Debian Codegraph @

ansible_collections/cisco/intersight/plugins/modules/intersight_lan_connectivity_policy.py

raw
1 #!/usr/bin/python
2 # -*- coding: utf-8 -*-
3
4 # GNU General Public License v3.0+ (see COPYING or https://www.gnu.org/licenses/gpl-3.0.txt)
5
6 from __future__ import absolute_import, division, print_function
7 __metaclass__ = type
8
9 ANSIBLE_METADATA = {'metadata_version': '1.1',
10 'status': ['preview'],
11 'supported_by': 'community'}
12
13 DOCUMENTATION = r'''
14 ---
15 module: intersight_lan_connectivity_policy
16 short_description: Manage LAN Connectivity Policies and vNICs for Cisco Intersight
17 description:
18 - Create, update, and delete LAN Connectivity Policies on Cisco Intersight.
19 - Manage individual vNICs within LAN Connectivity policies.
20 - Supports both Standalone and FIAttached target platforms with different configuration options.
21 - LAN Connectivity policies define network connectivity settings for server profiles.
22 - For more information see L(Cisco Intersight,https://intersight.com/apidocs/vnic/LanConnectivityPolicy/get/).
23 extends_documentation_fragment: intersight
24 options:
25 state:
26 description:
27 - If C(present), will verify the resource is present and will create if needed.
28 - If C(absent), will verify the resource is absent and will delete if needed.
29 type: str
30 choices: [present, absent]
31 default: present
32 organization:
33 description:
34 - The name of the Organization this resource is assigned to.
35 - Policies created within a Custom Organization are applicable only to devices in the same Organization.
36 - Use 'default' for the default organization.
37 type: str
38 default: default
39 name:
40 description:
41 - The name assigned to the LAN Connectivity Policy.
42 - Must be unique within the organization.
43 - The name must be between 1 and 62 alphanumeric characters, allowing special characters :-_.
44 type: str
45 required: true
46 description:
47 description:
48 - The user-defined description for the LAN Connectivity Policy.
49 - Description can contain letters(a-z, A-Z), numbers(0-9), hyphen(-), period(.), colon(:), or an underscore(_).
50 type: str
51 aliases: [descr]
52 tags:
53 description:
54 - List of tags in Key:<user-defined key> Value:<user-defined value> format.
55 type: list
56 elements: dict
57 target_platform:
58 description:
59 - The platform type for which the LAN Connectivity policy is intended.
60 - Standalone for Standalone servers, FIAttached for fabric interconnect attached servers.
61 type: str
62 choices: ['Standalone', 'FIAttached']
63 default: 'Standalone'
64 azure_qos_enabled:
65 description:
66 - Enable Azure QoS for the LAN Connectivity policy.
67 - Only applicable when target_platform is 'FIAttached'.
68 type: bool
69 default: false
70 iqn_allocation_type:
71 description:
72 - IQN allocation type for the LAN Connectivity policy.
73 - Only applicable when target_platform is 'FIAttached'.
74 type: str
75 choices: ['None', 'Pool', 'Static']
76 default: 'None'
77 placement_mode:
78 description:
79 - Placement mode for vNIC assignment.
80 - Only applicable when target_platform is 'FIAttached'.
81 type: str
82 choices: ['custom', 'auto']
83 default: 'custom'
84 iqn_pool_name:
85 description:
86 - Relationship to the iSCSI Qualified Name Pool.
87 - Required when iqn_allocation_type is 'Pool'.
88 - Only applicable for FIAttached target platform.
89 type: str
90 static_iqn_name:
91 description:
92 - User provided static iSCSI Qualified Name (IQN) for use as initiator identifiers by iSCSI vNICs in a Fabric Interconnect domain.
93 - Required when iqn_allocation_type is 'Static'.
94 - Only applicable for FIAttached target platform.
95 type: str
96 vnics:
97 description:
98 - List of vNICs to be created and attached to the LAN Connectivity policy.
99 - Each vNIC will be configured with the specified network and adapter policies.
100 - Required when C(state) is C(present).
101 - At least one vNIC must be specified for both Standalone and FIAttached platforms.
102 type: list
103 elements: dict
104 suboptions:
105 name:
106 description:
107 - The name of the vNIC.
108 - Must be unique within the LAN Connectivity policy.
109 type: str
110 required: true
111 placement_slot_id:
112 description:
113 - PCIe Slot where the VIC adapter is installed.
114 - Supported values are (1-15) and MLOM.
115 - Required when vNIC state is 'present'.
116 type: str
117 uplink_port:
118 description:
119 - Adapter port on which the virtual interface will be created.
120 type: int
121 choices: [0, 1, 2, 3]
122 default: 0
123 order:
124 description:
125 - The order in which the virtual interface is brought up.
126 - The order assigned to an interface should be unique for all the Ethernet and Fibre-Channel interfaces on each PCI link on a VIC adapter.
127 - The order should start from zero with no overlaps.
128 - The maximum value of PCI order is limited by the number of virtual interfaces (Ethernet and Fibre-Channel) on each PCI link on a VIC adapter.
129 - All VIC adapters have a single PCI link except VIC 1340, VIC 1380 and VIC 1385 which have two.
130 type: int
131 default: 0
132 cdn_source:
133 description:
134 - Source of the CDN. It can either be user specified or be the same as the vNIC name.
135 type: str
136 choices: ['vnic', 'user']
137 default: 'vnic'
138 cdn_value:
139 description:
140 - CDN value when cdn_source is 'user'.
141 type: str
142 eth_network_policy_name:
143 description:
144 - Relationship to the Ethernet Network Policy.
145 - Required when vNIC state is 'present'.
146 type: str
147 eth_qos_policy_name:
148 description:
149 - Relationship to the Ethernet QoS Policy.
150 - Required when vNIC state is 'present'.
151 type: str
152 eth_adapter_policy_name:
153 description:
154 - Relationship to the Ethernet Adapter Policy.
155 - Required when vNIC state is 'present'.
156 type: str
157 connection_type:
158 description:
159 - Type of connection for the vNIC.
160 type: str
161 choices: ['none', 'usnic', 'vmq', 'sriov']
162 default: 'none'
163 mac_address_type:
164 description:
165 - Type of MAC address assignment.
