Debian Codegraph @

docs/html/cl-manual.html

raw
1 <html>
2 <head>
3 <meta http-equiv="Content-Type" content="text/html; charset=UTF-8">
4 <title>6. Callgrind: a call-graph generating cache and branch prediction profiler</title>
5 <link rel="stylesheet" type="text/css" href="vg_basic.css">
6 <meta name="generator" content="DocBook XSL Stylesheets Vsnapshot">
7 <link rel="home" href="index.html" title="Valgrind Documentation">
8 <link rel="up" href="manual.html" title="Valgrind User Manual">
9 <link rel="prev" href="cg-manual.html" title="5. Cachegrind: a high-precision tracing profiler">
10 <link rel="next" href="hg-manual.html" title="7. Helgrind: a thread error detector">
11 </head>
12 <body bgcolor="white" text="black" link="#0000FF" vlink="#840084" alink="#0000FF">
13 <div><table class="nav" width="100%" cellspacing="3" cellpadding="3" border="0" summary="Navigation header"><tr>
14 <td width="22px" align="center" valign="middle"><a accesskey="p" href="cg-manual.html"><img src="images/prev.png" width="18" height="21" border="0" alt="Prev"></a></td>
15 <td width="25px" align="center" valign="middle"><a accesskey="u" href="manual.html"><img src="images/up.png" width="21" height="18" border="0" alt="Up"></a></td>
16 <td width="31px" align="center" valign="middle"><a accesskey="h" href="index.html"><img src="images/home.png" width="27" height="20" border="0" alt="Up"></a></td>
17 <th align="center" valign="middle">Valgrind User Manual</th>
18 <td width="22px" align="center" valign="middle"><a accesskey="n" href="hg-manual.html"><img src="images/next.png" width="18" height="21" border="0" alt="Next"></a></td>
19 </tr></table></div>
20 <div class="chapter">
21 <div class="titlepage"><div><div><h1 class="title">
22 <a name="cl-manual"></a>6. Callgrind: a call-graph generating cache and branch prediction profiler</h1></div></div></div>
23 <div class="toc">
24 <p><b>Table of Contents</b></p>
25 <dl class="toc">
26 <dt><span class="sect1"><a href="cl-manual.html#cl-manual.use">6.1. Overview</a></span></dt>
27 <dd><dl>
28 <dt><span class="sect2"><a href="cl-manual.html#cl-manual.functionality">6.1.1. Functionality</a></span></dt>
29 <dt><span class="sect2"><a href="cl-manual.html#cl-manual.basics">6.1.2. Basic Usage</a></span></dt>
30 </dl></dd>
31 <dt><span class="sect1"><a href="cl-manual.html#cl-manual.usage">6.2. Advanced Usage</a></span></dt>
32 <dd><dl>
33 <dt><span class="sect2"><a href="cl-manual.html#cl-manual.dumps">6.2.1. Multiple profiling dumps from one program run</a></span></dt>
34 <dt><span class="sect2"><a href="cl-manual.html#cl-manual.limits">6.2.2. Limiting the range of collected events</a></span></dt>
35 <dt><span class="sect2"><a href="cl-manual.html#cl-manual.busevents">6.2.3. Counting global bus events</a></span></dt>
36 <dt><span class="sect2"><a href="cl-manual.html#cl-manual.cycles">6.2.4. Avoiding cycles</a></span></dt>
37 <dt><span class="sect2"><a href="cl-manual.html#cl-manual.forkingprograms">6.2.5. Forking Programs</a></span></dt>
38 </dl></dd>
39 <dt><span class="sect1"><a href="cl-manual.html#cl-manual.options">6.3. Callgrind Command-line Options</a></span></dt>
40 <dd><dl>
41 <dt><span class="sect2"><a href="cl-manual.html#cl-manual.options.creation">6.3.1. Dump creation options</a></span></dt>
42 <dt><span class="sect2"><a href="cl-manual.html#cl-manual.options.activity">6.3.2. Activity options</a></span></dt>
43 <dt><span class="sect2"><a href="cl-manual.html#cl-manual.options.collection">6.3.3. Data collection options</a></span></dt>
44 <dt><span class="sect2"><a href="cl-manual.html#cl-manual.options.separation">6.3.4. Cost entity separation options</a></span></dt>
45 <dt><span class="sect2"><a href="cl-manual.html#cl-manual.options.simulation">6.3.5. Simulation options</a></span></dt>
46 <dt><span class="sect2"><a href="cl-manual.html#cl-manual.options.cachesimulation">6.3.6. Cache simulation options</a></span></dt>
47 </dl></dd>
48 <dt><span class="sect1"><a href="cl-manual.html#cl-manual.monitor-commands">6.4. Callgrind Monitor Commands</a></span></dt>
49 <dt><span class="sect1"><a href="cl-manual.html#cl-manual.clientrequests">6.5. Callgrind specific client requests</a></span></dt>
50 <dt><span class="sect1"><a href="cl-manual.html#cl-manual.callgrind_annotate-options">6.6. callgrind_annotate Command-line Options</a></span></dt>
51 <dt><span class="sect1"><a href="cl-manual.html#cl-manual.callgrind_control-options">6.7. callgrind_control Command-line Options</a></span></dt>
52 </dl>
53 </div>
54 <p>To use this tool, you must specify
55 <code class="option">--tool=callgrind</code> on the
56 Valgrind command line.</p>
57 <div class="sect1">
58 <div class="titlepage"><div><div><h2 class="title" style="clear: both">
59 <a name="cl-manual.use"></a>6.1. Overview</h2></div></div></div>
60 <p>Callgrind is a profiling tool that records the call history among
61 functions in a program's run as a call-graph.
62 By default, the collected data consists of
63 the number of instructions executed, their relationship
64 to source lines, the caller/callee relationship between functions,
65 and the numbers of such calls.
66 Optionally, cache simulation and/or branch prediction (similar to Cachegrind)
67 can produce further information about the runtime behavior of an application.
68 </p>
69 <p>The profile data is written out to a file at program
70 termination. For presentation of the data, and interactive control
71 of the profiling, two command line tools are provided:</p>
72 <div class="variablelist"><dl class="variablelist">
73 <dt><span class="term"><span class="command"><strong>callgrind_annotate</strong></span></span></dt>
74 <dd>
75 <p>This command reads in the profile data, and prints a
76 sorted lists of functions, optionally with source annotation.</p>
77 <p>For graphical visualization of the data, try
78 <a class="ulink" href="https://kcachegrind.github.io/html/Home.html" target="_top">KCachegrind</a>, which is a KDE/Qt based
79 GUI that makes it easy to navigate the large amount of data that
80 Callgrind produces.</p>
81 </dd>
82 <dt><span class="term"><span class="command"><strong>callgrind_control</strong></span></span></dt>
83 <dd><p>This command enables you to interactively observe and control
84 the status of a program currently running under Callgrind's control,
85 without stopping the program. You can get statistics information as
86 well as the current stack trace, and you can request zeroing of counters
87 or dumping of profile data.</p></dd>
88 </dl></div>
89 <div class="sect2">
90 <div class="titlepage"><div><div><h3 class="title">
91 <a name="cl-manual.functionality"></a>6.1.1. Functionality</h3></div></div></div>
92 <p>Cachegrind collects flat profile data: event counts (data reads,
93 cache misses, etc.) are attributed directly to the function they
94 occurred in. This cost attribution mechanism is
95 called <span class="emphasis"><em>self</em></span> or <span class="emphasis"><em>exclusive</em></span>
96 attribution.</p>
97 <p>Callgrind extends this functionality by propagating costs
98 across function call boundaries. If function <code class="function">foo</code> calls
99 <code class="function">bar</code>, the costs from <code class="function">bar</code> are added into
100 <code class="function">foo</code>'s costs. When applied to the program as a whole,
101 this builds up a picture of so called <span class="emphasis"><em>inclusive</em></span>
102 costs, that is, where the cost of each function includes the costs of
103 all functions it called, directly or indirectly.</p>
104 <p>As an example, the inclusive cost of
105 <code class="function">main</code> should be almost 100 percent
106 of the total program cost. Because of costs arising before
107 <code class="function">main</code> is run, such as
108 initialization of the run time linker and construction of global C++
109 objects, the inclusive cost of <code class="function">main</code>
110 is not exactly 100 percent of the total program cost.</p>
111 <p>Together with the call graph, this allows you to find the
112 specific call chains starting from
113 <code class="function">main</code> in which the majority of the
114 program's costs occur. Caller/callee cost attribution is also useful
115 for profiling functions called from multiple call sites, and where
116 optimization opportunities depend on changing code in the callers, in
117 particular by reducing the call count.</p>
118 <p>Callgrind's cache simulation is based on that of Cachegrind.
