| 1 |
\documentclass[b1,largefonts,plainsections]{sciposter} |
| 2 |
% plainsections option works best in poster when using sectionboxes |
| 3 |
% b1 paper required for this conference |
| 4 |
% largefonts can be replaced by '30pt' if sciposter 1.14 or later is used |
| 5 |
|
| 6 |
\usepackage{amsmath} |
| 7 |
\usepackage{amssymb} |
| 8 |
\usepackage{sectionbox} |
| 9 |
\usepackage{multicol} |
| 10 |
\usepackage{verbatim} |
| 11 |
|
| 12 |
\newtheorem{Def}{Definition} |
| 13 |
|
| 14 |
|
| 15 |
\definecolor{SectionCol}{rgb}{0,0,0.5} |
| 16 |
% uncommented for dark blue \section text |
| 17 |
|
| 18 |
\definecolor{sectboxrulecol}{rgb}{0,0,0.5} |
| 19 |
\definecolor{sectboxfillcol}{rgb}{0.95,0.95,1} |
| 20 |
% defines sectionbox colours |
| 21 |
|
| 22 |
\definecolor{subsectboxrulecol}{rgb}{0,0.5,0} |
| 23 |
\definecolor{subsectboxfillcol}{rgb}{0.95,1,0.95} |
| 24 |
% defines subsectionbox colours (not used in this poster) |
| 25 |
|
| 26 |
\definecolor{subsubsectboxrulecol}{rgb}{0.5,0.5,0} |
| 27 |
\definecolor{subsubsectboxfillcol}{rgb}{1,1,0.9} |
| 28 |
% defines subsectionbox colours (not used in this poster) |
| 29 |
|
| 30 |
\shadowsectionbox % selects shadow mode for sectionbox |
| 31 |
|
| 32 |
\renewcommand{\titlesize}{\huge} |
| 33 |
\renewcommand{\authorsize}{\Large} |
| 34 |
%smaller title size preferable on ISO B1 paper |
| 35 |
|
| 36 |
\title{Connected Morphological Image Analysis} |
| 37 |
|
| 38 |
% Note: only give author names, not institute |
| 39 |
\author{Michael H. F. Wilkinson, Erik R. Urbach, Georgios K. Ouzounis} |
| 40 |
|
| 41 |
|
| 42 |
% Insert correct institute name |
| 43 |
\institute{Institute for Mathematics and Computing Science\\ |
| 44 |
University of Groningen\\} |
| 45 |
|
| 46 |
\email{(michael,erik,georgios)@cs.rug.nl} % shows author email address below institute |
| 47 |
|
| 48 |
%\date is unused by the current \maketitle |
| 49 |
|
| 50 |
%\definecolor{mainCol}{rgb}{1.0,1.0,0.9} |
| 51 |
% uncomment for pale yellow background |
| 52 |
|
| 53 |
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% |
| 54 |
%%% Begin of Document |
| 55 |
|
| 56 |
\begin{document} |
| 57 |
|
| 58 |
%define conference poster is presented at (appears as footer) |
| 59 |
|
| 60 |
\conference{{\bf SIREN 2005}, Scientific ICT Research Event, the Netherlands, 6 October 2005, Eindhoven, the Netherlands} |
| 61 |
|
| 62 |
|
| 63 |
\maketitle |
| 64 |
|
| 65 |
%%% Begin of Multicols-Enviroment |
| 66 |
\setlength{\columnseprule}{0pt} |
| 67 |
\setlength{\columnsep}{0.0192\textheight} |
| 68 |
|
| 69 |
\begin{multicols}{2} |
| 70 |
%\setcounter{unbalance}{14} |
| 71 |
% this controls the column balance (not needed now) |
| 72 |
|
| 73 |
|
| 74 |
\newcommand{\imsize}{0.3\columnwidth} |
| 75 |
|
| 76 |
|
| 77 |
\begin{sectionbox}{Connected Operators} |
| 78 |
Connected operators are a subset of morphological image and signal |
| 79 |
processing operators which are strongly shape preserving. They |
| 80 |
can perform both high and low level image processing tasks |
| 81 |
such as noise removal and object recognition respectively. |
| 82 |
|
| 83 |
% NOTE: figure (or other float) ONLY allowed because sciposter.cls |
| 84 |
% redefines these environments to non-floating counterparts! |
| 85 |
% |
| 86 |
\begin{figure} |
| 87 |
\begin{center} |
| 88 |
\begin{tabular}{c c c} |
| 89 |
\resizebox{\imsize}{!}{\includegraphics{lenna10pct}}& |
| 90 |
\resizebox{\imsize}{!}{\includegraphics{lenna10smooth}}& |
| 91 |
\resizebox{\imsize}{!}{\includegraphics{lenna10connect}} |
| 92 |
\end{tabular} |
| 93 |
\end{center} |
| 94 |
\caption{Image corrupted by speckle noise (left) smoothed by gaussian |
| 95 |
blurring (middle) and by area open - close (right)} |
| 96 |
\end{figure} |
| 97 |
\vspace{-0.5\baselineskip} |
| 98 |
% useful if a sectionbox ends with a figure |
| 99 |
\end{sectionbox} |
| 100 |
\vfill |
| 101 |
|
| 102 |
\begin{sectionbox}{Extensions to Attributes} |
| 103 |
By choosing the object properties or \emph{attributes} on which |
| 104 |
