| 1 |
-- extracted from rfc2233.txt |
| 2 |
|
| 3 |
IF-MIB DEFINITIONS ::= BEGIN |
| 4 |
|
| 5 |
IMPORTS |
| 6 |
MODULE-IDENTITY, OBJECT-TYPE, Counter32, Gauge32, Counter64, |
| 7 |
Integer32, TimeTicks, mib-2, |
| 8 |
NOTIFICATION-TYPE FROM SNMPv2-SMI |
| 9 |
TEXTUAL-CONVENTION, DisplayString, |
| 10 |
PhysAddress, TruthValue, RowStatus, |
| 11 |
TimeStamp, AutonomousType, TestAndIncr FROM SNMPv2-TC |
| 12 |
MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF |
| 13 |
snmpTraps FROM SNMPv2-MIB |
| 14 |
IANAifType FROM IANAifType-MIB; |
| 15 |
|
| 16 |
ifMIB MODULE-IDENTITY |
| 17 |
LAST-UPDATED "9611031355Z" |
| 18 |
ORGANIZATION "IETF Interfaces MIB Working Group" |
| 19 |
CONTACT-INFO |
| 20 |
" Keith McCloghrie |
| 21 |
Cisco Systems, Inc. |
| 22 |
170 West Tasman Drive |
| 23 |
San Jose, CA 95134-1706 |
| 24 |
US |
| 25 |
|
| 26 |
408-526-5260 |
| 27 |
[email protected]" |
| 28 |
DESCRIPTION |
| 29 |
"The MIB module to describe generic objects for |
| 30 |
network interface sub-layers. This MIB is an updated |
| 31 |
version of MIB-II's ifTable, and incorporates the |
| 32 |
extensions defined in RFC 1229." |
| 33 |
REVISION "9602282155Z" |
| 34 |
DESCRIPTION |
| 35 |
"Revisions made by the Interfaces MIB WG." |
| 36 |
REVISION "9311082155Z" |
| 37 |
DESCRIPTION |
| 38 |
"Initial revision, published as part of RFC 1573." |
| 39 |
::= { mib-2 31 } |
| 40 |
|
| 41 |
|
| 42 |
ifMIBObjects OBJECT IDENTIFIER ::= { ifMIB 1 } |
| 43 |
|
| 44 |
interfaces OBJECT IDENTIFIER ::= { mib-2 2 } |
| 45 |
|
| 46 |
|
| 47 |
OwnerString ::= TEXTUAL-CONVENTION |
| 48 |
DISPLAY-HINT "255a" |
| 49 |
STATUS current |
| 50 |
DESCRIPTION |
| 51 |
"This data type is used to model an administratively |
| 52 |
assigned name of the owner of a resource. This |
| 53 |
information is taken from the NVT ASCII character set. |
| 54 |
It is suggested that this name contain one or more of |
| 55 |
the following: ASCII form of the manager station's |
| 56 |
transport address, management station name (e.g., |
| 57 |
domain name), network management personnel's name, |
| 58 |
location, or phone number. In some cases the agent |
| 59 |
itself will be the owner of an entry. In these cases, |
| 60 |
this string shall be set to a string starting with |
| 61 |
'agent'." |
| 62 |
SYNTAX OCTET STRING (SIZE(0..255)) |
| 63 |
|
| 64 |
-- InterfaceIndex contains the semantics of ifIndex and |
| 65 |
-- should be used for any objects defined on other mib |
| 66 |
-- modules that need these semantics. |
| 67 |
|
| 68 |
InterfaceIndex ::= TEXTUAL-CONVENTION |
| 69 |
DISPLAY-HINT "d" |
| 70 |
STATUS current |
| 71 |
DESCRIPTION |
| 72 |
"A unique value, greater than zero, for each interface |
| 73 |
or interface sub-layer in the managed system. It is |
| 74 |
recommended that values are assigned contiguously |
| 75 |
starting from 1. The value for each interface sub- |
| 76 |
layer must remain constant at least from one re- |
| 77 |
initialization of the entity's network management |
| 78 |
system to the next re-initialization." |
| 79 |
SYNTAX Integer32 (1..2147483647) |
| 80 |
|
| 81 |
|
| 82 |
InterfaceIndexOrZero ::= TEXTUAL-CONVENTION |
| 83 |
DISPLAY-HINT "d" |
| 84 |
STATUS current |
| 85 |
DESCRIPTION |
| 86 |
"This textual convention is an extension of the |
| 87 |
InterfaceIndex convention. The latter defines a |
| 88 |
greater than zero value used to identify an interface |
| 89 |
or interface sub-layer in the managed system. This |
| 90 |
extension permits the additional value of zero. the |
| 91 |
value zero is object-specific and must therefore be |
| 92 |
defined as part of the description of any object which |
| 93 |
uses this syntax. Examples of the usage of zero might |
| 94 |
include situations where interface was unknown, or |
| 95 |
when none or all interfaces need to be referenced." |
| 96 |
SYNTAX Integer32 (0..2147483647) |
| 97 |
|
| 98 |
|
| 99 |
ifNumber OBJECT-TYPE |
| 100 |
SYNTAX Integer32 |
| 101 |
MAX-ACCESS read-only |
| 102 |
STATUS current |
| 103 |
DESCRIPTION |
| 104 |
"The number of network interfaces (regardless of their |
| 105 |
current state) present on this system." |
| 106 |
::= { interfaces 1 } |
| 107 |
|
| 108 |
ifTableLastChange OBJECT-TYPE |
| 109 |
SYNTAX TimeTicks |
| 110 |
MAX-ACCESS read-only |
| 111 |
STATUS current |
| 112 |
DESCRIPTION |
| 113 |
"The value of sysUpTime at the time of the last |
| 114 |
creation or deletion of an entry in the ifTable. If |
| 115 |
the number of entries has been unchanged since the |
| 116 |
last re-initialization of the local network management |
| 117 |
subsystem, then this object contains a zero value." |
| 118 |
::= { ifMIBObjects 5 } |
| 119 |
|
| 120 |
|
| 121 |
-- the Interfaces table |
| 122 |
|
| 123 |
-- The Interfaces table contains information on the entity's |
| 124 |
-- interfaces. Each sub-layer below the internetwork-layer |
| 125 |
-- of a network interface is considered to be an interface. |
| 126 |
|
| 127 |
ifTable OBJECT-TYPE |
| 128 |
SYNTAX SEQUENCE OF IfEntry |
| 129 |
MAX-ACCESS not-accessible |
| 130 |
STATUS current |
| 131 |
DESCRIPTION |
| 132 |
"A list of interface entries. The number of entries |
| 133 |
is given by the value of ifNumber." |
| 134 |
::= { interfaces 2 } |
| 135 |
|
| 136 |
ifEntry OBJECT-TYPE |
| 137 |
SYNTAX IfEntry |
| 138 |
MAX-ACCESS not-accessible |
| 139 |
STATUS current |
| 140 |
DESCRIPTION |
| 141 |
"An entry containing management information applicable |
| 142 |
to a particular interface." |
| 143 |
INDEX { ifIndex } |
| 144 |
|
| 145 |
|
| 146 |
|
| 147 |
::= { ifTable 1 } |
| 148 |
|
| 149 |
IfEntry ::= |
| 150 |
SEQUENCE { |
| 151 |
ifIndex InterfaceIndex, |
| 152 |
ifDescr DisplayString, |
| 153 |
ifType IANAifType, |
| 154 |
ifMtu Integer32, |
| 155 |
ifSpeed Gauge32, |
| 156 |
ifPhysAddress PhysAddress, |
| 157 |
ifAdminStatus INTEGER, |
| 158 |
ifOperStatus INTEGER, |
| 159 |
ifLastChange TimeTicks, |
| 160 |
ifInOctets Counter32, |
| 161 |
ifInUcastPkts Counter32, |
| 162 |
ifInNUcastPkts Counter32, -- deprecated |
| 163 |
ifInDiscards Counter32, |
| 164 |
ifInErrors Counter32, |
| 165 |
ifInUnknownProtos Counter32, |
| 166 |
ifOutOctets Counter32, |
| 167 |
ifOutUcastPkts Counter32, |
| 168 |
ifOutNUcastPkts Counter32, -- deprecated |
| 169 |
ifOutDiscards Counter32, |
| 170 |
ifOutErrors Counter32, |
| 171 |
ifOutQLen Gauge32, -- deprecated |
| 172 |
ifSpecific OBJECT IDENTIFIER -- deprecated |
| 173 |
} |
| 174 |
|
| 175 |
|
| 176 |
ifIndex OBJECT-TYPE |
| 177 |
SYNTAX InterfaceIndex |
| 178 |
MAX-ACCESS read-only |
| 179 |
STATUS current |
| 180 |
DESCRIPTION |
| 181 |
"A unique value, greater than zero, for each |
| 182 |
interface. It is recommended that values are assigned |
| 183 |
contiguously starting from 1. The value for each |
| 184 |
interface sub-layer must remain constant at least from |
| 185 |
one re-initialization of the entity's network |
| 186 |
management system to the next re-initialization." |
| 187 |
::= { ifEntry 1 } |
| 188 |
|
| 189 |
ifDescr OBJECT-TYPE |
| 190 |
SYNTAX DisplayString (SIZE (0..255)) |
| 191 |
MAX-ACCESS read-only |
| 192 |
|
| 193 |
|
| 194 |
STATUS current |
| 195 |
DESCRIPTION |
| 196 |
"A textual string containing information about the |
| 197 |
interface. This string should include the name of the |
| 198 |
manufacturer, the product name and the version of the |
| 199 |
interface hardware/software." |
| 200 |
::= { ifEntry 2 } |
| 201 |
|
| 202 |
ifType OBJECT-TYPE |
| 203 |
SYNTAX IANAifType |
| 204 |
MAX-ACCESS read-only |
| 205 |
STATUS current |
| 206 |
DESCRIPTION |
| 207 |
"The type of interface. Additional values for ifType |
| 208 |
are assigned by the Internet Assigned Numbers |
| 209 |
Authority (IANA), through updating the syntax of the |
| 210 |
IANAifType textual convention." |
| 211 |
::= { ifEntry 3 } |
| 212 |
|
| 213 |
ifMtu OBJECT-TYPE |
| 214 |
SYNTAX Integer32 |
| 215 |
MAX-ACCESS read-only |
| 216 |
STATUS current |
| 217 |
DESCRIPTION |
| 218 |
"The size of the largest packet which can be |
| 219 |
sent/received on the interface, specified in octets. |
| 220 |
For interfaces that are used for transmitting network |
| 221 |
datagrams, this is the size of the largest network |
| 222 |
datagram that can be sent on the interface." |
| 223 |
::= { ifEntry 4 } |
| 224 |
|
| 225 |
ifSpeed OBJECT-TYPE |
| 226 |
SYNTAX Gauge32 |
| 227 |
MAX-ACCESS read-only |
| 228 |
STATUS current |
| 229 |
DESCRIPTION |
| 230 |
"An estimate of the interface's current bandwidth in |
| 231 |
bits per second. For interfaces which do not vary in |
| 232 |
bandwidth or for those where no accurate estimation |
| 233 |
can be made, this object should contain the nominal |
| 234 |
bandwidth. If the bandwidth of the interface is |
| 235 |
greater than the maximum value reportable by this |
| 236 |
object then this object should report its maximum |
| 237 |