119 Read the documentation for <a class="xref" href="cg-manual.html" title="5. Cachegrind: a high-precision tracing profiler">Cachegrind: a cache and branch-prediction profiler</a> first. The material
120 below describes the features supported in addition to Cachegrind's
121 features.</p>
122 <p>Callgrind's ability to detect function calls and returns depends
123 on the instruction set of the platform it is run on. It works best on
124 x86 and amd64, and unfortunately currently does not work so well on
125 PowerPC, ARM, Thumb or MIPS code. This is because there are no explicit
126 call or return instructions in these instruction sets, so Callgrind
127 has to rely on heuristics to detect calls and returns.</p>
128 </div>
129 <div class="sect2">
130 <div class="titlepage"><div><div><h3 class="title">
131 <a name="cl-manual.basics"></a>6.1.2. Basic Usage</h3></div></div></div>
132 <p>As with Cachegrind, you probably want to compile with debugging info
133 (the <code class="option">-g</code> option) and with optimization turned on.</p>
134 <p>To start a profile run for a program, execute:
135 </p>
136 <pre class="screen">valgrind --tool=callgrind [callgrind options] your-program [program options]</pre>
137 <p>
138 </p>
139 <p>While the simulation is running, you can observe execution with:
140 </p>
141 <pre class="screen">callgrind_control -b</pre>
142 <p>
143 This will print out the current backtrace. To annotate the backtrace with
144 event counts, run
145 </p>
146 <pre class="screen">callgrind_control -e -b</pre>
147 <p>
148 </p>
149 <p>After program termination, a profile data file named
150 <code class="computeroutput">callgrind.out.&lt;pid&gt;</code>
151 is generated, where <span class="emphasis"><em>pid</em></span> is the process ID
152 of the program being profiled.
153 The data file contains information about the calls made in the
154 program among the functions executed, together with
155 <span class="command"><strong>Instruction Read</strong></span> (Ir) event counts.</p>
156 <p>To generate a function-by-function summary from the profile
157 data file, use
158 </p>
159 <pre class="screen">callgrind_annotate [options] callgrind.out.&lt;pid&gt;</pre>
160 <p>
161 This summary is similar to the output you get from a Cachegrind
162 run with cg_annotate: the list
163 of functions is ordered by exclusive cost of functions, which also
164 are the ones that are shown.
165 Important for the additional features of Callgrind are
166 the following two options:</p>
167 <div class="itemizedlist"><ul class="itemizedlist" style="list-style-type: disc; ">
168 <li class="listitem"><p><code class="option">--inclusive=yes</code>: Instead of using
169 exclusive cost of functions as sorting order, use and show
170 inclusive cost.</p></li>
171 <li class="listitem"><p><code class="option">--tree=both</code>: Interleave into the
172 top level list of functions, information on the callers and the callees
173 of each function. In these lines, which represents executed
174 calls, the cost gives the number of events spent in the call.
175 Indented, above each function, there is the list of callers,
176 and below, the list of callees. The sum of events in calls to
177 a given function (caller lines), as well as the sum of events in
178 calls from the function (callee lines) together with the self
179 cost, gives the total inclusive cost of the function.</p></li>
180 </ul></div>
181 <p>By default, you will also get annotated source code
182 for all relevant functions for which the source can be found. In
183 addition to source annotation as produced by
184 <code class="computeroutput">cg_annotate</code>, you will see the
185 annotated call sites with call counts. For all other options,
186 consult the (Cachegrind) documentation for
187 <code class="computeroutput">cg_annotate</code>.
188 </p>
189 <p>For better call graph browsing experience, it is highly recommended
190 to use <a class="ulink" href="https://kcachegrind.github.io/html/Home.html" target="_top">KCachegrind</a>.
191 If your code
192 has a significant fraction of its cost in <span class="emphasis"><em>cycles</em></span> (sets
193 of functions calling each other in a recursive manner), you have to
194 use KCachegrind, as <code class="computeroutput">callgrind_annotate</code>
195 currently does not do any cycle detection, which is important to get correct
196 results in this case.</p>
197 <p>If you are additionally interested in measuring the
198 cache behavior of your program, use Callgrind with the option
199 <code class="option"><a class="link" href="cl-manual.html#clopt.cache-sim">--cache-sim=yes</a></code>.
200 For branch prediction simulation, use
201 <code class="option"><a class="link" href="cl-manual.html#clopt.branch-sim">--branch-sim=yes</a></code>.
202 Expect a further slow down approximately by a factor of 2.</p>
203 <p>If the program section you want to profile is somewhere in the
204 middle of the run, it is beneficial to
205 <span class="emphasis"><em>fast forward</em></span> to this section without any
206 profiling, and then enable profiling. This is achieved by using
207 the command line option
208 <code class="option"><a class="link" href="cl-manual.html#opt.instr-atstart">--instr-atstart=no</a></code>
209 and running, in a shell:
210 <code class="computeroutput">callgrind_control -i on</code> just before the
211 interesting code section is executed. To exactly specify
212 the code position where profiling should start, use the client request
213 <code class="computeroutput"><a class="link" href="cl-manual.html#cr.start-instr">CALLGRIND_START_INSTRUMENTATION</a></code>.</p>
214 <p>If you want to be able to see assembly code level annotation, specify
215 <code class="option"><a class="link" href="cl-manual.html#opt.dump-instr">--dump-instr=yes</a></code>.
216 This will produce profile data at instruction granularity.
217 Note that the resulting profile data
218 can only be viewed with KCachegrind. For assembly annotation, it also is
219 interesting to see more details of the control flow inside of functions,
220 i.e. (conditional) jumps. This will be collected by further specifying
221 <code class="option"><a class="link" href="cl-manual.html#opt.collect-jumps">--collect-jumps=yes</a></code>.
222 </p>
223 </div>
224 </div>
225 <div class="sect1">
226 <div class="titlepage"><div><div><h2 class="title" style="clear: both">
227 <a name="cl-manual.usage"></a>6.2. Advanced Usage</h2></div></div></div>
228 <div class="sect2">
229 <div class="titlepage"><div><div><h3 class="title">
230 <a name="cl-manual.dumps"></a>6.2.1. Multiple profiling dumps from one program run</h3></div></div></div>
231 <p>Sometimes you are not interested in characteristics of a full
232 program run, but only of a small part of it, for example execution of one
233 algorithm. If there are multiple algorithms, or one algorithm
234 running with different input data, it may even be useful to get different
235 profile information for different parts of a single program run.</p>
236 <p>Profile data files have names of the form
237 </p>
238 <pre class="screen">
239 callgrind.out.<span class="emphasis"><em>pid</em></span>.<span class="emphasis"><em>part</em></span>-<span class="emphasis"><em>threadID</em></span>
240 </pre>
241 <p>
242 </p>
243 <p>where <span class="emphasis"><em>pid</em></span> is the PID of the running
244 program, <span class="emphasis"><em>part</em></span> is a number incremented on each
245 dump (".part" is skipped for the dump at program termination), and
246 <span class="emphasis"><em>threadID</em></span> is a thread identification
247 ("-threadID" is only used if you request dumps of individual
248 threads with
249 <code class="option"><a class="link" href="cl-manual.html#opt.separate-threads">--separate-threads=yes</a></code>).
250 </p>
251 <p>There are different ways to generate multiple profile dumps
252 while a program is running under Callgrind's supervision. Nevertheless,
253 all methods trigger the same action, which is "dump all profile
254 information since the last dump or program start, and zero cost
255 counters afterwards". To allow for zeroing cost counters without
256 dumping, there is a second action "zero all cost counters now".