166 - Only applicable for FIAttached target platform.
167 type: str
168 choices: ['pool', 'static']
169 default: 'pool'
170 mac_pool_name:
171 description:
172 - The MAC pool that is assigned.
173 - Required when mac_address_type is 'pool' and target platform is FIAttached.
174 - Only applicable for FIAttached target platform.
175 type: str
176 static_mac_address:
177 description:
178 - The MAC address must be in hexadecimal format xx:xx:xx:xx:xx:xx.
179 - To ensure uniqueness of MACs in the LAN fabric, you are strongly encouraged to use the following MAC prefix 00:25:B5:xx:xx:xx.
180 - Required when mac_address_type is 'static' and target platform is FIAttached.
181 - Only applicable for FIAttached target platform.
182 type: str
183 pci_link:
184 description:
185 - The PCI Link used as transport for the virtual interface.
186 - PCI Link is only applicable for select Cisco UCS VIC 1300 models (UCSC-PCIE-C40Q-03, UCSB-MLOM-40G-03, UCSB-VIC-M83-8P) that support two PCI links.
187 - The value, if specified, for any other VIC model will be ignored.
188 - For FIAttached required when pci_link_assignment_mode is 'Custom'.
189 type: int
190 choices: [0, 1]
191 default: 0
192 auto_slot_id:
193 description:
194 - Enable or disable automatic assignment of the VIC slot ID.
195 - If enabled and the server has only one VIC, the same VIC is chosen for all the vNICs.
196 - If enabled and the server has multiple VICs, the vNIC/vHBA are deployed on the first VIC.
197 - If disabled, placement_slot_id must be specified.
198 - Only applicable for FIAttached target platform when auto_vnic_placement_enabled is false.
199 type: bool
200 default: true
201 auto_pci_link:
202 description:
203 - Enable or disable automatic assignment of the PCI Link in a dual-link adapter.
204 - This option applies only to 13xx series VICs that support dual-link.
205 - If enabled, the system determines the placement of the vNIC/vHBA on either of the PCI Links.
206 - If disabled, pci_link_assignment_mode must be specified.
207 - Only applicable for FIAttached target platform when auto_vnic_placement_enabled is false.
208 type: bool
209 default: true
210 pci_link_assignment_mode:
211 description:
212 - PCI Link assignment mode when auto_pci_link is disabled.
213 - Custom allows manual selection of PCI link via pci_link parameter.
214 - Load-Balanced automatically distributes vNICs across available PCI links.
215 - Required when auto_pci_link is false and auto_vnic_placement_enabled is false.
216 - Only applicable for FIAttached target platform.
217 type: str
218 choices: ['Custom', 'Load-Balanced']
219 auto_vnic_placement_enabled:
220 description:
221 - Enable automatic vNIC placement for FIAttached servers.
222 - When enabled, the vNIC placement is simplified to only specify the switch ID.
223 - When disabled, full placement control is available including order, auto_slot_id, and auto_pci_link.
224 - Only applicable for FIAttached target platform.
225 type: bool
226 default: false
227 switch_id:
228 description:
229 - The fabric port to which the vNICs will be associated.
230 - Only applicable for FIAttached target platform.
231 type: str
232 choices: ['A', 'B']
233 default: 'A'
234 failover_enabled:
235 description:
236 - Enables automatic vNIC failover to the secondary Fabric Interconnect
237 if the primary path fails.
238 - Failover applies only to Cisco VICs that are connected to a Fabric Interconnect cluster.
239 - Only applicable for FIAttached target platform.
240 type: bool
241 default: false
242 fabric_eth_network_group_policy_name:
243 description:
244 - Relationship to the Fabric Ethernet Group Policy.
245 - Required when target platform is FIAttached and vNIC state is 'present'.
246 - Only applicable for FIAttached target platform.
247 type: str
248 fabric_eth_network_control_policy_name:
249 description:
250 - Relationship to the Fabric Ethernet Network Policy.
251 - Required when target platform is FIAttached and vNIC state is 'present'.
252 - Only applicable for FIAttached target platform.
253 type: str
254 iscsi_boot_policy_name:
255 description:
256 - Relationship to the boot iSCSI Policy.
257 - Only applicable for FIAttached target platform.
258 type: str
259 pin_group_name:
260 description:
261 - Pingroup name associated to vNIC for static pinning.
262 - LCP deploy will resolve pingroup name and fetches the corresponding uplink port/port channel to pin the vNIC traffic.
263 - Only applicable for FIAttached target platform.
264 type: str
265 usnic_settings:
266 description:
267 - USNIC settings when connection_type is 'usnic'.
268 - Required when connection_type is 'usnic'.
269 type: dict
270 suboptions:
271 count:
272 description:
273 - Number of usNIC interfaces to be created.
274 - When usNIC is enabled, the valid values are from 1 to 225.
275 - When usNIC is disabled, the default value is 0.
276 type: int
277 default: 0
278 cos:
279 description:
280 - Class of Service to be used for traffic on the usNIC.
281 type: int
282 choices: [0, 1, 2, 3, 4, 5, 6]
283 default: 5
284 usnic_adapter_policy_name:
285 description:
286 - Ethernet Adapter policy to be associated with the usNICs.
287 - Required when connection_type is 'usnic'.
288 type: str
289 vmq_settings:
290 description:
291 - VMQ settings when connection_type is 'vmq'.
292 type: dict
293 suboptions:
294 enabled:
295 description:
296 - Enable VMQ.
297 type: bool
298 default: true
299 multi_queue_support:
300 description:
301 - Enables Virtual Machine Multi-Queue feature on the virtual interface.
302 - VMMQ allows configuration of multiple I/O queues for a single VM and thus distributes traffic across multiple CPU cores in a VM.
303 type: bool
304 default: false
305 num_interrupts:
306 description:
307 - The number of interrupt resources to be allocated.
308 - Recommended value is the number of CPU threads or logical processors available in the server.
309 type: int
310 default: 16
311 num_vmqs:
312 description:
313 - The number of hardware Virtual Machine Queues to be allocated.
314 - The number of VMQs per adapter must be one more than the maximum number of VM NICs.
315 type: int
316 default: 4
317 num_sub_vnics:
318 description:
319 - Number of sub vNICs (0-64).
