| 1 |
Plustek.changes - Gerhard Jaeger <[email protected]> |
| 2 |
===================================================== |
| 3 |
|
| 4 |
Note: All other not mentioned builds have never been released. |
| 5 |
|
| 6 |
V 0.52-11 (2013-02-13) |
| 7 |
--------------------- |
| 8 |
Added support for Q-Scan A6 scanner (see report #312073) |
| 9 |
|
| 10 |
V 0.52-10 (2012-03-19) |
| 11 |
--------------------- |
| 12 |
Fixed batch scanning |
| 13 |
|
| 14 |
V 0.52-9 (2009-04-27) |
| 15 |
--------------------- |
| 16 |
Tweaked highspeed settings for Epson 1260 |
| 17 |
|
| 18 |
V 0.52-8 (2008-08-25) |
| 19 |
--------------------- |
| 20 |
Added preliminary support for Visioneer XP100 |
| 21 |
Tweaked entry for LM9831 version of Plustek UT12 |
| 22 |
|
| 23 |
V 0.52-7 (2007-12-13) |
| 24 |
--------------------- |
| 25 |
Fixed alignment issues for archs like XScale/ARM |
| 26 |
Fixed dumppic function to get valid grayscale pictures |
| 27 |
|
| 28 |
V 0.52-6 (2007-11-23) |
| 29 |
--------------------- |
| 30 |
Tweaked TravelScan464 settings. |
| 31 |
Improved AFE gain calculation for CIS devices. This should avoid |
| 32 |
stripes in the scanned images. |
| 33 |
|
| 34 |
V 0.52-4 (2007-11-16) |
| 35 |
--------------------- |
| 36 |
Tweaked TravelScan464 settings |
| 37 |
Added possibility to disable dark-calibration with lamp on |
| 38 |
(touches devices like CanoScan1220 etc) |
| 39 |
Use attribute packed for data access structs |
| 40 |
|
| 41 |
V 0.52-4 (2007-11-07) |
| 42 |
--------------------- |
| 43 |
Added support for Syscan TravelScan464 |
| 44 |
|
| 45 |
V 0.52-3 (2007-07-26) |
| 46 |
--------------------- |
| 47 |
Checked UMAX3400/3450 models |
| 48 |
Force output bit set (MIO), when lamp is switched |
| 49 |
|
| 50 |
V 0.52-2 (2007-07-10) |
| 51 |
--------------------- |
| 52 |
Added flag to allow only 1- and 8-bit scanmodes. The Q-Scan does |
| 53 |
not seem to support 14-bit modes. |
| 54 |
|
| 55 |
V 0.52-1 (2007-06-29) |
| 56 |
--------------------- |
| 57 |
|
| 58 |
Added sheetfed device Q-Scan USB001 from Portable Peripherals |
| 59 |
Fixed Mustek Bearpaw and did some speedup (bugreports #304343 and |
| 60 |
#301763) |
| 61 |
Fixed calibration for senororders other that RGB |
| 62 |
|
| 63 |
V 0.51-16 (2007-03-05) |
| 64 |
---------------------- |
| 65 |
|
| 66 |
Added CanoScan to all Canon device strings. |
| 67 |
Identified one more Plustek device as U24. |
| 68 |
Fixed button handling for Plustek/KYE devices and |
| 69 |
added some more debug messages. |
| 70 |
|
| 71 |
V 0.51-15 (2006-11-22) |
| 72 |
---------------------- |
| 73 |
Fixed option descriptors (bugreport #303786) |
| 74 |
|
| 75 |
V 0.51-14 (2006-08-11) |
| 76 |
---------------------- |
| 77 |
Lowered speed for LiDE20/30 models in low resolution mode (<75dpi) |
| 78 |
|
| 79 |
V 0.51-13 (2006-08-09) |
| 80 |
---------------------- |
| 81 |
Changed sane.type to "flatbed scanner" only |
| 82 |
Fixed motorsettings for LiDE30 (bugreport #303722) |
| 83 |
Fixed LiDE20 settings. Got some reports of non-working devs, although |
| 84 |
my N670U is working fine. Lowered the max speeds and increased the |
| 85 |
MCLK-div for fast movement. (bugreport #303695) |
| 86 |
|
| 87 |
V 0.51-12 (2006-06-30) |
| 88 |
---------------------- |
| 89 |
Fixed bit-depth selection |
| 90 |
|
| 91 |
V 0.51-11 (2006-06-08) |
| 92 |
---------------------- |
| 93 |
