The SEC Control Panel and SEC Plot Panel |
| 2 |
======================================== |
| 3 |
|
| 4 |
**WARNING:** The manual is current several versions out of date. While it may |
| 5 |
still be useful for some users, please refer to the tutorial for the most |
| 6 |
up-to-date information. |
| 7 |
|
| 8 |
.. _secplot: |
| 9 |
|
| 10 |
When SEC-SAXS data is loaded into RAW, it is placed in the SEC tab of the Control |
| 11 |
Panel, and displayed in the SEC Plot window. This section will cover the features |
| 12 |
of the SEC control panel and the SEC plot panel. |
| 13 |
|
| 14 |
SEC-SAXS data is assumed to come from continuous collection of images while sample is |
| 15 |
being eluted from an FPLC column. Depending on the frame rate of the detector and the |
| 16 |
total elution time, this can generate thousands of images. The basic approach RAW uses |
| 17 |
to deal with this data is to load every scattering profile (or integrate every image |
| 18 |
into a scattering profile), and associate it with a single SEC data item. For each SEC |
| 19 |
item, the total (or average) intensity in each scattering profile is plotted vs. frame |
| 20 |
number, where frame number is simply what position the item was loaded in (so if 10 items |
| 21 |
are loaded, the frame number for the first item loaded would be 0, for the next item loaded |
| 22 |
1, etc). For standard SEC-SAXS data, this intensity vs. frame number should look similar to |
| 23 |
the UV chromatograph of the sample after it passes through the column. Some analysis can be |
| 24 |
carried out directly on this SEC data item, and the scattering profiles of interest can be |
| 25 |
extracted for further analysis. |
| 26 |
|
| 27 |
|
| 28 |
The SEC control panel |
| 29 |
--------------------- |
| 30 |
|
| 31 |
The SEC control panel refers to the panel that is shown in the Control panel when the SEC |
| 32 |
tab is selected. |
| 33 |
|
| 34 |
The panel consists of three parts. The top part is a set of controls for loading SEC items, |
| 35 |
controlling the SEC online mode, and analyzing SEC items. The middle part is where individual |
| 36 |
SEC items loaded into RAW are shown. The bottom part consists of buttons that allow you to |
| 37 |
save or remove the SEC items. Further manipulation of the SEC items can be done from the right |
| 38 |
click (context) menu. |
| 39 |
|
| 40 |
An individual item in the SEC list is the called a SEC data item. It is associated with two |
| 41 |
curves on the SEC plot, one plotted on the right y axis and one on the left y axis. |
| 42 |
|
| 43 |
|
| 44 |
SEC Data Items |
| 45 |
~~~~~~~~~~~~~~ |
| 46 |
|
| 47 |
When a new item is plotted, a data item is added to the SEC list in the SEC control panel. This |
| 48 |
allows you to control the properties of the data item, and perform analysis on it. |
| 49 |
|
| 50 |
The name of the data item is displayed for each item. If an item is given a different name for the |
| 51 |
plot legend, this legend name is displayed in [square brackets] next to the item name. On the same |
| 52 |
line as the item name, on the right side of the data item, there are several buttons that can be |
| 53 |
used for further manipulation of the data item. |
| 54 |
|
| 55 |
SEC data items are different from Manipulation and IFT data items as they have many (often hundreds |
| 56 |
or thousands) of scattering profiles associated with a single data item, and they can have new |
| 57 |
profiles appended to them after they are loaded. |
| 58 |
|
| 59 |
**Note:** If there is a \* to the left of the item name (between the checkbox and the item name), |
| 60 |
it indicates there are unsaved changes to the item. This can occur if the item is newly created IFT |
| 61 |
data (such as from the BIFT or GNOM panels), or if item properties such as the name have been changed. |
| 62 |
|
| 63 |
|
| 64 |
Showing/Hiding data items on the SEC plot |
| 65 |
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| 66 |
|
| 67 |
To show/hide the curves on the plot associated with a data item, click the checkbox next to the |
| 68 |
filename. If the checkbox is checked, the item is currently shown on the SEC plot, if the checkbox |
| 69 |