320 - Only applicable when multi_queue_support is true.
321 type: int
322 default: 64
323 vmmq_adapter_policy_name:
324 description:
325 - Name of the VMMQ Adapter Policy.
326 - Only applicable when multi_queue_support is true.
327 type: str
328 sriov_settings:
329 description:
330 - SR-IOV settings when connection_type is 'sriov'.
331 type: dict
332 suboptions:
333 enabled:
334 description:
335 - Enable SR-IOV.
336 type: bool
337 default: true
338 vf_count:
339 description:
340 - Number of Virtual Functions (1-64).
341 type: int
342 default: 64
343 rx_count_per_vf:
344 description:
345 - Receive Queue Count per VF (1-8).
346 type: int
347 default: 4
348 tx_count_per_vf:
349 description:
350 - Transmit Queue Count per VF (1-8).
351 type: int
352 default: 1
353 comp_count_per_vf:
354 description:
355 - Completion Queue Count per VF (1-16).
356 type: int
357 default: 5
358 int_count_per_vf:
359 description:
360 - Interrupt Count per VF (1-16).
361 type: int
362 default: 8
363 state:
364 description:
365 - Whether to create/update or delete the vNIC.
366 type: str
367 choices: ['present', 'absent']
368 default: present
369 author:
370 - Ron Gershburg (@rgershbu)
371 '''
372
373 EXAMPLES = r'''
374 - name: Create a LAN Connectivity Policy for Standalone servers
375 cisco.intersight.intersight_lan_connectivity_policy:
376 api_private_key: "{{ api_private_key }}"
377 api_key_id: "{{ api_key_id }}"
378 organization: "default"
379 name: "Standalone-lan-policy"
380 description: "LAN connectivity policy for Standalone servers"
381 target_platform: "Standalone"
382 tags:
383 - Key: "Environment"
384 Value: "Production"
385 - Key: "Site"
386 Value: "DataCenter-A"
387 vnics:
388 - name: "eth0"
389 placement_slot_id: "1"
390 pci_link: 0
391 uplink_port: 0
392 order: 0
393 eth_network_policy_name: "default-network-policy"
394 eth_qos_policy_name: "default-qos-policy"
395 eth_adapter_policy_name: "default-adapter-policy"
396 connection_type: "none"
397 - name: "eth1"
398 placement_slot_id: "2"
399 pci_link: 0
400 uplink_port: 1
401 order: 1
402 eth_network_policy_name: "vlan-network-policy"
403 eth_qos_policy_name: "high-qos-policy"
404 eth_adapter_policy_name: "performance-adapter-policy"
405 connection_type: "none"
406 state: present
407
408 - name: Create a LAN Connectivity Policy for FIAttached servers
409 cisco.intersight.intersight_lan_connectivity_policy:
410 api_private_key: "{{ api_private_key }}"
411 api_key_id: "{{ api_key_id }}"
412 organization: "default"
413 name: "fi-attached-lan-policy"
414 description: "LAN connectivity policy for FIAttached servers"
415 target_platform: "FIAttached"
416 azure_qos_enabled: true
417 iqn_allocation_type: "Pool"
418 iqn_pool_name: "default-iqn-pool"
419 placement_mode: "custom"
420 tags:
421 - Key: "Environment"
422 Value: "Production"
423 vnics:
424 - name: "vnic-fi-attached"
425 order: 0
426 cdn_source: "vnic"
427 mac_address_type: "pool"
428 mac_pool_name: "default-mac-pool"
429 auto_slot_id: true
430 auto_pci_link: true
431 auto_vnic_placement_enabled: false
432 switch_id: "A"
433 failover_enabled: false
434 fabric_eth_network_group_policy_name: "default-network-group"
435 fabric_eth_network_control_policy_name: "default-network-control"
436 eth_qos_policy_name: "default-qos-policy"
437 eth_adapter_policy_name: "default-adapter-policy"
438 connection_type: "none"
439 state: present
440 state: present
441
442 - name: Create a LAN Connectivity Policy with pin group for static pinning
443 cisco.intersight.intersight_lan_connectivity_policy:
444 api_private_key: "{{ api_private_key }}"
445 api_key_id: "{{ api_key_id }}"
446 organization: "default"
447 name: "fi-attached-pinned-policy"
448 description: "LAN connectivity policy with static uplink pinning"
449 target_platform: "FIAttached"
450 azure_qos_enabled: false
451 iqn_allocation_type: "None"
452 placement_mode: "custom"
453 vnics:
454 - name: "pinned-vnic"
455 order: 0
456 cdn_source: "vnic"
457 mac_address_type: "pool"
458 mac_pool_name: "default-mac-pool"
459 auto_slot_id: true
460 auto_pci_link: true
461 auto_vnic_placement_enabled: false
462 switch_id: "A"
463 failover_enabled: false
464 fabric_eth_network_group_policy_name: "default-network-group"
465 fabric_eth_network_control_policy_name: "default-network-control"
466 eth_qos_policy_name: "default-qos-policy"
467 eth_adapter_policy_name: "default-adapter-policy"
468 pin_group_name: "pingroup-a"
469 connection_type: "none"
470 state: present
471 state: present
472
473 - name: Create a LAN Connectivity Policy with automatic vNIC placement
474 cisco.intersight.intersight_lan_connectivity_policy:
475 api_private_key: "{{ api_private_key }}"
476 api_key_id: "{{ api_key_id }}"
477 organization: "default"
478 name: "fi-attached-auto-placement-policy"
479 description: "LAN connectivity policy with automatic vNIC placement"
480 target_platform: "FIAttached"
481 azure_qos_enabled: false
482 iqn_allocation_type: "None"
483 placement_mode: "auto"
484 vnics:
485 - name: "auto-placed-vnic"
486 cdn_source: "vnic"
487 mac_address_type: "pool"
488 mac_pool_name: "default-mac-pool"
