drivers are presented as standard thermal sysfs thermal_zone.
121
122
123 DPTF ACPI Cooling drivers
124 --------------------------
125
126 DPTF cooling drivers are presented as standard thermal sysfs cooling_device.
127
128
129 DPTF Processor thermal PCI Driver interface
130 --------------------------------------------
131
132 :file:`/sys/bus/pci/devices/0000\:00\:04.0/power_limits/`
133
134 Refer to Documentation/power/powercap/powercap.rst for powercap
135 ABI.
136
137 ``power_limit_0_max_uw`` (RO)
138 Maximum powercap sysfs constraint_0_power_limit_uw for Intel RAPL
139
140 ``power_limit_0_step_uw`` (RO)
141 Power limit increment/decrements for Intel RAPL constraint 0 power limit
142
143 ``power_limit_0_min_uw`` (RO)
144 Minimum powercap sysfs constraint_0_power_limit_uw for Intel RAPL
145
146 ``power_limit_0_tmin_us`` (RO)
147 Minimum powercap sysfs constraint_0_time_window_us for Intel RAPL
148
149 ``power_limit_0_tmax_us`` (RO)
150 Maximum powercap sysfs constraint_0_time_window_us for Intel RAPL
151
152 ``power_limit_1_max_uw`` (RO)
153 Maximum powercap sysfs constraint_1_power_limit_uw for Intel RAPL
154
155 ``power_limit_1_step_uw`` (RO)
156 Power limit increment/decrements for Intel RAPL constraint 1 power limit
157
158 ``power_limit_1_min_uw`` (RO)
159 Minimum powercap sysfs constraint_1_power_limit_uw for Intel RAPL
160
161 ``power_limit_1_tmin_us`` (RO)
162 Minimum powercap sysfs constraint_1_time_window_us for Intel RAPL
163
164 ``power_limit_1_tmax_us`` (RO)
165 Maximum powercap sysfs constraint_1_time_window_us for Intel RAPL
166
167 ``power_floor_status`` (RO)
168 When set to 1, the power floor of the system in the current
169 configuration has been reached. It needs to be reconfigured to allow
170 power to be reduced any further.
171
172 ``power_floor_enable`` (RW)
173 When set to 1, enable reading and notification of the power floor
174 status. Notifications are triggered for the power_floor_status
175 attribute value changes.
176
177 :file:`/sys/bus/pci/devices/0000\:00\:04.0/`
178
179 ``tcc_offset_degree_celsius`` (RW)
180 TCC offset from the critical temperature where hardware will throttle
181 CPU.
182
183 :file:`/sys/bus/pci/devices/0000\:00\:04.0/workload_request`
184
185 ``workload_available_types`` (RO)
186 Available workload types. User space can specify one of the workload type
187 it is currently executing via workload_type. For example: idle, bursty,
188 sustained etc.
189
190 ``workload_type`` (RW)
191 User space can specify any one of the available workload type using
192 this interface.
193
194 :file:`/sys/bus/pci/devices/0000\:00\:04.0/ptc_0_control`
195 :file:`/sys/bus/pci/devices/0000\:00\:04.0/ptc_1_control`
196 :file:`/sys/bus/pci/devices/0000\:00\:04.0/ptc_2_control`
197
198 All these controls needs admin privilege to update.
199
200 ``enable`` (RW)
201 1 for enable, 0 for disable. Shows the current enable status of
202 platform temperature control feature. User space can enable/disable
203 hardware controls.
204
205 ``temperature_target`` (RW)
206 Update a new temperature target in milli degree celsius for hardware to
207 use for the temperature control.
208
209 ``thermal_tolerance`` (RW)
210 This attribute ranges from 0 to 7, where 0 represents
211 the most aggressive control to avoid any temperature overshoots, and
212 7 represents a more graceful approach, favoring performance even at
213 the expense of temperature overshoots.
214 Note: This level may not scale linearly. For example, a value of 3 does
215 not necessarily imply a 50% improvement in performance compared to a
216 value of 0.
217
218 Given that this is platform temperature control, it is expected that a
219 single user-level manager owns and manages the controls. If multiple
220 user-level software applications attempt to write different targets, it
221 can lead to unexpected behavior.
