Debian Codegraph @

utils/ir-ctl/ir-ctl.1.in

raw
1 .TH "IR\-CTL" "1" "Tue Jul 5 2016" "v4l-utils @MAN_PACKAGE_VERSION@" "User Commands"
2 .SH NAME
3 ir\-ctl \- a swiss\-knife tool to handle raw IR and to set lirc options
4 .SH SYNOPSIS
5 .B ir\-ctl
6 [\fIOPTION\fR]...
7 .br
8 .B ir\-ctl
9 [\fIOPTION\fR]... \fI\-\-features\fR
10 .br
11 .B ir\-ctl
12 [\fIOPTION\fR]... \fI\-\-send\fR [\fIfile to send\fR]
13 .br
14 .B ir\-ctl
15 [\fIOPTION\fR]... \fI\-\-scancode\fR [\fIprotocol and scancode to send\fR]
16 .br
17 .B ir\-ctl
18 [\fIOPTION\fR]... \fI\-\-keycode\fR [\fIkeycode to send\fR]
19 .br
20 .B ir\-ctl
21 [\fIOPTION\fR]... \fI\-\-receive\fR
22 .SH DESCRIPTION
23 ir\-ctl is a tool that allows one to list the features of a lirc device,
24 set its options, receive raw IR, and send IR.
25 .PP
26 IR can be sent as the keycode of a keymap, or using a scancode, or using
27 raw IR.
28 .PP
29 Note: You need to have read or write permissions on the /dev/lirc device
30 for options to work.
31 .SH OPTIONS
32 .TP
33 \fB\-d\fR, \fB\-\-device\fR=\fIDEV\fR
34 lirc device to control, /dev/lirc0 by default
35 .TP
36 \fB\-f\fR, \fB\-\-features\fR
37 List the features of the lirc device.
38 .TP
39 \fB\-r\fR, \fB\-\-receive\fR
40 Receive IR and print to standard output.
41 .TP
42 \fB\-s\fR, \fB\-\-send\fR=\fIFILE\fR
43 Send IR in text file. It must be in the format described below. If this
44 option is specified multiple times, send all files in\-order with a 125ms gap
45 between them. The gap length can be modified with \fB\-\-gap\fR.
46 .TP
47 \fB-S\fR, \fB\-\-scancode\fR=\fIPROTOCOL:SCANCODE\fR
48 Send the IR scancode in the protocol specified. The protocol must one of the
49 protocols listed below, followed by a colon and the scancode number. If this
50 option is specified multiple times, send all scancodes in\-order with a 125ms
51 gap between them. The gap length can be modified with \fB\-\-gap\fR.
52 .TP
53 \fB-K\fR, \fB\-\-keycode\fR=\fIKEYCODE\fR
54 Send the \fBKEYCODE\fR from the keymap which must be specified with
55 \fB--keymap\fR. If this option is specified multiple times, send all keycodes
56 in\-order with a 125ms gap between them. The gap length can be modified
57 with \fB\-\-gap\fR.
58 .TP
59 \fB-k\fR, \fB\-\-keymap\fR=\fIKEYMAP\fR
60 The rc keymap file in toml format. The format is described in the rc_keymap(5)
61 man page. This file is used to select the \fBKEYCODE\fR from.
62 .TP
63 \fB\-1\fR, \fB\-\-oneshot\fR
64 When receiving, stop receiving after the first message, i.e. after a space or
65 timeout of more than 19ms is received.
66 .TP
67 \fB\-\-mode2\fR
68 When receiving, output IR in mode2 format. One line per space or pulse.
69 .TP
70 \fB\-w\fR, \fB\-\-wideband\fR
71 Use the wideband receiver if available on the hardware. This is also
72 known as learning mode. The measurements should be more precise and any
73 carrier frequency should be accepted.
74 .TP
75 \fB\-n\fR, \fB\-\-narrowband\fR
76 Switches back to the normal, narrowband receiver if the wideband receiver
77 was enabled.
