Debian Codegraph @

mibs/SNMPv2-TC

raw
1 -- extracted from rfc2579.txt
2
3 SNMPv2-TC DEFINITIONS ::= BEGIN
4
5 IMPORTS
6 TimeTicks FROM SNMPv2-SMI;
7
8
9 -- definition of textual conventions
10
11 TEXTUAL-CONVENTION MACRO ::=
12 BEGIN
13 TYPE NOTATION ::=
14 DisplayPart
15 "STATUS" Status
16 "DESCRIPTION" Text
17 ReferPart
18 "SYNTAX" Syntax
19
20 VALUE NOTATION ::=
21 value(VALUE Syntax) -- adapted ASN.1
22
23 DisplayPart ::=
24 "DISPLAY-HINT" Text
25 | empty
26
27 Status ::=
28 "current"
29 | "deprecated"
30 | "obsolete"
31
32 ReferPart ::=
33 "REFERENCE" Text
34 | empty
35
36 -- a character string as defined in [2]
37 Text ::= value(IA5String)
38
39 Syntax ::= -- Must be one of the following:
40 -- a base type (or its refinement), or
41 -- a BITS pseudo-type
42 type
43 | "BITS" "{" NamedBits "}"
44
45 NamedBits ::= NamedBit
46 | NamedBits "," NamedBit
47
48 NamedBit ::= identifier "(" number ")" -- number is nonnegative
49
50 END
51
52
53
54
55 DisplayString ::= TEXTUAL-CONVENTION
56 DISPLAY-HINT "255a"
57 STATUS current
58 DESCRIPTION
59 "Represents textual information taken from the NVT ASCII
60 character set, as defined in pages 4, 10-11 of RFC 854.
61
62 To summarize RFC 854, the NVT ASCII repertoire specifies:
63
64 - the use of character codes 0-127 (decimal)
65
66 - the graphics characters (32-126) are interpreted as
67 US ASCII
68
69 - NUL, LF, CR, BEL, BS, HT, VT and FF have the special
70 meanings specified in RFC 854
71
72 - the other 25 codes have no standard interpretation
73
74 - the sequence 'CR LF' means newline
75
76 - the sequence 'CR NUL' means carriage-return
77
78 - an 'LF' not preceded by a 'CR' means moving to the
79 same column on the next line.
80
81 - the sequence 'CR x' for any x other than LF or NUL is
82 illegal. (Note that this also means that a string may
83 end with either 'CR LF' or 'CR NUL', but not with CR.)
84
85 Any object defined using this syntax may not exceed 255
86 characters in length."
87 SYNTAX OCTET STRING (SIZE (0..255))
88
89 PhysAddress ::= TEXTUAL-CONVENTION
90 DISPLAY-HINT "1x:"
91 STATUS current
92 DESCRIPTION
93 "Represents media- or physical-level addresses."
94 SYNTAX OCTET STRING
95
96
97 MacAddress ::= TEXTUAL-CONVENTION
98 DISPLAY-HINT "1x:"
99 STATUS current
100 DESCRIPTION
101 "Represents an 802 MAC address represented in the
102 `canonical' order defined by IEEE 802.1a, i.e., as if it
103 were transmitted least significant bit first, even though
104 802.5 (in contrast to other 802.x protocols) requires MAC
105 addresses to be transmitted most significant bit first."
106 SYNTAX OCTET STRING (SIZE (6))
107
108 TruthValue ::= TEXTUAL-CONVENTION
109 STATUS current
110 DESCRIPTION
111 "Represents a boolean value."
112 SYNTAX INTEGER { true(1), false(2) }
113
114 TestAndIncr ::= TEXTUAL-CONVENTION
115 STATUS current
116 DESCRIPTION
117 "Represents integer-valued information used for atomic
118 operations. When the management protocol is used to specify
119 that an object instance having this syntax is to be
120 modified, the new value supplied via the management protocol
121 must precisely match the value presently held by the
122 instance. If not, the management protocol set operation
123 fails with an error of `inconsistentValue'. Otherwise, if
124 the current value is the maximum value of 2^31-1 (2147483647
125 decimal), then the value held by the instance is wrapped to
126 zero; otherwise, the value held by the instance is
127 incremented by one. (Note that regardless of whether the
128 management protocol set operation succeeds, the variable-
129 binding in the request and response PDUs are identical.)