257 The different methods are:</p>
258 <div class="itemizedlist"><ul class="itemizedlist" style="list-style-type: disc; ">
259 <li class="listitem"><p><span class="command"><strong>Dump on program termination.</strong></span>
260 This method is the standard way and doesn't need any special
261 action on your part.</p></li>
262 <li class="listitem">
263 <p><span class="command"><strong>Spontaneous, interactive dumping.</strong></span> Use
264 </p>
265 <pre class="screen">callgrind_control -d [hint [PID/Name]]</pre>
266 <p> to
267 request the dumping of profile information of the supervised
268 application with PID or Name. <span class="emphasis"><em>hint</em></span> is an
269 arbitrary string you can optionally specify to later be able to
270 distinguish profile dumps. The control program will not terminate
271 before the dump is completely written. Note that the application
272 must be actively running for detection of the dump command. So,
273 for a GUI application, resize the window, or for a server, send a
274 request.</p>
275 <p>If you are using <a class="ulink" href="https://kcachegrind.github.io/html/Home.html" target="_top">KCachegrind</a>
276 for browsing of profile information, you can use the toolbar
277 button <span class="command"><strong>Force dump</strong></span>. This will request a dump
278 and trigger a reload after the dump is written.</p>
279 </li>
280 <li class="listitem"><p><span class="command"><strong>Periodic dumping after execution of a specified
281 number of basic blocks</strong></span>. For this, use the command line
282 option <code class="option"><a class="link" href="cl-manual.html#opt.dump-every-bb">--dump-every-bb=count</a></code>.
283 </p></li>
284 <li class="listitem">
285 <p><span class="command"><strong>Dumping at enter/leave of specified functions.</strong></span>
286 Use the
287 option <code class="option"><a class="link" href="cl-manual.html#opt.dump-before">--dump-before=function</a></code>
288 and <code class="option"><a class="link" href="cl-manual.html#opt.dump-after">--dump-after=function</a></code>.
289 To zero cost counters before entering a function, use
290 <code class="option"><a class="link" href="cl-manual.html#opt.zero-before">--zero-before=function</a></code>.</p>
291 <p>You can specify these options multiple times for different
292 functions. Function specifications support wildcards: e.g. use
293 <code class="option"><a class="link" href="cl-manual.html#opt.dump-before">--dump-before='foo*'</a></code> to
294 generate dumps before entering any function starting with
295 <span class="emphasis"><em>foo</em></span>.</p>
296 </li>
297 <li class="listitem"><p><span class="command"><strong>Program controlled dumping.</strong></span>
298 Insert
299 <code class="computeroutput"><a class="link" href="cl-manual.html#cr.dump-stats">CALLGRIND_DUMP_STATS</a>;</code>
300 at the position in your code where you want a profile dump to
301 happen. Use
302 <code class="computeroutput"><a class="link" href="cl-manual.html#cr.zero-stats">CALLGRIND_ZERO_STATS</a>;</code> to only
303 zero profile counters.
304 See <a class="xref" href="cl-manual.html#cl-manual.clientrequests" title="6.5. Callgrind specific client requests">Client request reference</a> for more information on
305 Callgrind specific client requests.</p></li>
306 </ul></div>
307 <p>If you are running a multi-threaded application and specify the
308 command line option
309 <code class="option"><a class="link" href="cl-manual.html#opt.separate-threads">--separate-threads=yes</a></code>,
310 every thread will be profiled on its own and will create its own
311 profile dump. Thus, the last two methods will only generate one dump
312 of the currently running thread. With the other methods, you will get
313 multiple dumps (one for each thread) on a dump request.</p>
314 </div>
315 <div class="sect2">
316 <div class="titlepage"><div><div><h3 class="title">
317 <a name="cl-manual.limits"></a>6.2.2. Limiting the range of collected events</h3></div></div></div>
318 <p>By default, whenever events are happening (such as an
319 instruction execution or cache hit/miss), Callgrind is aggregating
320 them into event counters. However, you may be interested only in
321 what is happening within a given function or starting from a given
322 program phase. To this end, you can disable event aggregation for
323 uninteresting program parts. While attribution of events to
324 functions as well as producing separate output per program phase
325 can be done by other means (see previous section), there are two
326 benefits by disabling aggregation. First, this is very
327 fine-granular (e.g. just for a loop within a function). Second,
328 disabling event aggregation for complete program phases allows to
329 switch off time-consuming cache simulation and allows Callgrind to
330 progress at much higher speed with an slowdown of around factor 2
331 (identical to <code class="computeroutput">valgrind
332 --tool=none</code>).
333 </p>
334 <p>There are two aspects which influence whether Callgrind is
335 aggregating events at some point in time of program execution.
336 First, there is the <span class="emphasis"><em>collection state</em></span>. If this
337 is off, no aggregation will be done. By changing the collection
338 state, you can control event aggregation at a very fine
339 granularity. However, there is not much difference in regard to
340 execution speed of Callgrind. By default, collection is switched
341 on, but can be disabled by different means (see below). Second,
342 there is the <span class="emphasis"><em>instrumentation mode</em></span> in which
343 Callgrind is running. This mode either can be on or off. If
344 instrumentation is off, no observation of actions in the program
345 will be done and thus, no actions will be forwarded to the
346 simulator which could trigger events. In the end, no events will
347 be aggregated. The huge benefit is the much higher speed with
348 instrumentation switched off. However, this only should be used
349 with care and in a coarse fashion: every mode change resets the
350 simulator state (ie. whether a memory block is cached or not) and
351 flushes Valgrinds internal cache of instrumented code blocks,
352 resulting in latency penalty at switching time. Also, cache
353 simulator results directly after switching on instrumentation will
354 be skewed due to identified cache misses which would not happen in
355 reality (if you care about this warm-up effect, you should make
356 sure to temporarly have collection state switched off directly
357 after turning instrumentation mode on). However, switching
358 instrumentation state is very useful to skip larger program phases
359 such as an initialization phase. By default, instrumentation is
360 switched on, but as with the collection state, can be changed by
361 various means.
362 </p>
363 <p>Callgrind can start with instrumentation mode switched off by
364 specifying option
365 <code class="option"><a class="link" href="cl-manual.html#opt.instr-atstart">--instr-atstart=no</a></code>.
366 Afterwards, instrumentation can be controlled in two ways: first,
367 interactively with: </p>
368 <pre class="screen">callgrind_control -i on</pre>
369 <p> (and
370 switching off again by specifying "off" instead of "on"). Second,
371 instrumentation state can be programmatically changed with the
372 macros <code class="computeroutput"><a class="link" href="cl-manual.html#cr.start-instr">CALLGRIND_START_INSTRUMENTATION</a>;</code>
373 and <code class="computeroutput"><a class="link" href="cl-manual.html#cr.stop-instr">CALLGRIND_STOP_INSTRUMENTATION</a>;</code>.
374 </p>
375 <p>Similarly, the collection state at program start can be
376 switched off by
377 <code class="option"><a class="link" href="cl-manual.html#opt.instr-atstart">--instr-atstart=no</a></code>.
378 During execution, it can be controlled programmatically with the
379 macro <code class="computeroutput">CALLGRIND_TOGGLE_COLLECT;</code>.
380 Further, you can limit event collection to a specific function by
381 using <code class="option"><a class="link" href="cl-manual.html#opt.toggle-collect">--toggle-collect=function</a></code>.
382 This will toggle the collection state on entering and leaving the
383 specified function. When this option is in effect, the default
384 collection state at program start is "off". Only events happening
385 while running inside of the given function will be
386 collected. Recursive calls of the given function do not trigger
387 any action. This option can be given multiple times to specify
388 different functions of interest.</p>
389 </div>
390 <div class="sect2">
391 <div class="titlepage"><div><div><h3 class="title">
392 <a name="cl-manual.busevents"></a>6.2.3. Counting global bus events</h3></div></div></div>
393 <p>For access to shared data among threads in a multithreaded
394 code, synchronization is required to avoid raced conditions.
395 Synchronization primitives are usually implemented via atomic instructions.
396 However, excessive use of such instructions can lead to performance
397 issues.</p>
398 <p>To enable analysis of this problem, Callgrind optionally can count
399 the number of atomic instructions executed. More precisely, for x86/x86_64,
400 these are instructions using a lock prefix. For architectures supporting
401 LL/SC, these are the number of SC instructions executed. For both, the term
402 "global bus events" is used.</p>
403 <p>The short name of the event type used for global bus events is "Ge".
404 To count global bus events, use
405 <code class="option"><a class="link" href="cl-manual.html#clopt.collect-bus">--collect-bus=yes</a></code>.
