| 1 |
.TH "CEC-COMPLIANCE" "1" "August 2016" "v4l-utils @MAN_PACKAGE_VERSION@" "User Commands" |
| 2 |
.SH NAME |
| 3 |
cec-compliance - An application to verify remote CEC devices |
| 4 |
.SH SYNOPSIS |
| 5 |
.B cec-compliance |
| 6 |
[\fI-h\fR] [\fI-d <dev>\fR] [other options] |
| 7 |
.SH DESCRIPTION |
| 8 |
The cec-compliance utility can be used to test how well remote CEC devices |
| 9 |
comply with the CEC specification. It can also be used to test the local |
| 10 |
CEC adapter (with the \fI-A\fR option). |
| 11 |
|
| 12 |
By default it will run through all tests, but if one or more of the feature |
| 13 |
test options is given, then only those tests will be performed. A set of core |
| 14 |
tests is always run. |
| 15 |
|
| 16 |
The CEC adapter needs to be configured before it is used to run tests with |
| 17 |
\fBcec-compliance\fR. Use \fBcec-ctl\fR for configuration. |
| 18 |
|
| 19 |
If the CEC adapter has claimed several logical addresses, the test set is run |
| 20 |
from each logical address in succession. The remote device needs to report a |
| 21 |
valid physical address in order to run tests on it. |
| 22 |
|
| 23 |
When running compliance tests, \fBcec-follower\fR should be run on the same |
| 24 |
adapter. \fBcec-follower\fR will reply to messages that are not handled by |
| 25 |
\fBcec-compliance\fR. \fBcec-follower\fR will also monitor the device under test |
| 26 |
for behaviors that are not compliant with the specification. Before each test-run |
| 27 |
\fBcec-follower\fR should be restarted if it is already running, to initialize |
| 28 |
the emulated device with a clean and known initial state. |
| 29 |
|
| 30 |
Some tests require interactive mode (with the \fI-i\fR option) to confirm that |
| 31 |
the test passed. When in interactive mode, the user is asked to observe or |
| 32 |
perform actions on the remote device. Some tests also give conclusive test |
| 33 |
results when run in interactive mode. |
| 34 |
|
| 35 |
When testing the local CEC adapter's compliance with the CEC API, there must be |
| 36 |
at least one remote device present in order to test transmitting and receiving. |
| 37 |
|
| 38 |
The compliance tests can have several possible outcomes besides passing and |
| 39 |
failing: |
| 40 |
|
| 41 |
OK The test passed. |
| 42 |
|
| 43 |
OK (Unexpected) The test passed, but it was unexpected for the device |
| 44 |
under test to support it. This might for example occur |
| 45 |
when a TV replies to messages in the Deck Control |
| 46 |
feature. |
| 47 |
|
| 48 |
OK (Not Supported) The feature that was tested is not supported by the |
| 49 |
device under test, and that feature was not mandatory for |
| 50 |
the device to pass. |
| 51 |
|
| 52 |
OK (Presumed) Nothing went wrong during the test, but the test cannot |
| 53 |
positively verify that the required effects of the test |
| 54 |
occurred. The test runner should verify that the test |
| 55 |
passed by manually observing the device under test. This |
| 56 |
is typically the test result for tests that send |
| 57 |
messages that are not replied to, but which induce some |
| 58 |
side effect on the device under test, such as a TV |
| 59 |
switching to another input or sending a Remote Control |
| 60 |
command. |
| 61 |
|
| 62 |
OK (Refused) The device supports the feature or message being tested, |
| 63 |
but responded <Feature Abort> ["Refused"] to indicate |
| 64 |
that it cannot perform the given operation. This might |
| 65 |
for example occur when trying to test the One Touch |
| 66 |
Record feature on a TV with copy protection enabled. |
| 67 |
|
| 68 |
FAIL The test failed and was expected to pass on the device. |
| 69 |
|
| 70 |
OK (Expected Failure) Failed but this was expected. This can only happen |
| 71 |
if the \fB\-\-expect\fR option was used that specified |
| 72 |
that a particular test would return a FAIL result. |
| 73 |
|
| 74 |
FAIL (Expected X, got Y) The test returned a different result than was expected. |
| 75 |
This can only happen if the \fB\-\-expect\fR option was used |
| 76 |