130
131 The value of the ACCESS clause for objects having this
132 syntax is either `read-write' or `read-create'. When an
133 instance of a columnar object having this syntax is created,
134 any value may be supplied via the management protocol.
135
136 When the network management portion of the system is re-
137 initialized, the value of every object instance having this
138 syntax must either be incremented from its value prior to
139 the re-initialization, or (if the value prior to the re-
140 initialization is unknown) be set to a pseudo-randomly
141 generated value."
142 SYNTAX INTEGER (0..2147483647)
143
144 AutonomousType ::= TEXTUAL-CONVENTION
145 STATUS current
146 DESCRIPTION
147 "Represents an independently extensible type identification
148 value. It may, for example, indicate a particular sub-tree
149 with further MIB definitions, or define a particular type of
150 protocol or hardware."
151 SYNTAX OBJECT IDENTIFIER
152
153
154 InstancePointer ::= TEXTUAL-CONVENTION
155 STATUS obsolete
156 DESCRIPTION
157 "A pointer to either a specific instance of a MIB object or
158 a conceptual row of a MIB table in the managed device. In
159 the latter case, by convention, it is the name of the
160 particular instance of the first accessible columnar object
161 in the conceptual row.
162
163 The two uses of this textual convention are replaced by
164 VariablePointer and RowPointer, respectively."
165 SYNTAX OBJECT IDENTIFIER
166
167
168 VariablePointer ::= TEXTUAL-CONVENTION
169 STATUS current
170 DESCRIPTION
171 "A pointer to a specific object instance. For example,
172 sysContact.0 or ifInOctets.3."
173 SYNTAX OBJECT IDENTIFIER
174
175
176 RowPointer ::= TEXTUAL-CONVENTION
177 STATUS current
178 DESCRIPTION
179 "Represents a pointer to a conceptual row. The value is the
180 name of the instance of the first accessible columnar object
181 in the conceptual row.
182
183 For example, ifIndex.3 would point to the 3rd row in the
184 ifTable (note that if ifIndex were not-accessible, then
185 ifDescr.3 would be used instead)."
186 SYNTAX OBJECT IDENTIFIER
187
188 RowStatus ::= TEXTUAL-CONVENTION
189 STATUS current
190 DESCRIPTION
191 "The RowStatus textual convention is used to manage the
192 creation and deletion of conceptual rows, and is used as the
193 value of the SYNTAX clause for the status column of a
194 conceptual row (as described in Section 7.7.1 of [2].)
195
196 The status column has six defined values:
197
198 - `active', which indicates that the conceptual row is
199 available for use by the managed device;
200
201 - `notInService', which indicates that the conceptual
202 row exists in the agent, but is unavailable for use by
203 the managed device (see NOTE below); 'notInService' has
204 no implication regarding the internal consistency of
205 the row, availability of resources, or consistency with
206 the current state of the managed device;
207
208 - `notReady', which indicates that the conceptual row
209 exists in the agent, but is missing information
210 necessary in order to be available for use by the
211 managed device (i.e., one or more required columns in
212 the conceptual row have not been instanciated);
213
214 - `createAndGo', which is supplied by a management
215 station wishing to create a new instance of a
216 conceptual row and to have its status automatically set
217 to active, making it available for use by the managed
218 device;
219
220 - `createAndWait', which is supplied by a management
221 station wishing to create a new instance of a
222 conceptual row (but not make it available for use by
223 the managed device); and,
224
225 - `destroy', which is supplied by a management station
226 wishing to delete all of the instances associated with
227 an existing conceptual row.
228
229 Whereas five of the six values (all except `notReady') may
230 be specified in a management protocol set operation, only
231 three values will be returned in response to a management
232 protocol retrieval operation: `notReady', `notInService' or
233 `active'. That is, when queried, an existing conceptual row
234 has only three states: it is either available for use by
235 the managed device (the status column has value `active');
236 it is not available for use by the managed device, though
237 the agent has sufficient information to attempt to make it
238 so (the status column has value `notInService'); or, it is
239 not available for use by the managed device, and an attempt
240 to make it so would fail because the agent has insufficient
241 information (the state column has value `notReady').