406 </p>
407 </div>
408 <div class="sect2">
409 <div class="titlepage"><div><div><h3 class="title">
410 <a name="cl-manual.cycles"></a>6.2.4. Avoiding cycles</h3></div></div></div>
411 <p>Informally speaking, a cycle is a group of functions which
412 call each other in a recursive way.</p>
413 <p>Formally speaking, a cycle is a nonempty set S of functions,
414 such that for every pair of functions F and G in S, it is possible
415 to call from F to G (possibly via intermediate functions) and also
416 from G to F. Furthermore, S must be maximal -- that is, be the
417 largest set of functions satisfying this property. For example, if
418 a third function H is called from inside S and calls back into S,
419 then H is also part of the cycle and should be included in S.</p>
420 <p>Recursion is quite usual in programs, and therefore, cycles
421 sometimes appear in the call graph output of Callgrind. However,
422 the title of this chapter should raise two questions: What is bad
423 about cycles which makes you want to avoid them? And: How can
424 cycles be avoided without changing program code?</p>
425 <p>Cycles are not bad in itself, but tend to make performance
426 analysis of your code harder. This is because inclusive costs
427 for calls inside of a cycle are meaningless. The definition of
428 inclusive cost, i.e. self cost of a function plus inclusive cost
429 of its callees, needs a topological order among functions. For
430 cycles, this does not hold true: callees of a function in a cycle include
431 the function itself. Therefore, KCachegrind does cycle detection
432 and skips visualization of any inclusive cost for calls inside
433 of cycles. Further, all functions in a cycle are collapsed into artificial
434 functions called like <code class="computeroutput">Cycle 1</code>.</p>
435 <p>Now, when a program exposes really big cycles (as is
436 true for some GUI code, or in general code using event or callback based
437 programming style), you lose the nice property to let you pinpoint
438 the bottlenecks by following call chains from
439 <code class="function">main</code>, guided via
440 inclusive cost. In addition, KCachegrind loses its ability to show
441 interesting parts of the call graph, as it uses inclusive costs to
442 cut off uninteresting areas.</p>
443 <p>Despite the meaningless of inclusive costs in cycles, the big
444 drawback for visualization motivates the possibility to temporarily
445 switch off cycle detection in KCachegrind, which can lead to
446 misguiding visualization. However, often cycles appear because of
447 unlucky superposition of independent call chains in a way that
448 the profile result will see a cycle. Neglecting uninteresting
449 calls with very small measured inclusive cost would break these
450 cycles. In such cases, incorrect handling of cycles by not detecting
451 them still gives meaningful profiling visualization.</p>
452 <p>It has to be noted that currently, <span class="command"><strong>callgrind_annotate</strong></span>
453 does not do any cycle detection at all. For program executions with function
454 recursion, it e.g. can print nonsense inclusive costs way above 100%.</p>
455 <p>After describing why cycles are bad for profiling, it is worth
456 talking about cycle avoidance. The key insight here is that symbols in
457 the profile data do not have to exactly match the symbols found in the
458 program. Instead, the symbol name could encode additional information
459 from the current execution context such as recursion level of the
460 current function, or even some part of the call chain leading to the
461 function. While encoding of additional information into symbols is
462 quite capable of avoiding cycles, it has to be used carefully to not cause
463 symbol explosion. The latter imposes large memory requirement for Callgrind
464 with possible out-of-memory conditions, and big profile data files.</p>
465 <p>A further possibility to avoid cycles in Callgrind's profile data
466 output is to simply leave out given functions in the call graph. Of course, this
467 also skips any call information from and to an ignored function, and thus can
468 break a cycle. Candidates for this typically are dispatcher functions in event
469 driven code. The option to ignore calls to a function is
470 <code class="option"><a class="link" href="cl-manual.html#opt.fn-skip">--fn-skip=function</a></code>.
471 Aside from possibly breaking cycles, this is used in Callgrind to skip
472 trampoline functions in the PLT sections
473 for calls to functions in shared libraries. You can see the difference
474 if you profile with
475 <code class="option"><a class="link" href="cl-manual.html#opt.skip-plt">--skip-plt=no</a></code>.
476 If a call is ignored, its cost events will be propagated to the
477 enclosing function.</p>
478 <p>If you have a recursive function, you can distinguish the first
479 10 recursion levels by specifying
480 <code class="option"><a class="link" href="cl-manual.html#opt.separate-recs-num">--separate-recs10=function</a></code>.
481 Or for all functions with
482 <code class="option"><a class="link" href="cl-manual.html#opt.separate-recs">--separate-recs=10</a></code>,
483 but this will
484 give you much bigger profile data files. In the profile data, you will see
485 the recursion levels of "func" as the different functions with names
486 "func", "func'2", "func'3" and so on.</p>
487 <p>If you have call chains "A &gt; B &gt; C" and "A &gt; C &gt; B"
488 in your program, you usually get a "false" cycle "B &lt;&gt; C". Use
489 <code class="option"><a class="link" href="cl-manual.html#opt.separate-callers-num">--separate-callers2=B</a></code>
490 <code class="option"><a class="link" href="cl-manual.html#opt.separate-callers-num">--separate-callers2=C</a></code>,
491 and functions "B" and "C" will be treated as different functions
492 depending on the direct caller. Using the apostrophe for appending
493 this "context" to the function name, you get "A &gt; B'A &gt; C'B"
494 and "A &gt; C'A &gt; B'C", and there will be no cycle. Use
495 <code class="option"><a class="link" href="cl-manual.html#opt.separate-callers">--separate-callers=2</a></code> to get a 2-caller
496 dependency for all functions. Note that doing this will increase
497 the size of profile data files.</p>
498 </div>
499 <div class="sect2">
500 <div class="titlepage"><div><div><h3 class="title">
501 <a name="cl-manual.forkingprograms"></a>6.2.5. Forking Programs</h3></div></div></div>
502 <p>If your program forks, the child will inherit all the profiling
503 data that has been gathered for the parent. To start with empty profile
504 counter values in the child, the client request
505 <code class="computeroutput"><a class="link" href="cl-manual.html#cr.zero-stats">CALLGRIND_ZERO_STATS</a>;</code>
506 can be inserted into code to be executed by the child, directly
507 after
508 <code class="computeroutput">fork</code>.</p>
509 <p>However, you will have to make sure that the output file format string
510 (controlled by <code class="option">--callgrind-out-file</code>) does contain
511 <code class="option">%p</code> (which is true by default). Otherwise, the
512 outputs from the parent and child will overwrite each other or will be
513 intermingled, which almost certainly is not what you want.</p>
514 <p>You will be able to control the new child independently from
515 the parent via callgrind_control.</p>
516 </div>
517 </div>
518 <div class="sect1">
519 <div class="titlepage"><div><div><h2 class="title" style="clear: both">
520 <a name="cl-manual.options"></a>6.3. Callgrind Command-line Options</h2></div></div></div>
521 <p>
522 In the following, options are grouped into classes.
523 </p>
524 <p>
525 Some options allow the specification of a function/symbol name, such as
526 <code class="option"><a class="link" href="cl-manual.html#opt.dump-before">--dump-before=function</a></code>, or
527 <code class="option"><a class="link" href="cl-manual.html#opt.fn-skip">--fn-skip=function</a></code>.
528 All these options can be specified multiple times for different functions.
529 In addition, the function specifications actually are patterns by supporting
530 the use of wildcards '*' (zero or more arbitrary characters) and '?'
531 (exactly one arbitrary character), similar to file name globbing in the
532 shell. This feature is important especially for C++, as without wildcard
533 usage, the function would have to be specified in full extent, including
534 parameter signature. </p>
535 <div class="sect2">
536 <div class="titlepage"><div><div><h3 class="title">
537 <a name="cl-manual.options.creation"></a>6.3.1. Dump creation options</h3></div></div></div>
538 <p>
539 These options influence the name and format of the profile data files.
540 </p>
541 <div class="variablelist">
542 <a name="cl.opts.list.creation"></a><dl class="variablelist">
543 <dt>
544 <a name="opt.callgrind-out-file"></a><span class="term">
545 <code class="option">--callgrind-out-file=&lt;file&gt; </code>
546 </span>
547 </dt>
548 <dd><p>Write the profile data to
549 <code class="computeroutput">file</code> rather than to the default
550 output file,
551 <code class="computeroutput">callgrind.out.&lt;pid&gt;</code>. The
552 <code class="option">%p</code> and <code class="option">%q</code> format specifiers
553 can be used to embed the process ID and/or the contents of an
554 environment variable in the name, as is the case for the core
555 option
556 <code class="option"><a class="link" href="manual-core.html#opt.log-file">--log-file</a></code>.