Fixed calibration: All modes will be coarse calibrated now, fine calibration |
| 94 |
will be done only for 8 bit modes. |
| 95 |
Fixed paper eject during startup. |
| 96 |
|
| 97 |
V 0.51-10 (2006-05-28) |
| 98 |
--------------------- |
| 99 |
Released |
| 100 |
|
| 101 |
V 0.51-8 (2006-04-09) |
| 102 |
--------------------- |
| 103 |
Added cache for fine calibration (CIS devices only) |
| 104 |
Added support for sheet-fed scanner (CIS devices only) |
| 105 |
Added support for Syscan TravelScan662 |
| 106 |
|
| 107 |
V 0.50-10 (2006-01-31) |
| 108 |
--------------------- |
| 109 |
Fixed CanoScan N1220U settings. |
| 110 |
|
| 111 |
V 0.50-9 (2006-01-19) |
| 112 |
--------------------- |
| 113 |
Added high-speed setting for HP2200. |
| 114 |
Fixed constraint_type for OPT_BUTTON. |
| 115 |
|
| 116 |
V 0.50-8 (2006-01-18) |
| 117 |
--------------------- |
| 118 |
Fixed CanoScan N670U settings (bugreport #302433). |
| 119 |
|
| 120 |
V 0.50-7 (2005-10-28) |
| 121 |
--------------------- |
| 122 |
Changed high-speed setting for UMAX 3400, due to bugreport #302317. |
| 123 |
Added disable speeup feature (as option). |
| 124 |
Fixed CanoScan N650U settings (bugreport #302433). |
| 125 |
|
| 126 |
V 0.50-6 (2005-10-25) |
| 127 |
--------------------- |
| 128 |
Fixed segfault in fine calibration for CIS devices. |
| 129 |
Tweaked LiDE25 settings (thanks to Gerd Cendelin for lending me |
| 130 |
his LiDE25). |
| 131 |
Let 1200DPI CIS devices use now the green-channel for gray scans. |
| 132 |
|
| 133 |
V 0.50-5 (2005-10-21) |
| 134 |
--------------------- |
| 135 |
Fixed high-speed feature of CanoScan D660U. |
| 136 |
|
| 137 |
V 0.50-4 (2005-10-02) |
| 138 |
--------------------- |
| 139 |
Updated motor settings for Canoscan LiDE25, thanks to |
| 140 |
Stephan February <[email protected]> for providing these |
| 141 |
values. |
| 142 |
|
| 143 |
V 0.50-3 (2005-08-22) |
| 144 |
--------------------- |
| 145 |
Fixed problem, when trying to scan at resolutions beyond the |
| 146 |
optical one (sensor stops too early) |
| 147 |
|
| 148 |
V 0.50-2 (2005-08-19) |
| 149 |
--------------------- |
| 150 |
More cleanup. |
| 151 |
Removed obsolete _WAF_BLACKFINE. |
| 152 |
LiDE20 does not seem to have a reliable black calibration area, |
| 153 |
so the devices now will switch off the lamp for dark calibration. |
| 154 |
Fixed line statistics and added calibration data output. |
| 155 |
|
| 156 |
V 0.50-1 (2005-08-15) |
| 157 |
--------------------- |
| 158 |
Cleanup |
| 159 |
Activated IPC between reader-process and parent |
| 160 |
Added button support for Plustek/Genius devices |
| 161 |
Did some whitespace cleanup and removed those *p typedefs |
| 162 |
Tried to improve CIS calibration (somewhat back to 1.0.13) |
| 163 |
Added _TWEAK_GAIN definition to allow CIS calibration increase |
| 164 |
gain values during basic lamp setup phase |
| 165 |
Added call to speedtest to CIS calibration |
| 166 |
Fixed CanoScan startup problem (the way misc I/Os will be set |
| 167 |
after power-up has done the trick) |
| 168 |
|
| 169 |
V 0.49-8 (2005-08-08) |
| 170 |
--------------------- |
| 171 |
Added LiDE25 settings |
| 172 |
|
| 173 |
V 0.49-7 (2005-07-21) |
| 174 |
--------------------- |
| 175 |
Bugfix release - fixed lampsettings for CIS calibration |
| 176 |
|
| 177 |
V 0.49-6 (2005-07-07) |
| 178 |
--------------------- |
| 179 |
Bugfix release - calibration and segfault :( |