filtering is based, it is possible to obtain many different types of |
| 105 |
filter. More importantly, it is possible to filter in ways invariant |
| 106 |
to operations such as rotation, translation and scaling, providing |
| 107 |
filtering based on shape, rather than size. |
| 108 |
\begin{figure} |
| 109 |
\begin{center} |
| 110 |
\resizebox{0.92\columnwidth}{!}{\includegraphics{orig}}\\[1.5ex] |
| 111 |
\resizebox{0.92\columnwidth}{!}{\includegraphics{lambda2}} |
| 112 |
\end{center} |
| 113 |
\caption{Scale-invariant filtering of magnetic resonance angiogram |
| 114 |
using elongation criteria.} |
| 115 |
\end{figure} |
| 116 |
|
| 117 |
In the above examples, scalar attributes are used in connected |
| 118 |
filters, but using vector-attributes has been developed here, and |
| 119 |
allows even more control over the filtering process. |
| 120 |
\end{sectionbox} |
| 121 |
|
| 122 |
\vfill |
| 123 |
\begin{sectionbox}{Extensions to Connectivity} |
| 124 |
Connected filters use the notion of connectivity, and various |
| 125 |
theoretical extensions are available (see poster ``Generalized |
| 126 |
connected morphological opertors for robust shape extraction''). |
| 127 |
\end{sectionbox}\\ |
| 128 |
\begin{sectionbox}{Pattern Spectra} |
| 129 |
Connected filters allow very fast computation of so-called |
| 130 |
patter-spectra. These are histograms of the amount of image content in |
| 131 |
different shape and size categories (see Figure~\ref{fig:spectra}). |
| 132 |
These methods could also be used for content-based image retrieval. |
| 133 |
|
| 134 |
\begin{figure} |
| 135 |
\begin{center} |
| 136 |
\begin{tabular}{c c} |
| 137 |
\resizebox{!}{\imsize}{\includegraphics{000074Bzones}}& |
| 138 |
\resizebox{!}{\imsize}{\includegraphics{000074Bpatspec}}\\[0.5ex] |
| 139 |
\resizebox{!}{\imsize}{\includegraphics{000175Bzones}}& |
| 140 |
\resizebox{!}{\imsize}{\includegraphics{000175Bpatspec}}\\[0.5ex] |
| 141 |
\resizebox{!}{\imsize}{\includegraphics{002000AAzones}}& |
| 142 |
\resizebox{!}{\imsize}{\includegraphics{002000AApatspec}}\\ |
| 143 |
\end{tabular} |
| 144 |
\end{center} |
| 145 |
\caption{Three diatom images with the corresponding pattern spectra: |
| 146 |
The vertical axis shows the area, the horizontal the elongation of |
| 147 |
image features in each bin; brightness indicates the power in each |
| 148 |
bin. One selected bin in each spectrum and the corresponding image |
| 149 |
details are highlighted in orange.} |
| 150 |
\label{fig:spectra} |
| 151 |
\end{figure} |
| 152 |
\vspace{-0.5\baselineskip} |
| 153 |
% useful if a sectionbox ends with a figure |
| 154 |
\end{sectionbox} |
| 155 |
|
| 156 |
\vfill |
| 157 |
|
| 158 |
\begin{sectionbox}{Algorithm Development} |
| 159 |
New algorithms for area and attribute openings and closings based on |
| 160 |
Tarjan's union-find have been developed. These are currently the |
| 161 |
fastest algorithms available, and form the basis of a parallel |
| 162 |
implementation being developed. |
| 163 |
\end{sectionbox} |
| 164 |
|
| 165 |
\vfill |
| 166 |
|
| 167 |
\renewcommand{\refname}{Selected Publications} |
| 168 |
% changes section heading over bibliography |
| 169 |
|
| 170 |
\nocite{ouzounis05:_count_overs_partit_based_connec} |
| 171 |
\nocite{ouzounis05:_secon_order_connec_attrib_filter} |
| 172 |
\nocite{urbach05:_vector_attrib_filter} |
| 173 |
\nocite{wilkinson01:_shape_preser_filam_enhan_filter} |
| 174 |
\nocite{Meijster:Wilkinson:PAMI} |
| 175 |
% these statements force these entries into the bibliography even |
| 176 |
% though they have not been cited. |
| 177 |
|
| 178 |
|
| 179 |
\begin{sectionbox}{} % Leave sectionbox heading empty for bibliography. |
| 180 |
\bibliographystyle{plain} % enter bibligraphy as usual, with or without using |
| 181 |
% BiBTeX |
| 182 |
|
| 183 |
\small % this only affects contents, not |
| 184 |
% bibliography heading size in |
| 185 |
% sciposter clas |
| 186 |
\bibliography{sectionboxexample} |
| 187 |
\end{sectionbox} |
| 188 |
|
| 189 |
\end{multicols} |
| 190 |
|
| 191 |
\end{document} |
| 192 |
|