| 1 |
set test "atomic" |
| 2 |
|
| 3 |
if {![installtest_p]} {untested $test; return} |
| 4 |
|
| 5 |
# |
| 6 |
# First test atomic_long_read() |
| 7 |
# |
| 8 |
|
| 9 |
set script_template { |
| 10 |
probe begin { |
| 11 |
print("systemtap starting probe\n") |
| 12 |
exit() |
| 13 |
} |
| 14 |
|
| 15 |
probe end { |
| 16 |
print("systemtap ending probe\n") |
| 17 |
printf("%%d\n", %s_read(%s)) |
| 18 |
} |
| 19 |
} |
| 20 |
|
| 21 |
# First try reading from address 0, which should fail. |
| 22 |
set test "atomic1" |
| 23 |
set error {read fault .* at 0x[^\r]+} |
| 24 |
set script [format $script_template "atomic_long" "0"] |
| 25 |
# s390x machines don't error when reading address 0 |
| 26 |
if {[istarget s390x-*-*]} { setup_kfail S390X [istarget] } |
| 27 |
stap_run_error $test 1 $error "0\r\n" -e $script |
| 28 |
|
| 29 |
# Try reading from address -1 (top of memory), which should fail. |
| 30 |
set test "atomic2" |
| 31 |
set script [format $script_template "atomic_long" "-1"] |
| 32 |
stap_run_error $test 1 $error "0\r\n" -e $script |
| 33 |
|
| 34 |
# Try reading from address 3, which should fail (if nothing else |
| 35 |
# because it isn't aligned properly). |
| 36 |
set test "atomic3" |
| 37 |
set script [format $script_template "atomic_long" "3"] |
| 38 |
# s390x machines don't error when reading address 3 |
| 39 |
if {[istarget s390x-*-*]} { setup_kfail S390X [istarget] } |
| 40 |
stap_run_error $test 1 $error "0\r\n" -e $script |
| 41 |
|
| 42 |
# Since we want to fail semi-gracefully (no compile errors), if we |
| 43 |
# don't have atomic_long_t support on this kernel (no |
| 44 |
# ATOMIC_LONG_INIT) the testcase will compile, but fail. |
| 45 |
|
| 46 |
set atomic_long_script_module_template { |
| 47 |
%%{ |
| 48 |
#include <asm/atomic.h> |
| 49 |
#ifdef ATOMIC_LONG_INIT |
| 50 |
struct { |
| 51 |
ulong barrier1; |
| 52 |
atomic_long_t a; |
| 53 |
ulong barrier2; |
| 54 |
} stp_atomic_struct = { ULONG_MAX, ATOMIC_LONG_INIT(5), ULONG_MAX }; |
| 55 |
#else |
| 56 |
struct { |
| 57 |
ulong barrier1; |
| 58 |
long a; |
| 59 |
ulong barrier2; |
| 60 |
} stp_atomic_struct = { ULONG_MAX, 5, ULONG_MAX }; |
| 61 |
#endif |
| 62 |
%%} |
| 63 |
|
| 64 |
function get_atomic_long_addr:long() |
| 65 |
%%{ |
| 66 |
STAP_RETVALUE = (long)&stp_atomic_struct.a; |
| 67 |
%%} |
| 68 |
|
| 69 |
probe begin { |
| 70 |
print("systemtap starting probe\n") |
| 71 |
exit() |
| 72 |
} |
| 73 |
|
| 74 |
probe end { |
| 75 |
print("systemtap ending probe\n") |
| 76 |
printf("%%d\n", atomic_long_read(get_atomic_long_addr() + %s)) |
| 77 |
} |
| 78 |
} |
| 79 |
|
| 80 |
set test "atomic4" |
| 81 |
set script [format $atomic_long_script_module_template "0"] |
| 82 |
stap_run_error $test 0 $error "5\r\n" -ge $script |
| 83 |
|
| 84 |
# We should be able to check for trying to read the atomic_long_t with |
| 85 |
# bad alignment here, but it succeeds on {x86, x86_64} and fails on |
| 86 |
# ia64. Since it doesn't fail consistently, we'll comment this out. |
| 87 |
#set test "atomic5" |
| 88 |
#set script [format $atomic_long_script_module_template "3"] |
| 89 |
#stap_run_error $test 1 $error "" -ge $script |
| 90 |
|
| 91 |
# |
| 92 |
# Now test atomic_read() |
| 93 |
# |
| 94 |
|
| 95 |
# First try reading from address 0, which should fail. |
| 96 |
set test "atomic5" |
| 97 |
set error {read fault .* at 0x[^\r]+} |
| 98 |
set script [format $script_template "atomic" "0"] |
| 99 |
# s390x machines don't error when reading address 0 |
| 100 |
if {[istarget s390x-*-*]} { setup_kfail S390X [istarget] } |
| 101 |
stap_run_error $test 1 $error "0\r\n" -e $script |
| 102 |
|
| 103 |
# Try reading from address -1 (top of memory), which should fail. |
| 104 |
set test "atomic6" |
| 105 |
set script [format $script_template "atomic" "-1"] |
| 106 |
stap_run_error $test 1 $error "0\r\n" -e $script |
| 107 |
|
| 108 |
# Try reading from address 3, which should fail (if nothing else |
| 109 |
# because it isn't aligned properly). |
| 110 |
set test "atomic7" |
| 111 |
set script [format $script_template "atomic" "3"] |
| 112 |
# s390x machines don't error when reading address 3 |
| 113 |
if {[istarget s390x-*-*]} { setup_kfail S390X [istarget] } |
| 114 |
stap_run_error $test 1 $error "0\r\n" -e $script |
| 115 |
|
| 116 |
set atomic_script_module_template { |
| 117 |
%%{ |
| 118 |
#include <asm/atomic.h> |
| 119 |
struct { |
| 120 |
ulong barrier1; |
| 121 |
atomic_t a; |
| 122 |
ulong barrier2; |
| 123 |
} stp_atomic_struct = { ULONG_MAX, ATOMIC_INIT(5), ULONG_MAX }; |
| 124 |
%%} |
| 125 |
|
| 126 |
function get_atomic_addr:long() |
| 127 |
%%{ |
| 128 |
STAP_RETVALUE = (long)&stp_atomic_struct.a; |
| 129 |
%%} |
| 130 |
|
| 131 |
probe begin { |
| 132 |
print("systemtap starting probe\n") |
| 133 |
exit() |
| 134 |
} |
| 135 |
|
| 136 |
probe end { |
| 137 |
print("systemtap ending probe\n") |
| 138 |
printf("%%d\n", atomic_read(get_atomic_addr() + %s)) |
| 139 |
} |
| 140 |
} |
| 141 |
|
| 142 |
set test "atomic8" |
| 143 |
set script [format $atomic_script_module_template "0"] |
| 144 |
stap_run_error $test 0 $error "5\r\n" -ge $script |
| 145 |
|
| 146 |
# We should be able to check for trying to read the atomic_t with |
| 147 |
# bad alignment here, but it succeeds on {x86, x86_64} and fails on |
| 148 |
# ia64. Since it doesn't fail consistently, we'll comment this out. |
| 149 |
#set test "atomic9" |
| 150 |
#set script [format $atomic_script_module_template "3"] |
| 151 |
#stap_run_error $test 1 $error "" -ge $script |