557 When multiple dumps are made, the file name
558 is modified further; see below.</p></dd>
559 <dt>
560 <a name="opt.dump-line"></a><span class="term">
561 <code class="option">--dump-line=&lt;no|yes&gt; [default: yes] </code>
562 </span>
563 </dt>
564 <dd><p>This specifies that event counting should be performed at
565 source line granularity. This allows source annotation for sources
566 which are compiled with debug information
567 (<code class="option">-g</code>).</p></dd>
568 <dt>
569 <a name="opt.dump-instr"></a><span class="term">
570 <code class="option">--dump-instr=&lt;no|yes&gt; [default: no] </code>
571 </span>
572 </dt>
573 <dd><p>This specifies that event counting should be performed at
574 per-instruction granularity.
575 This allows for assembly code
576 annotation. Currently the results can only be
577 displayed by KCachegrind.</p></dd>
578 <dt>
579 <a name="opt.compress-strings"></a><span class="term">
580 <code class="option">--compress-strings=&lt;no|yes&gt; [default: yes] </code>
581 </span>
582 </dt>
583 <dd><p>This option influences the output format of the profile data.
584 It specifies whether strings (file and function names) should be
585 identified by numbers. This shrinks the file,
586 but makes it more difficult
587 for humans to read (which is not recommended in any case).</p></dd>
588 <dt>
589 <a name="opt.compress-pos"></a><span class="term">
590 <code class="option">--compress-pos=&lt;no|yes&gt; [default: yes] </code>
591 </span>
592 </dt>
593 <dd><p>This option influences the output format of the profile data.
594 It specifies whether numerical positions are always specified as absolute
595 values or are allowed to be relative to previous numbers.
596 This shrinks the file size.</p></dd>
597 <dt>
598 <a name="opt.combine-dumps"></a><span class="term">
599 <code class="option">--combine-dumps=&lt;no|yes&gt; [default: no] </code>
600 </span>
601 </dt>
602 <dd><p>When enabled, when multiple profile data parts are to be
603 generated these parts are appended to the same output file.
604 Not recommended.</p></dd>
605 </dl>
606 </div>
607 </div>
608 <div class="sect2">
609 <div class="titlepage"><div><div><h3 class="title">
610 <a name="cl-manual.options.activity"></a>6.3.2. Activity options</h3></div></div></div>
611 <p>
612 These options specify when actions relating to event counts are to
613 be executed. For interactive control use callgrind_control.
614 </p>
615 <div class="variablelist">
616 <a name="cl.opts.list.activity"></a><dl class="variablelist">
617 <dt>
618 <a name="opt.dump-every-bb"></a><span class="term">
619 <code class="option">--dump-every-bb=&lt;count&gt; [default: 0, never] </code>
620 </span>
621 </dt>
622 <dd><p>Dump profile data every <code class="option">count</code> basic blocks.
623 Whether a dump is needed is only checked when Valgrind's internal
624 scheduler is run. Therefore, the minimum setting useful is about 100000.
625 The count is a 64-bit value to make long dump periods possible.
626 </p></dd>
627 <dt>
628 <a name="opt.dump-before"></a><span class="term">
629 <code class="option">--dump-before=&lt;function&gt; </code>
630 </span>
631 </dt>
632 <dd><p>Dump when entering <code class="option">function</code>.</p></dd>
633 <dt>
634 <a name="opt.zero-before"></a><span class="term">
635 <code class="option">--zero-before=&lt;function&gt; </code>
636 </span>
637 </dt>
638 <dd><p>Zero all costs when entering <code class="option">function</code>.</p></dd>
639 <dt>
640 <a name="opt.dump-after"></a><span class="term">
641 <code class="option">--dump-after=&lt;function&gt; </code>
642 </span>
643 </dt>
644 <dd><p>Dump when leaving <code class="option">function</code>.</p></dd>
645 </dl>
646 </div>
647 </div>
648 <div class="sect2">
649 <div class="titlepage"><div><div><h3 class="title">
650 <a name="cl-manual.options.collection"></a>6.3.3. Data collection options</h3></div></div></div>
651 <p>
652 These options specify when events are to be aggregated into event counts.
653 Also see <a class="xref" href="cl-manual.html#cl-manual.limits" title="6.2.2. Limiting the range of collected events">Limiting range of event collection</a>.</p>
654 <div class="variablelist">
655 <a name="cl.opts.list.collection"></a><dl class="variablelist">
656 <dt>
657 <a name="opt.instr-atstart"></a><span class="term">
658 <code class="option">--instr-atstart=&lt;yes|no&gt; [default: yes] </code>
659 </span>
660 </dt>
661 <dd>
662 <p>Specify if you want Callgrind to start simulation and
663 profiling from the beginning of the program.
664 When set to <code class="computeroutput">no</code>,
665 Callgrind will not be able
666 to collect any information, including calls, but it will have at
667 most a slowdown of around 4, which is the minimum Valgrind
668 overhead. Instrumentation can be interactively enabled via
669 <code class="computeroutput">callgrind_control -i on</code>.</p>
670 <p>Note that the resulting call graph will most probably not
671 contain <code class="function">main</code>, but will contain all the
672 functions executed after instrumentation was enabled.
673 Instrumentation can also be programmatically enabled/disabled. See the
674 Callgrind include file
675 <code class="computeroutput">callgrind.h</code> for the macro
676 you have to use in your source code.</p>
677 <p>For cache
678 simulation, results will be less accurate when switching on
679 instrumentation later in the program run, as the simulator starts
680 with an empty cache at that moment. Switch on event collection
681 later to cope with this error.</p>
682 </dd>
683 <dt>
684 <a name="opt.collect-atstart"></a><span class="term">
685 <code class="option">--collect-atstart=&lt;yes|no&gt; [default: yes] </code>
686 </span>
687 </dt>
688 <dd>
689 <p>Specify whether event collection is enabled at beginning
690 of the profile run.</p>
691 <p>To only look at parts of your program, you have two
692 possibilities:</p>
693 <div class="orderedlist"><ol class="orderedlist" type="1">
694 <li class="listitem"><p>Zero event counters before entering the program part you
695 want to profile, and dump the event counters to a file after
696 leaving that program part.</p></li>
697 <li class="listitem"><p>Switch on/off collection state as needed to only see
698 event counters happening while inside of the program part you
699 want to profile.</p></li>
700 </ol></div>
701 <p>The second option can be used if the program part you want to
702 profile is called many times. Option 1, i.e. creating a lot of
703 dumps is not practical here.</p>
704 <p>Collection state can be
705 toggled at entry and exit of a given function with the
706 option <code class="option"><a class="link" href="cl-manual.html#opt.toggle-collect">--toggle-collect</a></code>. If you
707 use this option, collection
708 state should be disabled at the beginning. Note that the
709 specification of <code class="option">--toggle-collect</code>
710 implicitly sets
711 <code class="option">--collect-state=no</code>.</p>
712 <p>Collection state can be toggled also by inserting the client request
713 <code class="computeroutput">
714
715 CALLGRIND_TOGGLE_COLLECT
716 ;</code>
717 at the needed code positions.</p>
718 </dd>
719 <dt>
720 <a name="opt.toggle-collect"></a><span class="term">
721 <code class="option">--toggle-collect=&lt;function&gt; </code>
722 </span>
723 </dt>
724 <dd><p>Toggle collection on entry/exit of <code class="option">function</code>.</p></dd>
725 <dt>
726 <a name="opt.collect-jumps"></a><span class="term">
727 <code class="option">--collect-jumps=&lt;no|yes&gt; [default: no] </code>
728 </span>
729 </dt>
730 <dd><p>This specifies whether information for (conditional) jumps
731 should be collected. As above, callgrind_annotate currently is not
732 able to show you the data. You have to use KCachegrind to get jump
733 arrows in the annotated code.</p></dd>
734 <dt>
735 <a name="opt.collect-systime"></a><span class="term">
736 <code class="option">--collect-systime=&lt;no|yes|msec|usec|nsec&gt; [default: no] </code>
737 </span>
738 </dt>
739 <dd>
740 <p>This specifies whether information for system call times
741 should be collected.</p>
742 <p>The value <code class="computeroutput">no</code> indicates to record
743 no system call information.</p>
744 <p>The other values indicate to record the number of system calls
745 done (sysCount event) and the elapsed time (sysTime event) spent
746 in system calls.