value (4,294,967,295) and ifHighSpeed must be used to |
| 238 |
report the interace's speed. For a sub-layer which |
| 239 |
has no concept of bandwidth, this object should be |
| 240 |
zero." |
| 241 |
::= { ifEntry 5 } |
| 242 |
|
| 243 |
ifPhysAddress OBJECT-TYPE |
| 244 |
SYNTAX PhysAddress |
| 245 |
MAX-ACCESS read-only |
| 246 |
STATUS current |
| 247 |
DESCRIPTION |
| 248 |
"The interface's address at its protocol sub-layer. |
| 249 |
For example, for an 802.x interface, this object |
| 250 |
normally contains a MAC address. The interface's |
| 251 |
media-specific MIB must define the bit and byte |
| 252 |
ordering and the format of the value of this object. |
| 253 |
For interfaces which do not have such an address |
| 254 |
(e.g., a serial line), this object should contain an |
| 255 |
octet string of zero length." |
| 256 |
::= { ifEntry 6 } |
| 257 |
|
| 258 |
ifAdminStatus OBJECT-TYPE |
| 259 |
SYNTAX INTEGER { |
| 260 |
up(1), -- ready to pass packets |
| 261 |
down(2), |
| 262 |
testing(3) -- in some test mode |
| 263 |
} |
| 264 |
MAX-ACCESS read-write |
| 265 |
STATUS current |
| 266 |
DESCRIPTION |
| 267 |
"The desired state of the interface. The testing(3) |
| 268 |
state indicates that no operational packets can be |
| 269 |
passed. When a managed system initializes, all |
| 270 |
interfaces start with ifAdminStatus in the down(2) |
| 271 |
state. As a result of either explicit management |
| 272 |
action or per configuration information retained by |
| 273 |
the managed system, ifAdminStatus is then changed to |
| 274 |
either the up(1) or testing(3) states (or remains in |
| 275 |
the down(2) state)." |
| 276 |
::= { ifEntry 7 } |
| 277 |
|
| 278 |
ifOperStatus OBJECT-TYPE |
| 279 |
SYNTAX INTEGER { |
| 280 |
up(1), -- ready to pass packets |
| 281 |
down(2), |
| 282 |
testing(3), -- in some test mode |
| 283 |
unknown(4), -- status can not be determined |
| 284 |
-- for some reason. |
| 285 |
dormant(5), |
| 286 |
notPresent(6), -- some component is missing |
| 287 |
lowerLayerDown(7) -- down due to state of |
| 288 |
-- lower-layer interface(s) |
| 289 |
} |
| 290 |
MAX-ACCESS read-only |
| 291 |
STATUS current |
| 292 |
DESCRIPTION |
| 293 |
"The current operational state of the interface. The |
| 294 |
testing(3) state indicates that no operational packets |
| 295 |
can be passed. If ifAdminStatus is down(2) then |
| 296 |
ifOperStatus should be down(2). If ifAdminStatus is |
| 297 |
changed to up(1) then ifOperStatus should change to |
| 298 |
up(1) if the interface is ready to transmit and |
| 299 |
receive network traffic; it should change to |
| 300 |
dormant(5) if the interface is waiting for external |
| 301 |
actions (such as a serial line waiting for an incoming |
| 302 |
connection); it should remain in the down(2) state if |
| 303 |
and only if there is a fault that prevents it from |
| 304 |
going to the up(1) state; it should remain in the |
| 305 |
notPresent(6) state if the interface has missing |
| 306 |
(typically, hardware) components." |
| 307 |
::= { ifEntry 8 } |
| 308 |
|
| 309 |
ifLastChange OBJECT-TYPE |
| 310 |
SYNTAX TimeTicks |
| 311 |
MAX-ACCESS read-only |
| 312 |
STATUS current |
| 313 |
DESCRIPTION |
| 314 |
"The value of sysUpTime at the time the interface |
| 315 |
entered its current operational state. If the current |
| 316 |
state was entered prior to the last re-initialization |
| 317 |
of the local network management subsystem, then this |
| 318 |
object contains a zero value." |
| 319 |
::= { ifEntry 9 } |
| 320 |
|
| 321 |
ifInOctets OBJECT-TYPE |
| 322 |
SYNTAX Counter32 |
| 323 |
MAX-ACCESS read-only |
| 324 |
STATUS current |
| 325 |
DESCRIPTION |
| 326 |
"The total number of octets received on the interface, |
| 327 |
including framing characters. |
| 328 |
|
| 329 |
Discontinuities in the value of this counter can occur |
| 330 |
at re-initialization of the management system, and at |
| 331 |
other times as indicated by the value of |
| 332 |
ifCounterDiscontinuityTime." |
| 333 |
::= { ifEntry 10 } |
| 334 |
|
| 335 |
ifInUcastPkts OBJECT-TYPE |
| 336 |
SYNTAX Counter32 |
| 337 |
MAX-ACCESS read-only |
| 338 |
STATUS current |
| 339 |
DESCRIPTION |
| 340 |
"The number of packets, delivered by this sub-layer to |
| 341 |
a higher (sub-)layer, which were not addressed to a |
| 342 |
multicast or broadcast address at this sub-layer. |
| 343 |
|
| 344 |
Discontinuities in the value of this counter can occur |
| 345 |
at re-initialization of the management system, and at |
| 346 |
other times as indicated by the value of |
| 347 |
ifCounterDiscontinuityTime." |
| 348 |
::= { ifEntry 11 } |
| 349 |
|
| 350 |
ifInNUcastPkts OBJECT-TYPE |
| 351 |
SYNTAX Counter32 |
| 352 |
MAX-ACCESS read-only |
| 353 |
STATUS deprecated |
| 354 |
DESCRIPTION |
| 355 |
"The number of packets, delivered by this sub-layer to |
| 356 |
a higher (sub-)layer, which were addressed to a |
| 357 |
multicast or broadcast address at this sub-layer. |
| 358 |
|
| 359 |
Discontinuities in the value of this counter can occur |
| 360 |
at re-initialization of the management system, and at |
| 361 |
other times as indicated by the value of |
| 362 |
ifCounterDiscontinuityTime. |
| 363 |
|
| 364 |
This object is deprecated in favour of |
| 365 |
ifInMulticastPkts and ifInBroadcastPkts." |
| 366 |
::= { ifEntry 12 } |
| 367 |
|
| 368 |
ifInDiscards OBJECT-TYPE |
| 369 |
SYNTAX Counter32 |
| 370 |
MAX-ACCESS read-only |
| 371 |
STATUS current |
| 372 |
DESCRIPTION |
| 373 |
"The number of inbound packets which were chosen to be |
| 374 |
discarded even though no errors had been detected to |
| 375 |
prevent their being deliverable to a higher-layer |
| 376 |
protocol. One possible reason for discarding such a |
| 377 |
packet could be to free up buffer space. |
| 378 |
|
| 379 |
Discontinuities in the value of this counter can occur |
| 380 |
at re-initialization of the management system, and at |
| 381 |
other times as indicated by the value of |
| 382 |
ifCounterDiscontinuityTime." |
| 383 |
::= { ifEntry 13 } |
| 384 |
|
| 385 |
ifInErrors OBJECT-TYPE |
| 386 |
SYNTAX Counter32 |
| 387 |
MAX-ACCESS read-only |
| 388 |
STATUS current |
| 389 |
DESCRIPTION |
| 390 |
"For packet-oriented interfaces, the number of inbound |
| 391 |
packets that contained errors preventing them from |
| 392 |
being deliverable to a higher-layer protocol. For |
| 393 |
character-oriented or fixed-length interfaces, the |
| 394 |
number of inbound transmission units that contained |
| 395 |
errors preventing them from being deliverable to a |
| 396 |
higher-layer protocol. |
| 397 |
|
| 398 |
Discontinuities in the value of this counter can occur |
| 399 |
at re-initialization of the management system, and at |
| 400 |
other times as indicated by the value of |
| 401 |
ifCounterDiscontinuityTime." |
| 402 |
::= { ifEntry 14 } |
| 403 |
|
| 404 |
ifInUnknownProtos OBJECT-TYPE |
| 405 |
SYNTAX Counter32 |
| 406 |
MAX-ACCESS read-only |
| 407 |
STATUS current |
| 408 |
DESCRIPTION |
| 409 |
"For packet-oriented interfaces, the number of packets |
| 410 |
received via the interface which were discarded |
| 411 |
because of an unknown or unsupported protocol. For |
| 412 |
character-oriented or fixed-length interfaces that |
| 413 |
support protocol multiplexing the number of |
| 414 |
transmission units received via the interface which |
| 415 |
were discarded because of an unknown or unsupported |
| 416 |
protocol. For any interface that does not support |
| 417 |
protocol multiplexing, this counter will always be 0. |
| 418 |
|
| 419 |
Discontinuities in the value of this counter can occur |
| 420 |
at re-initialization of the management system, and at |
| 421 |
other times as indicated by the value of |
| 422 |
ifCounterDiscontinuityTime." |
| 423 |
::= { ifEntry 15 } |
| 424 |
|
| 425 |
ifOutOctets OBJECT-TYPE |
| 426 |
SYNTAX Counter32 |
| 427 |
MAX-ACCESS read-only |
| 428 |
STATUS current |
| 429 |
DESCRIPTION |
| 430 |
"The total number of octets transmitted out of the |
| 431 |
interface, including framing characters. |
| 432 |
|
| 433 |
Discontinuities in the value of this counter can occur |
| 434 |
at re-initialization of the management system, and at |
| 435 |
other times as indicated by the value of |
| 436 |
ifCounterDiscontinuityTime." |
| 437 |
::= { ifEntry 16 } |
| 438 |
|
| 439 |
ifOutUcastPkts OBJECT-TYPE |
| 440 |
SYNTAX Counter32 |
| 441 |
MAX-ACCESS read-only |
| 442 |
STATUS current |
| 443 |
DESCRIPTION |
| 444 |
"The total number of packets that higher-level |
| 445 |
protocols requested be transmitted, and which were not |
| 446 |
addressed to a multicast or broadcast address at this |
| 447 |
sub-layer, including those that were discarded or not |
| 448 |
sent. |
| 449 |
|
| 450 |
Discontinuities in the value of this counter can occur |
| 451 |
at re-initialization of the management system, and at |
