#!/usr/bin/python # -*- coding: utf-8 -*- # GNU General Public License v3.0+ (see COPYING or https://www.gnu.org/licenses/gpl-3.0.txt) from __future__ import absolute_import, division, print_function __metaclass__ = type ANSIBLE_METADATA = {'metadata_version': '1.1', 'status': ['preview'], 'supported_by': 'community'} DOCUMENTATION = r''' --- module: intersight_lan_connectivity_policy short_description: Manage LAN Connectivity Policies and vNICs for Cisco Intersight description: - Create, update, and delete LAN Connectivity Policies on Cisco Intersight. - Manage individual vNICs within LAN Connectivity policies. - Supports both Standalone and FIAttached target platforms with different configuration options. - LAN Connectivity policies define network connectivity settings for server profiles. - For more information see L(Cisco Intersight,https://intersight.com/apidocs/vnic/LanConnectivityPolicy/get/). extends_documentation_fragment: intersight options: state: description: - If C(present), will verify the resource is present and will create if needed. - If C(absent), will verify the resource is absent and will delete if needed. type: str choices: [present, absent] default: present organization: description: - The name of the Organization this resource is assigned to. - Policies created within a Custom Organization are applicable only to devices in the same Organization. - Use 'default' for the default organization. type: str default: default name: description: - The name assigned to the LAN Connectivity Policy. - Must be unique within the organization. - The name must be between 1 and 62 alphanumeric characters, allowing special characters :-_. type: str required: true description: description: - The user-defined description for the LAN Connectivity Policy. - Description can contain letters(a-z, A-Z), numbers(0-9), hyphen(-), period(.), colon(:), or an underscore(_). type: str aliases: [descr] tags: description: - List of tags in Key: Value: format. type: list elements: dict target_platform: description: - The platform type for which the LAN Connectivity policy is intended. - Standalone for Standalone servers, FIAttached for fabric interconnect attached servers. type: str choices: ['Standalone', 'FIAttached'] default: 'Standalone' azure_qos_enabled: description: - Enable Azure QoS for the LAN Connectivity policy. - Only applicable when target_platform is 'FIAttached'. type: bool default: false iqn_allocation_type: description: - IQN allocation type for the LAN Connectivity policy. - Only applicable when target_platform is 'FIAttached'. type: str choices: ['None', 'Pool', 'Static'] default: 'None' placement_mode: description: - Placement mode for vNIC assignment. - Only applicable when target_platform is 'FIAttached'. type: str choices: ['custom', 'auto'] default: 'custom' iqn_pool_name: description: - Relationship to the iSCSI Qualified Name Pool. - Required when iqn_allocation_type is 'Pool'. - Only applicable for FIAttached target platform. type: str static_iqn_name: description: - User provided static iSCSI Qualified Name (IQN) for use as initiator identifiers by iSCSI vNICs in a Fabric Interconnect domain. - Required when iqn_allocation_type is 'Static'. - Only applicable for FIAttached target platform. type: str vnics: description: - List of vNICs to be created and attached to the LAN Connectivity policy. - Each vNIC will be configured with the specified network and adapter policies. - Required when C(state) is C(present). - At least one vNIC must be specified for both Standalone and FIAttached platforms. type: list elements: dict suboptions: name: description: - The name of the vNIC. - Must be unique within the LAN Connectivity policy. type: str required: true placement_slot_id: description: - PCIe Slot where the VIC adapter is installed. - Supported values are (1-15) and MLOM. - Required when vNIC state is 'present'. type: str uplink_port: description: - Adapter port on which the virtual interface will be created. type: int choices: [0, 1, 2, 3] default: 0 order: description: - The order in which the virtual interface is brought up. - The order assigned to an interface should be unique for all the Ethernet and Fibre-Channel interfaces on each PCI link on a VIC adapter. - The order should start from zero with no overlaps. - The maximum value of PCI order is limited by the number of virtual interfaces (Ethernet and Fibre-Channel) on each PCI link on a VIC adapter. - All VIC adapters have a single PCI link except VIC 1340, VIC 1380 and VIC 1385 which have two. type: int default: 0 cdn_source: description: - Source of the CDN. It can either be user specified or be the same as the vNIC name. type: str choices: ['vnic', 'user'] default: 'vnic' cdn_value: description: - CDN value when cdn_source is 'user'. type: str eth_network_policy_name: description: - Relationship to the Ethernet Network Policy. - Required when vNIC state is 'present'. type: str eth_qos_policy_name: description: - Relationship to the Ethernet QoS Policy. - Required when vNIC state is 