747 The <code class="computeroutput">--collect-systime</code> value gives
748 the unit used for sysTime : milli seconds, micro seconds or nano
749 seconds. With the value <code class="computeroutput">nsec</code>,
750 callgrind also records the cpu time spent during system calls
751 (sysCpuTime).</p>
752 <p>The value <code class="computeroutput">yes</code> is a synonym
753 of <code class="computeroutput">msec</code>.
754 The value <code class="computeroutput">nsec</code> is not supported
755 on Darwin.</p>
756 </dd>
757 <dt>
758 <a name="clopt.collect-bus"></a><span class="term">
759 <code class="option">--collect-bus=&lt;no|yes&gt; [default: no] </code>
760 </span>
761 </dt>
762 <dd><p>This specifies whether the number of global bus events executed
763 should be collected. The event type "Ge" is used for these events.</p></dd>
764 </dl>
765 </div>
766 </div>
767 <div class="sect2">
768 <div class="titlepage"><div><div><h3 class="title">
769 <a name="cl-manual.options.separation"></a>6.3.4. Cost entity separation options</h3></div></div></div>
770 <p>
771 These options specify how event counts should be attributed to execution
772 contexts.
773 For example, they specify whether the recursion level or the
774 call chain leading to a function should be taken into account,
775 and whether the thread ID should be considered.
776 Also see <a class="xref" href="cl-manual.html#cl-manual.cycles" title="6.2.4. Avoiding cycles">Avoiding cycles</a>.</p>
777 <div class="variablelist">
778 <a name="cmd-options.separation"></a><dl class="variablelist">
779 <dt>
780 <a name="opt.separate-threads"></a><span class="term">
781 <code class="option">--separate-threads=&lt;no|yes&gt; [default: no] </code>
782 </span>
783 </dt>
784 <dd><p>This option specifies whether profile data should be generated
785 separately for every thread. If yes, the file names get "-threadID"
786 appended.</p></dd>
787 <dt>
788 <a name="opt.separate-callers"></a><span class="term">
789 <code class="option">--separate-callers=&lt;callers&gt; [default: 0] </code>
790 </span>
791 </dt>
792 <dd><p>Separate contexts by at most &lt;callers&gt; functions in the
793 call chain. See <a class="xref" href="cl-manual.html#cl-manual.cycles" title="6.2.4. Avoiding cycles">Avoiding cycles</a>.</p></dd>
794 <dt>
795 <a name="opt.separate-callers-num"></a><span class="term">
796 <code class="option">--separate-callers&lt;number&gt;=&lt;function&gt; </code>
797 </span>
798 </dt>
799 <dd><p>Separate <code class="option">number</code> callers for <code class="option">function</code>.
800 See <a class="xref" href="cl-manual.html#cl-manual.cycles" title="6.2.4. Avoiding cycles">Avoiding cycles</a>.</p></dd>
801 <dt>
802 <a name="opt.separate-recs"></a><span class="term">
803 <code class="option">--separate-recs=&lt;level&gt; [default: 2] </code>
804 </span>
805 </dt>
806 <dd><p>Separate function recursions by at most <code class="option">level</code> levels.
807 See <a class="xref" href="cl-manual.html#cl-manual.cycles" title="6.2.4. Avoiding cycles">Avoiding cycles</a>.</p></dd>
808 <dt>
809 <a name="opt.separate-recs-num"></a><span class="term">
810 <code class="option">--separate-recs&lt;number&gt;=&lt;function&gt; </code>
811 </span>
812 </dt>
813 <dd><p>Separate <code class="option">number</code> recursions for <code class="option">function</code>.
814 See <a class="xref" href="cl-manual.html#cl-manual.cycles" title="6.2.4. Avoiding cycles">Avoiding cycles</a>.</p></dd>
815 <dt>
816 <a name="opt.skip-plt"></a><span class="term">
817 <code class="option">--skip-plt=&lt;no|yes&gt; [default: yes] </code>
818 </span>
819 </dt>
820 <dd><p>Ignore calls to/from PLT sections.</p></dd>
821 <dt>
822 <a name="opt.skip-direct-rec"></a><span class="term">
823 <code class="option">--skip-direct-rec=&lt;no|yes&gt; [default: yes] </code>
824 </span>
825 </dt>
826 <dd><p>Ignore direct recursions.</p></dd>
827 <dt>
828 <a name="opt.fn-skip"></a><span class="term">
829 <code class="option">--fn-skip=&lt;function&gt; </code>
830 </span>
831 </dt>
832 <dd>
833 <p>Ignore calls to/from a given function. E.g. if you have a
834 call chain A &gt; B &gt; C, and you specify function B to be
835 ignored, you will only see A &gt; C.</p>
836 <p>This is very convenient to skip functions handling callback
837 behaviour. For example, with the signal/slot mechanism in the
838 Qt graphics library, you only want
839 to see the function emitting a signal to call the slots connected
840 to that signal. First, determine the real call chain to see the
841 functions needed to be skipped, then use this option.</p>
842 </dd>
843 </dl>
844 </div>
845 </div>
846 <div class="sect2">
847 <div class="titlepage"><div><div><h3 class="title">
848 <a name="cl-manual.options.simulation"></a>6.3.5. Simulation options</h3></div></div></div>
849 <div class="variablelist">
850 <a name="cl.opts.list.simulation"></a><dl class="variablelist">
851 <dt>
852 <a name="clopt.cache-sim"></a><span class="term">
853 <code class="option">--cache-sim=&lt;yes|no&gt; [default: no] </code>
854 </span>
855 </dt>
856 <dd><p>Specify if you want to do full cache simulation. By default,
857 only instruction read accesses will be counted ("Ir").
858 With cache simulation, further event counters are enabled:
859 Cache misses on instruction reads ("I1mr"/"ILmr"),
860 data read accesses ("Dr") and related cache misses ("D1mr"/"DLmr"),
861 data write accesses ("Dw") and related cache misses ("D1mw"/"DLmw").
862 For more information, see <a class="xref" href="cg-manual.html" title="5. Cachegrind: a high-precision tracing profiler">Cachegrind: a cache and branch-prediction profiler</a>.
863 </p></dd>
864 <dt>
865 <a name="clopt.branch-sim"></a><span class="term">
866 <code class="option">--branch-sim=&lt;yes|no&gt; [default: no] </code>
867 </span>
868 </dt>
869 <dd><p>Specify if you want to do branch prediction simulation.
870 Further event counters are enabled: Number of executed conditional
871 branches and related predictor misses ("Bc"/"Bcm"), executed indirect
872 jumps and related misses of the jump address predictor ("Bi"/"Bim").
873 </p></dd>
874 </dl>
875 </div>
876 </div>
877 <div class="sect2">
878 <div class="titlepage"><div><div><h3 class="title">
879 <a name="cl-manual.options.cachesimulation"></a>6.3.6. Cache simulation options</h3></div></div></div>
880 <div class="variablelist">
881 <a name="cl.opts.list.cachesimulation"></a><dl class="variablelist">
882 <dt>
883 <a name="opt.simulate-wb"></a><span class="term">
884 <code class="option">--simulate-wb=&lt;yes|no&gt; [default: no] </code>
885 </span>
886 </dt>
887 <dd><p>Specify whether write-back behavior should be simulated, allowing
888 to distinguish LL caches misses with and without write backs.
889 The cache model of Cachegrind/Callgrind does not specify write-through
890 vs. write-back behavior, and this also is not relevant for the number
891 of generated miss counts. However, with explicit write-back simulation
892 it can be decided whether a miss triggers not only the loading of a new
893 cache line, but also if a write back of a dirty cache line had to take
894 place before. The new dirty miss events are ILdmr, DLdmr, and DLdmw,
895 for misses because of instruction read, data read, and data write,
896 respectively. As they produce two memory transactions, they should
897 account for a doubled time estimation in relation to a normal miss.
898 </p></dd>
899 <dt>
900 <a name="opt.simulate-hwpref"></a><span class="term">
901 <code class="option">--simulate-hwpref=&lt;yes|no&gt; [default: no] </code>
902 </span>
903 </dt>
904 <dd><p>Specify whether simulation of a hardware prefetcher should be
905 added which is able to detect stream access in the second level cache
906 by comparing accesses to separate to each page.