| 452 |
other times as indicated by the value of |
| 453 |
ifCounterDiscontinuityTime." |
| 454 |
::= { ifEntry 17 } |
| 455 |
|
| 456 |
ifOutNUcastPkts OBJECT-TYPE |
| 457 |
SYNTAX Counter32 |
| 458 |
MAX-ACCESS read-only |
| 459 |
STATUS deprecated |
| 460 |
DESCRIPTION |
| 461 |
"The total number of packets that higher-level |
| 462 |
protocols requested be transmitted, and which were |
| 463 |
addressed to a multicast or broadcast address at this |
| 464 |
sub-layer, including those that were discarded or not |
| 465 |
sent. |
| 466 |
|
| 467 |
Discontinuities in the value of this counter can occur |
| 468 |
at re-initialization of the management system, and at |
| 469 |
other times as indicated by the value of |
| 470 |
ifCounterDiscontinuityTime. |
| 471 |
This object is deprecated in favour of |
| 472 |
ifOutMulticastPkts and ifOutBroadcastPkts." |
| 473 |
::= { ifEntry 18 } |
| 474 |
|
| 475 |
ifOutDiscards OBJECT-TYPE |
| 476 |
SYNTAX Counter32 |
| 477 |
MAX-ACCESS read-only |
| 478 |
STATUS current |
| 479 |
DESCRIPTION |
| 480 |
"The number of outbound packets which were chosen to |
| 481 |
be discarded even though no errors had been detected |
| 482 |
to prevent their being transmitted. One possible |
| 483 |
reason for discarding such a packet could be to free |
| 484 |
up buffer space. |
| 485 |
|
| 486 |
Discontinuities in the value of this counter can occur |
| 487 |
at re-initialization of the management system, and at |
| 488 |
other times as indicated by the value of |
| 489 |
ifCounterDiscontinuityTime." |
| 490 |
::= { ifEntry 19 } |
| 491 |
|
| 492 |
ifOutErrors OBJECT-TYPE |
| 493 |
SYNTAX Counter32 |
| 494 |
MAX-ACCESS read-only |
| 495 |
STATUS current |
| 496 |
DESCRIPTION |
| 497 |
"For packet-oriented interfaces, the number of |
| 498 |
outbound packets that could not be transmitted because |
| 499 |
of errors. For character-oriented or fixed-length |
| 500 |
interfaces, the number of outbound transmission units |
| 501 |
that could not be transmitted because of errors. |
| 502 |
|
| 503 |
Discontinuities in the value of this counter can occur |
| 504 |
at re-initialization of the management system, and at |
| 505 |
other times as indicated by the value of |
| 506 |
ifCounterDiscontinuityTime." |
| 507 |
::= { ifEntry 20 } |
| 508 |
|
| 509 |
|
| 510 |
ifOutQLen OBJECT-TYPE |
| 511 |
SYNTAX Gauge32 |
| 512 |
MAX-ACCESS read-only |
| 513 |
STATUS deprecated |
| 514 |
DESCRIPTION |
| 515 |
"The length of the output packet queue (in packets)." |
| 516 |
::= { ifEntry 21 } |
| 517 |
|
| 518 |
ifSpecific OBJECT-TYPE |
| 519 |
SYNTAX OBJECT IDENTIFIER |
| 520 |
MAX-ACCESS read-only |
| 521 |
STATUS deprecated |
| 522 |
DESCRIPTION |
| 523 |
"A reference to MIB definitions specific to the |
| 524 |
particular media being used to realize the interface. |
| 525 |
It is recommended that this value point to an instance |
| 526 |
of a MIB object in the media-specific MIB, i.e., that |
| 527 |
this object have the semantics associated with the |
| 528 |
InstancePointer textual convention defined in RFC |
| 529 |
1903. In fact, it is recommended that the media- |
| 530 |
specific MIB specify what value ifSpecific should/can |
| 531 |
take for values of ifType. If no MIB definitions |
| 532 |
specific to the particular media are available, the |
| 533 |
value should be set to the OBJECT IDENTIFIER { 0 0 }." |
| 534 |
::= { ifEntry 22 } |
| 535 |
|
| 536 |
|
| 537 |
|
| 538 |
-- |
| 539 |
-- Extension to the interface table |
| 540 |
-- |
| 541 |
-- This table replaces the ifExtnsTable table. |
| 542 |
-- |
| 543 |
|
| 544 |
ifXTable OBJECT-TYPE |
| 545 |
SYNTAX SEQUENCE OF IfXEntry |
| 546 |
MAX-ACCESS not-accessible |
| 547 |
STATUS current |
| 548 |
DESCRIPTION |
| 549 |
"A list of interface entries. The number of entries |
| 550 |
is given by the value of ifNumber. This table |
| 551 |
contains additional objects for the interface table." |
| 552 |
::= { ifMIBObjects 1 } |
| 553 |
|
| 554 |
ifXEntry OBJECT-TYPE |
| 555 |
SYNTAX IfXEntry |
| 556 |
MAX-ACCESS not-accessible |
| 557 |
STATUS current |
| 558 |
DESCRIPTION |
| 559 |
"An entry containing additional management information |
| 560 |
applicable to a particular interface." |
| 561 |
AUGMENTS { ifEntry } |
| 562 |
::= { ifXTable 1 } |
| 563 |
|
| 564 |
IfXEntry ::= |
| 565 |
SEQUENCE { |
| 566 |
ifName DisplayString, |
| 567 |
ifInMulticastPkts Counter32, |
| 568 |
ifInBroadcastPkts Counter32, |
| 569 |
ifOutMulticastPkts Counter32, |
| 570 |
ifOutBroadcastPkts Counter32, |
| 571 |
ifHCInOctets Counter64, |
| 572 |
ifHCInUcastPkts Counter64, |
| 573 |
ifHCInMulticastPkts Counter64, |
| 574 |
ifHCInBroadcastPkts Counter64, |
| 575 |
ifHCOutOctets Counter64, |
| 576 |
ifHCOutUcastPkts Counter64, |
| 577 |
ifHCOutMulticastPkts Counter64, |
| 578 |
ifHCOutBroadcastPkts Counter64, |
| 579 |
ifLinkUpDownTrapEnable INTEGER, |
| 580 |
ifHighSpeed Gauge32, |
| 581 |
ifPromiscuousMode TruthValue, |
| 582 |
ifConnectorPresent TruthValue, |
| 583 |
ifAlias DisplayString, |
| 584 |
ifCounterDiscontinuityTime TimeStamp |
| 585 |
} |
| 586 |
|
| 587 |
|
| 588 |
ifName OBJECT-TYPE |
| 589 |
SYNTAX DisplayString |
| 590 |
MAX-ACCESS read-only |
| 591 |
STATUS current |
| 592 |
DESCRIPTION |
| 593 |
"The textual name of the interface. The value of this |
| 594 |
object should be the name of the interface as assigned |
| 595 |
by the local device and should be suitable for use in |
| 596 |
commands entered at the device's `console'. This |
| 597 |
might be a text name, such as `le0' or a simple port |
| 598 |
number, such as `1', depending on the interface naming |
| 599 |
syntax of the device. If several entries in the |
| 600 |
ifTable together represent a single interface as named |
| 601 |
by the device, then each will have the same value of |
| 602 |
ifName. Note that for an agent which responds to SNMP |
| 603 |
queries concerning an interface on some other |
| 604 |
(proxied) device, then the value of ifName for such an |
| 605 |
interface is the proxied device's local name for it. |
| 606 |
|
| 607 |
If there is no local name, or this object is otherwise |
| 608 |
not applicable, then this object contains a zero- |
| 609 |
length string." |
| 610 |
::= { ifXEntry 1 } |
| 611 |
|
| 612 |
ifInMulticastPkts OBJECT-TYPE |
| 613 |
SYNTAX Counter32 |
| 614 |
MAX-ACCESS read-only |
| 615 |
STATUS current |
| 616 |
DESCRIPTION |
| 617 |
"The number of packets, delivered by this sub-layer to |
| 618 |
a higher (sub-)layer, which were addressed to a |
| 619 |
multicast address at this sub-layer. For a MAC layer |
| 620 |
protocol, this includes both Group and Functional |
| 621 |
addresses. |
| 622 |
|
| 623 |
Discontinuities in the value of this counter can occur |
| 624 |
at re-initialization of the management system, and at |
| 625 |
other times as indicated by the value of |
| 626 |
ifCounterDiscontinuityTime." |
| 627 |
::= { ifXEntry 2 } |
| 628 |
|
| 629 |
ifInBroadcastPkts OBJECT-TYPE |
| 630 |
SYNTAX Counter32 |
| 631 |
MAX-ACCESS read-only |
| 632 |
STATUS current |
| 633 |
DESCRIPTION |
| 634 |
"The number of packets, delivered by this sub-layer to |
| 635 |
a higher (sub-)layer, which were addressed to a |
| 636 |
broadcast address at this sub-layer. |
| 637 |
|
| 638 |
Discontinuities in the value of this counter can occur |
| 639 |
at re-initialization of the management system, and at |
| 640 |
other times as indicated by the value of |
| 641 |
ifCounterDiscontinuityTime." |
| 642 |
::= { ifXEntry 3 } |
| 643 |
|
| 644 |
ifOutMulticastPkts OBJECT-TYPE |
| 645 |
SYNTAX Counter32 |
| 646 |
MAX-ACCESS read-only |
| 647 |
STATUS current |
| 648 |
DESCRIPTION |
| 649 |
"The total number of packets that higher-level |
| 650 |
protocols requested be transmitted, and which were |
| 651 |
addressed to a multicast address at this sub-layer, |
| 652 |
including those that were discarded or not sent. For |
| 653 |
a MAC layer protocol, this includes both Group and |
| 654 |
Functional addresses. |
| 655 |
|
| 656 |
Discontinuities in the value of this counter can occur |
| 657 |
at re-initialization of the management system, and at |
| 658 |
other times as indicated by the value of |
| 659 |
ifCounterDiscontinuityTime." |
| 660 |
::= { ifXEntry 4 } |
| 661 |
|
| 662 |
ifOutBroadcastPkts OBJECT-TYPE |
| 663 |
SYNTAX Counter32 |
| 664 |
MAX-ACCESS read-only |
| 665 |
STATUS current |
| 666 |
DESCRIPTION |
| 667 |
"The total number of packets that higher-level |
| 668 |
protocols requested be transmitted, and which were |
| 669 |
addressed to a broadcast address at this sub-layer, |
| 670 |
including those that were discarded or not sent. |
| 671 |
|
| 672 |
Discontinuities in the value of this counter can occur |
| 673 |
at re-initialization of the management system, and at |
| 674 |
other times as indicated by the value of |
