1 #!/bin/sh
2 #
3 # External STONITH module for APC Switched Rack PDU
4 #
5 # Copyright (c) 2008 Sergey Maznichenko <[email protected]> <[email protected]>
6 # Version 1.2
7 #
8 # See http://www.it-consultant.su/rackpdu
9 # for additional information
10 #
11 # This program is free software; you can redistribute it and/or modify
12 # it under the terms of version 2 of the GNU General Public License as
13 # published by the Free Software Foundation.
14 #
15 # This program is distributed in the hope that it would be useful, but
16 # WITHOUT ANY WARRANTY; without even the implied warranty of
17 # MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.
18 #
19 # Further, this software is distributed without any warranty that it is
20 # free of the rightful claim of any third person regarding infringement
21 # or the like. Any license provided herein, whether implied or
22 # otherwise, applies only to this software file. Patent licenses, if
23 # any, provided herein do not apply to combinations of this program with
24 # other software, or any other product whatsoever.
25 #
26 # You should have received a copy of the GNU General Public License
27 # along with this program; if not, write the Free Software Foundation,
28 # Inc., 59 Temple Place - Suite 330, Boston MA 02111-1307, USA.
29 #
30
31 SWITCH_ON="1"
32 SWITCH_OFF="2"
33 SWITCH_RESET="3"
34
35 DEFAULT_NAMES_OID=".1.3.6.1.4.1.318.1.1.12.3.3.1.1.2"
36 DEFAULT_COMMAND_OID=".1.3.6.1.4.1.318.1.1.12.3.3.1.1.4"
37
38 if [ -z "$oid" ]; then
39 oid=$DEFAULT_COMMAND_OID
40 fi
41
42 if [ -z "$names_oid" ]; then
43 names_oid=$DEFAULT_NAMES_OID
44 fi
45
46 if [ -z "$outlet_config" ]; then
47 outlet_config="none"
48 fi
49
50 GetOutletNumber() {
51 local nodename=$1
52
53 if [ "$outlet_config" != "none" ]; then
54 # Get outlet number from file
55
56 if [ -f "$outlet_config" ]; then
57 local outlet_num=`grep $nodename $outlet_config | tr -d ' ' | cut -f2 -d'='`
58 if [ -z "$outlet_num" ]; then
59 ha_log.sh err "Outlet number not found for node $nodename. Check configuration file $outlet_config"
60 return 0
61 fi
62 return $outlet_num
63 else
64 ha_log.sh err "File $outlet_config not found."
65 return 0
66 fi
67 else
68 # Get outlet number from device
69
70 local outlet_num=1
71 local snmp_result
72 snmp_result=`snmpwalk -v1 -c $community $pduip $names_oid 2>&1`
73 if [ $? -ne 0 ]; then
74 ha_log.sh err "snmpwalk $community $pduip $names_oid failed. Result: $snmp_result"
75 return 0
76 fi
77
78 local names
79 names=`echo "$snmp_result" | cut -f2 -d'"' | tr ' ' '_' | tr '\012' ' '`
80 for name in $names; do
81 if [ "$name" != "$nodename" ]; then
82 local outlet_num=`expr $outlet_num + 1`
83 continue
84 fi
85
86 return $outlet_num
87 done
88
89 ha_log.sh err "Outlet number not found for node $nodename. Result: $snmp_result"
90 return 0
91 fi
92 }
93
94 SendCommand() {
95
96 local host=$1
97 local command=$2
98
99 GetOutletNumber $host
100 local outlet=$?