907 As the simulation can not decide about any timing issues of prefetching,
908 it is assumed that any hardware prefetch triggered succeeds before a
909 real access is done. Thus, this gives a best-case scenario by covering
910 all possible stream accesses.</p></dd>
911 <dt>
912 <a name="opt.cacheuse"></a><span class="term">
913 <code class="option">--cacheuse=&lt;yes|no&gt; [default: no] </code>
914 </span>
915 </dt>
916 <dd><p>Specify whether cache line use should be collected. For every
917 cache line, from loading to it being evicted, the number of accesses
918 as well as the number of actually used bytes is determined. This
919 behavior is related to the code which triggered loading of the cache
920 line. In contrast to miss counters, which shows the position where
921 the symptoms of bad cache behavior (i.e. latencies) happens, the
922 use counters try to pinpoint at the reason (i.e. the code with the
923 bad access behavior). The new counters are defined in a way such
924 that worse behavior results in higher cost.
925 AcCost1 and AcCost2 are counters showing bad temporal locality
926 for L1 and LL caches, respectively. This is done by summing up
927 reciprocal values of the numbers of accesses of each cache line,
928 multiplied by 1000 (as only integer costs are allowed). E.g. for
929 a given source line with 5 read accesses, a value of 5000 AcCost
930 means that for every access, a new cache line was loaded and directly
931 evicted afterwards without further accesses. Similarly, SpLoss1/2
932 shows bad spatial locality for L1 and LL caches, respectively. It
933 gives the <span class="emphasis"><em>spatial loss</em></span> count of bytes which
934 were loaded into cache but never accessed. It pinpoints at code
935 accessing data in a way such that cache space is wasted. This hints
936 at bad layout of data structures in memory. Assuming a cache line
937 size of 64 bytes and 100 L1 misses for a given source line, the
938 loading of 6400 bytes into L1 was triggered. If SpLoss1 shows a
939 value of 3200 for this line, this means that half of the loaded data was
940 never used, or using a better data layout, only half of the cache
941 space would have been needed.
942 Please note that for cache line use counters, it currently is
943 not possible to provide meaningful inclusive costs. Therefore,
944 inclusive cost of these counters should be ignored.
945 </p></dd>
946 <dt>
947 <a name="cl.opt.I1"></a><span class="term">
948 <code class="option">--I1=&lt;size&gt;,&lt;associativity&gt;,&lt;line size&gt; </code>
949 </span>
950 </dt>
951 <dd><p>Specify the size, associativity and line size of the level 1
952 instruction cache. </p></dd>
953 <dt>
954 <a name="cl.opt.D1"></a><span class="term">
955 <code class="option">--D1=&lt;size&gt;,&lt;associativity&gt;,&lt;line size&gt; </code>
956 </span>
957 </dt>
958 <dd><p>Specify the size, associativity and line size of the level 1
959 data cache.</p></dd>
960 <dt>
961 <a name="cl.opt.LL"></a><span class="term">
962 <code class="option">--LL=&lt;size&gt;,&lt;associativity&gt;,&lt;line size&gt; </code>
963 </span>
964 </dt>
965 <dd><p>Specify the size, associativity and line size of the last-level
966 cache.</p></dd>
967 </dl>
968 </div>
969 </div>
970 </div>
971 <div class="sect1">
972 <div class="titlepage"><div><div><h2 class="title" style="clear: both">
973 <a name="cl-manual.monitor-commands"></a>6.4. Callgrind Monitor Commands</h2></div></div></div>
974 <p>The Callgrind tool provides monitor commands handled by the Valgrind
975 gdbserver (see <a class="xref" href="manual-core-adv.html#manual-core-adv.gdbserver-commandhandling" title="3.2.5. Monitor command handling by the Valgrind gdbserver">Monitor command handling by the Valgrind gdbserver</a>).
976 Valgrind python code provides GDB front end commands giving an easier usage of
977 the callgrind monitor commands (see
978 <a class="xref" href="manual-core-adv.html#manual-core-adv.gdbserver-gdbmonitorfrontend" title="3.2.6. GDB front end commands for Valgrind gdbserver monitor commands">GDB front end commands for Valgrind gdbserver monitor commands</a>). To launch a
979 callgrind monitor command via its GDB front end command, instead of prefixing
980 the command with "monitor", you must use the GDB <code class="varname">callgrind</code>
981 command (or the shorter aliases <code class="varname">cg</code>). Using the callgrind GDB
982 front end command provide a more flexible usage, such as auto-completion of the
983 command by GDB. In GDB, you can use <code class="varname">help callgrind</code> to get
984 help about the callgrind front end monitor commands and you can
985 use <code class="varname">apropos callgrind</code> to get all the commands mentionning the
986 word "callgrind" in their name or on-line help.
987 </p>
988 <div class="itemizedlist"><ul class="itemizedlist" style="list-style-type: disc; ">
989 <li class="listitem"><p><code class="varname">dump [&lt;dump_hint&gt;]</code> requests to dump the
990 profile data. </p></li>
991 <li class="listitem"><p><code class="varname">zero</code> requests to zero the profile data
992 counters. </p></li>
993 <li class="listitem"><p><code class="varname">instrumentation [on|off]</code> requests to set
994 (if parameter on/off is given) or get the current instrumentation state.
995 </p></li>
996 <li class="listitem"><p><code class="varname">status</code> requests to print out some status
997 information.</p></li>
998 </ul></div>
999 </div>
1000 <div class="sect1">
1001 <div class="titlepage"><div><div><h2 class="title" style="clear: both">
1002 <a name="cl-manual.clientrequests"></a>6.5. Callgrind specific client requests</h2></div></div></div>
1003 <p>Callgrind provides the following specific client requests in
1004 <code class="filename">callgrind.h</code>. See that file for the exact details of
1005 their arguments.</p>
1006 <div class="variablelist">
1007 <a name="cl.clientrequests.list"></a><dl class="variablelist">
1008 <dt>
1009 <a name="cr.dump-stats"></a><span class="term">
1010 <code class="computeroutput">CALLGRIND_DUMP_STATS</code>
1011 </span>
1012 </dt>
1013 <dd><p>Force generation of a profile dump at specified position
1014 in code, for the current thread only. Written counters will be reset
1015 to zero.</p></dd>
1016 <dt>
1017 <a name="cr.dump-stats-at"></a><span class="term">
1018 <code class="computeroutput">CALLGRIND_DUMP_STATS_AT(string)</code>
1019 </span>
1020 </dt>
1021 <dd><p>Same as <code class="computeroutput">CALLGRIND_DUMP_STATS</code>,
1022 but allows to specify a string to be able to distinguish profile
1023 dumps.</p></dd>
1024 <dt>
1025 <a name="cr.zero-stats"></a><span class="term">
1026 <code class="computeroutput">CALLGRIND_ZERO_STATS</code>
1027 </span>
1028 </dt>
1029 <dd><p>Reset the profile counters for the current thread to zero.</p></dd>
1030 <dt>
1031 <a name="cr.toggle-collect"></a><span class="term">
1032 <code class="computeroutput">CALLGRIND_TOGGLE_COLLECT</code>
1033 </span>
1034 </dt>
1035 <dd><p>Toggle the collection state. This allows to ignore events
1036 with regard to profile counters. See also options
1037 <code class="option"><a class="link" href="cl-manual.html#opt.collect-atstart">--collect-atstart</a></code>
1038 and
1039 <code class="option"><a class="link" href="cl-manual.html#opt.toggle-collect">--toggle-collect</a></code>.</p></dd>
1040 <dt>
1041 <a name="cr.start-instr"></a><span class="term">
1042 <code class="computeroutput">CALLGRIND_START_INSTRUMENTATION</code>
1043 </span>
1044 </dt>
1045 <dd><p>Start full Callgrind instrumentation if not already enabled.
1046 When cache simulation is done, this will flush the simulated cache
1047 and lead to an artificial cache warmup phase afterwards with
1048 cache misses which would not have happened in reality. See also
1049 option
1050 <code class="option"><a class="link" href="cl-manual.html#opt.instr-atstart">--instr-atstart</a></code>.
1051 </p></dd>
1052 <dt>
1053 <a name="cr.stop-instr"></a><span class="term">
1054 <code class="computeroutput">CALLGRIND_STOP_INSTRUMENTATION</code>
1055 </span>
1056 </dt>
1057 <dd><p>Stop full Callgrind instrumentation if not already disabled.
