| 1 |
# Only the system vendor should modify this file, ordinary users |
| 2 |
# should not have to change anything. |
| 3 |
|
| 4 |
[UPower] |
| 5 |
|
| 6 |
# Enable the Watts Up Pro device. |
| 7 |
# |
| 8 |
# The Watts Up Pro contains a generic FTDI USB device without a specific |
| 9 |
# vendor and product ID. When we probe for WUP devices, we can cause |
| 10 |
# the user to get a perplexing "Device or resource busy" error when |
| 11 |
# attempting to use their non-WUP device. |
| 12 |
# |
| 13 |
# The generic FTDI device is known to also be used on: |
| 14 |
# |
| 15 |
# - Sparkfun FT232 breakout board |
| 16 |
# - Parallax Propeller |
| 17 |
# |
| 18 |
# default=false |
| 19 |
EnableWattsUpPro=false |
| 20 |
|
| 21 |
# Don't poll the kernel for battery level changes. |
| 22 |
# |
| 23 |
# Some hardware will send us battery level changes through |
| 24 |
# events, rather than us having to poll for it. This option |
| 25 |
# allows disabling polling for hardware that sends out events. |
| 26 |
# |
| 27 |
# default=false |
| 28 |
NoPollBatteries=false |
| 29 |
|
| 30 |
# Do we ignore the lid state |
| 31 |
# |
| 32 |
# Some laptops are broken. The lid state is either inverted, or stuck |
| 33 |
# on or off. We can't do much to fix these problems, but this is a way |
| 34 |
# for users to make the laptop panel vanish, a state that might be used |
| 35 |
# by a couple of user-space daemons. On Linux systems, see also |
| 36 |
# logind.conf(5). |
| 37 |
# |
| 38 |
# default=false |
| 39 |
IgnoreLid=false |
| 40 |
|
| 41 |
# Policy for warnings and action based on battery levels |
| 42 |
# |
| 43 |
# Whether battery percentage based policy should be used. The default |
| 44 |
# is to use the time left, change to true to use the percentage, which |
| 45 |
# should work around broken firmwares. It is also more reliable than |
| 46 |
# the time left (frantically saving all your files is going to use more |
| 47 |
# battery than letting it rest for example). |
| 48 |
# default=true |
| 49 |
UsePercentageForPolicy=true |
| 50 |
|
| 51 |
# When UsePercentageForPolicy is true, the levels at which UPower will |
| 52 |
# consider the battery low, critical, or take action for the critical |
| 53 |
# battery level. |
| 54 |
# |
| 55 |
# This will also be used for batteries which don't have time information |
| 56 |
# such as that of peripherals. |
| 57 |
# |
| 58 |
# If any value is invalid, or not in descending order, the defaults |
| 59 |
# will be used. |
| 60 |
# |
| 61 |
# Defaults: |
| 62 |
# PercentageLow=20.0 |
| 63 |
# PercentageCritical=5.0 |
| 64 |
# PercentageAction=2.0 |
| 65 |
PercentageLow=20.0 |
| 66 |
PercentageCritical=5.0 |
| 67 |
PercentageAction=2.0 |
| 68 |
|
| 69 |
# When UsePercentageForPolicy is false, the time remaining in seconds at |
| 70 |
# which UPower will consider the battery low, critical, or take action for |
| 71 |
# the critical battery level. |
| 72 |
# |
| 73 |
# If any value is invalid, or not in descending order, the defaults |
| 74 |
# will be used. |
| 75 |
# |
| 76 |
# Defaults: |
| 77 |
# TimeLow=1200 |
| 78 |
# TimeCritical=300 |
| 79 |
# TimeAction=120 |
| 80 |
TimeLow=1200 |
| 81 |
TimeCritical=300 |
| 82 |
TimeAction=120 |
| 83 |
|
| 84 |
# Enable the risky CriticalPowerAction-Suspend |
| 85 |
# This option is not recommended, but it is here for users who |
| 86 |
# want to enable the risky CriticalPowerAction, such as "Suspend" |
| 87 |
# to fulfill their needs. |
| 88 |
# Default is false |
| 89 |
AllowRiskyCriticalPowerAction=false |
| 90 |
|
| 91 |
# If the user performs the battery recalibration, the battery behavior |
| 92 |
# will be set to "force discharge" and the user expects the battery will |
| 93 |
# be fully discharged. However, upower performs the |
| 94 |
# CriticalPowerAction earlier than the battery was fully discharged. |
| 95 |
# ExpectBatteryRecalibration allows upower to ignore the |
| 96 |
# CriticalPowerAction when the user attempts to perform the battery recalibration. |
| 97 |
# Default is false |
| 98 |
ExpectBatteryRecalibration=false |
| 99 |
|
| 100 |
# The action to take when "TimeAction" or "PercentageAction" above has been |
| 101 |
# reached for the batteries (UPS or laptop batteries) supplying the computer |
| 102 |
# |
| 103 |
# Possible values are: |
| 104 |
# PowerOff |
| 105 |
# Hibernate |
| 106 |
# HybridSleep |
| 107 |
# Auto (The CriticalPowerAction will be determined by the system) |
| 108 |
# Suspend (AllowRiskyCriticalPowerAction should be true to use this option but risky) |
| 109 |
# Ignore (AllowRiskyCriticalPowerAction should be true to use this option but risky) |
| 110 |
# |
| 111 |
# If Suspend isn't available or AllowRiskyCriticalPowerAction=false, HybridSleep will be used |
| 112 |
# If HybridSleep isn't available, Hibernate will be used |
| 113 |
# If Hibernate isn't available, PowerOff will be used |
| 114 |
CriticalPowerAction=Auto |