is unchecked, the item is currently hidden on the SEC plot. |
| 70 |
|
| 71 |
|
| 72 |
Data item buttons |
| 73 |
~~~~~~~~~~~~~~~~~ |
| 74 |
|
| 75 |
On the right of the data item are several buttons for controlling the data item. In order of left |
| 76 |
to right, these buttons have the following properties. |
| 77 |
|
| 78 |
*Extended Info* |
| 79 |
|
| 80 |
By hovering the mouse over the i in the blue circle button, a tooltip will appear which shows more |
| 81 |
information about the item. It shows the buffer range and window size used (if any) to calculate the |
| 82 |
structural parameters of the SEC data item as a function of frame number. |
| 83 |
|
| 84 |
*Locate Line* |
| 85 |
|
| 86 |
The target button is used to highlight the scattering profile on the graph that is associated |
| 87 |
with the data item. When the target is pressed, it ‘bolds’ the line each plotted curve associated |
| 88 |
with the data item (increases the line width by several points). When the target is pressed again, |
| 89 |
the line width is set back to normal. You can tell if a line is currently bolded, as the target will |
| 90 |
be orange instead of grey. |
| 91 |
|
| 92 |
*Line Properties* |
| 93 |
|
| 94 |
The colored line button has two purposes. First, the color matches the current color of the Intensity |
| 95 |
curve in the SEC Plot. Second, when pressed it opens a :ref:`line properties dialog <lineproperties>` |
| 96 |
which allows you to set the legend label; the line style, width, and color; the data point |
| 97 |
marker style, size, line color, and fill color; and the error bar line style, width, and |
| 98 |
color for each line associated with the SEC data item. |
| 99 |
|
| 100 |
*Mark* |
| 101 |
|
| 102 |
The star button marks an item. This is used when doing operations such as sending data frames to plot |
| 103 |
or calculating structural parameters. In those cases, the marked (also referred to as starred) item |
| 104 |
has a special significance. |
| 105 |
|
| 106 |
|
| 107 |
Loading data items |
| 108 |
~~~~~~~~~~~~~~~~~~ |
| 109 |
|
| 110 |
SEC data items can be loaded from the :ref:`files tab <filepanel>`. There is an additional way |
| 111 |
to load files available in the SEC control panel, this method is intended to be used in |
| 112 |
conjunction with the SEC online mode. This method is described in the rest of this section. |
| 113 |
|
| 114 |
At the top of the SEC control panel, there is a section for loading files. It has a button |
| 115 |
“Select file in SEC run”, and then descriptive information about the file: the image prefix, |
| 116 |
the run number, and the frame numbers of the file. Note that none of these descriptive fields |
| 117 |
can be edited. Below the descriptive fields is an “Update” button and an “Automatically Update” |
| 118 |
checkbox. |
| 119 |
|
| 120 |
To load a SEC curve using this method, click the “Select file in SEC run” button. In the file |
| 121 |
browser that pops up, select any file in the SEC data set. The data set will automatically be |
| 122 |
loaded into RAW as a SEC item, and the descriptive information will be displayed in the appropriate |
| 123 |
boxes. This loaded file can then be used with the SEC automatic update mode described |
| 124 |
:ref:`below <secautoupdate>`. |
| 125 |
|
| 126 |
**Note:** Due to how files are loaded from the SEC control panel, it only works for certain header |
| 127 |
file types. RAW must be able to automatically determine what files are associated with the SEC run, |
| 128 |
from any file in the run. At the moment, this can only be done with the G1 and G1 WAXS header file |
| 129 |
formats. If you want to have a particular beamline’s file format added to this loading (and thus able |
| 130 |
to use the online mode) please contact the RAW developers. |
| 131 |
|
| 132 |
|
| 133 |
Updating a SEC data item |
| 134 |
~~~~~~~~~~~~~~~~~~~~~~~~ |
| 135 |
|
| 136 |
If a SEC data item is loaded via the SEC control panel, it can be updated if additional files are |
| 137 |
added to the folder that are part of the data collection. This can only be done for the most recent |
| 138 |
file loaded via the SEC control panel, for which the descriptive information is shown at the top of |
| 139 |