| 675 |
ifCounterDiscontinuityTime." |
| 676 |
::= { ifXEntry 5 } |
| 677 |
|
| 678 |
-- |
| 679 |
-- High Capacity Counter objects. These objects are all |
| 680 |
-- 64 bit versions of the "basic" ifTable counters. These |
| 681 |
-- objects all have the same basic semantics as their 32-bit |
| 682 |
-- counterparts, however, their syntax has been extended |
| 683 |
-- to 64 bits. |
| 684 |
-- |
| 685 |
|
| 686 |
ifHCInOctets OBJECT-TYPE |
| 687 |
SYNTAX Counter64 |
| 688 |
MAX-ACCESS read-only |
| 689 |
STATUS current |
| 690 |
|
| 691 |
DESCRIPTION |
| 692 |
"The total number of octets received on the interface, |
| 693 |
including framing characters. This object is a 64-bit |
| 694 |
version of ifInOctets. |
| 695 |
|
| 696 |
Discontinuities in the value of this counter can occur |
| 697 |
at re-initialization of the management system, and at |
| 698 |
other times as indicated by the value of |
| 699 |
ifCounterDiscontinuityTime." |
| 700 |
::= { ifXEntry 6 } |
| 701 |
|
| 702 |
ifHCInUcastPkts OBJECT-TYPE |
| 703 |
SYNTAX Counter64 |
| 704 |
MAX-ACCESS read-only |
| 705 |
STATUS current |
| 706 |
DESCRIPTION |
| 707 |
"The number of packets, delivered by this sub-layer to |
| 708 |
a higher (sub-)layer, which were not addressed to a |
| 709 |
multicast or broadcast address at this sub-layer. |
| 710 |
This object is a 64-bit version of ifInUcastPkts. |
| 711 |
|
| 712 |
Discontinuities in the value of this counter can occur |
| 713 |
at re-initialization of the management system, and at |
| 714 |
other times as indicated by the value of |
| 715 |
ifCounterDiscontinuityTime." |
| 716 |
::= { ifXEntry 7 } |
| 717 |
|
| 718 |
ifHCInMulticastPkts OBJECT-TYPE |
| 719 |
SYNTAX Counter64 |
| 720 |
MAX-ACCESS read-only |
| 721 |
STATUS current |
| 722 |
DESCRIPTION |
| 723 |
"The number of packets, delivered by this sub-layer to |
| 724 |
a higher (sub-)layer, which were addressed to a |
| 725 |
multicast address at this sub-layer. For a MAC layer |
| 726 |
protocol, this includes both Group and Functional |
| 727 |
addresses. This object is a 64-bit version of |
| 728 |
ifInMulticastPkts. |
| 729 |
|
| 730 |
Discontinuities in the value of this counter can occur |
| 731 |
at re-initialization of the management system, and at |
| 732 |
other times as indicated by the value of |
| 733 |
ifCounterDiscontinuityTime." |
| 734 |
::= { ifXEntry 8 } |
| 735 |
|
| 736 |
|
| 737 |
ifHCInBroadcastPkts OBJECT-TYPE |
| 738 |
SYNTAX Counter64 |
| 739 |
MAX-ACCESS read-only |
| 740 |
STATUS current |
| 741 |
DESCRIPTION |
| 742 |
"The number of packets, delivered by this sub-layer to |
| 743 |
a higher (sub-)layer, which were addressed to a |
| 744 |
broadcast address at this sub-layer. This object is a |
| 745 |
64-bit version of ifInBroadcastPkts. |
| 746 |
|
| 747 |
Discontinuities in the value of this counter can occur |
| 748 |
at re-initialization of the management system, and at |
| 749 |
other times as indicated by the value of |
| 750 |
ifCounterDiscontinuityTime." |
| 751 |
::= { ifXEntry 9 } |
| 752 |
|
| 753 |
ifHCOutOctets OBJECT-TYPE |
| 754 |
SYNTAX Counter64 |
| 755 |
MAX-ACCESS read-only |
| 756 |
STATUS current |
| 757 |
DESCRIPTION |
| 758 |
"The total number of octets transmitted out of the |
| 759 |
interface, including framing characters. This object |
| 760 |
is a 64-bit version of ifOutOctets. |
| 761 |
|
| 762 |
Discontinuities in the value of this counter can occur |
| 763 |
at re-initialization of the management system, and at |
| 764 |
other times as indicated by the value of |
| 765 |
ifCounterDiscontinuityTime." |
| 766 |
::= { ifXEntry 10 } |
| 767 |
|
| 768 |
ifHCOutUcastPkts OBJECT-TYPE |
| 769 |
SYNTAX Counter64 |
| 770 |
MAX-ACCESS read-only |
| 771 |
STATUS current |
| 772 |
DESCRIPTION |
| 773 |
"The total number of packets that higher-level |
| 774 |
protocols requested be transmitted, and which were not |
| 775 |
addressed to a multicast or broadcast address at this |
| 776 |
sub-layer, including those that were discarded or not |
| 777 |
sent. This object is a 64-bit version of |
| 778 |
ifOutUcastPkts. |
| 779 |
|
| 780 |
Discontinuities in the value of this counter can occur |
| 781 |
at re-initialization of the management system, and at |
| 782 |
other times as indicated by the value of |
| 783 |
ifCounterDiscontinuityTime." |
| 784 |
::= { ifXEntry 11 } |
| 785 |
|
| 786 |
ifHCOutMulticastPkts OBJECT-TYPE |
| 787 |
SYNTAX Counter64 |
| 788 |
MAX-ACCESS read-only |
| 789 |
STATUS current |
| 790 |
DESCRIPTION |
| 791 |
"The total number of packets that higher-level |
| 792 |
protocols requested be transmitted, and which were |
| 793 |
addressed to a multicast address at this sub-layer, |
| 794 |
including those that were discarded or not sent. For |
| 795 |
a MAC layer protocol, this includes both Group and |
| 796 |
Functional addresses. This object is a 64-bit version |
| 797 |
of ifOutMulticastPkts. |
| 798 |
|
| 799 |
Discontinuities in the value of this counter can occur |
| 800 |
at re-initialization of the management system, and at |
| 801 |
other times as indicated by the value of |
| 802 |
ifCounterDiscontinuityTime." |
| 803 |
::= { ifXEntry 12 } |
| 804 |
|
| 805 |
ifHCOutBroadcastPkts OBJECT-TYPE |
| 806 |
SYNTAX Counter64 |
| 807 |
MAX-ACCESS read-only |
| 808 |
STATUS current |
| 809 |
DESCRIPTION |
| 810 |
"The total number of packets that higher-level |
| 811 |
protocols requested be transmitted, and which were |
| 812 |
addressed to a broadcast address at this sub-layer, |
| 813 |
including those that were discarded or not sent. This |
| 814 |
object is a 64-bit version of ifOutBroadcastPkts. |
| 815 |
|
| 816 |
Discontinuities in the value of this counter can occur |
| 817 |
at re-initialization of the management system, and at |
| 818 |
other times as indicated by the value of |
| 819 |
ifCounterDiscontinuityTime." |
| 820 |
::= { ifXEntry 13 } |
| 821 |
|
| 822 |
ifLinkUpDownTrapEnable OBJECT-TYPE |
| 823 |
SYNTAX INTEGER { enabled(1), disabled(2) } |
| 824 |
MAX-ACCESS read-write |
| 825 |
STATUS current |
| 826 |
DESCRIPTION |
| 827 |
|
| 828 |
"Indicates whether linkUp/linkDown traps should be |
| 829 |
generated for this interface. |
| 830 |
|
| 831 |
By default, this object should have the value |
| 832 |
enabled(1) for interfaces which do not operate on |
| 833 |
'top' of any other interface (as defined in the |
| 834 |
ifStackTable), and disabled(2) otherwise." |
| 835 |
::= { ifXEntry 14 } |
| 836 |
|
| 837 |
ifHighSpeed OBJECT-TYPE |
| 838 |
SYNTAX Gauge32 |
| 839 |
MAX-ACCESS read-only |
| 840 |
STATUS current |
| 841 |
DESCRIPTION |
| 842 |
"An estimate of the interface's current bandwidth in |
| 843 |
units of 1,000,000 bits per second. If this object |
| 844 |
reports a value of `n' then the speed of the interface |
| 845 |
is somewhere in the range of `n-500,000' to |
| 846 |
`n+499,999'. For interfaces which do not vary in |
| 847 |
bandwidth or for those where no accurate estimation |
| 848 |
can be made, this object should contain the nominal |
| 849 |
bandwidth. For a sub-layer which has no concept of |
| 850 |
bandwidth, this object should be zero." |
| 851 |
::= { ifXEntry 15 } |
| 852 |
|
| 853 |
ifPromiscuousMode OBJECT-TYPE |
| 854 |
SYNTAX TruthValue |
| 855 |
MAX-ACCESS read-write |
| 856 |
STATUS current |
| 857 |
DESCRIPTION |
| 858 |
"This object has a value of false(2) if this interface |
| 859 |
only accepts packets/frames that are addressed to this |
| 860 |
station. This object has a value of true(1) when the |
| 861 |
station accepts all packets/frames transmitted on the |
| 862 |
media. The value true(1) is only legal on certain |
| 863 |
types of media. If legal, setting this object to a |
| 864 |
value of true(1) may require the interface to be reset |
| 865 |
before becoming effective. |
| 866 |
|
| 867 |
The value of ifPromiscuousMode does not affect the |
| 868 |
reception of broadcast and multicast packets/frames by |
| 869 |
the interface." |
| 870 |
::= { ifXEntry 16 } |
| 871 |
|
| 872 |
ifConnectorPresent OBJECT-TYPE |
| 873 |
SYNTAX TruthValue |
| 874 |
MAX-ACCESS read-only |
| 875 |
STATUS current |
| 876 |
DESCRIPTION |
| 877 |
"This object has the value 'true(1)' if the interface |
| 878 |
sublayer has a physical connector and the value |
| 879 |
'false(2)' otherwise." |
| 880 |
::= { ifXEntry 17 } |
| 881 |
|
| 882 |
ifAlias OBJECT-TYPE |
| 883 |
SYNTAX DisplayString (SIZE(0..64)) |
| 884 |
MAX-ACCESS read-write |
| 885 |
STATUS current |
| 886 |
DESCRIPTION |
| 887 |
"This object is an 'alias' name for the interface as |
| 888 |
specified by a network manager, and provides a non- |
| 889 |
volatile 'handle' for the interface. |
| 890 |
|
| 891 |
On the first instantiation of an interface, the value |
| 892 |
of ifAlias associated with that interface is the |
| 893 |
zero-length string. As and when a value is written |