242
243
244 NOTE WELL
245
246 This textual convention may be used for a MIB table,
247 irrespective of whether the values of that table's
248 conceptual rows are able to be modified while it is
249 active, or whether its conceptual rows must be taken
250 out of service in order to be modified. That is, it is
251 the responsibility of the DESCRIPTION clause of the
252 status column to specify whether the status column must
253 not be `active' in order for the value of some other
254 column of the same conceptual row to be modified. If
255 such a specification is made, affected columns may be
256 changed by an SNMP set PDU if the RowStatus would not
257 be equal to `active' either immediately before or after
258 processing the PDU. In other words, if the PDU also
259 contained a varbind that would change the RowStatus
260 value, the column in question may be changed if the
261 RowStatus was not equal to `active' as the PDU was
262 received, or if the varbind sets the status to a value
263 other than 'active'.
264
265
266 Also note that whenever any elements of a row exist, the
267 RowStatus column must also exist.
268
269 To summarize the effect of having a conceptual row with a
270 status column having a SYNTAX clause value of RowStatus,
271 consider the following state diagram:
272
273
274 STATE
275 +--------------+-----------+-------------+-------------
276 | A | B | C | D
277 | |status col.|status column|
278 |status column | is | is |status column
279 ACTION |does not exist| notReady | notInService| is active
280 --------------+--------------+-----------+-------------+-------------
281 set status |noError ->D|inconsist- |inconsistent-|inconsistent-
282 column to | or | entValue| Value| Value
283 createAndGo |inconsistent- | | |
284 | Value| | |
285 --------------+--------------+-----------+-------------+-------------
286 set status |noError see 1|inconsist- |inconsistent-|inconsistent-
287 column to | or | entValue| Value| Value
288 createAndWait |wrongValue | | |
289 --------------+--------------+-----------+-------------+-------------
290 set status |inconsistent- |inconsist- |noError |noError
291 column to | Value| entValue| |
292 active | | | |
293 | | or | |
294 | | | |
295 | |see 2 ->D|see 8 ->D| ->D
296 --------------+--------------+-----------+-------------+-------------
297 set status |inconsistent- |inconsist- |noError |noError ->C
298 column to | Value| entValue| |
299 notInService | | | |
300 | | or | | or
301 | | | |
302 | |see 3 ->C| ->C|see 6
303 --------------+--------------+-----------+-------------+-------------
304 set status |noError |noError |noError |noError ->A
305 column to | | | | or
306 destroy | ->A| ->A| ->A|see 7
307 --------------+--------------+-----------+-------------+-------------
308 set any other |see 4 |noError |noError |see 5
309 column to some| | | |
310 value | | see 1| ->C| ->D
311 --------------+--------------+-----------+-------------+-------------
312
313 (1) goto B or C, depending on information available to the
314 agent.
315
316 (2) if other variable bindings included in the same PDU,
317 provide values for all columns which are missing but
318 required, and all columns have acceptable values, then
319 return noError and goto D.
320
321 (3) if other variable bindings included in the same PDU,
322 provide legal values for all columns which are missing but
323 required, then return noError and goto C.
324
325 (4) at the discretion of the agent, the return value may be
326 either:
327
328 inconsistentName: because the agent does not choose to
329 create such an instance when the corresponding
330 RowStatus instance does not exist, or
331
332 inconsistentValue: if the supplied value is
333 inconsistent with the state of some other MIB object's
334 value, or
335
336 noError: because the agent chooses to create the
337 instance.
338
339 If noError is returned, then the instance of the status
340 column must also be created, and the new state is B or C,
341 depending on the information available to the agent. If
342 inconsistentName or inconsistentValue is returned, the row
343 remains in state A.
344
345 (5) depending on the MIB definition for the column/table,
346 either noError or inconsistentValue may be returned.