489 auto_vnic_placement_enabled: true
490 switch_id: "A"
491 failover_enabled: false
492 fabric_eth_network_group_policy_name: "default-network-group"
493 fabric_eth_network_control_policy_name: "default-network-control"
494 eth_qos_policy_name: "default-qos-policy"
495 eth_adapter_policy_name: "default-adapter-policy"
496 connection_type: "none"
497 state: present
498 state: present
499
500 - name: Create a LAN Connectivity Policy with advanced placement control
501 cisco.intersight.intersight_lan_connectivity_policy:
502 api_private_key: "{{ api_private_key }}"
503 api_key_id: "{{ api_key_id }}"
504 organization: "default"
505 name: "fi-attached-advanced-placement-policy"
506 description: "LAN connectivity policy with advanced placement control"
507 target_platform: "FIAttached"
508 azure_qos_enabled: false
509 iqn_allocation_type: "None"
510 placement_mode: "custom"
511 vnics:
512 - name: "advanced-placed-vnic"
513 order: 9
514 cdn_source: "vnic"
515 mac_address_type: "pool"
516 mac_pool_name: "default-mac-pool"
517 auto_slot_id: false
518 placement_slot_id: "5"
519 auto_pci_link: false
520 pci_link_assignment_mode: "Custom"
521 pci_link: 0
522 auto_vnic_placement_enabled: false
523 switch_id: "A"
524 failover_enabled: false
525 fabric_eth_network_group_policy_name: "default-network-group"
526 fabric_eth_network_control_policy_name: "default-network-control"
527 eth_qos_policy_name: "default-qos-policy"
528 eth_adapter_policy_name: "default-adapter-policy"
529 connection_type: "none"
530 state: present
531 state: present
532
533 - name: Create a LAN Connectivity Policy with load-balanced PCI assignment
534 cisco.intersight.intersight_lan_connectivity_policy:
535 api_private_key: "{{ api_private_key }}"
536 api_key_id: "{{ api_key_id }}"
537 organization: "default"
538 name: "fi-attached-load-balanced-policy"
539 description: "LAN connectivity policy with load-balanced PCI assignment"
540 target_platform: "FIAttached"
541 azure_qos_enabled: false
542 iqn_allocation_type: "None"
543 placement_mode: "custom"
544 vnics:
545 - name: "load-balanced-vnic"
546 order: 5
547 cdn_source: "vnic"
548 mac_address_type: "pool"
549 mac_pool_name: "default-mac-pool"
550 auto_slot_id: false
551 placement_slot_id: "MLOM"
552 auto_pci_link: false
553 pci_link_assignment_mode: "Load-Balanced"
554 auto_vnic_placement_enabled: false
555 switch_id: "B"
556 failover_enabled: true
557 fabric_eth_network_group_policy_name: "default-network-group"
558 fabric_eth_network_control_policy_name: "default-network-control"
559 eth_qos_policy_name: "default-qos-policy"
560 eth_adapter_policy_name: "default-adapter-policy"
561 connection_type: "none"
562 state: present
563 state: present
564
565 - name: Create a LAN Connectivity Policy with USNIC vNIC
566 cisco.intersight.intersight_lan_connectivity_policy:
567 api_private_key: "{{ api_private_key }}"
568 api_key_id: "{{ api_key_id }}"
569 name: "usnic-lan-policy"
570 description: "Policy with USNIC configuration"
571 target_platform: "Standalone"
572 vnics:
573 - name: "usnic-eth0"
574 placement_slot_id: "4"
575 pci_link: 0
576 uplink_port: 0
577 order: 0
578 eth_network_policy_name: "hpc-network-policy"
579 eth_qos_policy_name: "hpc-qos-policy"
580 eth_adapter_policy_name: "hpc-adapter-policy"
581 connection_type: "usnic"
582 usnic_settings:
583 count: 0
584 cos: 5
585 usnic_adapter_policy_name: "hpc-adapter-policy"
586 state: present
587
588 - name: Create a LAN Connectivity Policy with VMQ vNIC
589 cisco.intersight.intersight_lan_connectivity_policy:
590 api_private_key: "{{ api_private_key }}"
591 api_key_id: "{{ api_key_id }}"
592 name: "vmq-lan-policy"
593 description: "Policy with VMQ configuration"
594 target_platform: "Standalone"
595 vnics:
596 - name: "vmq-eth0"
597 placement_slot_id: "10"
598 pci_link: 0
599 uplink_port: 2
600 order: 0
601 eth_network_policy_name: "vm-network-policy"
602 eth_qos_policy_name: "vm-qos-policy"
603 eth_adapter_policy_name: "vm-adapter-policy"
604 connection_type: "vmq"
605 vmq_settings:
606 enabled: true
607 multi_queue_support: false
608 num_interrupts: 16
609 num_vmqs: 4
610 state: present
611
612 - name: Create a LAN Connectivity Policy with VMQ multi-queue support
613 cisco.intersight.intersight_lan_connectivity_policy:
614 api_private_key: "{{ api_private_key }}"
615 api_key_id: "{{ api_key_id }}"
616 name: "vmq-multiqueue-lan-policy"
617 description: "Policy with VMQ multi-queue configuration"
618 target_platform: "Standalone"
619 vnics:
620 - name: "vmq-mq-eth0"
621 placement_slot_id: "11"
622 pci_link: 1
623 uplink_port: 3
624 order: 0
625 eth_network_policy_name: "vm-network-policy"
626 eth_qos_policy_name: "vm-qos-policy"
627 eth_adapter_policy_name: "vm-adapter-policy"
628 connection_type: "vmq"
629 vmq_settings:
630 enabled: true
631 multi_queue_support: true
632 num_sub_vnics: 64
633 vmmq_adapter_policy_name: "vmmq-adapter-policy"
634 state: present
635
636 - name: Create a LAN Connectivity Policy with SR-IOV vNIC
637 cisco.intersight.intersight_lan_connectivity_policy:
638 api_private_key: "{{ api_private_key }}"
639 api_key_id: "{{ api_key_id }}"