222
223
224 DPTF Processor thermal RFIM interface
225 --------------------------------------------
226
227 RFIM interface allows adjustment of FIVR (Fully Integrated Voltage Regulator),
228 DDR (Double Data Rate) and DLVR (Digital Linear Voltage Regulator)
229 frequencies to avoid RF interference with WiFi and 5G.
230
231 Switching voltage regulators (VR) generate radiated EMI or RFI at the
232 fundamental frequency and its harmonics. Some harmonics may interfere
233 with very sensitive wireless receivers such as Wi-Fi and cellular that
234 are integrated into host systems like notebook PCs. One of mitigation
235 methods is requesting SOC integrated VR (IVR) switching frequency to a
236 small % and shift away the switching noise harmonic interference from
237 radio channels. OEM or ODMs can use the driver to control SOC IVR
238 operation within the range where it does not impact IVR performance.
239
240 Some products use DLVR instead of FIVR as switching voltage regulator.
241 In this case attributes of DLVR must be adjusted instead of FIVR.
242
243 While shifting the frequencies additional clock noise can be introduced,
244 which is compensated by adjusting Spread spectrum percent. This helps
245 to reduce the clock noise to meet regulatory compliance. This spreading
246 % increases bandwidth of signal transmission and hence reduces the
247 effects of interference, noise and signal fading.
248
249 DRAM devices of DDR IO interface and their power plane can generate EMI
250 at the data rates. Similar to IVR control mechanism, Intel offers a
251 mechanism by which DDR data rates can be changed if several conditions
252 are met: there is strong RFI interference because of DDR; CPU power
253 management has no other restriction in changing DDR data rates;
254 PC ODMs enable this feature (real time DDR RFI Mitigation referred to as
255 DDR-RFIM) for Wi-Fi from BIOS.
256
257
258 FIVR attributes
259
260 :file:`/sys/bus/pci/devices/0000\:00\:04.0/fivr/`
261
262 ``vco_ref_code_lo`` (RW)
263 The VCO reference code is an 11-bit field and controls the FIVR
264 switching frequency. This is the 3-bit LSB field.
265
266 ``vco_ref_code_hi`` (RW)
267 The VCO reference code is an 11-bit field and controls the FIVR
268 switching frequency. This is the 8-bit MSB field.
269
270 ``spread_spectrum_pct`` (RW)
271 Set the FIVR spread spectrum clocking percentage
272
273 ``spread_spectrum_clk_enable`` (RW)
274 Enable/disable of the FIVR spread spectrum clocking feature
275
276 ``rfi_vco_ref_code`` (RW)
277 This field is a read only status register which reflects the
278 current FIVR switching frequency
279
280 ``fivr_fffc_rev`` (RW)
281 This field indicated the revision of the FIVR HW.
282
283
284 DVFS attributes
285
286 :file:`/sys/bus/pci/devices/0000\:00\:04.0/dvfs/`
287
288 ``rfi_restriction_run_busy`` (RW)
289 Request the restriction of specific DDR data rate and set this
290 value 1. Self reset to 0 after operation.
291
292 ``rfi_restriction_err_code`` (RW)
293 0 :Request is accepted, 1:Feature disabled,
294 2: the request restricts more points than it is allowed
295
296 ``rfi_restriction_data_rate_Delta`` (RW)
297 Restricted DDR data rate for RFI protection: Lower Limit
298
299 ``rfi_restriction_data_rate_Base`` (RW)
300 Restricted DDR data rate for RFI protection: Upper Limit
301
302 ``ddr_data_rate_point_0`` (RO)
303 DDR data rate selection 1st point
304
305 ``ddr_data_rate_point_1`` (RO)
306 DDR data rate selection 2nd point
307
308 ``ddr_data_rate_point_2`` (RO)
309 DDR data rate selection 3rd point
310
311 ``ddr_data_rate_point_3`` (RO)
312 DDR data rate selection 4th point
313
314 ``rfi_disable (RW)``
315 Disable DDR rate change feature
316
317 DLVR attributes
318
319 :file:`/sys/bus/pci/devices/0000\:00\:04.0/dlvr/`
320
321 ``dlvr_hardware_rev`` (RO)
322 DLVR hardware revision.
323
324 ``dlvr_freq_mhz`` (RO)
325 Current DLVR PLL frequency in MHz.
326
327 ``dlvr_freq_select`` (RW)
328 Sets DLVR PLL clock frequency. Once set, and enabled via
329 dlvr_rfim_enable, the dlvr_freq_mhz will show the current
330 DLVR PLL frequency.
331
332 ``dlvr_pll_busy`` (RO)
333 PLL can't accept frequency change when set.
334
335 ``dlvr_rfim_enable`` (RW)
336 0: Disable RF frequency hopping, 1: Enable RF frequency hopping.