347
348 (6) the return value can indicate one of the following
349 errors:
350
351 wrongValue: because the agent does not support
352 notInService (e.g., an agent which does not support
353 createAndWait), or
354
355 inconsistentValue: because the agent is unable to take
356 the row out of service at this time, perhaps because it
357 is in use and cannot be de-activated.
358
359 (7) the return value can indicate the following error:
360
361 inconsistentValue: because the agent is unable to
362 remove the row at this time, perhaps because it is in
363 use and cannot be de-activated.
364
365 (8) the transition to D can fail, e.g., if the values of the
366 conceptual row are inconsistent, then the error code would
367 be inconsistentValue.
368
369 NOTE: Other processing of (this and other varbinds of) the
370 set request may result in a response other than noError
371 being returned, e.g., wrongValue, noCreation, etc.
372
373
374 Conceptual Row Creation
375
376 There are four potential interactions when creating a
377 conceptual row: selecting an instance-identifier which is
378 not in use; creating the conceptual row; initializing any
379 objects for which the agent does not supply a default; and,
380 making the conceptual row available for use by the managed
381 device.
382
383 Interaction 1: Selecting an Instance-Identifier
384
385 The algorithm used to select an instance-identifier varies
386 for each conceptual row. In some cases, the instance-
387 identifier is semantically significant, e.g., the
388 destination address of a route, and a management station
389 selects the instance-identifier according to the semantics.
390
391 In other cases, the instance-identifier is used solely to
392 distinguish conceptual rows, and a management station
393 without specific knowledge of the conceptual row might
394 examine the instances present in order to determine an
395 unused instance-identifier. (This approach may be used, but
396 it is often highly sub-optimal; however, it is also a
397 questionable practice for a naive management station to
398 attempt conceptual row creation.)
399
400 Alternately, the MIB module which defines the conceptual row
401 might provide one or more objects which provide assistance
402 in determining an unused instance-identifier. For example,
403 if the conceptual row is indexed by an integer-value, then
404 an object having an integer-valued SYNTAX clause might be
405 defined for such a purpose, allowing a management station to
406 issue a management protocol retrieval operation. In order
407 to avoid unnecessary collisions between competing management
408 stations, `adjacent' retrievals of this object should be
409 different.
410
411 Finally, the management station could select a pseudo-random
412 number to use as the index. In the event that this index
413 was already in use and an inconsistentValue was returned in
414 response to the management protocol set operation, the
415 management station should simply select a new pseudo-random
416 number and retry the operation.
417
418 A MIB designer should choose between the two latter
419 algorithms based on the size of the table (and therefore the
420 efficiency of each algorithm). For tables in which a large
421 number of entries are expected, it is recommended that a MIB
422 object be defined that returns an acceptable index for
423 creation. For tables with small numbers of entries, it is
424 recommended that the latter pseudo-random index mechanism be
425 used.
426
427 Interaction 2: Creating the Conceptual Row
428
429 Once an unused instance-identifier has been selected, the
430 management station determines if it wishes to create and
431 activate the conceptual row in one transaction or in a
432 negotiated set of interactions.
433
434 Interaction 2a: Creating and Activating the Conceptual Row
435
436 The management station must first determine the column
437 requirements, i.e., it must determine those columns for
438 which it must or must not provide values. Depending on the
439 complexity of the table and the management station's
440 knowledge of the agent's capabilities, this determination
441 can be made locally by the management station. Alternately,
442 the management station issues a management protocol get
443 operation to examine all columns in the conceptual row that
444 it wishes to create. In response, for each column, there
445 are three possible outcomes:
446
447 - a value is returned, indicating that some other
448 management station has already created this conceptual
449 row. We return to interaction 1.
450
451 - the exception `noSuchInstance' is returned,
452 indicating that the agent implements the object-type
453 associated with this column, and that this column in at
454 least one conceptual row would be accessible in the MIB
455 view used by the retrieval were it to exist. For those
456 columns to which the agent provides read-create access,
457 the `noSuchInstance' exception tells the management
458 station that it should supply a value for this column
459 when the conceptual row is to be created.