640 name: "sriov-lan-policy"
641 description: "Policy with SR-IOV configuration"
642 target_platform: "Standalone"
643 vnics:
644 - name: "sriov-eth0"
645 placement_slot_id: "14"
646 pci_link: 0
647 uplink_port: 1
648 order: 0
649 eth_network_policy_name: "sriov-network-policy"
650 eth_qos_policy_name: "sriov-qos-policy"
651 eth_adapter_policy_name: "sriov-adapter-policy"
652 connection_type: "sriov"
653 sriov_settings:
654 enabled: true
655 vf_count: 64
656 rx_count_per_vf: 4
657 tx_count_per_vf: 1
658 comp_count_per_vf: 5
659 int_count_per_vf: 8
660 state: present
661
662 - name: Create a LAN Connectivity Policy with custom CDN values
663 cisco.intersight.intersight_lan_connectivity_policy:
664 api_private_key: "{{ api_private_key }}"
665 api_key_id: "{{ api_key_id }}"
666 name: "custom-cdn-lan-policy"
667 description: "Policy with custom CDN values"
668 target_platform: "Standalone"
669 vnics:
670 - name: "mgmt-nic"
671 placement_slot_id: "1"
672 pci_link: 0
673 uplink_port: 0
674 order: 0
675 cdn_source: "user"
676 cdn_value: "Management-NIC"
677 eth_network_policy_name: "mgmt-network-policy"
678 eth_qos_policy_name: "mgmt-qos-policy"
679 eth_adapter_policy_name: "mgmt-adapter-policy"
680 connection_type: "none"
681 state: present
682
683 - name: Update LAN connectivity policy - manage vNIC states
684 cisco.intersight.intersight_lan_connectivity_policy:
685 api_private_key: "{{ api_private_key }}"
686 api_key_id: "{{ api_key_id }}"
687 organization: "default"
688 name: "mixed-vnic-states-policy"
689 description: "Policy demonstrating vNIC state management"
690 target_platform: "Standalone"
691 vnics:
692 - name: "eth0"
693 placement_slot_id: "1"
694 pci_link: 0
695 uplink_port: 0
696 order: 0
697 eth_network_policy_name: "production-network"
698 eth_qos_policy_name: "standard-qos"
699 eth_adapter_policy_name: "standard-adapter"
700 connection_type: "none"
701 state: present
702 - name: "eth1-old"
703 state: absent
704 - name: "eth2-new"
705 placement_slot_id: "3"
706 pci_link: 0
707 uplink_port: 1
708 order: 1
709 eth_network_policy_name: "production-network"
710 eth_qos_policy_name: "standard-qos"
711 eth_adapter_policy_name: "standard-adapter"
712 connection_type: "vmq"
713 vmq_settings:
714 enabled: true
715 multi_queue_support: false
716 num_interrupts: 16
717 num_vmqs: 4
718 state: present
719 state: present
720
721 - name: Delete a LAN Connectivity Policy
722 cisco.intersight.intersight_lan_connectivity_policy:
723 api_private_key: "{{ api_private_key }}"
724 api_key_id: "{{ api_key_id }}"
725 name: "old-lan-policy"
726 state: absent
727 '''
728
729 RETURN = r'''
730 api_response:
731 description: The API response output returned by the specified resource.
732 returned: always
733 type: dict
734 sample:
735 "api_response": {
736 "Name": "test-lan-policy",
737 "ObjectType": "vnic.LanConnectivityPolicy",
738 "TargetPlatform": "Standalone",
739 "Tags": [
740 {
741 "Key": "Environment",
742 "Value": "Production"
743 }
744 ],
745 "vNICs": [
746 {
747 "Name": "eth0",
748 "ObjectType": "vnic.EthIf",
749 "Order": 0,
750 "Placement": {
751 "Id": "1"
752 }
753 }
754 ]
755 }
756 '''
757
758
759 from ansible.module_utils.basic import AnsibleModule
760 from ansible_collections.cisco.intersight.plugins.module_utils.intersight import IntersightModule, intersight_argument_spec
761 from ansible_collections.cisco.intersight.plugins.module_utils.intersight_vnic_utils import (
762 validate_cdn_config, validate_usnic_settings, validate_vmq_settings, validate_sriov_settings,
763 build_cdn_config, build_connection_settings, resolve_policy_moids_from_mappings,
764 get_common_policy_mappings, get_iscsi_boot_policy_mapping, get_fabric_network_policy_mappings,
765 get_mac_pool_policy_mapping, get_common_settings_argument_spec
766 )
767
768
769 def validate_fi_attached_params(module):
770 """
771 Validate FIAttached specific parameters
772 """
773 iqn_allocation_type = module.params.get('iqn_allocation_type')
774 static_iqn_name = module.params.get('static_iqn_name')
775 iqn_pool_name = module.params.get('iqn_pool_name')
776
777 # Validate IQN allocation type requirements
778 if iqn_allocation_type == 'Static' and not static_iqn_name:
779 module.fail_json(msg="static_iqn_name is required when iqn_allocation_type is 'Static'")
780
781 if iqn_allocation_type == 'Pool' and not iqn_pool_name:
782 module.fail_json(msg="iqn_pool_name is required when iqn_allocation_type is 'Pool'")
783
784 if iqn_allocation_type != 'Static' and static_iqn_name:
785 module.fail_json(msg="static_iqn_name should only be specified when iqn_allocation_type is 'Static'")
786
787 if iqn_allocation_type != 'Pool' and iqn_pool_name:
788 module.fail_json(msg="iqn_pool_name should only be specified when iqn_allocation_type is 'Pool'")
789
790
791 def validate_fi_attached_vnic_config(module, vnic_config):
792 """
793 Validate FIAttached specific vNIC configuration
794 """
795 vnic_name = vnic_config.get('name', 'unknown')
796 mac_address_type = vnic_config.get('mac_address_type', 'pool')
797 mac_pool_name = vnic_config.get('mac_pool_name')