| 894 |
into an instance of ifAlias through a network |
| 895 |
management set operation, then the agent must retain |
| 896 |
the supplied value in the ifAlias instance associated |
| 897 |
with the same interface for as long as that interface |
| 898 |
remains instantiated, including across all re- |
| 899 |
initializations/reboots of the network management |
| 900 |
system, including those which result in a change of |
| 901 |
the interface's ifIndex value. |
| 902 |
|
| 903 |
An example of the value which a network manager might |
| 904 |
store in this object for a WAN interface is the |
| 905 |
(Telco's) circuit number/identifier of the interface. |
| 906 |
|
| 907 |
Some agents may support write-access only for |
| 908 |
interfaces having particular values of ifType. An |
| 909 |
agent which supports write access to this object is |
| 910 |
required to keep the value in non-volatile storage, |
| 911 |
but it may limit the length of new values depending on |
| 912 |
how much storage is already occupied by the current |
| 913 |
values for other interfaces." |
| 914 |
::= { ifXEntry 18 } |
| 915 |
|
| 916 |
ifCounterDiscontinuityTime OBJECT-TYPE |
| 917 |
SYNTAX TimeStamp |
| 918 |
MAX-ACCESS read-only |
| 919 |
STATUS current |
| 920 |
DESCRIPTION |
| 921 |
"The value of sysUpTime on the most recent occasion at |
| 922 |
which any one or more of this interface's counters |
| 923 |
suffered a discontinuity. The relevant counters are |
| 924 |
the specific instances associated with this interface |
| 925 |
of any Counter32 or Counter64 object contained in the |
| 926 |
ifTable or ifXTable. If no such discontinuities have |
| 927 |
occurred since the last re-initialization of the local |
| 928 |
management subsystem, then this object contains a zero |
| 929 |
value." |
| 930 |
::= { ifXEntry 19 } |
| 931 |
|
| 932 |
|
| 933 |
-- The Interface Stack Group |
| 934 |
-- |
| 935 |
-- Implementation of this group is mandatory for all systems |
| 936 |
-- |
| 937 |
|
| 938 |
ifStackTable OBJECT-TYPE |
| 939 |
SYNTAX SEQUENCE OF IfStackEntry |
| 940 |
MAX-ACCESS not-accessible |
| 941 |
STATUS current |
| 942 |
DESCRIPTION |
| 943 |
"The table containing information on the relationships |
| 944 |
between the multiple sub-layers of network interfaces. |
| 945 |
In particular, it contains information on which sub- |
| 946 |
layers run 'on top of' which other sub-layers, where |
| 947 |
each sub-layer corresponds to a conceptual row in the |
| 948 |
ifTable. For example, when the sub-layer with ifIndex |
| 949 |
value x runs over the sub-layer with ifIndex value y, |
| 950 |
then this table contains: |
| 951 |
|
| 952 |
ifStackStatus.x.y=active |
| 953 |
|
| 954 |
For each ifIndex value, I, which identifies an active |
| 955 |
interface, there are always at least two instantiated |
| 956 |
rows in this table associated with I. For one of |
| 957 |
these rows, I is the value of ifStackHigherLayer; for |
| 958 |
the other, I is the value of ifStackLowerLayer. (If I |
| 959 |
is not involved in multiplexing, then these are the |
| 960 |
only two rows associated with I.) |
| 961 |
|
| 962 |
For example, two rows exist even for an interface |
| 963 |
which has no others stacked on top or below it: |
| 964 |
|
| 965 |
ifStackStatus.0.x=active |
| 966 |
ifStackStatus.x.0=active " |
| 967 |
::= { ifMIBObjects 2 } |
| 968 |
|
| 969 |
|
| 970 |
ifStackEntry OBJECT-TYPE |
| 971 |
SYNTAX IfStackEntry |
| 972 |
MAX-ACCESS not-accessible |
| 973 |
STATUS current |
| 974 |
DESCRIPTION |
| 975 |
"Information on a particular relationship between two |
| 976 |
sub-layers, specifying that one sub-layer runs on |
| 977 |
'top' of the other sub-layer. Each sub-layer |
| 978 |
corresponds to a conceptual row in the ifTable." |
| 979 |
INDEX { ifStackHigherLayer, ifStackLowerLayer } |
| 980 |
::= { ifStackTable 1 } |
| 981 |
|
| 982 |
|
| 983 |
IfStackEntry ::= |
| 984 |
SEQUENCE { |
| 985 |
ifStackHigherLayer Integer32, |
| 986 |
ifStackLowerLayer Integer32, |
| 987 |
ifStackStatus RowStatus |
| 988 |
} |
| 989 |
|
| 990 |
ifStackHigherLayer OBJECT-TYPE |
| 991 |
SYNTAX Integer32 |
| 992 |
MAX-ACCESS not-accessible |
| 993 |
STATUS current |
| 994 |
DESCRIPTION |
| 995 |
"The value of ifIndex corresponding to the higher |
| 996 |
sub-layer of the relationship, i.e., the sub-layer |
| 997 |
which runs on 'top' of the sub-layer identified by the |
| 998 |
corresponding instance of ifStackLowerLayer. If there |
| 999 |
is no higher sub-layer (below the internetwork layer), |
| 1000 |
then this object has the value 0." |
| 1001 |
::= { ifStackEntry 1 } |
| 1002 |
|
| 1003 |
|
| 1004 |
ifStackLowerLayer OBJECT-TYPE |
| 1005 |
SYNTAX Integer32 |
| 1006 |
MAX-ACCESS not-accessible |
| 1007 |
STATUS current |
| 1008 |
DESCRIPTION |
| 1009 |
"The value of ifIndex corresponding to the lower sub- |
| 1010 |
layer of the relationship, i.e., the sub-layer which |
| 1011 |
runs 'below' the sub-layer identified by the |
| 1012 |
corresponding instance of ifStackHigherLayer. If |
| 1013 |
there is no lower sub-layer, then this object has the |
| 1014 |
value 0." |
| 1015 |
::= { ifStackEntry 2 } |
| 1016 |
|
| 1017 |
|
| 1018 |
ifStackStatus OBJECT-TYPE |
| 1019 |
SYNTAX RowStatus |
| 1020 |
MAX-ACCESS read-create |
| 1021 |
STATUS current |
| 1022 |
DESCRIPTION |
| 1023 |
"The status of the relationship between two sub- |
| 1024 |
layers. |
| 1025 |
|
| 1026 |
Changing the value of this object from 'active' to |
| 1027 |
'notInService' or 'destroy' will likely have |
| 1028 |
consequences up and down the interface stack. Thus, |
| 1029 |
write access to this object is likely to be |
| 1030 |
inappropriate for some types of interfaces, and many |
| 1031 |
implementations will choose not to support write- |
| 1032 |
access for any type of interface." |
| 1033 |
::= { ifStackEntry 3 } |
| 1034 |
|
| 1035 |
ifStackLastChange OBJECT-TYPE |
| 1036 |
SYNTAX TimeTicks |
| 1037 |
MAX-ACCESS read-only |
| 1038 |
STATUS current |
| 1039 |
DESCRIPTION |
| 1040 |
"The value of sysUpTime at the time of the last change |
| 1041 |
of the (whole) interface stack. A change of the |
| 1042 |
interface stack is defined to be any creation, |
| 1043 |
deletion, or change in value of any instance of |
| 1044 |
ifStackStatus. If the interface stack has been |
| 1045 |
unchanged since the last re-initialization of the |
| 1046 |
local network management subsystem, then this object |
| 1047 |
contains a zero value." |
| 1048 |
::= { ifMIBObjects 6 } |
| 1049 |
|
| 1050 |
|
| 1051 |
-- Generic Receive Address Table |
| 1052 |
-- |
| 1053 |
-- This group of objects is mandatory for all types of |
| 1054 |
-- interfaces which can receive packets/frames addressed to |
| 1055 |
-- more than one address. |
| 1056 |
-- |
| 1057 |
-- This table replaces the ifExtnsRcvAddr table. The main |
| 1058 |
-- difference is that this table makes use of the RowStatus |
| 1059 |
-- textual convention, while ifExtnsRcvAddr did not. |
| 1060 |
|
| 1061 |
ifRcvAddressTable OBJECT-TYPE |
| 1062 |
SYNTAX SEQUENCE OF IfRcvAddressEntry |
| 1063 |
MAX-ACCESS not-accessible |
| 1064 |
STATUS current |
| 1065 |
DESCRIPTION |
| 1066 |
"This table contains an entry for each address |
| 1067 |
(broadcast, multicast, or uni-cast) for which the |
| 1068 |
system will receive packets/frames on a particular |
| 1069 |
interface, except as follows: |
| 1070 |
|
| 1071 |
- for an interface operating in promiscuous mode, |
| 1072 |
entries are only required for those addresses for |
| 1073 |
which the system would receive frames were it not |
| 1074 |
operating in promiscuous mode. |
| 1075 |
|
| 1076 |
- for 802.5 functional addresses, only one entry is |
| 1077 |
required, for the address which has the functional |
| 1078 |
address bit ANDed with the bit mask of all functional |
| 1079 |
addresses for which the interface will accept frames. |
| 1080 |
|
| 1081 |
A system is normally able to use any unicast address |
| 1082 |
which corresponds to an entry in this table as a |
| 1083 |
source address." |
| 1084 |
::= { ifMIBObjects 4 } |
| 1085 |
|
| 1086 |
ifRcvAddressEntry OBJECT-TYPE |
| 1087 |
SYNTAX IfRcvAddressEntry |
| 1088 |
MAX-ACCESS not-accessible |
| 1089 |
STATUS current |
| 1090 |
DESCRIPTION |
| 1091 |
"A list of objects identifying an address for which |
| 1092 |
the system will accept packets/frames on the |
| 1093 |
particular interface identified by the index value |
| 1094 |
ifIndex." |
| 1095 |
INDEX { ifIndex, ifRcvAddressAddress } |
| 1096 |
::= { ifRcvAddressTable 1 } |
| 1097 |
|
| 1098 |
IfRcvAddressEntry ::= |
| 1099 |
SEQUENCE { |
| 1100 |
ifRcvAddressAddress PhysAddress, |
| 1101 |
ifRcvAddressStatus RowStatus, |
| 1102 |
ifRcvAddressType INTEGER |
| 1103 |
} |
| 1104 |
|
| 1105 |
ifRcvAddressAddress OBJECT-TYPE |
| 1106 |
SYNTAX PhysAddress |
| 1107 |
MAX-ACCESS not-accessible |