that specified that a particular test would return a specific |
| 77 |
non-FAIL result. |
| 78 |
|
| 79 |
Some tests depend on other tests being successful. These are not run if the |
| 80 |
tests they depend on failed, and they will not be shown in the test listing. |
| 81 |
.SH OPTIONS |
| 82 |
.TP |
| 83 |
\fB\-d\fR, \fB\-\-device\fR \fI<dev>\fR |
| 84 |
Use device <dev> as the CEC device. If <dev> is a number, then /dev/cec<dev> is used. |
| 85 |
.TP |
| 86 |
\fB\-D\fR, \fB\-\-driver\fR \fI<drv>\fR |
| 87 |
Use a cec device that has driver name \fI<drv>\fR, as returned by the CEC_ADAP_G_CAPS ioctl. |
| 88 |
This option can be combined with \fB\-a\fR to uniquely identify a CEC device without |
| 89 |
having to rely on the device node number. |
| 90 |
.TP |
| 91 |
\fB\-a\fR, \fB\-\-adapter\fR \fI<adap-name>\fR |
| 92 |
Use a cec device that has adapter name \fI<adap-name>\fR, as returned by the CEC_ADAP_G_CAPS ioctl. |
| 93 |
This option can be combined with \fB\-D\fR to uniquely identify a CEC device without |
| 94 |
having to rely on the device node number. |
| 95 |
.TP |
| 96 |
\fB\-E\fR, \fB\-\-exit\-on\-fail\fR |
| 97 |
Exit this application when the first failure occurs instead of continuing |
| 98 |
with a possible inconsistent state. |
| 99 |
.TP |
| 100 |
\fB\-l\fR, \fB\-\-list\-tests\fR |
| 101 |
List all tests and the possible test results. This is used by the \fB\-\-expect\fR |
| 102 |
option. |
| 103 |
.TP |
| 104 |
\fB\-e\fR, \fB\-\-expect\fR \fI<test>\fR=\fI<result>\fR |
| 105 |
\fB\-n\fR, \fB\-\-expect-with-no-warnings\fR \fI<test>\fR=\fI<result>\fR |
| 106 |
Fail if the test gave a different result. The \fB\-\-list\-tests\fR option |
| 107 |
lists all the possible tests and what result values can be used. |
| 108 |
|
| 109 |
This can be used in test scripts to verify that a specific result was returned |
| 110 |
by the test. One use-case is to verify that an optional feature is actually |
| 111 |
supported, so an \fIOK\fR result instead of an \fIOK (Not Supported)\fR result is expected. |
| 112 |
|
| 113 |
It can also be used to accept known failures. In that case the test will not |
| 114 |
fail, but return an \fIOK (Expected Failure)\fR result. |
| 115 |
|
| 116 |
The \fB\-\-expect-with-no-warnings\fR variant is more strict and will also |
| 117 |
check that the test produced no warnings. |
| 118 |
.TP |
| 119 |
\fB\-v\fR, \fB\-\-verbose\fR |
| 120 |
Turn on verbose reporting. |
| 121 |
.TP |
| 122 |
\fB\-\-version\fR |
| 123 |
Show version information. |
| 124 |
.TP |
| 125 |
\fB\-w\fR, \fB\-\-wall\-clock\fR |
| 126 |
Show timestamps as wall-clock time. |
| 127 |
.TP |
| 128 |
\fB\-S\fR, \fB\-\-show\-timestamp\fR |
| 129 |
For each test, show the timestamp of when the test started. |
| 130 |
.TP |
| 131 |
\fB\-T\fR, \fB\-\-trace\fR |
| 132 |
Trace all called ioctls. Useful for debugging. |
| 133 |
.TP |
| 134 |
\fB\-h\fR, \fB\-\-help\fR |
| 135 |
Prints the help message. |
| 136 |
.TP |
| 137 |
\fB\-W\fR, \fB\-\-exit\-on\-warn\fR |
| 138 |
Exit this application when the first warning occurs instead of continuing. |
| 139 |
.TP |
| 140 |
\fB\-s\fR, \fB\-\-skip\-info\fR |
| 141 |
Skip the Driver Info output section. |
| 142 |
.TP |
| 143 |
\fB\-C\fR, \fB\-\-color\fR \fI<when>\fR |
| 144 |
Highlight OK/warn/fail/FAIL strings with colors. OK is marked green, warn is |
| 145 |
marked bold, and fail/FAIL are marked bright red if enabled. \fI<when>\fR can |
| 146 |
be \fIalways\fR, \fInever\fR, or \fIauto\fR (the default). |
| 147 |
.TP |
| 148 |
\fB\-N\fR, \fB\-\-no\-warnings\fR |
| 149 |
Turn off warning messages. |
| 150 |
.TP |
| 151 |
\fB\-r\fR, \fB\-\-remote\fR \fI<la>\fR |
| 152 |
As initiator test the remote logical address <la> or all LAs if no LA was given. |
| 153 |
.TP |
| 154 |
\fB\-i\fR, \fB\-\-interactive\fR |
| 155 |
Interactive mode when doing remote tests. |
| 156 |
.TP |
| 157 |
\fB\-R\fR, \fB\-\-reply\-threshold\fR \fI<timeout>\fR |
| 158 |
Warn if replies take longer than this threshold (default 1000ms). |
| 159 |
.TP |
| 160 |
\fB\-t\fR, \fB\-\-timeout\fR \fI<secs>\fR |
| 161 |
