| 1 |
What: /sys/bus/iio/devices/iio:deviceX/in_allow_async_readout |
| 2 |
Date: December 2015 |
| 3 |
KernelVersion: 4.4 |
| 4 |
Contact: [email protected] |
| 5 |
Description: |
| 6 |
By default (value '0'), the capture thread checks for the Conversion |
| 7 |
Ready Flag to being set prior to committing a new value to the sample |
| 8 |
buffer. This synchronizes the in-chip conversion rate with the |
| 9 |
in-driver readout rate at the cost of an additional register read. |
| 10 |
|
| 11 |
Writing '1' will remove the polling for the Conversion Ready Flags to |
| 12 |
save the additional i2c transaction, which will improve the bandwidth |
| 13 |
available for reading data. However, samples can be occasionally skipped |
| 14 |
or repeated, depending on the beat between the capture and conversion |
| 15 |
rates. |