798 static_mac_address = vnic_config.get('static_mac_address')
799
800 # Validate MAC address configuration
801 if mac_address_type == 'pool' and not mac_pool_name:
802 module.fail_json(msg=f"mac_pool_name is required when mac_address_type is 'pool' for vNIC '{vnic_name}'")
803
804 if mac_address_type == 'static' and not static_mac_address:
805 module.fail_json(msg=f"static_mac_address is required when mac_address_type is 'static' for vNIC '{vnic_name}'")
806
807 if mac_address_type != 'pool' and mac_pool_name:
808 module.fail_json(msg=f"mac_pool_name should only be specified when mac_address_type is 'pool' for vNIC '{vnic_name}'")
809
810 if mac_address_type != 'static' and static_mac_address:
811 module.fail_json(msg=f"static_mac_address should only be specified when mac_address_type is 'static' for vNIC '{vnic_name}'")
812
813 # Validate required FIAttached fields
814 fabric_eth_network_group_policy_name = vnic_config.get('fabric_eth_network_group_policy_name')
815 fabric_eth_network_control_policy_name = vnic_config.get('fabric_eth_network_control_policy_name')
816
817 if not fabric_eth_network_group_policy_name:
818 module.fail_json(msg=f"fabric_eth_network_group_policy_name is required for attached vNIC '{vnic_name}'")
819
820 if not fabric_eth_network_control_policy_name:
821 module.fail_json(msg=f"fabric_eth_network_control_policy_name is required for attached vNIC '{vnic_name}'")
822
823 # Validate advanced placement configuration
824 validate_fi_attached_placement_config(module, vnic_config)
825
826
827 def validate_fi_attached_placement_config(module, vnic_config):
828 """
829 Validate FIAttached placement configuration
830 """
831 vnic_name = vnic_config.get('name', 'unknown')
832 auto_vnic_placement_enabled = vnic_config.get('auto_vnic_placement_enabled', False)
833
834 # Skip advanced placement validation if auto placement is enabled
835 if auto_vnic_placement_enabled:
836 return
837
838 auto_slot_id = vnic_config.get('auto_slot_id', True)
839 placement_slot_id = vnic_config.get('placement_slot_id')
840 auto_pci_link = vnic_config.get('auto_pci_link', True)
841 pci_link_assignment_mode = vnic_config.get('pci_link_assignment_mode')
842 pci_link = vnic_config.get('pci_link')
843
844 # Validate slot ID configuration
845 if not auto_slot_id and not placement_slot_id:
846 module.fail_json(msg=f"placement_slot_id is required when auto_slot_id is false for vNIC '{vnic_name}'")
847
848 if auto_slot_id and placement_slot_id:
849 module.fail_json(msg=f"placement_slot_id should not be specified when auto_slot_id is true for vNIC '{vnic_name}'")
850
851 # Validate PCI link configuration
852 if not auto_pci_link and not pci_link_assignment_mode:
853 module.fail_json(msg=f"pci_link_assignment_mode is required when auto_pci_link is false for vNIC '{vnic_name}'")
854
855 if auto_pci_link and pci_link_assignment_mode:
856 module.fail_json(msg=f"pci_link_assignment_mode should not be specified when auto_pci_link is true for vNIC '{vnic_name}'")
857
858 # Validate PCI link when using Custom mode
859 if pci_link_assignment_mode == 'Custom' and pci_link is None:
860 module.fail_json(msg=f"pci_link is required when pci_link_assignment_mode is 'Custom' for vNIC '{vnic_name}'")
861
862 if pci_link_assignment_mode != 'Custom' and pci_link is not None and pci_link != 0:
863 module.fail_json(msg=f"pci_link should only be specified when pci_link_assignment_mode is 'Custom' for vNIC '{vnic_name}'")
864
865
866 def validate_standalone_vnic_config(module, vnic_config):
867 """
868 Validate Standalone specific vNIC configuration
869 """
870 vnic_name = vnic_config.get('name', 'unknown')
871
872 # Validate required Standalone fields
873 placement_slot_id = vnic_config.get('placement_slot_id')
874 eth_network_policy_name = vnic_config.get('eth_network_policy_name')
875
876 if not placement_slot_id:
877 module.fail_json(msg=f"placement_slot_id is required for Standalone vNIC '{vnic_name}'")
878
879 if not eth_network_policy_name:
880 module.fail_json(msg=f"eth_network_policy_name is required for Standalone vNIC '{vnic_name}'")
881
882
883 def get_vnic_policy_mappings(target_platform, vnic_config):
884 """
885 Get policy mappings for vNIC configuration based on target platform.
886 """
887 # Start with common policies
888 policy_mappings = get_common_policy_mappings()
889
890 # Platform-specific policies
891 if target_platform == 'FIAttached':
892 # Add fabric network policies
893 policy_mappings.update(get_fabric_network_policy_mappings())
894
895 # MAC pool for FIAttached when using pool type
896 if vnic_config.get('mac_address_type', 'pool') == 'pool':
897 policy_mappings.update(get_mac_pool_policy_mapping())
898
899 # iSCSI boot policy
900 if vnic_config.get('iscsi_boot_policy_name'):
901 policy_mappings.update(get_iscsi_boot_policy_mapping())
902
903 else: # Standalone server
904 policy_mappings['eth_network_policy_name'] = ('/vnic/EthNetworkPolicies', 'EthNetworkPolicy', 'Ethernet Network Policy')
905
906 return policy_mappings
907
908
909 def resolve_vnic_policy_moids(intersight, policy_cache, module, vnic_config, target_platform):
910 """