'present'. type: str eth_adapter_policy_name: description: - Relationship to the Ethernet Adapter Policy. - Required when vNIC state is 'present'. type: str connection_type: description: - Type of connection for the vNIC. type: str choices: ['none', 'usnic', 'vmq', 'sriov'] default: 'none' mac_address_type: description: - Type of MAC address assignment. - Only applicable for FIAttached target platform. type: str choices: ['pool', 'static'] default: 'pool' mac_pool_name: description: - The MAC pool that is assigned. - Required when mac_address_type is 'pool' and target platform is FIAttached. - Only applicable for FIAttached target platform. type: str static_mac_address: description: - The MAC address must be in hexadecimal format xx:xx:xx:xx:xx:xx. - To ensure uniqueness of MACs in the LAN fabric, you are strongly encouraged to use the following MAC prefix 00:25:B5:xx:xx:xx. - Required when mac_address_type is 'static' and target platform is FIAttached. - Only applicable for FIAttached target platform. type: str pci_link: description: - The PCI Link used as transport for the virtual interface. - PCI Link is only applicable for select Cisco UCS VIC 1300 models (UCSC-PCIE-C40Q-03, UCSB-MLOM-40G-03, UCSB-VIC-M83-8P) that support two PCI links. - The value, if specified, for any other VIC model will be ignored. - For FIAttached required when pci_link_assignment_mode is 'Custom'. type: int choices: [0, 1] default: 0 auto_slot_id: description: - Enable or disable automatic assignment of the VIC slot ID. - If enabled and the server has only one VIC, the same VIC is chosen for all the vNICs. - If enabled and the server has multiple VICs, the vNIC/vHBA are deployed on the first VIC. - If disabled, placement_slot_id must be specified. - Only applicable for FIAttached target platform when auto_vnic_placement_enabled is false. type: bool default: true auto_pci_link: description: - Enable or disable automatic assignment of the PCI Link in a dual-link adapter. - This option applies only to 13xx series VICs that support dual-link. - If enabled, the system determines the placement of the vNIC/vHBA on either of the PCI Links. - If disabled, pci_link_assignment_mode must be specified. - Only applicable for FIAttached target platform when auto_vnic_placement_enabled is false. type: bool default: true pci_link_assignment_mode: description: - PCI Link assignment mode when auto_pci_link is disabled. - Custom allows manual selection of PCI link via pci_link parameter. - Load-Balanced automatically distributes vNICs across available PCI links. - Required when auto_pci_link is false and auto_vnic_placement_enabled is false. - Only applicable for FIAttached target platform. type: str choices: ['Custom', 'Load-Balanced'] auto_vnic_placement_enabled: description: - Enable automatic vNIC placement for FIAttached servers. - When enabled, the vNIC placement is simplified to only specify the switch ID. - When disabled, full placement control is available including order, auto_slot_id, and auto_pci_link. - Only applicable for FIAttached target platform. type: bool default: false switch_id: description: - The fabric port to which the vNICs will be associated. - Only applicable for FIAttached target platform. type: str choices: ['A', 'B'] default: 'A' failover_enabled: description: - Enables automatic vNIC failover to the secondary Fabric Interconnect if the primary path fails. - Failover applies only to Cisco VICs that are connected to a Fabric Interconnect cluster. - Only applicable for FIAttached target platform. type: bool default: false fabric_eth_network_group_policy_name: description: - Relationship to the Fabric Ethernet Group Policy. - Required when target platform is FIAttached and vNIC state is 'present'. - Only applicable for FIAttached target platform. type: str fabric_eth_network_control_policy_name: description: - Relationship to the Fabric Ethernet Network Policy. - Required when target platform is FIAttached and vNIC state is 'present'. - Only applicable for FIAttached target platform. type: str iscsi_boot_policy_name: description: - Relationship to the boot iSCSI Policy. - Only applicable for FIAttached target platform. type: str pin_group_name: description: - Pingroup name associated to vNIC for static pinning. - LCP deploy will resolve pingroup name and fetches the corresponding uplink port/port channel to pin the vNIC traffic. - Only applicable for FIAttached target platform. type: str usnic_settings: description: - USNIC settings when connection_type is 'usnic'. - Required when connection_type is 'usnic'. type: dict suboptions: count: description: - Number of usNIC interfaces to be created. - When usNIC is enabled, the valid values are from 1 to 225. - When usNIC is disabled, the default value is 0. type: int default: 0 cos: description: - Class of Service to be used for traffic on the usNIC. type: int choices: [0, 1, 2, 3, 4, 5, 6] default: 5 usnic_adapter_policy_name: description: - Ethernet Adapter policy to be associated with the usNICs. - Required when connection_type