| 1108 |
STATUS current |
| 1109 |
DESCRIPTION |
| 1110 |
"An address for which the system will accept |
| 1111 |
packets/frames on this entry's interface." |
| 1112 |
|
| 1113 |
::= { ifRcvAddressEntry 1 } |
| 1114 |
|
| 1115 |
ifRcvAddressStatus OBJECT-TYPE |
| 1116 |
SYNTAX RowStatus |
| 1117 |
MAX-ACCESS read-create |
| 1118 |
STATUS current |
| 1119 |
DESCRIPTION |
| 1120 |
"This object is used to create and delete rows in the |
| 1121 |
ifRcvAddressTable." |
| 1122 |
|
| 1123 |
::= { ifRcvAddressEntry 2 } |
| 1124 |
|
| 1125 |
ifRcvAddressType OBJECT-TYPE |
| 1126 |
SYNTAX INTEGER { |
| 1127 |
other(1), |
| 1128 |
volatile(2), |
| 1129 |
nonVolatile(3) |
| 1130 |
} |
| 1131 |
|
| 1132 |
MAX-ACCESS read-create |
| 1133 |
STATUS current |
| 1134 |
DESCRIPTION |
| 1135 |
"This object has the value nonVolatile(3) for those |
| 1136 |
entries in the table which are valid and will not be |
| 1137 |
deleted by the next restart of the managed system. |
| 1138 |
Entries having the value volatile(2) are valid and |
| 1139 |
exist, but have not been saved, so that will not exist |
| 1140 |
after the next restart of the managed system. Entries |
| 1141 |
having the value other(1) are valid and exist but are |
| 1142 |
not classified as to whether they will continue to |
| 1143 |
exist after the next restart." |
| 1144 |
|
| 1145 |
DEFVAL { volatile } |
| 1146 |
::= { ifRcvAddressEntry 3 } |
| 1147 |
|
| 1148 |
-- definition of interface-related traps. |
| 1149 |
|
| 1150 |
linkDown NOTIFICATION-TYPE |
| 1151 |
OBJECTS { ifIndex, ifAdminStatus, ifOperStatus } |
| 1152 |
STATUS current |
| 1153 |
DESCRIPTION |
| 1154 |
"A linkDown trap signifies that the SNMPv2 entity, |
| 1155 |
acting in an agent role, has detected that the |
| 1156 |
ifOperStatus object for one of its communication links |
| 1157 |
is about to enter the down state from some other state |
| 1158 |
(but not from the notPresent state). This other state |
| 1159 |
is indicated by the included value of ifOperStatus." |
| 1160 |
::= { snmpTraps 3 } |
| 1161 |
|
| 1162 |
linkUp NOTIFICATION-TYPE |
| 1163 |
OBJECTS { ifIndex, ifAdminStatus, ifOperStatus } |
| 1164 |
STATUS current |
| 1165 |
DESCRIPTION |
| 1166 |
"A linkDown trap signifies that the SNMPv2 entity, |
| 1167 |
acting in an agent role, has detected that the |
| 1168 |
ifOperStatus object for one of its communication links |
| 1169 |
left the down state and transitioned into some other |
| 1170 |
state (but not into the notPresent state). This other |
| 1171 |
state is indicated by the included value of |
| 1172 |
ifOperStatus." |
| 1173 |
::= { snmpTraps 4 } |
| 1174 |
|
| 1175 |
-- conformance information |
| 1176 |
|
| 1177 |
ifConformance OBJECT IDENTIFIER ::= { ifMIB 2 } |
| 1178 |
|
| 1179 |
ifGroups OBJECT IDENTIFIER ::= { ifConformance 1 } |
| 1180 |
ifCompliances OBJECT IDENTIFIER ::= { ifConformance 2 } |
| 1181 |
|
| 1182 |
-- compliance statements |
| 1183 |
|
| 1184 |
ifCompliance2 MODULE-COMPLIANCE |
| 1185 |
STATUS current |
| 1186 |
DESCRIPTION |
| 1187 |
"The compliance statement for SNMPv2 entities which |
| 1188 |
have network interfaces." |
| 1189 |
|
| 1190 |
MODULE -- this module |
| 1191 |
MANDATORY-GROUPS { ifGeneralInformationGroup, ifStackGroup2, |
| 1192 |
ifCounterDiscontinuityGroup } |
| 1193 |
|
| 1194 |
GROUP ifFixedLengthGroup |
| 1195 |
DESCRIPTION |
| 1196 |
"This group is mandatory for all network interfaces |
| 1197 |
which are character-oriented or transmit data in |
| 1198 |
fixed-length transmission units." |
| 1199 |
|
| 1200 |
GROUP ifHCFixedLengthGroup |
| 1201 |
DESCRIPTION |
| 1202 |
"This group is mandatory only for those network |
| 1203 |
interfaces which are character-oriented or transmit |
| 1204 |
data in fixed-length transmission units, and for which |
| 1205 |
the value of the corresponding instance of ifSpeed is |
| 1206 |
greater than 20,000,000 bits/second." |
| 1207 |
|
| 1208 |
GROUP ifPacketGroup |
| 1209 |
DESCRIPTION |
| 1210 |
"This group is mandatory for all network interfaces |
| 1211 |
which are packet-oriented." |
| 1212 |
|
| 1213 |
GROUP ifHCPacketGroup |
| 1214 |
DESCRIPTION |
| 1215 |
"This group is mandatory only for those network |
| 1216 |
interfaces which are packet-oriented and for which the |
| 1217 |
value of the corresponding instance of ifSpeed is |
| 1218 |
greater than 650,000,000 bits/second." |
| 1219 |
|
| 1220 |
GROUP ifRcvAddressGroup |
| 1221 |
DESCRIPTION |
| 1222 |
"The applicability of this group MUST be defined by |
| 1223 |
the media-specific MIBs. Media-specific MIBs must |
| 1224 |
define the exact meaning, use, and semantics of the |
| 1225 |
addresses in this group." |
| 1226 |
OBJECT ifLinkUpDownTrapEnable |
| 1227 |
MIN-ACCESS read-only |
| 1228 |
DESCRIPTION |
| 1229 |
"Write access is not required." |
| 1230 |
|
| 1231 |
OBJECT ifPromiscuousMode |
| 1232 |
MIN-ACCESS read-only |
| 1233 |
DESCRIPTION |
| 1234 |
"Write access is not required." |
| 1235 |
|
| 1236 |
OBJECT ifStackStatus |
| 1237 |
SYNTAX INTEGER { active(1) } -- subset of RowStatus |
| 1238 |
MIN-ACCESS read-only |
| 1239 |
DESCRIPTION |
| 1240 |
"Write access is not required, and only one of the six |
| 1241 |
enumerated values for the RowStatus textual convention |
| 1242 |
need be supported, specifically: active(1)." |
| 1243 |
|
| 1244 |
OBJECT ifAdminStatus |
| 1245 |
SYNTAX INTEGER { up(1), down(2) } |
| 1246 |
MIN-ACCESS read-only |
| 1247 |
DESCRIPTION |
| 1248 |
"Write access is not required, nor is support for the |
| 1249 |
value testing(3)." |
| 1250 |
|
| 1251 |
OBJECT ifAlias |
| 1252 |
MIN-ACCESS read-only |
| 1253 |
DESCRIPTION |
| 1254 |
"Write access is not required." |
| 1255 |
|
| 1256 |
::= { ifCompliances 2 } |
| 1257 |
|
| 1258 |
-- units of conformance |
| 1259 |
|
| 1260 |
ifGeneralInformationGroup OBJECT-GROUP |
| 1261 |
OBJECTS { ifIndex, ifDescr, ifType, ifSpeed, ifPhysAddress, |
| 1262 |
ifAdminStatus, ifOperStatus, ifLastChange, |
| 1263 |
ifLinkUpDownTrapEnable, ifConnectorPresent, |
| 1264 |
ifHighSpeed, ifName, ifNumber, ifAlias, |
| 1265 |
ifTableLastChange } |
| 1266 |
STATUS current |
| 1267 |
DESCRIPTION |
| 1268 |
"A collection of objects providing information |
| 1269 |
applicable to all network interfaces." |
| 1270 |
::= { ifGroups 10 } |
| 1271 |
|
| 1272 |
-- the following five groups are mutually exclusive; at most |
| 1273 |
-- one of these groups is implemented for any interface |
| 1274 |
|
| 1275 |
ifFixedLengthGroup OBJECT-GROUP |
| 1276 |
OBJECTS { ifInOctets, ifOutOctets, ifInUnknownProtos, |
| 1277 |
ifInErrors, ifOutErrors } |
| 1278 |
STATUS current |
| 1279 |
DESCRIPTION |
| 1280 |
"A collection of objects providing information |
| 1281 |
specific to non-high speed (non-high speed interfaces |
| 1282 |
transmit and receive at speeds less than or equal to |
| 1283 |
20,000,000 bits/second) character-oriented or fixed- |
| 1284 |
length-transmission network interfaces." |
| 1285 |
::= { ifGroups 2 } |
| 1286 |
|
| 1287 |
ifHCFixedLengthGroup OBJECT-GROUP |
| 1288 |
OBJECTS { ifHCInOctets, ifHCOutOctets, |
| 1289 |
ifInOctets, ifOutOctets, ifInUnknownProtos, |
| 1290 |
ifInErrors, ifOutErrors } |
| 1291 |
STATUS current |
| 1292 |
DESCRIPTION |
| 1293 |
"A collection of objects providing information |
| 1294 |
specific to high speed (greater than 20,000,000 |
| 1295 |
bits/second) character-oriented or fixed-length- |
| 1296 |
transmission network interfaces." |
| 1297 |
::= { ifGroups 3 } |
| 1298 |
|
| 1299 |
ifPacketGroup OBJECT-GROUP |
| 1300 |
OBJECTS { ifInOctets, ifOutOctets, ifInUnknownProtos, |
| 1301 |
ifInErrors, ifOutErrors, |
| 1302 |
ifMtu, ifInUcastPkts, ifInMulticastPkts, |
| 1303 |
ifInBroadcastPkts, ifInDiscards, |
| 1304 |
ifOutUcastPkts, ifOutMulticastPkts, |
| 1305 |
ifOutBroadcastPkts, ifOutDiscards, |
| 1306 |
ifPromiscuousMode } |
| 1307 |
STATUS current |
| 1308 |
DESCRIPTION |
| 1309 |
"A collection of objects providing information |
| 1310 |
specific to non-high speed (non-high speed interfaces |
| 1311 |
transmit and receive at speeds less than or equal to |
| 1312 |
20,000,000 bits/second) packet-oriented network |
| 1313 |
interfaces." |
| 1314 |
::= { ifGroups 4 } |
| 1315 |
|
| 1316 |
ifHCPacketGroup OBJECT-GROUP |
| 1317 |
OBJECTS { ifHCInOctets, ifHCOutOctets, |
| 1318 |
ifInOctets, ifOutOctets, ifInUnknownProtos, |
| 1319 |
ifInErrors, ifOutErrors, |
| 1320 |
ifMtu, ifInUcastPkts, ifInMulticastPkts, |
| 1321 |
ifInBroadcastPkts, ifInDiscards, |
| 1322 |
ifOutUcastPkts, ifOutMulticastPkts, |
| 1323 |
ifOutBroadcastPkts, ifOutDiscards, |
| 1324 |
ifPromiscuousMode } |
| 1325 |
STATUS current |
| 1326 |
DESCRIPTION |
| 1327 |
"A collection of objects providing information |
| 1328 |
specific to high speed (greater than 20,000,000 |
| 1329 |
bits/second but less than or equal to 650,000,000 |
| 1330 |
bits/second) packet-oriented network interfaces." |