911 Resolve all policy MOIDs for a vNIC configuration based on target platform.
912 """
913 policy_mappings = get_vnic_policy_mappings(target_platform, vnic_config)
914 organization_name = module.params['organization']
915 return resolve_policy_moids_from_mappings(intersight, policy_cache, module, vnic_config, policy_mappings, organization_name)
916
917
918 def build_vnic_api_body(intersight, policy_cache, module, vnic_config, lan_connectivity_policy_moid):
919 """
920 Build vNIC API body for API call
921 """
922 target_platform = module.params.get('target_platform')
923
924 if target_platform == 'FIAttached':
925 return build_fi_attached_vnic_api_body(intersight, policy_cache, module, vnic_config, lan_connectivity_policy_moid)
926 else:
927 return build_standalone_vnic_api_body(intersight, policy_cache, module, vnic_config, lan_connectivity_policy_moid)
928
929
930 def build_standalone_vnic_api_body(intersight, policy_cache, module, vnic_config, lan_connectivity_policy_moid):
931 """
932 Build Standalone vNIC API body for Intersight API call
933 """
934 # Base vNIC configuration for Standalone
935 vnic_api_body = {
936 'Name': vnic_config['name'],
937 'Placement': {
938 'Id': vnic_config['placement_slot_id'],
939 'Uplink': vnic_config.get('uplink_port', 0),
940 'PciLink': vnic_config.get('pci_link', 0)
941 },
942 'Order': vnic_config.get('order', 0),
943 'LanConnectivityPolicy': lan_connectivity_policy_moid
944 }
945
946 # Add common CDN configuration
947 vnic_api_body['Cdn'] = build_cdn_config(vnic_config)
948
949 # Resolve and add policy MOIDs
950 policy_moids = resolve_vnic_policy_moids(intersight, policy_cache, module, vnic_config, 'Standalone')
951 vnic_api_body.update(policy_moids)
952
953 # Add common connection type settings
954 organization_name = module.params['organization']
955 connection_settings = build_connection_settings(intersight, policy_cache, module, vnic_config, organization_name)
956 vnic_api_body.update(connection_settings)
957
958 return vnic_api_body
959
960
961 def build_fi_attached_vnic_api_body(intersight, policy_cache, module, vnic_config, lan_connectivity_policy_moid):
962 """
963 Build FIAttached vNIC API body for Intersight API call
964 """
965 # Base vNIC configuration for FIAttached
966 # Map lowercase user input to API format
967 mac_address_type = vnic_config.get('mac_address_type', 'pool')
968 api_mac_address_type = 'STATIC' if mac_address_type == 'static' else 'POOL'
969 auto_vnic_placement_enabled = vnic_config.get('auto_vnic_placement_enabled', False)
970
971 vnic_api_body = {
972 'Name': vnic_config['name'],
973 'MacAddressType': api_mac_address_type,
974 'FailoverEnabled': vnic_config.get('failover_enabled', False),
975 'LanConnectivityPolicy': lan_connectivity_policy_moid
976 }
977
978 # Handle placement based on auto_vnic_placement_enabled
979 if auto_vnic_placement_enabled:
980 vnic_api_body['Placement'] = {
981 'SwitchId': vnic_config.get('switch_id', 'A'),
982 'AutoSlotId': True,
983 'AutoPciLink': True
984 }
985 else:
986 # Full placement control
987 placement = {
988 'SwitchId': vnic_config.get('switch_id', 'A'),
989 'AutoSlotId': vnic_config.get('auto_slot_id', True),
990 'AutoPciLink': vnic_config.get('auto_pci_link', True)
991 }
992
993 # Add slot ID if auto_slot_id is disabled
994 if not vnic_config.get('auto_slot_id', True):
995 placement['Id'] = vnic_config['placement_slot_id']
996
997 # Add PCI link configuration if auto_pci_link is disabled
998 if not vnic_config.get('auto_pci_link', True):
999 placement['PciLinkAssignmentMode'] = vnic_config['pci_link_assignment_mode']
1000 if vnic_config['pci_link_assignment_mode'] == 'Custom':
1001 placement['PciLink'] = vnic_config.get('pci_link', 0)
1002
1003 vnic_api_body['Placement'] = placement
1004 vnic_api_body['Order'] = vnic_config.get('order', 0)
1005
1006 # Add common CDN configuration
1007 vnic_api_body['Cdn'] = build_cdn_config(vnic_config)
1008
1009 # Add static MAC address if using static type
1010 if mac_address_type == 'static':
1011 vnic_api_body['StaticMacAddress'] = vnic_config['static_mac_address']
1012
1013 # Resolve and add policy MOIDs
1014 policy_moids = resolve_vnic_policy_moids(intersight, policy_cache, module, vnic_config, 'FIAttached')
1015 vnic_api_body.update(policy_moids)
1016
1017 # Add common connection type settings
1018 organization_name = module.params['organization']
1019 connection_settings = build_connection_settings(intersight, policy_cache, module, vnic_config, organization_name)
1020 vnic_api_body.update(connection_settings)
1021
1022 # Add pin group name if specified
1023 if vnic_config.get('pin_group_name'):
1024 vnic_api_body['PinGroupName'] = vnic_config['pin_group_name']
1025
1026 return vnic_api_body
1027
1028
1029 def validate_input(module):
1030 """
1031 Validate module input parameters
1032 """
1033 # Validate FIAttached specific requirements
1034 target_platform = module.params.get('target_platform')
1035 if target_platform == 'FIAttached':
1036 validate_fi_attached_params(module)
1037
1038 # Validate vNIC configurations
1039 vnics = module.params.get('vnics', [])
1040 for vnic_config in vnics:
1041 vnic_name = vnic_config.get('name')
1042 vnic_state = vnic_config.get('state', 'present')
1043
1044 # Only validate present vNICs - absent vNICs only need name
1045 if vnic_state == 'present':
1046 # Validate common required fields
1047 required_fields = ['eth_qos_policy_name', 'eth_adapter_policy_name']
1048 for field in required_fields:
1049 if not vnic_config.get(field):
1050 module.fail_json(msg=f"{field} is required when vNIC state is 'present' for vNIC '{vnic_name}'")
1051
1052 # Validate target platform specific fields
1053 target_platform = module.params.get('target_platform')
1054 if target_platform == 'FIAttached':
1055 validate_fi_attached_vnic_config(module, vnic_config)
1056 else:
1057 validate_standalone_vnic_config(module, vnic_config)
1058
1059 # Validate CDN configuration
1060 validate_cdn_config(module, vnic_config)
1061
1062 connection_type = vnic_config.get('connection_type', 'none')
1063
1064 # Validate connection type specific settings
1065 vnic_name = vnic_config.get('name', 'unknown')
1066 if connection_type == 'usnic':
1067 usnic_settings = vnic_config.get('usnic_settings')
1068 validate_usnic_settings(module, usnic_settings, vnic_name)
1069 elif connection_type == 'vmq':
1070 vmq_settings = vnic_config.get('vmq_settings', {})