460
461 - the exception `noSuchObject' is returned, indicating
462 that the agent does not implement the object-type
463 associated with this column or that there is no
464 conceptual row for which this column would be
465 accessible in the MIB view used by the retrieval. As
466 such, the management station can not issue any
467 management protocol set operations to create an
468 instance of this column.
469
470 Once the column requirements have been determined, a
471 management protocol set operation is accordingly issued.
472 This operation also sets the new instance of the status
473 column to `createAndGo'.
474
475 When the agent processes the set operation, it verifies that
476 it has sufficient information to make the conceptual row
477 available for use by the managed device. The information
478 available to the agent is provided by two sources: the
479 management protocol set operation which creates the
480 conceptual row, and, implementation-specific defaults
481 supplied by the agent (note that an agent must provide
482 implementation-specific defaults for at least those objects
483 which it implements as read-only). If there is sufficient
484 information available, then the conceptual row is created, a
485 `noError' response is returned, the status column is set to
486 `active', and no further interactions are necessary (i.e.,
487 interactions 3 and 4 are skipped). If there is insufficient
488 information, then the conceptual row is not created, and the
489 set operation fails with an error of `inconsistentValue'.
490 On this error, the management station can issue a management
491 protocol retrieval operation to determine if this was
492 because it failed to specify a value for a required column,
493 or, because the selected instance of the status column
494 already existed. In the latter case, we return to
495 interaction 1. In the former case, the management station
496 can re-issue the set operation with the additional
497 information, or begin interaction 2 again using
498 `createAndWait' in order to negotiate creation of the
499 conceptual row.
500
501 NOTE WELL
502
503 Regardless of the method used to determine the column
504 requirements, it is possible that the management
505 station might deem a column necessary when, in fact,
506 the agent will not allow that particular columnar
507 instance to be created or written. In this case, the
508 management protocol set operation will fail with an
509 error such as `noCreation' or `notWritable'. In this
510 case, the management station decides whether it needs
511 to be able to set a value for that particular columnar
512 instance. If not, the management station re-issues the
513 management protocol set operation, but without setting
514 a value for that particular columnar instance;
515 otherwise, the management station aborts the row
516 creation algorithm.
517
518 Interaction 2b: Negotiating the Creation of the Conceptual
519 Row
520
521 The management station issues a management protocol set
522 operation which sets the desired instance of the status
523 column to `createAndWait'. If the agent is unwilling to
524 process a request of this sort, the set operation fails with
525 an error of `wrongValue'. (As a consequence, such an agent
526 must be prepared to accept a single management protocol set
527 operation, i.e., interaction 2a above, containing all of the
528 columns indicated by its column requirements.) Otherwise,
529 the conceptual row is created, a `noError' response is
530 returned, and the status column is immediately set to either
531 `notInService' or `notReady', depending on whether it has
532 sufficient information to (attempt to) make the conceptual
533 row available for use by the managed device. If there is
534 sufficient information available, then the status column is
535 set to `notInService'; otherwise, if there is insufficient
536 information, then the status column is set to `notReady'.
537 Regardless, we proceed to interaction 3.
538
539 Interaction 3: Initializing non-defaulted Objects
540
541 The management station must now determine the column
542 requirements. It issues a management protocol get operation
543 to examine all columns in the created conceptual row. In
544 the response, for each column, there are three possible
545 outcomes:
546
547 - a value is returned, indicating that the agent
548 implements the object-type associated with this column
549 and had sufficient information to provide a value. For
550 those columns to which the agent provides read-create
551 access (and for which the agent allows their values to
552 be changed after their creation), a value return tells
553 the management station that it may issue additional
554 management protocol set operations, if it desires, in
555 order to change the value associated with this column.
556
557 - the exception `noSuchInstance' is returned,
558 indicating that the agent implements the object-type
559 associated with this column, and that this column in at
560 least one conceptual row would be accessible in the MIB
561 view used by the retrieval were it to exist. However,
562 the agent does not have sufficient information to
563 provide a value, and until a value is provided, the
564 conceptual row may not be made available for use by the
565 managed device. For those columns to which the agent
566 provides read-create access, the `noSuchInstance'
567 exception tells the management station that it must
568 issue additional management protocol set operations, in
569 order to provide a value associated with this column.
