Debian Codegraph @

scanners/epson_3490

raw
1 Usage: scanimage [OPTION]...
2
3 Start image acquisition on a scanner device and write PNM image data to
4 standard output.
5
6 -d, --device-name=DEVICE use a given scanner device (e.g. hp:/dev/scanner)
7 --format=pnm|tiff file format of output file
8 -i, --icc-profile=PROFILE include this ICC profile into TIFF file
9 -L, --list-devices show available scanner devices
10 -f, --formatted-device-list=FORMAT similar to -L, but the FORMAT of the output
11 can be specified: %d (device name), %v (vendor),
12 %m (model), %t (type), and %i (index number)
13 -b, --batch[=FORMAT] working in batch mode, FORMAT is `out%d.pnm' or
14 `out%d.tif' by default depending on --format
15 --batch-start=# page number to start naming files with
16 --batch-count=# how many pages to scan in batch mode
17 --batch-increment=# increase number in filename by an amount of #
18 --batch-double increment page number by two for 2sided originals
19 being scanned in a single sided scanner
20 --batch-prompt ask for pressing a key before scanning a page
21 --accept-md5-only only accept authorization requests using md5
22 -p, --progress print progress messages
23 -n, --dont-scan only set options, don't actually scan
24 -T, --test test backend thoroughly
25 -h, --help display this help message and exit
26 -v, --verbose give even more status messages
27 -B, --buffer-size change default input buffersize
28 -V, --version print version information
29
30 Options specific to device `snapscan:libusb:005:007':
31 Scan Mode:
32 --resolution auto||50|150|200|240|266|300|350|360|400|600|720|800|1200|1600|3200dpi [300]
33 Sets the resolution of the scanned image.
34 --preview[=(auto|yes|no)] [no]
35 Request a preview-quality scan.
36 --mode auto|Color|Gray|Lineart [Color]
37 Selects the scan mode (e.g., lineart, monochrome, or color).
38 --preview-mode auto|Auto|Color|Gray|Lineart [Auto]
39 Select the mode for previews. Greyscale previews usually give the best
40 combination of speed and detail.
41 --high-quality[=(auto|yes|no)] [no]
42 Highest quality but lower speed
43 --source auto|Flatbed|Transparency Adapter [Flatbed]
44 Selects the scan source (such as a document-feeder).
45 Geometry:
46 -l auto|0..216mm [0]
47 Top-left x position of scan area.
48 -t auto|0..297mm [0]
49 Top-left y position of scan area.
50 -x auto|0..216mm [216]
51 Width of scan-area.
52 -y auto|0..297mm [297]
53 Height of scan-area.
54 --predef-window None|6x4 (inch)|8x10 (inch)|8.5x11 (inch) [None]
55 Provides standard scanning areas for photographs, printed pages and
56 the like.
57 Enhancement:
58 --depth 8|16bit [8]
59 Number of bits per sample, typical values are 1 for "line-art" and 8
60 for multibit scans.
61 --quality-cal[=(yes|no)] [yes]
62 Do a quality white-calibration
63 --halftoning[=(yes|no)] [inactive]
64 Selects whether the acquired image should be halftoned (dithered).
65 --halftone-pattern DispersedDot8x8|DispersedDot16x16 [inactive]
66 Defines the halftoning (dithering) pattern for scanning halftoned
67 images.
68 --custom-gamma[=(yes|no)] [no]
69 Determines whether a builtin or a custom gamma-table should be used.
70 --analog-gamma-bind[=(yes|no)] [no]
71 In RGB-mode use same values for each color
72 --analog-gamma 0..4 [inactive]
73 Analog gamma-correction
74 --analog-gamma-r 0..4 [1.79999]
75 Analog gamma-correction for red
76 --analog-gamma-g 0..4 [1.79999]
77 Analog gamma-correction for green
78 --analog-gamma-b 0..4 [1.79999]
79 Analog gamma-correction for blue
80 --gamma-table 0..65535,... (in steps of 1) [inactive]
81 Gamma-correction table. In color mode this option equally affects the
82 red, green, and blue channels simultaneously (i.e., it is an intensity
83 gamma table).
84 --red-gamma-table 0..65535,... (in steps of 1) [inactive]
85 Gamma-correction table for the red band.
86 --green-gamma-table 0..65535,... (in steps of 1) [inactive]
87 Gamma-correction table for the green band.
88 --blue-gamma-table 0..65535,... (in steps of 1) [inactive]
89 Gamma-correction table for the blue band.
90 --negative[=(auto|yes|no)] [inactive]
91 Swap black and white
92 --threshold 0..100% (in steps of 1) [inactive]
93 Select minimum-brightness to get a white point
94 --brightness -400..400% (in steps of 1) [0]
95 Controls the brightness of the acquired image.
96 --contrast -100..400% (in steps of 1) [0]
97 Controls the contrast of the acquired image.
98 Advanced:
99 --rgb-lpr auto|1..50 (in steps of 1) [4]
100 Number of scan lines to request in a SCSI read. Changing this
101 parameter allows you to tune the speed at which data is read from the
102 scanner during scans. If this is set too low, the scanner will have to
103 stop periodically in the middle of a scan; if it's set too high,
104 X-based frontends may stop responding to X events and your system could
105 bog down.
106 --gs-lpr auto|1..50 (in steps of 1) [inactive]
107 Number of scan lines to request in a SCSI read. Changing this
108 parameter allows you to tune the speed at which data is read from the
109 scanner during scans. If this is set too low, the scanner will have to
110 stop periodically in the middle of a scan; if it's set too high,
111 X-based frontends may stop responding to X events and your system could
112 bog down.
113
114 Type ``scanimage --help -d DEVICE'' to get list of all options for DEVICE.
115