| 1 |
What: /sys/class/thermal/thermal_zoneX/type |
| 2 |
Description: |
| 3 |
Strings which represent the thermal zone type. |
| 4 |
This is given by thermal zone driver as part of registration. |
| 5 |
E.g: "acpitz" indicates it's an ACPI thermal device. |
| 6 |
In order to keep it consistent with hwmon sys attribute; this |
| 7 |
should be a short, lowercase string, not containing spaces nor |
| 8 |
dashes. |
| 9 |
|
| 10 |
RO, Required |
| 11 |
|
| 12 |
What: /sys/class/thermal/thermal_zoneX/temp |
| 13 |
Description: |
| 14 |
Current temperature as reported by thermal zone (sensor). |
| 15 |
|
| 16 |
Unit: millidegree Celsius |
| 17 |
|
| 18 |
RO, Required |
| 19 |
|
| 20 |
What: /sys/class/thermal/thermal_zoneX/mode |
| 21 |
Description: |
| 22 |
One of the predefined values in [enabled, disabled]. |
| 23 |
This file gives information about the algorithm that is |
| 24 |
currently managing the thermal zone. It can be either default |
| 25 |
kernel based algorithm or user space application. |
| 26 |
|
| 27 |
enabled |
| 28 |
enable Kernel Thermal management. |
| 29 |
disabled |
| 30 |
Preventing kernel thermal zone driver actions upon |
| 31 |
trip points so that user application can take full |
| 32 |
charge of the thermal management. |
| 33 |
|
| 34 |
RW, Optional |
| 35 |
|
| 36 |
What: /sys/class/thermal/thermal_zoneX/policy |
| 37 |
Description: |
| 38 |
One of the various thermal governors used for a particular zone. |
| 39 |
|
| 40 |
RW, Required |
| 41 |
|
| 42 |
What: /sys/class/thermal/thermal_zoneX/available_policies |
| 43 |
Description: |
| 44 |
Available thermal governors which can be used for a |
| 45 |
particular zone. |
| 46 |
|
| 47 |
RO, Required |
| 48 |
|
| 49 |
What: /sys/class/thermal/thermal_zoneX/trip_point_Y_temp |
| 50 |
Description: |
| 51 |
The temperature above which trip point will be fired. |
| 52 |
|
| 53 |
Unit: millidegree Celsius |
| 54 |
|
| 55 |
RO, Optional |
| 56 |
|
| 57 |
What: /sys/class/thermal/thermal_zoneX/trip_point_Y_type |
| 58 |
Description: |
| 59 |
Strings which indicate the type of the trip point. |
| 60 |
|
| 61 |
E.g. it can be one of critical, hot, passive, `active[0-*]` |
| 62 |
for ACPI thermal zone. |
| 63 |
|
| 64 |
RO, Optional |
| 65 |
|
| 66 |
What: /sys/class/thermal/thermal_zoneX/trip_point_Y_hyst |
| 67 |
Description: |
| 68 |
The hysteresis value for a trip point, represented as an |
| 69 |
integer. |
| 70 |
|
| 71 |
Unit: Celsius |
| 72 |
|
| 73 |
RW, Optional |
| 74 |
|
| 75 |
What: /sys/class/thermal/thermal_zoneX/cdevY |
| 76 |
Description: |
| 77 |
Sysfs link to the thermal cooling device node where the sys I/F |
| 78 |
for cooling device throttling control represents. |
| 79 |
|
| 80 |
RO, Optional |
| 81 |
|
| 82 |
What: /sys/class/thermal/thermal_zoneX/cdevY_trip_point |
| 83 |
Description: |
| 84 |
The trip point in this thermal zone which `cdev[0-*]` is |
| 85 |
associated with; -1 means the cooling device is not |
| 86 |
associated with any trip point. |
| 87 |
|
| 88 |
RO, Optional |
| 89 |
|
| 90 |
What: /sys/class/thermal/thermal_zoneX/cdevY_weight |
| 91 |
Description: |
| 92 |
The influence of `cdev[0-*]` in this thermal zone. This value |
| 93 |
is relative to the rest of cooling devices in the thermal |
| 94 |
zone. For example, if a cooling device has a weight double |
| 95 |