| 1331 |
::= { ifGroups 5 } |
| 1332 |
|
| 1333 |
ifVHCPacketGroup OBJECT-GROUP |
| 1334 |
OBJECTS { ifHCInUcastPkts, ifHCInMulticastPkts, |
| 1335 |
ifHCInBroadcastPkts, ifHCOutUcastPkts, |
| 1336 |
ifHCOutMulticastPkts, ifHCOutBroadcastPkts, |
| 1337 |
ifHCInOctets, ifHCOutOctets, |
| 1338 |
ifInOctets, ifOutOctets, ifInUnknownProtos, |
| 1339 |
ifInErrors, ifOutErrors, |
| 1340 |
ifMtu, ifInUcastPkts, ifInMulticastPkts, |
| 1341 |
ifInBroadcastPkts, ifInDiscards, |
| 1342 |
ifOutUcastPkts, ifOutMulticastPkts, |
| 1343 |
ifOutBroadcastPkts, ifOutDiscards, |
| 1344 |
ifPromiscuousMode } |
| 1345 |
STATUS current |
| 1346 |
DESCRIPTION |
| 1347 |
"A collection of objects providing information |
| 1348 |
specific to higher speed (greater than 650,000,000 |
| 1349 |
bits/second) packet-oriented network interfaces." |
| 1350 |
::= { ifGroups 6 } |
| 1351 |
|
| 1352 |
ifRcvAddressGroup OBJECT-GROUP |
| 1353 |
OBJECTS { ifRcvAddressStatus, ifRcvAddressType } |
| 1354 |
STATUS current |
| 1355 |
DESCRIPTION |
| 1356 |
"A collection of objects providing information on the |
| 1357 |
multiple addresses which an interface receives." |
| 1358 |
::= { ifGroups 7 } |
| 1359 |
|
| 1360 |
ifStackGroup2 OBJECT-GROUP |
| 1361 |
OBJECTS { ifStackStatus, ifStackLastChange } |
| 1362 |
STATUS current |
| 1363 |
DESCRIPTION |
| 1364 |
"A collection of objects providing information on the |
| 1365 |
layering of MIB-II interfaces." |
| 1366 |
::= { ifGroups 11 } |
| 1367 |
|
| 1368 |
ifCounterDiscontinuityGroup OBJECT-GROUP |
| 1369 |
OBJECTS { ifCounterDiscontinuityTime } |
| 1370 |
STATUS current |
| 1371 |
DESCRIPTION |
| 1372 |
"A collection of objects providing information |
| 1373 |
specific to interface counter discontinuities." |
| 1374 |
::= { ifGroups 13 } |
| 1375 |
|
| 1376 |
-- Deprecated Definitions - Objects |
| 1377 |
|
| 1378 |
|
| 1379 |
-- |
| 1380 |
-- The Interface Test Table |
| 1381 |
-- |
| 1382 |
-- This group of objects is optional. However, a media-specific |
| 1383 |
-- MIB may make implementation of this group mandatory. |
| 1384 |
-- |
| 1385 |
-- This table replaces the ifExtnsTestTable |
| 1386 |
-- |
| 1387 |
|
| 1388 |
ifTestTable OBJECT-TYPE |
| 1389 |
SYNTAX SEQUENCE OF IfTestEntry |
| 1390 |
MAX-ACCESS not-accessible |
| 1391 |
STATUS deprecated |
| 1392 |
DESCRIPTION |
| 1393 |
"This table contains one entry per interface. It |
| 1394 |
defines objects which allow a network manager to |
| 1395 |
instruct an agent to test an interface for various |
| 1396 |
faults. Tests for an interface are defined in the |
| 1397 |
media-specific MIB for that interface. After invoking |
| 1398 |
a test, the object ifTestResult can be read to |
| 1399 |
determine the outcome. If an agent can not perform |
| 1400 |
the test, ifTestResult is set to so indicate. The |
| 1401 |
object ifTestCode can be used to provide further |
| 1402 |
test-specific or interface-specific (or even |
| 1403 |
enterprise-specific) information concerning the |
| 1404 |
outcome of the test. Only one test can be in progress |
| 1405 |
on each interface at any one time. If one test is in |
| 1406 |
progress when another test is invoked, the second test |
| 1407 |
is rejected. Some agents may reject a test when a |
| 1408 |
prior test is active on another interface. |
| 1409 |
|
| 1410 |
Before starting a test, a manager-station must first |
| 1411 |
obtain 'ownership' of the entry in the ifTestTable for |
| 1412 |
the interface to be tested. This is accomplished with |
| 1413 |
the ifTestId and ifTestStatus objects as follows: |
| 1414 |
|
| 1415 |
try_again: |
| 1416 |
get (ifTestId, ifTestStatus) |
| 1417 |
while (ifTestStatus != notInUse) |
| 1418 |
/* |
| 1419 |
* Loop while a test is running or some other |
| 1420 |
* manager is configuring a test. |
| 1421 |
*/ |
| 1422 |
short delay |
| 1423 |
get (ifTestId, ifTestStatus) |
| 1424 |
} |
| 1425 |
|
| 1426 |
/* |
| 1427 |
* Is not being used right now -- let's compete |
| 1428 |
* to see who gets it. |
| 1429 |
*/ |
| 1430 |
lock_value = ifTestId |
| 1431 |
|
| 1432 |
if ( set(ifTestId = lock_value, ifTestStatus = inUse, |
| 1433 |
ifTestOwner = 'my-IP-address') == FAILURE) |
| 1434 |
/* |
| 1435 |
* Another manager got the ifTestEntry -- go |
| 1436 |
* try again |
| 1437 |
*/ |
| 1438 |
goto try_again; |
| 1439 |
|
| 1440 |
/* |
| 1441 |
* I have the lock |
| 1442 |
*/ |
| 1443 |
set up any test parameters. |
| 1444 |
|
| 1445 |
/* |
| 1446 |
* This starts the test |
| 1447 |
*/ |
| 1448 |
set(ifTestType = test_to_run); |
| 1449 |
|
| 1450 |
wait for test completion by polling ifTestResult |
| 1451 |
|
| 1452 |
when test completes, agent sets ifTestResult |
| 1453 |
agent also sets ifTestStatus = 'notInUse' |
| 1454 |
|
| 1455 |
retrieve any additional test results, and ifTestId |
| 1456 |
|
| 1457 |
if (ifTestId == lock_value+1) results are valid |
| 1458 |
|
| 1459 |
A manager station first retrieves the value of the |
| 1460 |
appropriate ifTestId and ifTestStatus objects, |
| 1461 |
periodically repeating the retrieval if necessary, |
| 1462 |
until the value of ifTestStatus is 'notInUse'. The |
| 1463 |
manager station then tries to set the same ifTestId |
| 1464 |
object to the value it just retrieved, the same |
| 1465 |
ifTestStatus object to 'inUse', and the corresponding |
| 1466 |
ifTestOwner object to a value indicating itself. If |
| 1467 |
the set operation succeeds then the manager has |
| 1468 |
obtained ownership of the ifTestEntry, and the value of |
| 1469 |
the ifTestId object is incremented by the agent (per |
| 1470 |
the semantics of TestAndIncr). Failure of the set |
| 1471 |
operation indicates that some other manager has |
| 1472 |
obtained ownership of the ifTestEntry. |
| 1473 |
|
| 1474 |
Once ownership is obtained, any test parameters can be |
| 1475 |
setup, and then the test is initiated by setting |
| 1476 |
ifTestType. On completion of the test, the agent sets |
| 1477 |
ifTestStatus to 'notInUse'. Once this occurs, the |
| 1478 |
manager can retrieve the results. In the (rare) event |
| 1479 |
that the invocation of tests by two network managers |
| 1480 |
were to overlap, then there would be a possibility that |
| 1481 |
the first test's results might be overwritten by the |
| 1482 |
second test's results prior to the first results being |
| 1483 |
read. This unlikely circumstance can be detected by a |
| 1484 |
network manager retrieving ifTestId at the same time as |
| 1485 |
retrieving the test results, and ensuring that the |
| 1486 |
results are for the desired request. |
| 1487 |
|
| 1488 |
If ifTestType is not set within an abnormally long |
| 1489 |
period of time after ownership is obtained, the agent |
| 1490 |
should time-out the manager, and reset the value of the |
| 1491 |
ifTestStatus object back to 'notInUse'. It is |
| 1492 |
suggested that this time-out period be 5 minutes. |
| 1493 |
|
| 1494 |
In general, a management station must not retransmit a |
| 1495 |
request to invoke a test for which it does not receive |
| 1496 |
a response; instead, it properly inspects an agent's |
| 1497 |
MIB to determine if the invocation was successful. |
| 1498 |
Only if the invocation was unsuccessful, is the |
| 1499 |
invocation request retransmitted. |
| 1500 |
|
| 1501 |
Some tests may require the interface to be taken off- |
| 1502 |
line in order to execute them, or may even require the |
| 1503 |
agent to reboot after completion of the test. In these |
| 1504 |
circumstances, communication with the management |
| 1505 |
station invoking the test may be lost until after |
| 1506 |
completion of the test. An agent is not required to |
| 1507 |
support such tests. However, if such tests are |
| 1508 |
supported, then the agent should make every effort to |
| 1509 |
transmit a response to the request which invoked the |
| 1510 |
test prior to losing communication. When the agent is |
| 1511 |
restored to normal service, the results of the test are |
| 1512 |
properly made available in the appropriate objects. |
| 1513 |
Note that this requires that the ifIndex value assigned |
| 1514 |
to an interface must be unchanged even if the test |
| 1515 |
causes a reboot. An agent must reject any test for |
| 1516 |
which it cannot, perhaps due to resource constraints, |
| 1517 |
make available at least the minimum amount of |
| 1518 |
information after that test completes." |
| 1519 |
::= { ifMIBObjects 3 } |
| 1520 |
|
| 1521 |
ifTestEntry OBJECT-TYPE |
| 1522 |
SYNTAX IfTestEntry |
| 1523 |
MAX-ACCESS not-accessible |
| 1524 |
STATUS deprecated |
| 1525 |
DESCRIPTION |
| 1526 |
"An entry containing objects for invoking tests on an |
| 1527 |
interface." |
| 1528 |
AUGMENTS { ifEntry } |
| 1529 |
::= { ifTestTable 1 } |
| 1530 |
|
| 1531 |
IfTestEntry ::= |
| 1532 |
SEQUENCE { |
| 1533 |
ifTestId TestAndIncr, |
| 1534 |
ifTestStatus INTEGER, |