1071 validate_vmq_settings(module, vmq_settings, vnic_name)
1072 elif connection_type == 'sriov':
1073 sriov_settings = vnic_config.get('sriov_settings', {})
1074 validate_sriov_settings(module, sriov_settings, vnic_name)
1075
1076
1077 def main():
1078 # Define vNIC options
1079 vnic_options = dict(
1080 name=dict(type='str', required=True),
1081 state=dict(type='str', choices=['present', 'absent'], default='present'),
1082 placement_slot_id=dict(type='str'),
1083 pci_link=dict(type='int', choices=[0, 1], default=0),
1084 uplink_port=dict(type='int', choices=[0, 1, 2, 3], default=0),
1085 order=dict(type='int', default=0),
1086 eth_network_policy_name=dict(type='str'),
1087 eth_qos_policy_name=dict(type='str'),
1088 eth_adapter_policy_name=dict(type='str'),
1089 mac_address_type=dict(type='str', choices=['pool', 'static'], default='pool'),
1090 static_mac_address=dict(type='str'),
1091 auto_slot_id=dict(type='bool', default=True),
1092 auto_pci_link=dict(type='bool', default=True),
1093 pci_link_assignment_mode=dict(type='str', choices=['Custom', 'Load-Balanced']),
1094 auto_vnic_placement_enabled=dict(type='bool', default=False),
1095 pin_group_name=dict(type='str'),
1096 )
1097 # Add connection settings argument specs
1098 vnic_options.update(get_common_settings_argument_spec())
1099
1100 argument_spec = intersight_argument_spec.copy()
1101 argument_spec.update(
1102 state=dict(type='str', choices=['present', 'absent'], default='present'),
1103 organization=dict(type='str', default='default'),
1104 name=dict(type='str', required=True),
1105 description=dict(type='str', aliases=['descr']),
1106 tags=dict(type='list', elements='dict'),
1107 target_platform=dict(type='str', choices=['Standalone', 'FIAttached'], default='Standalone'),
1108 azure_qos_enabled=dict(type='bool', default=False),
1109 iqn_allocation_type=dict(type='str', choices=['None', 'Pool', 'Static'], default='None'),
1110 placement_mode=dict(type='str', choices=['custom', 'auto'], default='custom'),
1111 iqn_pool_name=dict(type='str'),
1112 static_iqn_name=dict(type='str'),
1113 vnics=dict(type='list', elements='dict', options=vnic_options)
1114 )
1115
1116 required_if = [
1117 ['state', 'present', ['vnics']],
1118 ]
1119
1120 module = AnsibleModule(
1121 argument_spec,
1122 required_if=required_if,
1123 supports_check_mode=True,
1124 )
1125
1126 if module.params['state'] == 'present':
1127 validate_input(module)
1128
1129 intersight = IntersightModule(module)
1130 intersight.result['api_response'] = {}
1131 intersight.result['trace_id'] = ''
1132
1133 # Resource path used to configure policy
1134 resource_path = '/vnic/LanConnectivityPolicies'
1135 # Define API body used in compares or create
1136 intersight.api_body = {
1137 'Organization': {
1138 'Name': intersight.module.params['organization'],
1139 },
1140 'Name': intersight.module.params['name']
1141 }
1142
1143 if intersight.module.params['state'] == 'present':
1144 intersight.set_tags_and_description()
1145
1146 target_platform = intersight.module.params['target_platform']
1147 api_target_platform = 'FIAttached' if target_platform == 'FIAttached' else 'Standalone'
1148 intersight.api_body['TargetPlatform'] = api_target_platform
1149
1150 # Add FIAttached-specific parameters
1151 if intersight.module.params['target_platform'] == 'FIAttached':
1152 intersight.api_body['AzureQosEnabled'] = intersight.module.params['azure_qos_enabled']
1153 intersight.api_body['IqnAllocationType'] = intersight.module.params['iqn_allocation_type']
1154 intersight.api_body['PlacementMode'] = intersight.module.params['placement_mode']
1155
1156 # Resolve IQN pool MOID if specified
1157 if intersight.module.params['iqn_pool_name']:
1158 iqn_pool_moid = intersight.get_moid_by_name_and_org(
1159 resource_path='/iqnpool/Pools',
1160 resource_name=intersight.module.params['iqn_pool_name'],
1161 organization_name=intersight.module.params['organization']
1162 )
1163 if not iqn_pool_moid:
1164 intersight.module.fail_json(msg=f"IQN Pool '{intersight.module.params['iqn_pool_name']}' not found in organization ' \
1165 {intersight.module.params['organization']}'")
1166 intersight.api_body['IqnPool'] = iqn_pool_moid
1167
1168 if intersight.module.params['static_iqn_name']:
1169 intersight.api_body['StaticIqnName'] = intersight.module.params['static_iqn_name']
1170
1171 intersight.configure_policy_or_profile(resource_path=resource_path)
1172
1173 # Save the LAN connectivity policy response
1174 lan_connectivity_policy_response = intersight.result['api_response']
1175
1176 lan_connectivity_policy_moid = None
1177 if intersight.module.params['state'] == 'present' and lan_connectivity_policy_response:
1178 lan_connectivity_policy_moid = lan_connectivity_policy_response.get('Moid')
1179
1180 # Process vNICs
1181 vnics_response = []
1182 if intersight.module.params['state'] == 'present' and intersight.module.params.get('vnics'):
1183 # Cache for policy MOIDs to avoid redundant API calls
1184 policy_cache = {}
1185
1186 for vnic_config in intersight.module.params['vnics']:
1187 vnic_state = vnic_config.get('state', 'present')
1188
1189 # Only build API body for present vNICs
1190 if vnic_state == 'present':
1191 # Build vNIC API body using helper function
1192 vnic_api_body = build_vnic_api_body(
1193 intersight, policy_cache, module, vnic_config, lan_connectivity_policy_moid
1194 )
1195 intersight.api_body = vnic_api_body
1196
1197 # Configure the vNIC (create/update/delete)
1198 resource_path = '/vnic/EthIfs'
1199 # Filter by both vNIC name AND LAN Connectivity Policy to avoid affecting vNICs in other policies
1200 custom_filter = f"Name eq '{vnic_config['name']}' and LanConnectivityPolicy.Moid eq '{lan_connectivity_policy_moid}'"
1201 intersight.configure_secondary_resource(
1202 resource_path=resource_path,
1203 state=vnic_state,
1204 custom_filter=custom_filter
1205 )
1206
1207 # Save the vNIC response only if it's present
1208 if vnic_state == 'present':
1209 vnics_response.append(intersight.result['api_response'])
1210
1211 # Combine LAN connectivity policy and vNICs in the main response
1212 if lan_connectivity_policy_response:
1213 lan_connectivity_policy_response['vNICs'] = vnics_response
1214 intersight.result['api_response'] = lan_connectivity_policy_response
1215
1216 module.exit_json(**intersight.result)
1217
1218
1219 if __name__ == '__main__':
1220 main()