the SEC control panel. |
| 140 |
|
| 141 |
To do this update, hit the “Update” button on the SEC control panel. RAW will automatically determine |
| 142 |
all of the files associated with the SEC run, based on the file you selected with the “Select file |
| 143 |
in SEC run” button, determine if any of those files have not yet been loaded, and if so, |
| 144 |
load the files and add them to the SEC item as appropriate. |
| 145 |
|
| 146 |
This is useful when working at the beamline while data is being collected, as you may want |
| 147 |
to start analysis of the SEC curve before all of the images are taken. |
| 148 |
|
| 149 |
|
| 150 |
SEC automatic update (online mode) |
| 151 |
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| 152 |
|
| 153 |
.. _secautoupdate: |
| 154 |
|
| 155 |
The SEC control panel can be used in an online mode, where a SEC curve is automatically |
| 156 |
updated as data comes in. All of the conditions for manually updating a curve, described above, |
| 157 |
must be met. Instead of using the “Update” button as in that section, check the “Automatically |
| 158 |
Update” box in the SEC control panel. |
| 159 |
|
| 160 |
**Note:** The automatic update will stay on even if you load a new file into the |
| 161 |
SEC panel using the “Select file in SEC run” button. It will switch to updating |
| 162 |
this newly loaded file. As with the “Update” button described above, the automatic |
| 163 |
update only applies to the SEC data item most recently loaded in the SEC panel. |
| 164 |
|
| 165 |
|
| 166 |
Selecting data items |
| 167 |
~~~~~~~~~~~~~~~~~~~~ |
| 168 |
|
| 169 |
A single data item can be selected by clicking on the item name in the SEC list |
| 170 |
(similar to how you would select files in your system file browser). When an item |
| 171 |
is selected, the color of the item background changes from white to gray. If the |
| 172 |
item is currently selected, clicking on it will cause it to be unselected. Note |
| 173 |
that for a regular click, all other selected items will be unselected when a new |
| 174 |
item is selected. |
| 175 |
|
| 176 |
Multiple items may be selected in two ways. If the Control key (Command key on Macs) |
| 177 |
is held down while clicking on items, each item that is clicked on will be added to the |
| 178 |
set of selected items. If a single item is first selected and then the Shift key is held |
| 179 |
down and another item is selected, all of the items in the list between the two items will |
| 180 |
be selected (including the second item that is clicked on). |
| 181 |
|
| 182 |
All of the items in the list can be selected in two ways. The first is using the |
| 183 |
:ref:`select all <iftselectall>` button, the second is pressing Ctrl-A (Cmd-A), the Control |
| 184 |
(Command) key and the A key at the same time when you are in the SEC panel. All items |
| 185 |
can be unselected by clicking in an empty spot of the SEC list (but not above or below |
| 186 |
the list), or by clicking on an already selected item. |
| 187 |
|
| 188 |
**Note:** If you have a set of selected items and wish to remove some, holding down the |
| 189 |
Control (Command) key and clicking on selected items will deselect them without affecting |
| 190 |
the other selected items. |
| 191 |
|
| 192 |
|
| 193 |
The top buttons of the SEC item list |
| 194 |
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| 195 |
|
| 196 |
The SEC item list has a set of three buttons at the top of the panel. These buttons have |
| 197 |
the following effects, listed from left to right. |
| 198 |
|
| 199 |
*Show All* |
| 200 |
|
| 201 |
Clicking on the button that looks like an eye will show all SEC items. This is the same as |
| 202 |
if you manually set all of the show/hide checkboxes in the data items to on. |
| 203 |
|
| 204 |
*Hide All* |
| 205 |
|
| 206 |
Clicking on the button that looks like an eye with a red x through it will hide all SEC |
| 207 |
items. This is the same as if you manually set all of the show/hide checkboxes in the data |
| 208 |
items to off. |
| 209 |
|
| 210 |
*Select All* |
| 211 |
|
| 212 |
Clicking on the button that looks like a spreadsheet with selected cells will select all |
| 213 |