1058 This flushes Valgrinds translation cache, and does no additional
1059 instrumentation afterwards: it effectivly will run at the same
1060 speed as Nulgrind, i.e. at minimal slowdown. Use this to
1061 speed up the Callgrind run for uninteresting code parts. Use
1062 <code class="computeroutput"><a class="link" href="cl-manual.html#cr.start-instr">CALLGRIND_START_INSTRUMENTATION</a></code>
1063 to enable instrumentation again. See also option
1064 <code class="option"><a class="link" href="cl-manual.html#opt.instr-atstart">--instr-atstart</a></code>.
1065 </p></dd>
1066 </dl>
1067 </div>
1068 </div>
1069 <div class="sect1">
1070 <div class="titlepage"><div><div><h2 class="title" style="clear: both">
1071 <a name="cl-manual.callgrind_annotate-options"></a>6.6. callgrind_annotate Command-line Options</h2></div></div></div>
1072 <div class="variablelist">
1073 <a name="callgrind_annotate.opts.list"></a><dl class="variablelist">
1074 <dt><span class="term"><code class="option">-h --help</code></span></dt>
1075 <dd><p>Show summary of options.</p></dd>
1076 <dt><span class="term"><code class="option">--version</code></span></dt>
1077 <dd><p>Show version of callgrind_annotate.</p></dd>
1078 <dt><span class="term">
1079 <code class="option">--show=A,B,C [default: all]</code>
1080 </span></dt>
1081 <dd><p>Only show figures for events A,B,C.</p></dd>
1082 <dt><span class="term">
1083 <code class="option">--threshold=&lt;0--100&gt; [default: 99%] </code>
1084 </span></dt>
1085 <dd>
1086 <p>Percentage of counts (of primary sort event) we are
1087 interested in.</p>
1088 <p>callgrind_annotate stops printing functions when the sum
1089 of the cost percentage of the printed functions is bigger or equal
1090 to the given threshold percentage.</p>
1091 </dd>
1092 <dt><span class="term">
1093 <code class="option">--sort=A,B,C</code>
1094 </span></dt>
1095 <dd>
1096 <p>Sort columns by events A,B,C [event column order].</p>
1097 <p>Optionally, each event is followed by a : and a threshold,
1098 to specify different thresholds depending on the event.</p>
1099 <p>callgrind_annotate stops printing functions when the sum
1100 of the cost percentage of the printed functions for all the events
1101 is bigger or equal to the given event threshold percentages.</p>
1102 <p>When one or more thresholds are given via this option,
1103 the value of <code class="option">--threshold</code> is ignored.</p>
1104 </dd>
1105 <dt><span class="term">
1106 <code class="option">--show-percs=&lt;no|yes&gt; [default: no] </code>
1107 </span></dt>
1108 <dd><p>When enabled, a percentage is printed next to all event counts.
1109 This helps gauge the relative importance of each function and line.
1110 </p></dd>
1111 <dt><span class="term">
1112 <code class="option">--auto=&lt;yes|no&gt; [default: yes] </code>
1113 </span></dt>
1114 <dd><p>Annotate all source files containing functions that helped
1115 reach the event count threshold.</p></dd>
1116 <dt><span class="term">
1117 <code class="option">--context=N [default: 8] </code>
1118 </span></dt>
1119 <dd><p>Print N lines of context before and after annotated
1120 lines.</p></dd>
1121 <dt><span class="term">
1122 <code class="option">--inclusive=&lt;yes|no&gt; [default: no] </code>
1123 </span></dt>
1124 <dd><p>Add subroutine costs to functions calls.</p></dd>
1125 <dt><span class="term">
1126 <code class="option">--tree=&lt;none|caller|calling|both&gt; [default: none] </code>
1127 </span></dt>
1128 <dd><p>Print for each function their callers, the called functions
1129 or both.</p></dd>
1130 <dt><span class="term">
1131 <code class="option">-I, --include=&lt;dir&gt; </code>
1132 </span></dt>
1133 <dd><p>Add <code class="option">dir</code> to the list of directories to search
1134 for source files.</p></dd>
1135 </dl>
1136 </div>
1137 </div>
1138 <div class="sect1">
1139 <div class="titlepage"><div><div><h2 class="title" style="clear: both">
1140 <a name="cl-manual.callgrind_control-options"></a>6.7. callgrind_control Command-line Options</h2></div></div></div>
1141 <p>By default, callgrind_control acts on all programs run by the
1142 current user under Callgrind. It is possible to limit the actions to
1143 specified Callgrind runs by providing a list of pids or program names as
1144 argument. The default action is to give some brief information about the
1145 applications being run under Callgrind.</p>
1146 <div class="variablelist">
1147 <a name="callgrind_control.opts.list"></a><dl class="variablelist">
1148 <dt><span class="term"><code class="option">-h --help</code></span></dt>
1149 <dd><p>Show a short description, usage, and summary of options.</p></dd>
1150 <dt><span class="term"><code class="option">--version</code></span></dt>
1151 <dd><p>Show version of callgrind_control.</p></dd>
1152 <dt><span class="term"><code class="option">-l --long</code></span></dt>
1153 <dd><p>Show also the working directory, in addition to the brief
1154 information given by default.
1155 </p></dd>
1156 <dt><span class="term"><code class="option">-s --stat</code></span></dt>
1157 <dd><p>Show statistics information about active Callgrind runs.</p></dd>
1158 <dt><span class="term"><code class="option">-b --back</code></span></dt>
1159 <dd><p>Show stack/back traces of each thread in active Callgrind runs. For
1160 each active function in the stack trace, also the number of invocations
1161 since program start (or last dump) is shown. This option can be
1162 combined with -e to show inclusive cost of active functions.</p></dd>
1163 <dt><span class="term"><code class="option">-e [A,B,...] </code> (default: all)</span></dt>
1164 <dd><p>Show the current per-thread, exclusive cost values of event
1165 counters. If no explicit event names are given, figures for all event
1166 types which are collected in the given Callgrind run are
1167 shown. Otherwise, only figures for event types A, B, ... are shown. If
1168 this option is combined with -b, inclusive cost for the functions of
1169 each active stack frame is provided, too.
1170 </p></dd>
1171 <dt><span class="term"><code class="option">--dump[=&lt;desc&gt;] </code> (default: no description)</span></dt>
1172 <dd><p>Request the dumping of profile information. Optionally, a
1173 description can be specified which is written into the dump as part of
1174 the information giving the reason which triggered the dump action. This
1175 can be used to distinguish multiple dumps.</p></dd>
1176 <dt><span class="term"><code class="option">-z --zero</code></span></dt>
1177 <dd><p>Zero all event counters.</p></dd>
1178 <dt><span class="term"><code class="option">-k --kill</code></span></dt>
1179 <dd><p>Force a Callgrind run to be terminated.</p></dd>
1180 <dt><span class="term"><code class="option">--instr=&lt;on|off&gt;</code></span></dt>
1181 <dd><p>Switch instrumentation mode on or off. If a Callgrind run has
1182 instrumentation disabled, no simulation is done and no events are
1183 counted. This is useful to skip uninteresting program parts, as there
1184 is much less slowdown (same as with the Valgrind tool "none"). See also
1185 the Callgrind option <code class="option">--instr-atstart</code>.</p></dd>
1186 <dt><span class="term"><code class="option">--vgdb-prefix=&lt;prefix&gt;</code></span></dt>
1187 <dd><p>Specify the vgdb prefix to use by callgrind_control.
1188 callgrind_control internally uses vgdb to find and control the active
1189 Callgrind runs. If the <code class="option">--vgdb-prefix</code> option was used
1190 for launching valgrind, then the same option must be given to
1191 callgrind_control.</p></dd>
1192 </dl>
1193 </div>
1194 </div>
1195 </div>
1196 <div>
1197 <br><table class="nav" width="100%" cellspacing="3" cellpadding="2" border="0" summary="Navigation footer">
1198 <tr>
1199 <td rowspan="2" width="40%" align="left">
1200 <a accesskey="p" href="cg-manual.html">&lt;&lt; 5. Cachegrind: a high-precision tracing profiler</a> </td>
1201 <td width="20%" align="center"><a accesskey="u" href="manual.html">Up</a></td>
1202 <td rowspan="2" width="40%" align="right"> <a accesskey="n" href="hg-manual.html">7. Helgrind: a thread error detector &gt;&gt;</a>
1203 </td>
1204 </tr>
1205 <tr><td width="20%" align="center"><a accesskey="h" href="index.html">Home</a></td></tr>
1206 </table>
1207 </div>
1208 </body>
1209 </html>