78 .TP
79 \fB\-R\fR, \fB\-\-carrier-range\fR=\fIRANGE\fR
80 Set the accepted carrier range for the narrowband receiver. It should be
81 specified in the form \fI30000-50000\fR.
82 .TP
83 \fB\-m\fR, \fB\-\-measure\-carrier\fR
84 If the hardware supports it, report what the carrier frequency is on
85 receiving. You will get the keyword \fIcarrier\fR followed by the frequency.
86 This might use the wideband receiver although this is hardware specific.
87 .TP
88 \fB\-M\fR, \fB\-\-no\-measure\-carrier\fR
89 Disable reporting of the carrier frequency. This should make it possible
90 to use the narrowband receiver. This is the default.
91 .TP
92 \fB\-t\fR, \fB\-\-timeout\fR=\fITIMEOUT\fR
93 Set the length of a space at which the receiver goes idle, specified in
94 microseconds.
95 .TP
96 \fB\-c\fR, \fB\-\-carrier\fR=\fICARRIER\fR
97 Sets the send carrier frequency.
98 .TP
99 \fB\-D\fR, \fB\-\-duty\-cycle\fR=\fIDUTY\fR
100 Set the duty cycle for sending in percent if the hardware support it.
101 .TP
102 \fB\-e\fR, \fB\-\-emitters\fR=\fIEMITTERS\fR
103 Comma separated list of emitters to use for sending. The first emitter is
104 number 1. Some devices only support enabling one emitter (the winbond-cir
105 driver).
106 .TP
107 \fB\-g\fR, \fB\-\-gap\fR=\fIGAP\fR
108 Set the gap between scancodes or the gap between files when multiple files
109 are specified on the command line. The default is 125000 microseconds.
110 .TP
111 \fB\-?\fR, \fB\-\-help\fR
112 Prints the help message
113 .TP
114 \fB\-\-usage\fR
115 Give a short usage message
116 .TP
117 \fB\-v\fR, \fB\-\-verbose\fR
118 Verbose output; this prints the IR before sending.
119 .TP
120 \fB\-V\fR, \fB\-\-version\fR
121 print the v4l2\-utils version
122 .PP
123 .SS Format of file
124 When sending or receiving raw IR, two formats can be used. The first is
125 a list of integers representing pulse and space values. A pulse value can be
126 prefixed with + and a space with -, but this is optional. The rc-5 scancode
127 0x1e01 is encoded so:
128 .PP
129 +889 -889 +1778 -1778 +889 -889 +889 -889 +889 -889 +1778 -889 +889 -889 +889 -889 +889 -889 +889 -889 +889 -1778 +889
130 .PP
131 The other format mimics the mode2 tool. This produces one line per space
132 or pulse. For receiving it can selected by specifying \fB\-\-mode2\fR. Here is
133 the same message as above, now encoded in mode2:
134 .PP
135 carrier 36000
136 .br
137 pulse 940
138 .br
139 space 860
140 .br
141 pulse 1790
142 .br
143 space 1750
144 .br
145 pulse 880
146 .br
147 space 880
148 .br
149 pulse 900
150 .br
151 space 890
152 .br
153 pulse 870
154 .br
155 space 900
156 .br
157 pulse 1750
158 .br
159 space 900
160 .br
161 pulse 890
162 .br
163 space 910
164 .br
165 pulse 840
166 .br
167 space 920
168 .br
169 pulse 870
170 .br
171 space 920
172 .br
173 pulse 840
174 .br
175 space 920
176 .br
177 pulse 870
178 .br
179 space 1810
180 .br
181 pulse 840
182 .PP
183 Note that in this format, the carrier can also be specified. This can only
184 by done with a separate \fB\-\-carrier=38000\fR command line option with
185 the first format.