of the SEC data items. |
| 214 |
|
| 215 |
|
| 216 |
Renaming a data item |
| 217 |
~~~~~~~~~~~~~~~~~~~~ |
| 218 |
|
| 219 |
Data items can be renamed by selecting the data item of interest and selecting “Rename” in |
| 220 |
the right click popup menu. |
| 221 |
|
| 222 |
**Note:** While no characters are expressly forbidden in the filename, RAW does not sanitize |
| 223 |
file names before saving, and thus special characters such as ‘/’ and ‘\\’ are likely to cause |
| 224 |
problems when the file is saved. |
| 225 |
|
| 226 |
|
| 227 |
Saving data items |
| 228 |
~~~~~~~~~~~~~~~~~ |
| 229 |
|
| 230 |
.. _savingsecdata: |
| 231 |
|
| 232 |
SEC items are saved as “.sec” files, and is the only data that RAW does not save in a human |
| 233 |
readable format. To save: |
| 234 |
|
| 235 |
#. Select the item(s) to be saved. |
| 236 |
|
| 237 |
#. Click the “Save” button or select “Save selected file(s)” from the right click menu. |
| 238 |
|
| 239 |
#. In the window that pops up, navigate to the directory in which you want to save the files. |
| 240 |
|
| 241 |
#. If you are saving a single item, the window will give you an opportunity to rename your |
| 242 |
file if desired. Click “Save” when ready. |
| 243 |
|
| 244 |
#. If you are saving multiple items, you simply need to select the folder for the items to |
| 245 |
be saved in, and click “Open”. The items will be saved with the same names displayed in |
| 246 |
the SEC Panel, in the folder that you chose. |
| 247 |
|
| 248 |
SEC items often contain hundreds or thousands of scattering profiles, so they are not saved in a |
| 249 |
human readable format. The “.sec” files that RAW saves can only be read by RAW. |
| 250 |
|
| 251 |
|
| 252 |
Removing data items from the SEC list |
| 253 |
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| 254 |
|
| 255 |
To remove one or more data items, select them and do one of the following: |
| 256 |
|
| 257 |
#. Press the “Delete” key on the keyboard |
| 258 |
|
| 259 |
#. Click the “Remove” button |
| 260 |
|
| 261 |
#. Select “Remove” from the right click menu |
| 262 |
|
| 263 |
|
| 264 |
Exporting SEC data |
| 265 |
~~~~~~~~~~~~~~~~~~ |
| 266 |
|
| 267 |
The following data can be exported in a spreadsheet ready format: frame number, |
| 268 |
integrated intensity, mean intensity, Rg, Rg error, I(0), I(0) error, MW, filename, |
| 269 |
and, if available intensity a q=<#> where <#> is a user selected value, for each individual |
| 270 |
point. |
| 271 |
|
| 272 |
To do so: |
| 273 |
|
| 274 |
#. Select the item(s) to be saved. |
| 275 |
|
| 276 |
#. Select “Export data” from the right click menu. |
| 277 |
|
| 278 |
#. In the window that pops up, navigate to the directory in which you want to save the file(s). |
| 279 |
|
| 280 |
#. If you are saving a single item, the window will give you an opportunity to rename your |
| 281 |
file if desired. Click “Save” when ready. |
| 282 |
|
| 283 |
#. If you are saving multiple items, you simply need to select the folder for the items to be |
| 284 |
saved in, and click “Open”. The items will be saved with the same names displayed in the SEC |
| 285 |
Panel, in the folder that you chose. |
| 286 |
|
| 287 |
The data is saved as a comma separated value (“.csv”) file. This can be opened directly into most |
| 288 |
spreadsheet programs, such as Excel. |
| 289 |
|
| 290 |
|
| 291 |
Saving all SEC scattering profiles |
| 292 |
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| 293 |
|
| 294 |
If you want to save every individual scattering profile loaded into a SEC data item, you can do so by: |
| 295 |
|
| 296 |
#. Select the item(s) to be saved. |
| 297 |
|
| 298 |
#. Select “Save all profiles as .dats” from the right click menu. |
| 299 |
|
| 300 |
#. In the window that pops up, navigate to the directory in which you want to save the file(s). |
| 301 |
|
| 302 |
#. Select the folder for the items to be saved in, and click “Open”. The items will be saved with |
| 303 |
the same filenames displayed in the :ref:`data browser <secdatadialog>`. |
| 304 |
|
| 305 |
|
| 306 |
Sending data to the main plot |
| 307 |
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| 308 |
|
| 309 |