than that of other, it's twice as effective in cooling the |
| 96 |
thermal zone. |
| 97 |
|
| 98 |
RW, Optional |
| 99 |
|
| 100 |
What: /sys/class/thermal/thermal_zoneX/emul_temp |
| 101 |
Description: |
| 102 |
Interface to set the emulated temperature method in thermal zone |
| 103 |
(sensor). After setting this temperature, the thermal zone may |
| 104 |
pass this temperature to platform emulation function if |
| 105 |
registered or cache it locally. This is useful in debugging |
| 106 |
different temperature threshold and its associated cooling |
| 107 |
action. This is write only node and writing 0 on this node |
| 108 |
should disable emulation. |
| 109 |
|
| 110 |
Unit: millidegree Celsius |
| 111 |
|
| 112 |
WO, Optional |
| 113 |
|
| 114 |
WARNING: |
| 115 |
Be careful while enabling this option on production systems, |
| 116 |
because userland can easily disable the thermal policy by simply |
| 117 |
flooding this sysfs node with low temperature values. |
| 118 |
|
| 119 |
|
| 120 |
What: /sys/class/thermal/thermal_zoneX/k_d |
| 121 |
Description: |
| 122 |
The derivative term of the power allocator governor's PID |
| 123 |
controller. For more information see |
| 124 |
Documentation/driver-api/thermal/power_allocator.rst |
| 125 |
|
| 126 |
RW, Optional |
| 127 |
|
| 128 |
What: /sys/class/thermal/thermal_zoneX/k_i |
| 129 |
Description: |
| 130 |
The integral term of the power allocator governor's PID |
| 131 |
controller. This term allows the PID controller to compensate |
| 132 |
for long term drift. For more information see |
| 133 |
Documentation/driver-api/thermal/power_allocator.rst |
| 134 |
|
| 135 |
RW, Optional |
| 136 |
|
| 137 |
What: /sys/class/thermal/thermal_zoneX/k_po |
| 138 |
Description: |
| 139 |
The proportional term of the power allocator governor's PID |
| 140 |
controller during temperature overshoot. Temperature overshoot |
| 141 |
is when the current temperature is above the "desired |
| 142 |
temperature" trip point. For more information see |
| 143 |
Documentation/driver-api/thermal/power_allocator.rst |
| 144 |
|
| 145 |
RW, Optional |
| 146 |
|
| 147 |
What: /sys/class/thermal/thermal_zoneX/k_pu |
| 148 |
Description: |
| 149 |
The proportional term of the power allocator governor's PID |
| 150 |
controller during temperature undershoot. Temperature undershoot |
| 151 |
is when the current temperature is below the "desired |
| 152 |
temperature" trip point. For more information see |
| 153 |
Documentation/driver-api/thermal/power_allocator.rst |
| 154 |
|
| 155 |
RW, Optional |
| 156 |
|
| 157 |
What: /sys/class/thermal/thermal_zoneX/integral_cutoff |
| 158 |
Description: |
| 159 |
Temperature offset from the desired temperature trip point |
| 160 |
above which the integral term of the power allocator |
| 161 |
governor's PID controller starts accumulating errors. For |
| 162 |
example, if integral_cutoff is 0, then the integral term only |
| 163 |
accumulates error when temperature is above the desired |
| 164 |
temperature trip point. For more information see |
| 165 |
Documentation/driver-api/thermal/power_allocator.rst |
| 166 |
|
| 167 |
Unit: millidegree Celsius |
| 168 |
|
| 169 |
RW, Optional |
| 170 |
|
| 171 |
What: /sys/class/thermal/thermal_zoneX/slope |
| 172 |
Description: |
| 173 |
The slope constant used in a linear extrapolation model |