| 1535 |
ifTestType AutonomousType, |
| 1536 |
ifTestResult INTEGER, |
| 1537 |
ifTestCode OBJECT IDENTIFIER, |
| 1538 |
ifTestOwner OwnerString |
| 1539 |
} |
| 1540 |
|
| 1541 |
ifTestId OBJECT-TYPE |
| 1542 |
SYNTAX TestAndIncr |
| 1543 |
MAX-ACCESS read-write |
| 1544 |
STATUS deprecated |
| 1545 |
DESCRIPTION |
| 1546 |
"This object identifies the current invocation of the |
| 1547 |
interface's test." |
| 1548 |
::= { ifTestEntry 1 } |
| 1549 |
|
| 1550 |
ifTestStatus OBJECT-TYPE |
| 1551 |
SYNTAX INTEGER { notInUse(1), inUse(2) } |
| 1552 |
MAX-ACCESS read-write |
| 1553 |
STATUS deprecated |
| 1554 |
DESCRIPTION |
| 1555 |
"This object indicates whether or not some manager |
| 1556 |
currently has the necessary 'ownership' required to |
| 1557 |
invoke a test on this interface. A write to this |
| 1558 |
object is only successful when it changes its value |
| 1559 |
from 'notInUse(1)' to 'inUse(2)'. After completion of |
| 1560 |
a test, the agent resets the value back to |
| 1561 |
'notInUse(1)'." |
| 1562 |
::= { ifTestEntry 2 } |
| 1563 |
|
| 1564 |
ifTestType OBJECT-TYPE |
| 1565 |
SYNTAX AutonomousType |
| 1566 |
MAX-ACCESS read-write |
| 1567 |
STATUS deprecated |
| 1568 |
DESCRIPTION |
| 1569 |
"A control variable used to start and stop operator- |
| 1570 |
initiated interface tests. Most OBJECT IDENTIFIER |
| 1571 |
values assigned to tests are defined elsewhere, in |
| 1572 |
association with specific types of interface. |
| 1573 |
However, this document assigns a value for a full- |
| 1574 |
duplex loopback test, and defines the special meanings |
| 1575 |
of the subject identifier: |
| 1576 |
|
| 1577 |
noTest OBJECT IDENTIFIER ::= { 0 0 } |
| 1578 |
|
| 1579 |
When the value noTest is written to this object, no |
| 1580 |
action is taken unless a test is in progress, in which |
| 1581 |
case the test is aborted. Writing any other value to |
| 1582 |
this object is only valid when no test is currently in |
| 1583 |
progress, in which case the indicated test is |
| 1584 |
initiated. |
| 1585 |
|
| 1586 |
When read, this object always returns the most recent |
| 1587 |
value that ifTestType was set to. If it has not been |
| 1588 |
set since the last initialization of the network |
| 1589 |
management subsystem on the agent, a value of noTest |
| 1590 |
is returned." |
| 1591 |
::= { ifTestEntry 3 } |
| 1592 |
|
| 1593 |
ifTestResult OBJECT-TYPE |
| 1594 |
SYNTAX INTEGER { |
| 1595 |
none(1), -- no test yet requested |
| 1596 |
success(2), |
| 1597 |
inProgress(3), |
| 1598 |
notSupported(4), |
| 1599 |
unAbleToRun(5), -- due to state of system |
| 1600 |
aborted(6), |
| 1601 |
failed(7) |
| 1602 |
} |
| 1603 |
MAX-ACCESS read-only |
| 1604 |
STATUS deprecated |
| 1605 |
DESCRIPTION |
| 1606 |
"This object contains the result of the most recently |
| 1607 |
requested test, or the value none(1) if no tests have |
| 1608 |
been requested since the last reset. Note that this |
| 1609 |
facility provides no provision for saving the results |
| 1610 |
of one test when starting another, as could be |
| 1611 |
required if used by multiple managers concurrently." |
| 1612 |
::= { ifTestEntry 4 } |
| 1613 |
|
| 1614 |
ifTestCode OBJECT-TYPE |
| 1615 |
SYNTAX OBJECT IDENTIFIER |
| 1616 |
MAX-ACCESS read-only |
| 1617 |
STATUS deprecated |
| 1618 |
DESCRIPTION |
| 1619 |
"This object contains a code which contains more |
| 1620 |
specific information on the test result, for example |
| 1621 |
an error-code after a failed test. Error codes and |
| 1622 |
other values this object may take are specific to the |
| 1623 |
type of interface and/or test. The value may have the |
| 1624 |
semantics of either the AutonomousType or |
| 1625 |
InstancePointer textual conventions as defined in RFC |
| 1626 |
1903. The identifier: |
| 1627 |
|
| 1628 |
testCodeUnknown OBJECT IDENTIFIER ::= { 0 0 } |
| 1629 |
|
| 1630 |
is defined for use if no additional result code is |
| 1631 |
available." |
| 1632 |
::= { ifTestEntry 5 } |
| 1633 |
|
| 1634 |
ifTestOwner OBJECT-TYPE |
| 1635 |
SYNTAX OwnerString |
| 1636 |
MAX-ACCESS read-write |
| 1637 |
STATUS deprecated |
| 1638 |
DESCRIPTION |
| 1639 |
"The entity which currently has the 'ownership' |
| 1640 |
required to invoke a test on this interface." |
| 1641 |
::= { ifTestEntry 6 } |
| 1642 |
|
| 1643 |
-- Deprecated Definitions - Groups |
| 1644 |
|
| 1645 |
|
| 1646 |
ifGeneralGroup OBJECT-GROUP |
| 1647 |
OBJECTS { ifDescr, ifType, ifSpeed, ifPhysAddress, |
| 1648 |
ifAdminStatus, ifOperStatus, ifLastChange, |
| 1649 |
ifLinkUpDownTrapEnable, ifConnectorPresent, |
| 1650 |
ifHighSpeed, ifName } |
| 1651 |
STATUS deprecated |
| 1652 |
DESCRIPTION |
| 1653 |
"A collection of objects deprecated in favour of |
| 1654 |
ifGeneralInformationGroup." |
| 1655 |
::= { ifGroups 1 } |
| 1656 |
|
| 1657 |
|
| 1658 |
ifTestGroup OBJECT-GROUP |
| 1659 |
OBJECTS { ifTestId, ifTestStatus, ifTestType, |
| 1660 |
ifTestResult, ifTestCode, ifTestOwner } |
| 1661 |
STATUS deprecated |
| 1662 |
DESCRIPTION |
| 1663 |
"A collection of objects providing the ability to |
| 1664 |
invoke tests on an interface." |
| 1665 |
::= { ifGroups 8 } |
| 1666 |
|
| 1667 |
|
| 1668 |
ifStackGroup OBJECT-GROUP |
| 1669 |
OBJECTS { ifStackStatus } |
| 1670 |
STATUS deprecated |
| 1671 |
DESCRIPTION |
| 1672 |
"The previous collection of objects providing |
| 1673 |
information on the layering of MIB-II interfaces." |
| 1674 |
::= { ifGroups 9 } |
| 1675 |
|
| 1676 |
|
| 1677 |
ifOldObjectsGroup OBJECT-GROUP |
| 1678 |
OBJECTS { ifInNUcastPkts, ifOutNUcastPkts, |
| 1679 |
ifOutQLen, ifSpecific } |
| 1680 |
STATUS deprecated |
| 1681 |
DESCRIPTION |
| 1682 |
"The collection of objects deprecated from the |
| 1683 |
original MIB-II interfaces group." |
| 1684 |
::= { ifGroups 12 } |
| 1685 |
|
| 1686 |
|
| 1687 |
-- Deprecated Definitions - Compliance |
| 1688 |
|
| 1689 |
ifCompliance MODULE-COMPLIANCE |
| 1690 |
STATUS deprecated |
| 1691 |
DESCRIPTION |
| 1692 |
"The previous compliance statement for SNMPv2 entities |
| 1693 |
which have network interfaces." |
| 1694 |
|
| 1695 |
MODULE -- this module |
| 1696 |
MANDATORY-GROUPS { ifGeneralGroup, ifStackGroup } |
| 1697 |
|
| 1698 |
GROUP ifFixedLengthGroup |
| 1699 |
DESCRIPTION |
| 1700 |
"This group is mandatory for all network interfaces |
| 1701 |
which are character-oriented or transmit data in |
| 1702 |
fixed-length transmission units." |
| 1703 |
|
| 1704 |
GROUP ifHCFixedLengthGroup |
| 1705 |
DESCRIPTION |
| 1706 |
"This group is mandatory only for those network |
| 1707 |
interfaces which are character-oriented or transmit |
| 1708 |
data in fixed-length transmission units, and for which |
| 1709 |
the value of the corresponding instance of ifSpeed is |
| 1710 |
greater than 20,000,000 bits/second." |
| 1711 |
|
| 1712 |
GROUP ifPacketGroup |
| 1713 |
DESCRIPTION |
| 1714 |
"This group is mandatory for all network interfaces |
| 1715 |
which are packet-oriented." |
| 1716 |
|
| 1717 |
GROUP ifHCPacketGroup |
| 1718 |
DESCRIPTION |
| 1719 |
"This group is mandatory only for those network |
| 1720 |
interfaces which are packet-oriented and for which the |
| 1721 |
value of the corresponding instance of ifSpeed is |
| 1722 |
greater than 650,000,000 bits/second." |
| 1723 |
|
| 1724 |
GROUP ifTestGroup |
| 1725 |
DESCRIPTION |
| 1726 |
"This group is optional. Media-specific MIBs which |
| 1727 |
require interface tests are strongly encouraged to use |
| 1728 |
this group for invoking tests and reporting results. |
| 1729 |
A medium specific MIB which has mandatory tests may |
| 1730 |
make implementation of this group mandatory." |
| 1731 |
|
| 1732 |
GROUP ifRcvAddressGroup |
| 1733 |
DESCRIPTION |
| 1734 |
"The applicability of this group MUST be defined by |
| 1735 |
the media-specific MIBs. Media-specific MIBs must |
| 1736 |
define the exact meaning, use, and semantics of the |
| 1737 |
addresses in this group." |
| 1738 |
|
| 1739 |
OBJECT ifLinkUpDownTrapEnable |
| 1740 |
MIN-ACCESS read-only |
| 1741 |
DESCRIPTION |
| 1742 |
"Write access is not required." |
| 1743 |
|
| 1744 |
OBJECT ifPromiscuousMode |
| 1745 |
MIN-ACCESS read-only |
| 1746 |
DESCRIPTION |
| 1747 |
"Write access is not required." |
| 1748 |
|
| 1749 |
OBJECT ifStackStatus |
| 1750 |
SYNTAX INTEGER { active(1) } -- subset of RowStatus |
| 1751 |
MIN-ACCESS read-only |
| 1752 |
DESCRIPTION |
| 1753 |
"Write access is not required, and only one of the six |
| 1754 |
enumerated values for the RowStatus textual convention |
| 1755 |
need be supported, specifically: active(1)." |
| 1756 |
OBJECT ifAdminStatus |
| 1757 |
SYNTAX INTEGER { up(1), down(2) } |
| 1758 |
MIN-ACCESS read-only |
| 1759 |
DESCRIPTION |
| 1760 |
"Write access is not required, nor is support for the |
| 1761 |
value testing(3)." |
| 1762 |
::= { ifCompliances 1 } |
| 1763 |
|
| 1764 |
END |