Individual scattering profiles can be sent to the main plot for further analysis. This utilizes the |
| 310 |
middle section of the controls at the top of the SEC Control panel. |
| 311 |
|
| 312 |
To do so: |
| 313 |
|
| 314 |
#. Star the SEC data item containing the scattering profiles of interest (note: if only |
| 315 |
one SEC data item is loaded, it does not have to be starred). |
| 316 |
|
| 317 |
#. Enter the data frames of interest in the “Select Data Frames:” boxes. The box on the |
| 318 |
left is the first frame of interest, the box on the right is the last frame of interest. |
| 319 |
All of the frames between those two endpoints (inclusively) are selected. |
| 320 |
|
| 321 |
#. Either click the “Frames To Main Plot” button, which will send each individual frame selected |
| 322 |
in part 2 to the Main plot, or click “Average To Main Plot” which will send the average of the |
| 323 |
selected frames to the Main plot. |
| 324 |
|
| 325 |
#. Click on the Manipulation panel and Main plot panel to view the scattering profiles. |
| 326 |
|
| 327 |
|
| 328 |
Calculate structural parameters |
| 329 |
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| 330 |
|
| 331 |
.. _secparams: |
| 332 |
|
| 333 |
You can calculate the Rg, MW, and I(0) as a function of frame number for a SEC |
| 334 |
profile. This is done using the “Calculate/Plot Structural Parameters” section |
| 335 |
of the SEC control panel (the bottom section of the controls at the top of the panel). |
| 336 |
|
| 337 |
It is important to have a big picture for what is happening when this is done. First |
| 338 |
you set a buffer range. All of the scattering profiles in that range will be averaged, |
| 339 |
and then subtracted from every loaded scattering profile. Next you set a window size. |
| 340 |
This window will be slid across the curve and all of the frames within it averaged |
| 341 |
(note: this average is of the buffer subtracted scattering profiles). This Rg, MW, and |
| 342 |
I(0) for this averaged profile is then calculated. Those values are assigned to the center |
| 343 |
frame of the window. The window is then slid down the curve one frame, and the process is |
| 344 |
repeated until the window reaches the end of the SEC data. For example, if the window size |
| 345 |
is 5, the first 5 frames, frames 0, 1, 2, 3, and 4, are averaged, and have the Rg, MW, and |
| 346 |
I(0) calculated. Then window is moved over by one, and frames 1, 2, 3, 4, and 5 are averaged |
| 347 |
and have the Rg, MW, and I(0) calculated, and so on. |
| 348 |
|
| 349 |
To do this: |
| 350 |
|
| 351 |
#. Star the SEC data item containing the scattering profiles of interest (note: |
| 352 |
if only one SEC data item is loaded, it does not have to be starred). |
| 353 |
|
| 354 |
#. Enter the buffer range in the “Buffer Range” boxes. The box on the left is the |
| 355 |
starting buffer frame and the box on the right is the final buffer frame. |
| 356 |
|
| 357 |
#. Enter the window size. |
| 358 |
|
| 359 |
#. Select the appropriate molecule type (Protein or RNA) for the molecular weight calculation. |
| 360 |
|
| 361 |
#. Click the “Set/Update Parameters” button. |
| 362 |
|
| 363 |
#. The structural parameters will be plotted as a function of frame number in the SEC plot. |
| 364 |
If RAW was unable to determine the parameters for a particular window, then all parameters |
| 365 |
in that window are set to -1. |
| 366 |
|
| 367 |
The Rg and I(0) calculations are done using RAW’s :ref:`automatic rg function <guinierwindow>`. |
| 368 |
The molecular weight calculation is done using the |
| 369 |
:ref:`volume of correlation method <molweightmethods>`. |
| 370 |
|
| 371 |
**Note:** See :ref:`below <secplottypes>` for how to show different structural parameters |
| 372 |
on the SEC plot. |
| 373 |
|
| 374 |
|
| 375 |
Data point browsing |
| 376 |
~~~~~~~~~~~~~~~~~~~ |
| 377 |
|
| 378 |
.. _secdatadialog: |
| 379 |
|
| 380 |
The Frame number, integrated intensity, mean intensity, Rg, Rg error, I(0), I(0) error, |
| 381 |
MW, filename, and, if available intensity a q=<#> where <#> is a user selected value, |
| 382 |
for each individual point can be inspected using the data browser. To do so: |
| 383 |
|
| 384 |