is 'usnic'. type: str vmq_settings: description: - VMQ settings when connection_type is 'vmq'. type: dict suboptions: enabled: description: - Enable VMQ. type: bool default: true multi_queue_support: description: - Enables Virtual Machine Multi-Queue feature on the virtual interface. - VMMQ allows configuration of multiple I/O queues for a single VM and thus distributes traffic across multiple CPU cores in a VM. type: bool default: false num_interrupts: description: - The number of interrupt resources to be allocated. - Recommended value is the number of CPU threads or logical processors available in the server. type: int default: 16 num_vmqs: description: - The number of hardware Virtual Machine Queues to be allocated. - The number of VMQs per adapter must be one more than the maximum number of VM NICs. type: int default: 4 num_sub_vnics: description: - Number of sub vNICs (0-64). - Only applicable when multi_queue_support is true. type: int default: 64 vmmq_adapter_policy_name: description: - Name of the VMMQ Adapter Policy. - Only applicable when multi_queue_support is true. type: str sriov_settings: description: - SR-IOV settings when connection_type is 'sriov'. type: dict suboptions: enabled: description: - Enable SR-IOV. type: bool default: true vf_count: description: - Number of Virtual Functions (1-64). type: int default: 64 rx_count_per_vf: description: - Receive Queue Count per VF (1-8). type: int default: 4 tx_count_per_vf: description: - Transmit Queue Count per VF (1-8). type: int default: 1 comp_count_per_vf: description: - Completion Queue Count per VF (1-16). type: int default: 5 int_count_per_vf: description: - Interrupt Count per VF (1-16). type: int default: 8 state: description: - Whether to create/update or delete the vNIC. type: str choices: ['present', 'absent'] default: present author: - Ron Gershburg (@rgershbu) ''' EXAMPLES = r''' - name: Create a LAN Connectivity Policy for Standalone servers cisco.intersight.intersight_lan_connectivity_policy: api_private_key: "{{ api_private_key }}" api_key_id: "{{ api_key_id }}" organization: "default" name: "Standalone-lan-policy" description: "LAN connectivity policy for Standalone servers" target_platform: "Standalone" tags: - Key: "Environment" Value: "Production" - Key: "Site" Value: "DataCenter-A" vnics: - name: "eth0" placement_slot_id: "1" pci_link: 0 uplink_port: 0 order: 0 eth_network_policy_name: "default-network-policy" eth_qos_policy_name: "default-qos-policy" eth_adapter_policy_name: "default-adapter-policy" connection_type: "none" - name: "eth1" placement_slot_id: "2" pci_link: 0 uplink_port: 1 order: 1 eth_network_policy_name: "vlan-network-policy" eth_qos_policy_name: "high-qos-policy" eth_adapter_policy_name: "performance-adapter-policy" connection_type: "none" state: present - name: Create a LAN Connectivity Policy for FIAttached servers cisco.intersight.intersight_lan_connectivity_policy: api_private_key: "{{ api_private_key }}" api_key_id: "{{ api_key_id }}" organization: "default" name: "fi-attached-lan-policy" description: "LAN connectivity policy for FIAttached servers" target_platform: "FIAttached" azure_qos_enabled: true iqn_allocation_type: "Pool" iqn_pool_name: "default-iqn-pool" placement_mode: "custom" tags: - Key: "Environment" Value: "Production" vnics: - name: "vnic-fi-attached" order: 0 cdn_source: "vnic" mac_address_type: "pool" mac_pool_name: "default-mac-pool" auto_slot_id: true auto_pci_link: true auto_vnic_placement_enabled: false switch_id: "A" failover_enabled: false fabric_eth_network_group_policy_name: "default-network-group" fabric_eth_network_control_policy_name: "default-network-control" eth_qos_policy_name: "default-qos-policy" eth_adapter_policy_name: "default-adapter-policy" connection_type: "none" state: present state: present - name: Create a LAN Connectivity Policy with pin group for static pinning cisco.intersight.intersight_lan_connectivity_policy: api_private_key: "{{ api_private_key }}" api_key_id: "{{ api_key_id }}" organization: "default" name: "fi-attached-pinned-policy" description: "LAN connectivity policy with static uplink pinning" target_platform: "FIAttached" azure_qos_enabled: false iqn_allocation_type: "None" placement_mode: "custom" vnics: - name: "pinned-vnic" order: 0 cdn_source: "vnic" mac_address_type: "pool" mac_pool_name: "default-mac-pool" auto_slot_id: true auto_pci_link: true auto_vnic_placement_enabled: false switch_id: "A" failover_enabled: false fabric_eth_network_group_policy_name: "default-network-group" fabric_eth_network_control_policy_name: "default-network-control" eth_qos_policy_name: "default-qos-policy" eth_adapter_policy_name: "default-adapter-policy" pin_group_name: "pingroup-a" connection_type: "none" state: present state: present - name: Create a LAN Connectivity Policy with automatic vNIC placement cisco.intersight.intersight_lan_connectivity_policy: api_private_key: "{{ api_private_key }}" api_key_id: "{{ api_key_id }}" organization: "default" name: "fi-attached-auto-placement-policy" description: "LAN connectivity policy with automatic vNIC placement" target_platform: "FIAttached" azure_qos_enabled: false iqn_allocation_type: "None" placement_mode: "auto" vnics: - name: "auto-placed-vnic" cdn_source: "vnic" mac_address_type: "pool" mac_pool_name: "default-mac-pool" auto_vnic_placement_enabled: true switch_id: "A" failover_enabled: false fabric_eth_network_group_policy_name: "default-network-group" fabric_eth_network_control_policy_name: "default-network-control" eth_qos_policy_name: "default-qos-policy" eth_adapter_policy_name: "default-adapter-policy" connection_type: "none" state: present state: present - name: Create a LAN Connectivity Policy with advanced placement control cisco.intersight.intersight_lan_connectivity_policy: api_private_key: "{{ api_private_key }}" api_key_id: "{{ api_key_id }}" organization: "default" name: "fi-attached-advanced-placement-policy" description: "LAN connectivity policy with advanced placement control" target_platform: "FIAttached" azure_qos_enabled: false iqn_allocation_type: "None" placement_mode: "custom" vnics: - name: "advanced-placed-vnic" order: 9 cdn_source: "vnic" mac_address_type: "pool" mac_pool_name: "default-mac-pool" auto_slot_id: false placement_slot_id: "5" auto_pci_link: false pci_link_assignment_mode: "Custom" pci_link: 0 auto_vnic_placement_enabled: false switch_id: "A" failover_enabled: false fabric_eth_network_group_policy_name: "default-network-group" fabric_eth_network_control_policy_name: "default-network-control" eth_qos_policy_name: "default-qos-policy" eth_adapter_policy_name: "default-adapter-policy" connection_type: "none" state: present state: present - name: Create a LAN Connectivity Policy with load-balanced PCI assignment cisco.intersight.intersight_lan_connectivity_policy: api_private_key: "{{ api_private_key }}" api_key_id: "{{ api_key_id }}" organization: "default" name: "fi-attached-load-balanced-policy" description: "LAN connectivity policy with load-balanced PCI assignment" target_platform: "FIAttached" azure_qos_enabled: false iqn_allocation_type: "None" placement_mode: "custom" vnics: - name: "load-balanced-vnic" order: 5 cdn_source: "vnic" mac_address_type: "pool" mac_pool_name: "default-mac-pool" auto_slot_id: false placement_slot_id: "MLOM" auto_pci_link: false pci_link_assignment_mode: "Load-Balanced" auto_vnic_placement_enabled: false switch_id: "B" failover_enabled: true fabric_eth_network_group_policy_name: "default-network-group" fabric_eth_network_control_policy_name: "default-network-control" eth_qos_policy_name: "default-qos-policy" eth_adapter_policy_name: "default-adapter-policy" connection_type: "none" state: present state: present - name: Create a LAN Connectivity Policy with USNIC vNIC cisco.intersight.intersight_lan_connectivity_policy: api_private_key: "{{ api_private_key }}" api_key_id: "{{ api_key_id }}" name: "usnic-lan-policy" description: "Policy with USNIC configuration" target_platform: "Standalone" vnics: - name: "usnic-eth0" placement_slot_id: "4" pci_link: 0 uplink_port: 0 order: 0 eth_network_policy_name: "hpc-network-policy" eth_qos_policy_name: "hpc-qos-policy" eth_adapter_policy_name: "hpc-adapter-policy" connection_type: "usnic" usnic_settings: count: 0 cos: 5 usnic_adapter_policy_name: "hpc-adapter-policy" state: present - name: Create a LAN Connectivity Policy with VMQ vNIC cisco.intersight.intersight_lan_connectivity_policy: api_private_key: "{{ api_private_key }}" api_key_id: "{{ api_key_id }}" name: "vmq-lan-policy" description: "Policy with VMQ configuration" target_platform: "Standalone" vnics: - name: "vmq-eth0" placement_slot_id: "10" pci_link: 0 uplink_port: 2 order: 0 eth_network_policy_name: "vm-network-policy" eth_qos_policy_name: "vm-qos-policy" eth_adapter_policy_name: "vm-adapter-policy" connection_type: "vmq" vmq_settings: enabled: true multi_queue_support: false num_interrupts: 16 num_vmqs: 4 state: present - name: Create a LAN Connectivity Policy with VMQ multi-queue support cisco.intersight.intersight_lan_connectivity_policy: api_private_key: "{{ api_private_key }}" api_key_id: "{{ api_key_id }}" name: "vmq-multiqueue-lan-policy" description: "Policy with VMQ multi-queue configuration" target_platform: "Standalone" vnics: - name: "vmq-mq-eth0" placement_slot_id: "11" pci_link: 1 uplink_port: 3 order: 0 eth_network_policy_name: "vm-network-policy" eth_qos_policy_name: "vm-qos-policy" eth_adapter_policy_name: "vm-adapter-policy" connection_type: "vmq" vmq_settings: enabled: true multi_queue_support: true num_sub_vnics: 64 vmmq_adapter_policy_name: "vmmq-adapter-policy" state: present - name: Create a LAN Connectivity Policy with SR-IOV vNIC cisco.intersight.intersight_lan_connectivity_policy: api_private_key: "{{ api_private_key }}" api_key_id: "{{ api_key_id }}" name: "sriov-lan-policy" description: "Policy with SR-IOV configuration" target_platform: "Standalone" vnics: - name: "sriov-eth0" placement_slot_id: "14" pci_link: 0 uplink_port: 1 order: 0 eth_network_policy_name: "sriov-network-policy" eth_qos_policy_name: "sriov-qos-policy" eth_adapter_policy_name: "sriov-adapter-policy" connection_type: "sriov" sriov_settings: enabled: true vf_count: 64 rx_count_per_vf: 4 tx_count_per_vf: 1 comp_count_per_vf: 5 int_count_per_vf: 8 state: present - name: Create a LAN Connectivity Policy with custom CDN values cisco.intersight.intersight_lan_connectivity_policy: api_private_key: "{{ api_private_key }}" api_key_id: "{{ api_key_id }}" name: "custom-cdn-lan-policy" description: "Policy with custom CDN values" target_platform: "Standalone" vnics: - name: "mgmt-nic" placement_slot_id: "1" pci_link: 0 uplink_port: 0 order: 0 cdn_source: "user" cdn_value: "Management-NIC" eth_network_policy_name: "mgmt-network-policy" eth_qos_policy_name: "mgmt-qos-policy" eth_adapter_policy_name: "mgmt-adapter-policy" connection_type: "none" state: present - name: Update LAN connectivity policy - manage vNIC states cisco.intersight.intersight_lan_connectivity_policy: api_private_key: "{{ api_private_key }}" api_key_id: "{{ api_key_id }}" organization: "default" name: "mixed-vnic-states-policy" description: "Policy demonstrating vNIC state management" target_platform: "Standalone" vnics: - name: "eth0" placement_slot_id: "1" pci_link: 0 uplink_port: 0 order: 0 eth_network_policy_name: "production-network" eth_qos_policy_name: "standard-qos" eth_adapter_policy_name: "standard-adapter" connection_type: "none" state: present - name: "eth1-old" state: absent - name: "eth2-new" placement_slot_id: "3" pci_link: 0 uplink_port: 1 order: 1 eth_network_policy_name: "production-network" eth_qos_policy_name: "standard-qos" eth_adapter_policy_name: "standard-adapter" connection_type: "vmq" vmq_settings: enabled: true multi_queue_support: false num_interrupts: 16 num_vmqs: 4 state: present state: present - name: Delete a LAN Connectivity Policy cisco.intersight.intersight_lan_connectivity_policy: api_private_key: "{{ api_private_key }}" api_key_id: "{{ api_key_id }}" name: "old-lan-policy" state: absent ''' RETURN = r''' api_response: description: The API response output returned by the specified resource. returned: always type: dict sample: "api_response": { "Name": "test-lan-policy", "ObjectType": "vnic.LanConnectivityPolicy", "TargetPlatform": "Standalone", "Tags": [ { "Key": "Environment", "Value": "Production" } ], "vNICs": [ { "Name": "eth0", "ObjectType": "vnic.EthIf", "Order": 0, "Placement": { "Id": "1" } } ] } ''' from ansible.module_utils.basic import AnsibleModule from ansible_collections.cisco.intersight.plugins.module_utils.intersight import IntersightModule, intersight_argument_spec from ansible_collections.cisco.intersight.plugins.module_utils.intersight_vnic_utils import ( validate_cdn_config, validate_usnic_settings, validate_vmq_settings, validate_sriov_settings, build_cdn_config, build_connection_settings, resolve_policy_moids_from_mappings, get_common_policy_mappings, get_iscsi_boot_policy_mapping, get_fabric_network_policy_mappings, get_mac_pool_policy_mapping, get_common_settings_argument_spec ) def validate_fi_attached_params(module): """ Validate FIAttached specific parameters """ iqn_allocation_type = module.params.get('iqn_allocation_type') static_iqn_name = module.params.get('static_iqn_name') iqn_pool_name = module.params.get('iqn_pool_name') # Validate IQN allocation type requirements if iqn_allocation_type == 'Static' and not static_iqn_name: module.fail_json(msg="static_iqn_name is required when iqn_allocation_type is 'Static'") if iqn_allocation_type == 'Pool' and not iqn_pool_name: module.fail_json(msg="iqn_pool_name is required when iqn_allocation_type is 'Pool'") if iqn_allocation_type != 'Static' and static_iqn_name: module.fail_json(msg="static_iqn_name should only be specified when iqn_allocation_type is 'Static'") if iqn_allocation_type != 'Pool' and iqn_pool_name: module.fail_json(msg="iqn_pool_name should only be specified when iqn_allocation_type is 'Pool'") def validate_fi_attached_vnic_config(module, vnic_config): """ Validate FIAttached specific vNIC configuration """ vnic_name = vnic_config.get('name', 'unknown') mac_address_type = vnic_config.get('mac_address_type', 'pool') mac_pool_name = vnic_config.get('mac_pool_name') static_mac_address = vnic_config.get('static_mac_address') # Validate MAC address configuration if mac_address_type == 'pool' and not mac_pool_name: module.fail_json(msg=f"mac_pool_name is required when mac_address_type is 'pool' for vNIC '{vnic_name}'") if mac_address_type == 'static' and not static_mac_address: module.fail_json(msg=f"static_mac_address is required when mac_address_type is 'static' for vNIC '{vnic_name}'") if mac_address_type != 'pool' and mac_pool_name: module.fail_json(msg=f"mac_pool_name should only be specified when mac_address_type is 'pool' for vNIC '{vnic_name}'") if mac_address_type != 'static' and static_mac_address: module.fail_json(msg=f"static_mac_address should only be specified when mac_address_type is 'static' for vNIC '{vnic_name}'") # Validate required FIAttached fields fabric_eth_network_group_policy_name = vnic_config.get('fabric_eth_network_group_policy_name') fabric_eth_network_control_policy_name = vnic_config.get('fabric_eth_network_control_policy_name') if not fabric_eth_network_group_policy_name: module.fail_json(msg=f"fabric_eth_network_group_policy_name is required for attached vNIC '{vnic_name}'") if not fabric_eth_network_control_policy_name: module.fail_json(msg=f"fabric_eth_network_control_policy_name is required for attached vNIC '{vnic_name}'") # Validate advanced placement configuration validate_fi_attached_placement_config(module, vnic_config) def validate_fi_attached_placement_config(module, vnic_config): """ Validate FIAttached placement configuration """ vnic_name = vnic_config.get('name', 'unknown') auto_vnic_placement_enabled = vnic_config.get('auto_vnic_placement_enabled', False) # Skip advanced placement validation if auto placement is enabled if auto_vnic_placement_enabled: return auto_slot_id = vnic_config.get('auto_slot_id', True) placement_slot_id = vnic_config.get('placement_slot_id') auto_pci_link = vnic_config.get('auto_pci_link', True) pci_link_assignment_mode = vnic_config.get('pci_link_assignment_mode') pci_link = vnic_config.get('pci_link') # Validate slot ID configuration if not auto_slot_id and not placement_slot_id: module.fail_json(msg=f"placement_slot_id is required when auto_slot_id is false for vNIC '{vnic_name}'") if auto_slot_id and placement_slot_id: module.fail_json(msg=f"placement_slot_id should not be specified when auto_slot_id is true for vNIC '{vnic_name}'") # Validate PCI link configuration if not auto_pci_link and not pci_link_assignment_mode: module.fail_json(msg=f"pci_link_assignment_mode is required when auto_pci_link is false for vNIC '{vnic_name}'") if auto_pci_link and pci_link_assignment_mode: module.fail_json(msg=f"pci_link_assignment_mode should not be specified when auto_pci_link is true for vNIC '{vnic_name}'") # Validate PCI link when using Custom mode if pci_link_assignment_mode == 'Custom' and pci_link is None: module.fail_json(msg=f"pci_link is required when pci_link_assignment_mode is 'Custom' for vNIC '{vnic_name}'") if pci_link_assignment_mode != 'Custom' and pci_link is not None and pci_link != 0: module.fail_json(msg=f"pci_link should only be specified when pci_link_assignment_mode is 'Custom' for vNIC '{vnic_name}'") def validate_standalone_vnic_config(module, vnic_config): """ Validate Standalone specific vNIC configuration """ vnic_name = vnic_config.get('name', 'unknown') # Validate required Standalone fields placement_slot_id = vnic_config.get('placement_slot_id') eth_network_policy_name = vnic_config.get('eth_network_policy_name') if not placement_slot_id: module.fail_json(msg=f"placement_slot_id is required for Standalone vNIC '{vnic_name}'") if not eth_network_policy_name: module.fail_json(msg=f"eth_network_policy_name is required for Standalone vNIC '{vnic_name}'") def get_vnic_policy_mappings(target_platform, vnic_config): """ Get policy mappings for vNIC configuration based on target platform. """ # Start with common policies policy_mappings = get_common_policy_mappings() # Platform-specific policies if target_platform == 'FIAttached': # Add fabric network policies policy_mappings.update(get_fabric_network_policy_mappings()) # MAC pool for FIAttached when using pool type if vnic_config.get('mac_address_type', 'pool') == 'pool': policy_mappings.update(get_mac_pool_policy_mapping()) # iSCSI boot policy if vnic_config.get('iscsi_boot_policy_name'): policy_mappings.update(get_iscsi_boot_policy_mapping()) else: # Standalone server policy_mappings['eth_network_policy_name'] = ('/vnic/EthNetworkPolicies', 'EthNetworkPolicy', 'Ethernet Network Policy') return policy_mappings def resolve_vnic_policy_moids(intersight, policy_cache, module, vnic_config, target_platform): """ Resolve all policy MOIDs for a vNIC configuration based on target platform. """ policy_mappings = get_vnic_policy_mappings(target_platform, vnic_config) organization_name = module.params['organization'] return resolve_policy_moids_from_mappings(intersight, policy_cache, module, vnic_config, policy_mappings, organization_name) def build_vnic_api_body(intersight, policy_cache, module, vnic_config, lan_connectivity_policy_moid): """ Build vNIC API body for API call """ target_platform = module.params.get('target_platform') if target_platform == 'FIAttached': return build_fi_attached_vnic_api_body(intersight, policy_cache, module, vnic_config, lan_connectivity_policy_moid) else: return build_standalone_vnic_api_body(intersight, policy_cache, module, vnic_config, lan_connectivity_policy_moid) def build_standalone_vnic_api_body(intersight, policy_cache, module, vnic_config, lan_connectivity_policy_moid): """ Build Standalone vNIC API body for Intersight API call """ # Base vNIC configuration for Standalone vnic_api_body = { 'Name': vnic_config['name'], 'Placement': { 'Id': vnic_config['placement_slot_id'], 'Uplink': vnic_config.get('uplink_port', 0), 'PciLink': vnic_config.get('pci_link', 0) }, 'Order': vnic_config.get('order', 