Set the standby/resume timeout to the given number of seconds. Default is 60s. |
| 162 |
.TP |
| 163 |
\fB\-A\fR, \fB\-\-test\-adapter\fR |
| 164 |
Test the CEC adapter API |
| 165 |
.TP |
| 166 |
\fB\-F\fR, \fB\-\-test\-fuzzing\fR |
| 167 |
Test the remote CEC adapter by randomly creating CEC messages. |
| 168 |
This runs forever until an error occurs. |
| 169 |
.TP |
| 170 |
\fB\-\-test\-core\fR |
| 171 |
Test the core functionality |
| 172 |
.TP |
| 173 |
\fB\-\-test\-audio\-rate\-control\fR |
| 174 |
Test the Audio Rate Control feature |
| 175 |
.TP |
| 176 |
\fB\-\-test\-audio\-return\-channel\-control\fR |
| 177 |
Test the Audio Return Channel Control feature |
| 178 |
.TP |
| 179 |
\fB\-\-test\-capability\-discovery\-and\-control\fR |
| 180 |
Test the Capability Discovery and Control feature |
| 181 |
.TP |
| 182 |
\fB\-\-test\-deck\-control\fR |
| 183 |
Test the Deck Control feature |
| 184 |
.TP |
| 185 |
\fB\-\-test\-device\-menu\-control\fR |
| 186 |
Test the Device Menu Control feature |
| 187 |
.TP |
| 188 |
\fB\-\-test\-device\-osd\-transfer\fR |
| 189 |
Test the Device OSD Transfer feature |
| 190 |
.TP |
| 191 |
\fB\-\-test\-dynamic\-audio\-lipsync\fR |
| 192 |
Test the Dynamic Audio Lipsync feature |
| 193 |
.TP |
| 194 |
\fB\-\-test\-osd\-display\fR |
| 195 |
Test the OSD Display feature |
| 196 |
.TP |
| 197 |
\fB\-\-test\-one\-touch\-play\fR |
| 198 |
Test the One Touch Play feature |
| 199 |
.TP |
| 200 |
\fB\-\-test\-one\-touch\-record\fR |
| 201 |
Test the One Touch Record feature |
| 202 |
.TP |
| 203 |
\fB\-\-test\-power\-status\fR |
| 204 |
Test the Power Status feature |
| 205 |
.TP |
| 206 |
\fB\-\-test\-remote\-control\-passthrough\fR |
| 207 |
Test the Remote Control Passthrough feature |
| 208 |
.TP |
| 209 |
\fB\-\-test\-routing\-control\fR |
| 210 |
Test the Routing Control feature |
| 211 |
.TP |
| 212 |
\fB\-\-test\-system\-audio\-control\fR |
| 213 |
Test the System Audio Control feature |
| 214 |
.TP |
| 215 |
\fB\-\-test\-system\-information\fR |
| 216 |
Test the System Information feature |
| 217 |
.TP |
| 218 |
\fB\-\-test\-timer\-programming\fR |
| 219 |
Test the Timer Programming feature |
| 220 |
.TP |
| 221 |
\fB\-\-test\-tuner\-control\fR |
| 222 |
Test the Tuner Control feature |
| 223 |
.TP |
| 224 |
\fB\-\-test\-vendor\-specific\-commands\fR |
| 225 |
Test the Vendor Specific Commands feature |
| 226 |
.TP |
| 227 |
\fB\-\-test\-standby\-resume\fR |
| 228 |
Test standby and resume functionality. This will activate |
| 229 |
testing of Standby, Give Device Power Status and One Touch Play. |
| 230 |
|
| 231 |
.SH EXIT STATUS |
| 232 |
On success, it returns 0. Otherwise, it will return the error code. |
| 233 |
.SH EXAMPLE |
| 234 |
We want to test the compliance of a TV when it is interacting with a Playback |
| 235 |
device. The device node of the CEC adapter which the TV is connected to is |
| 236 |
/dev/cec1. |
| 237 |
|
| 238 |
The local CEC adapter first needs to be configured as a Playback device, and it |
| 239 |
must have an appropriate physical address. It is important that the physical |
| 240 |
address is correct, so as to not confuse the device under test. For example, if |
| 241 |
the CEC adapter is connected to the first input of the TV, the physical address |
| 242 |
1.0.0.0 should generally be used. |
| 243 |
|
| 244 |
cec-ctl -d1 --playback --phys-addr 1.0.0.0 |
| 245 |
|
| 246 |
Most CEC adapters will automatically detect the physical address, and for those |
| 247 |
adapters the \fI--phys-addr\fR option is not needed. |
| 248 |
|
| 249 |
Next, \fBcec-follower\fR also has to be started on the same device: |
| 250 |
|
| 251 |
cec-follower -d1 |
| 252 |
|
| 253 |
\fBcec-compliance\fR can now be run towards the TV by supplying the \fI-r\fR |
| 254 |
option with the logical address 0: |
| 255 |
|
| 256 |
cec-compliance -d1 -r0 |
| 257 |
.SH BUGS |
| 258 |
This manual page is a work in progress. |
| 259 |
|
| 260 |
Bug reports or questions about this utility should be sent to the [email protected] |
| 261 |
mailinglist. |
| 262 |
.SH SEE ALSO |
| 263 |
\fBcec-follower\fR(1), \fBcec-ctl\fR(1) |