186 .PP
187 Rather than specifying just the raw IR, in this format you can also specify
188 the scancode and protocol you want to send. This will also automatically set
189 the correct carrier. The above can be written as:
190 .PP
191 scancode rc5:0x1e01
192 .PP
193 If multiple scancodes are specified in a file, a gap is inserted between
194 scancodes if there is no space between them (see \fB\-\-gap\fR). One file
195 can only have one carrier frequency, so this might cause problems
196 if different protocols are specified in one file if they use different
197 carrier frequencies.
198 .PP
199 Note that there are device-specific limits of how much IR can be sent
200 at a time. This can be both the length of the IR and the number of
201 different lengths of space and pulse.
202 .PP
203 .SS Supported Protocols
204 A scancode with protocol can be specified on the command line or in the
205 pulse and space file. The following protocols are supported:
206 \fBrc5\fR, \fBrc5x_20\fR, \fBrc5_sz\fR, \fBjvc\fR, \fBsony12\fR,
207 \fBsony\fB15\fR, \fBsony20\fR, \fBnec\fR, \fBnecx\fR, \fBnec32\fR,
208 \fBsanyo\fR, \fBrc6_0\fR, \fBrc6_6a_20\fR, \fBrc6_6a_24\fR, \fBrc6_6a_32\fR,
209 \fBrc6_mce\fR, \fBsharp\fR, \fBimon\fR, \fBrc_mm_12\fR, \fBrc_mm_24\fR,
210 \fBrc_mm_32\fR.
211 If the scancode starts with 0x it will be interpreted as a
212 hexadecimal number, and if it starts with 0 it will be interpreted as an
213 octal number.
214 .PP
215 .SS Wideband and narrowband receiver
216 Most IR receivers have a narrowband and wideband receiver. The narrowband
217 receiver can receive over longer distances (usually around 10 metres without
218 interference) and is limited to certain carrier frequencies.
219 .PP
220 The wideband receiver is for higher precision measurements and when the
221 carrier frequency is unknown; however it only works over very short
222 distances (about 5 centimetres). This is also known as \fBlearning mode\fR.
223 .PP
224 For most drivers, enabling \fBcarrier reports\fR using \fB\-m\fR also enables
225 the wideband receiver.
226 .SS Global state
227 All the options which can be set for lirc devices are maintained until
228 the device is powered down or a new option is set.
229 .SH EXIT STATUS
230 On success, it returns 0. Otherwise, it will return the error code.
231 .SH EXAMPLES
232 To list all capabilities of /dev/lirc2:
233 .br
234 \fBir\-ctl \-f \-d /dev/lirc2\fR
235 .PP
236 To show the IR of the first button press on a remote in learning mode:
237 .br
238 \fBir\-ctl \-r \-m \-w\fR
239 .PP
240 To restore the normal (longer distance) receiver:
241 .br
242 \fBir\-ctl \-n \-M\fR
243 .PP
244 To send the pulse and space file \fBplay\fR on emitter 3:
245 .br
246 \fBir\-ctl \-e 3 \-\-send=play\fR
247 .PP
248 To send the rc-5 hauppauge '1' scancode:
249 .br
250 \fBir\-ctl \-S rc5:0x1e01\fR
251 .PP
252 To send the rc-5 hauppauage '1' key from the hauppauge keymap:
253 .br
254 \fBir\-ctl -k hauppauge.toml -K KEY_NUMERIC_1\fR
255 .SH BUGS
256 Report bugs to \fBLinux Media Mailing List <[email protected]>\fR
257 .SH COPYRIGHT
258 Copyright (c) 2016 by Sean Young.
259 .PP
260 License GPLv2: GNU GPL version 2 <http://gnu.org/licenses/gpl.html>.
261 .br
262 This is free software: you are free to change and redistribute it.
263 There is NO WARRANTY, to the extent permitted by law.
264 .SH SEE ALSO
265 To display decoded IR, or set IR decoding options, see
266 ir\-keytable(1).
267
268 The keymap format is described in rc_keymap(5).