0), 'LanConnectivityPolicy': lan_connectivity_policy_moid } # Add common CDN configuration vnic_api_body['Cdn'] = build_cdn_config(vnic_config) # Resolve and add policy MOIDs policy_moids = resolve_vnic_policy_moids(intersight, policy_cache, module, vnic_config, 'Standalone') vnic_api_body.update(policy_moids) # Add common connection type settings organization_name = module.params['organization'] connection_settings = build_connection_settings(intersight, policy_cache, module, vnic_config, organization_name) vnic_api_body.update(connection_settings) return vnic_api_body def build_fi_attached_vnic_api_body(intersight, policy_cache, module, vnic_config, lan_connectivity_policy_moid): """ Build FIAttached vNIC API body for Intersight API call """ # Base vNIC configuration for FIAttached # Map lowercase user input to API format mac_address_type = vnic_config.get('mac_address_type', 'pool') api_mac_address_type = 'STATIC' if mac_address_type == 'static' else 'POOL' auto_vnic_placement_enabled = vnic_config.get('auto_vnic_placement_enabled', False) vnic_api_body = { 'Name': vnic_config['name'], 'MacAddressType': api_mac_address_type, 'FailoverEnabled': vnic_config.get('failover_enabled', False), 'LanConnectivityPolicy': lan_connectivity_policy_moid } # Handle placement based on auto_vnic_placement_enabled if auto_vnic_placement_enabled: vnic_api_body['Placement'] = { 'SwitchId': vnic_config.get('switch_id', 'A'), 'AutoSlotId': True, 'AutoPciLink': True } else: # Full placement control placement = { 'SwitchId': vnic_config.get('switch_id', 'A'), 'AutoSlotId': vnic_config.get('auto_slot_id', True), 'AutoPciLink': vnic_config.get('auto_pci_link', True) } # Add slot ID if auto_slot_id is disabled if not vnic_config.get('auto_slot_id', True): placement['Id'] = vnic_config['placement_slot_id'] # Add PCI link configuration if auto_pci_link is disabled if not vnic_config.get('auto_pci_link', True): placement['PciLinkAssignmentMode'] = vnic_config['pci_link_assignment_mode'] if vnic_config['pci_link_assignment_mode'] == 'Custom': placement['PciLink'] = vnic_config.get('pci_link', 0) vnic_api_body['Placement'] = placement vnic_api_body['Order'] = vnic_config.get('order', 0) # Add common CDN configuration vnic_api_body['Cdn'] = build_cdn_config(vnic_config) # Add static MAC address if using static type if mac_address_type == 'static': vnic_api_body['StaticMacAddress'] = vnic_config['static_mac_address'] # Resolve and add policy MOIDs policy_moids = resolve_vnic_policy_moids(intersight, policy_cache, module, vnic_config, 'FIAttached') vnic_api_body.update(policy_moids) # Add common connection type settings organization_name = module.params['organization'] connection_settings = build_connection_settings(intersight, policy_cache, module, vnic_config, organization_name) vnic_api_body.update(connection_settings) # Add pin group name if specified if vnic_config.get('pin_group_name'): vnic_api_body['PinGroupName'] = vnic_config['pin_group_name'] return vnic_api_body def validate_input(module): """ Validate module input parameters """ # Validate FIAttached specific requirements target_platform = module.params.get('target_platform') if target_platform == 'FIAttached': validate_fi_attached_params(module) # Validate vNIC configurations vnics = module.params.get('vnics', []) for vnic_config in vnics: vnic_name = vnic_config.get('name') vnic_state = vnic_config.get('state', 'present') # Only validate present vNICs - absent vNICs only need name if vnic_state == 'present': # Validate common required fields required_fields = ['eth_qos_policy_name', 'eth_adapter_policy_name'] for field in required_fields: if not vnic_config.get(field): module.fail_json(msg=f"{field} is required when vNIC state is 'present' for vNIC '{vnic_name}'") # Validate target platform specific fields target_platform = module.params.get('target_platform') if target_platform == 'FIAttached': validate_fi_attached_vnic_config(module, vnic_config) else: validate_standalone_vnic_config(module, vnic_config) # Validate CDN configuration validate_cdn_config(module, vnic_config) connection_type = vnic_config.get('connection_type', 'none') # Validate connection type specific settings vnic_name = vnic_config.get('name', 'unknown') if connection_type == 'usnic': usnic_settings = vnic_config.get('usnic_settings') validate_usnic_settings(module, usnic_settings, vnic_name) elif connection_type == 'vmq': vmq_settings = vnic_config.get('vmq_settings', {}) validate_vmq_settings(module, vmq_settings, vnic_name) elif connection_type == 'sriov': sriov_settings = vnic_config.get('sriov_settings', {}) validate_sriov_settings(module, sriov_settings, vnic_name) def main(): # Define vNIC options vnic_options = dict( name=dict(type='str', required=True), state=dict(type='str', choices=['present', 'absent'], default='present'), placement_slot_id=dict(type='str'), pci_link=dict(type='int', choices=[0, 1], default=0), uplink_port=dict(type='int', choices=[0, 1, 2, 