337
338 ``dlvr_spread_spectrum_pct`` (RW)
339 Sets DLVR spread spectrum percent value.
340
341 ``dlvr_control_mode`` (RW)
342 Specifies how frequencies are spread using spread spectrum.
343 0: Down spread,
344 1: Spread in the Center.
345
346 ``dlvr_control_lock`` (RW)
347 1: future writes are ignored.
348
349 DPTF Power supply and Battery Interface
350 ----------------------------------------
351
352 Refer to Documentation/ABI/testing/sysfs-platform-dptf
353
354 DPTF Fan Control
355 ----------------------------------------
356
357 Refer to Documentation/admin-guide/acpi/fan_performance_states.rst
358
359 Workload Type Hints
360 ----------------------------------------
361
362 The firmware in Meteor Lake processor generation is capable of identifying
363 workload type and passing hints regarding it to the OS. A special sysfs
364 interface is provided to allow user space to obtain workload type hints from
365 the firmware and control the rate at which they are provided.
366
367 User space can poll attribute "workload_type_index" for the current hint or
368 can receive a notification whenever the value of this attribute is updated.
369
370 file:`/sys/bus/pci/devices/0000:00:04.0/workload_hint/`
371 Segment 0, bus 0, device 4, function 0 is reserved for the processor thermal
372 device on all Intel client processors. So, the above path doesn't change
373 based on the processor generation.
374
375 ``workload_hint_enable`` (RW)
376 Enable firmware to send workload type hints to user space.
377
378 ``workload_slow_hint_enable`` (RW)
379 Enable firmware to send slow workload type hints to user space.
380
381 ``notification_delay_ms`` (RW)
382 Minimum delay in milliseconds before firmware will notify OS. This is
383 for the rate control of notifications. This delay is between changing
384 the workload type prediction in the firmware and notifying the OS about
385 the change. The default delay is 1024 ms. The delay of 0 is invalid.
386 The delay is rounded up to the nearest power of 2 to simplify firmware
387 programming of the delay value. The read of notification_delay_ms
388 attribute shows the effective value used.
389
390 ``workload_type_index`` (RO)
391 Predicted workload type index. User space can get notification of
392 change via existing sysfs attribute change notification mechanism.
393
394 The supported index values and their meaning for the Meteor Lake
395 processor generation are as follows:
396
397 0 - Idle: System performs no tasks, power and idle residency are
398 consistently low for long periods of time.
399
400 1 – Battery Life: Power is relatively low, but the processor may
401 still be actively performing a task, such as video playback for
402 a long period of time.
403
404 2 – Sustained: Power level that is relatively high for a long period
405 of time, with very few to no periods of idleness, which will
406 eventually exhaust RAPL Power Limit 1 and 2.
407
408 3 – Bursty: Consumes a relatively constant average amount of power, but
409 periods of relative idleness are interrupted by bursts of
410 activity. The bursts are relatively short and the periods of
411 relative idleness between them typically prevent RAPL Power
412 Limit 1 from being exhausted.
413
414 4 – Unknown: Can't classify.
415
416 On processors starting from Panther Lake additional hints are provided.
417 The hardware analyzes workload residencies over an extended period to
418 determine whether the workload classification tends toward idle/battery
419 life states or sustained/performance states. Based on this long-term
420 analysis, it classifies:
421
422 Power Classification: If the workload exhibits more idle or battery life
423 residencies, it is classified as "power".
424
425 Performance Classification: If the workload exhibits more sustained or
426 performance residencies, it is classified as "performance".
427
428 This approach enables applications to ignore short-term workload
429 fluctuations and instead respond to longer-term power vs. performance
430 trends.
431
432 Residency thresholds for this classification are CPU generation-specific.
433 Classification is reported via bit 4 of the workload_type_index:
434