101
102 if [ $outlet -gt 0 ]; then
103 local set_result
104 set_result=`snmpset -v1 -c $community $pduip $oid.$outlet i $command 2>&1`
105 if [ $? -ne 0 ]; then
106 ha_log.sh err "Write SNMP to $pduip value $oid.$outlet=$command failed. Result: $set_result"
107 return 1
108 fi
109 if echo "$set_result" | grep -qs "Timeout"; then
110 ha_log.sh err "Write SNMP to $pduip value $oid.$outlet=$command timed out. Result: $set_result"
111 return 1
112 fi
113 return 0
114 else
115 return 1
116 fi
117 }
118
119 hostlist=`echo $hostlist | tr ',' ' '`
120 incommand=$1
121 innode=$2
122
123 case $incommand in
124 gethosts)
125 if [ "$hostlist" = "AUTO" ]; then
126 snmp_result=`snmpwalk -v1 -c $community $pduip $names_oid 2>&1`
127 if [ $? -ne 0 ]; then
128 ha_log.sh err "snmpwalk $community $pduip $names_oid failed. Result: $snmp_result"
129 exit 1
130 fi
131 if echo "$snmp_result" | grep -qs "Timeout"; then
132 ha_log.sh err "snmpwalk $community $pduip $names_oid timed out. Result: $snmp_result"
133 exit 1
134 else
135 hostlist=`echo "$snmp_result" | cut -f2 -d'"' | tr ' ' '_' | tr '\012' ' '`
136 fi
137 fi
138
139 for h in $hostlist ; do
140 echo $h
141 done
142
143 exit 0
144 ;;
145 on)
146 if
147 SendCommand $innode $SWITCH_ON
148 then
149 exit 0
150 else
151 exit 1
152 fi
153 ;;
154 off)
155 if
156 SendCommand $innode $SWITCH_OFF
157 then
158 exit 0
159 else
160 exit 1
161 fi
162 ;;
163 reset)
164 if
165 SendCommand $innode $SWITCH_RESET
166 then
167 exit 0
168 else
169 exit 1
170 fi
171 ;;
172 status)
173 if [ -z "$pduip" ]; then
174 exit 1
175 fi
176
177 if ping -w1 -c1 $pduip >/dev/null 2>&1; then
178 exit 0
179 else
180 exit 1
181 fi
182 ;;
183 getconfignames)
184 echo "hostlist pduip community"
185 exit 0
186 ;;
187 getinfo-devid)
188 echo "rackpdu STONITH device"
189 exit 0
190 ;;
191 getinfo-devname)
192 echo "rackpdu STONITH external device"
193 exit 0
194 ;;
195 getinfo-devdescr)
196 echo "APC Switched Rack PDU"
197 exit 0
198 ;;
199 getinfo-devurl)
200 echo "http://www.apcc.com/products/family/index.cfm?id=30"
201 exit 0
202 ;;
203 getinfo-xml)
204 cat << PDUXML
205 <parameters>
206 <parameter name="hostlist" unique="1" required="1">
207 <content type="string" default="AUTO" />
208 <shortdesc lang="en">Hostlist</shortdesc>
209 <longdesc lang="en">
210 The list of hosts that the STONITH device controls (comma or space separated).
211 If you set value of this parameter to AUTO, list of hosts will be get from Rack PDU device.
212 </longdesc>
213 </parameter>
214
215 <parameter name="pduip" unique="1" required="1">
216 <content type="string" />
217 <shortdesc lang="en">Name or IP address of Rack PDU device.</shortdesc>
218 <longdesc lang="en">Name or IP address of Rack PDU device.</longdesc>
219 </parameter>
220
221 <parameter name="community" unique="1" required="1">
222 <content type="string" default="private" />
223 <shortdesc lang="en">Name of write community.</shortdesc>
224 <longdesc lang="en">Name of write community.</longdesc>
225 </parameter>
226
227 <parameter name="oid" unique="1" required="0">
228 <content type="string" />
229 <shortdesc lang="en">
230 The OID without the outlet number.
231 </shortdesc>
232 <longdesc lang="en">
233 The SNMP OID for the PDU. minus the outlet number.
234 Try .1.3.6.1.4.1.318.1.1.12.3.3.1.1.4 (default value)
235 or use mib from ftp://ftp.apcc.com/apc/public/software/pnetmib/mib/
236 Varies on different APC hardware and firmware.
237 Warning! No dot at the end of OID
238 </longdesc>
239 </parameter>
240
241 <parameter name="names_oid" unique="1" required="0">
242 <content type="string" />
243 <shortdesc lang="en">The OID for getting names of outlets.</shortdesc>
244 <longdesc lang="en">
245 The SNMP OID for getting names of outlets.
246 It is required to recognize outlet number by nodename.
247 Try ".1.3.6.1.4.1.318.1.1.12.3.3.1.1.2" (default value)
248 or use mib from ftp://ftp.apcc.com/apc/public/software/pnetmib/mib/
249 Names of nodes must be equal names of outlets, in other way use outlet_config parameter.
250 If you set 'names_oid' parameter then parameter outlet_config must not be use.
251 Varies on different APC hardware and firmware.
252 Warning! No dot at the end of OID
253 </longdesc>
254 </parameter>
255
256 <parameter name="outlet_config" unique="1" required="0">
257 <content type="string" />
258 <shortdesc lang="en">Configuration file. Other way to recognize outlet number by nodename.</shortdesc>
259 <longdesc lang="en">
260 Configuration file. Other way to recognize outlet number by nodename.
261 Configuration file which contains
262 node_name=outlet_number
263 strings.
264
265 Example:
266 server1=1
267 server2=2
268
269 If you use outlet_config parameter then names_oid parameter can have any value and it is not uses.
270 </longdesc>
271 </parameter>
272
273 </parameters>
274 PDUXML
275 exit 0
276 ;;
277 *)