3], default=0), order=dict(type='int', default=0), eth_network_policy_name=dict(type='str'), eth_qos_policy_name=dict(type='str'), eth_adapter_policy_name=dict(type='str'), mac_address_type=dict(type='str', choices=['pool', 'static'], default='pool'), static_mac_address=dict(type='str'), auto_slot_id=dict(type='bool', default=True), auto_pci_link=dict(type='bool', default=True), pci_link_assignment_mode=dict(type='str', choices=['Custom', 'Load-Balanced']), auto_vnic_placement_enabled=dict(type='bool', default=False), pin_group_name=dict(type='str'), ) # Add connection settings argument specs vnic_options.update(get_common_settings_argument_spec()) argument_spec = intersight_argument_spec.copy() argument_spec.update( state=dict(type='str', choices=['present', 'absent'], default='present'), organization=dict(type='str', default='default'), name=dict(type='str', required=True), description=dict(type='str', aliases=['descr']), tags=dict(type='list', elements='dict'), target_platform=dict(type='str', choices=['Standalone', 'FIAttached'], default='Standalone'), azure_qos_enabled=dict(type='bool', default=False), iqn_allocation_type=dict(type='str', choices=['None', 'Pool', 'Static'], default='None'), placement_mode=dict(type='str', choices=['custom', 'auto'], default='custom'), iqn_pool_name=dict(type='str'), static_iqn_name=dict(type='str'), vnics=dict(type='list', elements='dict', options=vnic_options) ) required_if = [ ['state', 'present', ['vnics']], ] module = AnsibleModule( argument_spec, required_if=required_if, supports_check_mode=True, ) if module.params['state'] == 'present': validate_input(module) intersight = IntersightModule(module) intersight.result['api_response'] = {} intersight.result['trace_id'] = '' # Resource path used to configure policy resource_path = '/vnic/LanConnectivityPolicies' # Define API body used in compares or create intersight.api_body = { 'Organization': { 'Name': intersight.module.params['organization'], }, 'Name': intersight.module.params['name'] } if intersight.module.params['state'] == 'present': intersight.set_tags_and_description() target_platform = intersight.module.params['target_platform'] api_target_platform = 'FIAttached' if target_platform == 'FIAttached' else 'Standalone' intersight.api_body['TargetPlatform'] = api_target_platform # Add FIAttached-specific parameters if intersight.module.params['target_platform'] == 'FIAttached': intersight.api_body['AzureQosEnabled'] = intersight.module.params['azure_qos_enabled'] intersight.api_body['IqnAllocationType'] = intersight.module.params['iqn_allocation_type'] intersight.api_body['PlacementMode'] = intersight.module.params['placement_mode'] # Resolve IQN pool MOID if specified if intersight.module.params['iqn_pool_name']: iqn_pool_moid = intersight.get_moid_by_name_and_org( resource_path='/iqnpool/Pools', resource_name=intersight.module.params['iqn_pool_name'], organization_name=intersight.module.params['organization'] ) if not iqn_pool_moid: intersight.module.fail_json(msg=f"IQN Pool '{intersight.module.params['iqn_pool_name']}' not found in organization ' \ {intersight.module.params['organization']}'") intersight.api_body['IqnPool'] = iqn_pool_moid if intersight.module.params['static_iqn_name']: intersight.api_body['StaticIqnName'] = intersight.module.params['static_iqn_name'] intersight.configure_policy_or_profile(resource_path=resource_path) # Save the LAN connectivity policy response lan_connectivity_policy_response = intersight.result['api_response'] lan_connectivity_policy_moid = None if intersight.module.params['state'] == 'present' and lan_connectivity_policy_response: lan_connectivity_policy_moid = lan_connectivity_policy_response.get('Moid') # Process vNICs vnics_response = [] if intersight.module.params['state'] == 'present' and intersight.module.params.get('vnics'): # Cache for policy MOIDs to avoid redundant API calls policy_cache = {} for vnic_config in intersight.module.params['vnics']: vnic_state = vnic_config.get('state', 'present') # Only build API body for present vNICs if vnic_state == 'present': # Build vNIC API body using helper function vnic_api_body = build_vnic_api_body( intersight, policy_cache, module, vnic_config, lan_connectivity_policy_moid ) intersight.api_body = vnic_api_body # Configure the vNIC (create/update/delete) resource_path = '/vnic/EthIfs' # Filter by both vNIC name AND LAN Connectivity Policy to avoid affecting vNICs in other policies custom_filter = f"Name eq '{vnic_config['name']}' and LanConnectivityPolicy.Moid eq '{lan_connectivity_policy_moid}'" intersight.configure_secondary_resource( resource_path=resource_path, state=vnic_state, custom_filter=custom_filter ) # Save the vNIC response only if it's present if vnic_state == 'present': vnics_response.append(intersight.result['api_response']) # Combine LAN connectivity policy and vNICs in the main response if lan_connectivity_policy_response: lan_connectivity_policy_response['vNICs'] = vnics_response intersight.result['api_response'] = lan_connectivity_policy_response module.exit_json(**intersight.result) if __name__ == '__main__': main()