570
571 - the exception `noSuchObject' is returned, indicating
572 that the agent does not implement the object-type
573 associated with this column or that there is no
574 conceptual row for which this column would be
575 accessible in the MIB view used by the retrieval. As
576 such, the management station can not issue any
577 management protocol set operations to create an
578 instance of this column.
579
580 If the value associated with the status column is
581 `notReady', then the management station must first deal with
582 all `noSuchInstance' columns, if any. Having done so, the
583 value of the status column becomes `notInService', and we
584 proceed to interaction 4.
585
586
587 Interaction 4: Making the Conceptual Row Available
588
589 Once the management station is satisfied with the values
590 associated with the columns of the conceptual row, it issues
591 a management protocol set operation to set the status column
592 to `active'. If the agent has sufficient information to
593 make the conceptual row available for use by the managed
594 device, the management protocol set operation succeeds (a
595 `noError' response is returned). Otherwise, the management
596 protocol set operation fails with an error of
597 `inconsistentValue'.
598
599 NOTE WELL
600
601 A conceptual row having a status column with value
602 `notInService' or `notReady' is unavailable to the
603 managed device. As such, it is possible for the
604 managed device to create its own instances during the
605 time between the management protocol set operation
606 which sets the status column to `createAndWait' and the
607 management protocol set operation which sets the status
608 column to `active'. In this case, when the management
609 protocol set operation is issued to set the status
610 column to `active', the values held in the agent
611 supersede those used by the managed device.
612
613 If the management station is prevented from setting the
614 status column to `active' (e.g., due to management station
615 or network failure) the conceptual row will be left in the
616 `notInService' or `notReady' state, consuming resources
617 indefinitely. The agent must detect conceptual rows that
618 have been in either state for an abnormally long period of
619 time and remove them. It is the responsibility of the
620 DESCRIPTION clause of the status column to indicate what an
621 abnormally long period of time would be. This period of
622 time should be long enough to allow for human response time
623 (including `think time') between the creation of the
624 conceptual row and the setting of the status to `active'.
625 In the absence of such information in the DESCRIPTION
626 clause, it is suggested that this period be approximately 5
627 minutes in length. This removal action applies not only to
628 newly-created rows, but also to previously active rows which
629 are set to, and left in, the notInService state for a
630 prolonged period exceeding that which is considered normal
631 for such a conceptual row.
632
633
634
635 Conceptual Row Suspension
636
637 When a conceptual row is `active', the management station
638 may issue a management protocol set operation which sets the
639 instance of the status column to `notInService'. If the
640 agent is unwilling to do so, the set operation fails with an
641 error of `wrongValue' or `inconsistentValue'. Otherwise,
642 the conceptual row is taken out of service, and a `noError'
643 response is returned. It is the responsibility of the
644 DESCRIPTION clause of the status column to indicate under
645 what circumstances the status column should be taken out of
646 service (e.g., in order for the value of some other column
647 of the same conceptual row to be modified).
648
649
650 Conceptual Row Deletion
651
652 For deletion of conceptual rows, a management protocol set
653 operation is issued which sets the instance of the status
654 column to `destroy'. This request may be made regardless of
655 the current value of the status column (e.g., it is possible
656 to delete conceptual rows which are either `notReady',
657 `notInService' or `active'.) If the operation succeeds,
658 then all instances associated with the conceptual row are
659 immediately removed."
660 SYNTAX INTEGER {
661 -- the following two values are states:
662 -- these values may be read or written
663 active(1),
664 notInService(2),
665
666 -- the following value is a state:
667 -- this value may be read, but not written
668 notReady(3),
669
670 -- the following three values are
671 -- actions: these values may be written,
672 -- but are never read
673 createAndGo(4),
674 createAndWait(5),
675 destroy(6)
676 }
677
678 TimeStamp ::= TEXTUAL-CONVENTION
679 STATUS current
680 DESCRIPTION
681 "The value of the sysUpTime object at which a specific
682 occurrence happened. The specific occurrence must be
683 defined in the description of any object defined using this
684 type.