#. Right-click on the data item of interest. |
| 385 |
|
| 386 |
#. Select “Show data” in the popup menu. |
| 387 |
|
| 388 |
|
| 389 |
The SEC data item right click menu options |
| 390 |
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| 391 |
|
| 392 |
When you right click on a data item, a popup menu is shown. This section describes what |
| 393 |
each item on the menu does. |
| 394 |
|
| 395 |
*Remove* |
| 396 |
|
| 397 |
Removes the item. |
| 398 |
|
| 399 |
*Export data* |
| 400 |
|
| 401 |
Exports the SEC data item to a spreadsheet. |
| 402 |
|
| 403 |
*Save all profiles as .dats* |
| 404 |
|
| 405 |
Saves all of the scattering profiles loaded into the SEC item as individual .dat files. |
| 406 |
|
| 407 |
*Save* |
| 408 |
|
| 409 |
Saves the selected data item(s). |
| 410 |
|
| 411 |
*SVD* |
| 412 |
|
| 413 |
Opens the singular value decomposition (SVD) analysis panel for the selected SEC item. |
| 414 |
|
| 415 |
*EFA* |
| 416 |
|
| 417 |
Opens the evolving factor analysis (EFA) panel for the selected SEC item. |
| 418 |
|
| 419 |
*Show data* |
| 420 |
|
| 421 |
Shows the individual data points. |
| 422 |
|
| 423 |
*Rename* |
| 424 |
|
| 425 |
Renames the data item. |
| 426 |
|
| 427 |
|
| 428 |
The SEC panel bottom buttons |
| 429 |
~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| 430 |
|
| 431 |
There are three buttons at the bottom of the SEC control panel. They are: |
| 432 |
|
| 433 |
*Save* |
| 434 |
|
| 435 |
This button saves the selected data item(s). |
| 436 |
|
| 437 |
*Remove* |
| 438 |
|
| 439 |
This button removes the selected data item(s) from the SEC panel. |
| 440 |
|
| 441 |
*Clear SEC Data* |
| 442 |
|
| 443 |
This button clears all loaded SEC data. It works the same as if you had selected |
| 444 |
all of the SEC data items and then removed them. |
| 445 |
|
| 446 |
|
| 447 |
The SEC Plot window |
| 448 |
------------------- |
| 449 |
|
| 450 |
The SEC plot window has only one plot, however data can be plotted on both the left |
| 451 |
and right y axes. The left axis plots intensity from scattering profiles, while the |
| 452 |
right axis plots structural parameters (Rg, MW, I(0)). The items associated with the |
| 453 |
plotted curves are shown in the SEC control panel list. |
| 454 |
|
| 455 |
The features that are general between all of the plots are described :ref:`elsewhere <genplotpanel>`. |
| 456 |
This section will describe features unique to this plot. |
| 457 |
|
| 458 |
|
| 459 |
Changing axes and plot types |
| 460 |
~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| 461 |
|
| 462 |
.. _secplottypes: |
| 463 |
|
| 464 |
Right-click in the plot to view a pop-up menu with different axis settings. In this |
| 465 |
plot, you can change what data is plotted on each axis. |
| 466 |
|
| 467 |
*Y Data (Left Axis)* |
| 468 |
|
| 469 |
This allows you to change intensity plotted on the left y axis. The methods are: |
| 470 |
|
| 471 |
* Integrated intensity (default), which is |
| 472 |
|
| 473 |
.. math:: |
| 474 |
I_{tot} = \int_{q_{min}}^{q_{max}} I(q) dq |
| 475 |
|
| 476 |
* Mean intensity, which is the average intensity across the whole scattering profile |
| 477 |
|
| 478 |
* Intensity at q=…, which allows the user to specify a q value, and displays the |
| 479 |
intensity at the nearest q point to that specified value. |
| 480 |
|
| 481 |
*Y Data (Right Axis)* |
| 482 |
|
| 483 |
This allows you to change which calculated structural parameter is plotted on the right y axis. |
| 484 |
|
| 485 |
#. RG (default) which plots the Rg |
| 486 |
|
| 487 |
#. MW which plots the molecular weight |
| 488 |
|
| 489 |
#. I(0) which plots the I(0) |
| 490 |
|
| 491 |
#. None, which turns off the right y axis. |
| 492 |
|
| 493 |
*X Data* |
| 494 |
|
| 495 |
This allows you to change what is plotted on the x axis. |
| 496 |
|
| 497 |
* Frame Number, which plots the intensity and structural parameter as a function of frame number. |
| 498 |
|
| 499 |
* Time, which puts the x axis in terms of experimental time. |
| 500 |
|
| 501 |
**Note:** The time display on the x axis is only available for certain types of header |
| 502 |
files. Currently only G1 and G1 WAXS header files will have associated time values. |
| 503 |
|