| 174 |
to determine a hotspot temperature based off the sensor's |
| 175 |
raw readings. It is up to the device driver to determine |
| 176 |
the usage of these values. |
| 177 |
|
| 178 |
RW, Optional |
| 179 |
|
| 180 |
What: /sys/class/thermal/thermal_zoneX/offset |
| 181 |
Description: |
| 182 |
The offset constant used in a linear extrapolation model |
| 183 |
to determine a hotspot temperature based off the sensor's |
| 184 |
raw readings. It is up to the device driver to determine |
| 185 |
the usage of these values. |
| 186 |
|
| 187 |
RW, Optional |
| 188 |
|
| 189 |
What: /sys/class/thermal/thermal_zoneX/sustainable_power |
| 190 |
Description: |
| 191 |
An estimate of the sustained power that can be dissipated by |
| 192 |
the thermal zone. Used by the power allocator governor. For |
| 193 |
more information see |
| 194 |
Documentation/driver-api/thermal/power_allocator.rst |
| 195 |
|
| 196 |
Unit: milliwatts |
| 197 |
|
| 198 |
RW, Optional |
| 199 |
|
| 200 |
What: /sys/class/thermal/cooling_deviceX/type |
| 201 |
Description: |
| 202 |
String which represents the type of device, e.g: |
| 203 |
|
| 204 |
- for generic ACPI: should be "Fan", "Processor" or "LCD" |
| 205 |
- for memory controller device on intel_menlow platform: |
| 206 |
should be "Memory controller". |
| 207 |
|
| 208 |
RO, Required |
| 209 |
|
| 210 |
What: /sys/class/thermal/cooling_deviceX/max_state |
| 211 |
Description: |
| 212 |
The maximum permissible cooling state of this cooling device. |
| 213 |
|
| 214 |
RO, Required |
| 215 |
|
| 216 |
What: /sys/class/thermal/cooling_deviceX/cur_state |
| 217 |
Description: |
| 218 |
The current cooling state of this cooling device. |
| 219 |
The value can any integer numbers between 0 and max_state: |
| 220 |
|
| 221 |
- cur_state == 0 means no cooling |
| 222 |
- cur_state == max_state means the maximum cooling. |
| 223 |
|
| 224 |
RW, Required |
| 225 |
|
| 226 |
What: /sys/class/thermal/cooling_deviceX/stats/reset |
| 227 |
Description: |
| 228 |
Writing any value resets the cooling device's statistics. |
| 229 |
|
| 230 |
WO, Required |
| 231 |
|
| 232 |
What: /sys/class/thermal/cooling_deviceX/stats/time_in_state_ms: |
| 233 |
Description: |
| 234 |
The amount of time spent by the cooling device in various |
| 235 |
cooling states. The output will have "<state> <time>" pair |
| 236 |
in each line, which will mean this cooling device spent <time> |
| 237 |
msec of time at <state>. |
| 238 |
|
| 239 |
Output will have one line for each of the supported states. |
| 240 |
|
| 241 |
RO, Required |
| 242 |
|
| 243 |
What: /sys/class/thermal/cooling_deviceX/stats/total_trans |
| 244 |
Description: |
| 245 |
A single positive value showing the total number of times |
| 246 |
the state of a cooling device is changed. |
| 247 |
|
| 248 |
RO, Required |
| 249 |
|
| 250 |
What: /sys/class/thermal/cooling_deviceX/stats/trans_table |
| 251 |
Description: |
| 252 |
This gives fine grained information about all the cooling state |
| 253 |
transitions. The cat output here is a two dimensional matrix, |
| 254 |
where an entry <i,j> (row i, column j) represents the number |
| 255 |
of transitions from State_i to State_j. If the transition |
| 256 |
table is bigger than PAGE_SIZE, reading this will return |
| 257 |
an -EFBIG error. |
| 258 |
|
| 259 |
RO, Required |