685
686 If sysUpTime is reset to zero as a result of a re-
687 initialization of the network management (sub)system, then
688 the values of all TimeStamp objects are also reset.
689 However, after approximately 497 days without a re-
690 initialization, the sysUpTime object will reach 2^^32-1 and
691 then increment around to zero; in this case, existing values
692 of TimeStamp objects do not change. This can lead to
693 ambiguities in the value of TimeStamp objects."
694 SYNTAX TimeTicks
695
696
697 TimeInterval ::= TEXTUAL-CONVENTION
698 STATUS current
699 DESCRIPTION
700 "A period of time, measured in units of 0.01 seconds."
701 SYNTAX INTEGER (0..2147483647)
702
703 DateAndTime ::= TEXTUAL-CONVENTION
704 DISPLAY-HINT "2d-1d-1d,1d:1d:1d.1d,1a1d:1d"
705 STATUS current
706 DESCRIPTION
707 "A date-time specification.
708
709 field octets contents range
710 ----- ------ -------- -----
711 1 1-2 year* 0..65536
712 2 3 month 1..12
713 3 4 day 1..31
714 4 5 hour 0..23
715 5 6 minutes 0..59
716 6 7 seconds 0..60
717 (use 60 for leap-second)
718 7 8 deci-seconds 0..9
719 8 9 direction from UTC '+' / '-'
720 9 10 hours from UTC* 0..13
721 10 11 minutes from UTC 0..59
722
723 * Notes:
724 - the value of year is in network-byte order
725 - daylight saving time in New Zealand is +13
726
727 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be
728 displayed as:
729
730 1992-5-26,13:30:15.0,-4:0
731
732 Note that if only local time is known, then timezone
733 information (fields 8-10) is not present."
734 SYNTAX OCTET STRING (SIZE (8 | 11))
735
736
737 StorageType ::= TEXTUAL-CONVENTION
738 STATUS current
739 DESCRIPTION
740 "Describes the memory realization of a conceptual row. A
741 row which is volatile(2) is lost upon reboot. A row which
742 is either nonVolatile(3), permanent(4) or readOnly(5), is
743 backed up by stable storage. A row which is permanent(4)
744 can be changed but not deleted. A row which is readOnly(5)
745 cannot be changed nor deleted.
746
747 If the value of an object with this syntax is either
748 permanent(4) or readOnly(5), it cannot be written.
749 Conversely, if the value is either other(1), volatile(2) or
750 nonVolatile(3), it cannot be modified to be permanent(4) or
751 readOnly(5). (All illegal modifications result in a
752 'wrongValue' error.)
753
754 Every usage of this textual convention is required to
755 specify the columnar objects which a permanent(4) row must
756 at a minimum allow to be writable."
757 SYNTAX INTEGER {
758 other(1), -- eh?
759 volatile(2), -- e.g., in RAM
760 nonVolatile(3), -- e.g., in NVRAM
761 permanent(4), -- e.g., partially in ROM
762 readOnly(5) -- e.g., completely in ROM
763 }
764
765 TDomain ::= TEXTUAL-CONVENTION
766 STATUS current
767 DESCRIPTION
768 "Denotes a kind of transport service.
769
770 Some possible values, such as snmpUDPDomain, are defined in
771 the SNMPv2-TM MIB module. Other possible values are defined
772 in other MIB modules."
773 REFERENCE "The SNMPv2-TM MIB module is defined in RFC 1906."
774 SYNTAX OBJECT IDENTIFIER
775
776
777 TAddress ::= TEXTUAL-CONVENTION
778 STATUS current
779 DESCRIPTION
780 "Denotes a transport service address.
781
782 A TAddress value is always interpreted within the context of a
783 TDomain value. Thus, each definition of a TDomain value must
784 be accompanied by a definition of a textual convention for use
785 with that TDomain. Some possible textual conventions, such as
786 SnmpUDPAddress for snmpUDPDomain, are defined in the SNMPv2-TM
787 MIB module. Other possible textual conventions are defined in
788 other MIB modules."
789 REFERENCE "The SNMPv2-TM MIB module is defined in RFC 1906."
790 SYNTAX OCTET STRING (SIZE (1..255))