| 180 |
|
| 181 |
V 0.49-5 (2005-07-04) |
| 182 |
--------------------- |
| 183 |
Added IPC between reader-process and parent process to |
| 184 |
be pepared for sharing calibration info. |
| 185 |
Added button support for backend |
| 186 |
|
| 187 |
V 0.49-4 (2005-06-27) |
| 188 |
--------------------- |
| 189 |
Fixed "double free" problem during sane_exit. |
| 190 |
|
| 191 |
V 0.49-3 (2005-04-18) |
| 192 |
--------------------- |
| 193 |
Fixed backtracking problem, when sensor-speedup is active. |
| 194 |
|
| 195 |
V 0.49-2 (2005-01-12) |
| 196 |
--------------------- |
| 197 |
Tweaked some device settings |
| 198 |
Updated copyright info |
| 199 |
Using now PhyDpi.y as selector for the motor MCLK range |
| 200 |
|
| 201 |
V 0.49-1 (2004-11-19) |
| 202 |
--------------------- |
| 203 |
Improved multi-device capability |
| 204 |
|
| 205 |
V 0.48-10 (2004-10-30) |
| 206 |
---------------------- |
| 207 |
- Fixed a bug in buffer calculation for CIS devices |
| 208 |
|
| 209 |
V 0.48-9 (2004-10-19) |
| 210 |
--------------------- |
| 211 |
- Use the same option names for RGB gain as umax_pp backend |
| 212 |
|
| 213 |
V 0.48-8 (2004-10-06) |
| 214 |
--------------------- |
| 215 |
- split scanmodes & bit-depths |
| 216 |
|
| 217 |
V 0.48-7 (2004-10-04) |
| 218 |
--------------------- |
| 219 |
- changed some strings according to bug #300963 |
| 220 |
|
| 221 |
V 0.48-6 (2004-09-07) |
| 222 |
--------------------- |
| 223 |
- fixed UMAX lamp-off bug |
| 224 |
|
| 225 |
V 0.48-4 (2004-07-26) |
| 226 |
--------------------- |
| 227 |
- added speedup parameters for UMAX3400/3450 |
| 228 |
- added disableSpeedup option |
| 229 |
- added UMAX3400/3450 TPA autodetection |
| 230 |
|
| 231 |
V 0.48-3 (2004-07-16) |
| 232 |
--------------------- |
| 233 |
- improved autowarmup feature |
| 234 |
- improved speedup feature |
| 235 |
|
| 236 |
V 0.48-2 (2004-07-07) |
| 237 |
--------------------- |
| 238 |
- fixed binary mode for CanoScan D660U |
| 239 |
|
| 240 |
V 0.48-1 (2004-07-02) |
| 241 |
--------------------- |
| 242 |
- added more options to the frontend interface |
| 243 |
- added UMAX 3400 with product ID 0x0050 |
| 244 |
- added support for the UMAX 3450 |
| 245 |
- added autowarmup for CFL (most CCD-scanner) |
| 246 |
- added speedup for sensor for some devices |
| 247 |
- fixed lamp switching problem for D660U |
| 248 |
- fixed negative scanning lamp problem |
| 249 |
- fixed Gray 16 mode for CanoScan D660U |
| 250 |
- code cleanup |
| 251 |
|
| 252 |
V 0.47-11 (2004-04-21) |
| 253 |
---------------------- |
| 254 |
- minor fixes, esp. for MacOSX |
| 255 |
- added lamp-off and warmup options to be configurable by backends |
| 256 |
|
| 257 |
V 0.47-8 - 0.47-10 |
| 258 |
------------------ |
| 259 |
- never released |
| 260 |
|
| 261 |
V 0.47-7 (2004-02-08) |
| 262 |
--------------------- |
| 263 |
- fixed bypass calibration function for CIS devices |
| 264 |
- added lampoff stuff to config file |
| 265 |
|
| 266 |
V 0.47-6 (2004-01-21) |
| 267 |
--------------------- |
| 268 |
- Cleanup work |
| 269 |
- Changed lamp off timer for non-setitimer systems |
| 270 |
|
| 271 |
V 0.47-5 (2004-01-09) |
| 272 |
--------------------- |
| 273 |
- Added big-endian code to support also PPC architectures |
| 274 |
- Added mov (model override) to support various devices using |
| 275 |
the same product ID (namely Mustek BearPaw 1200) |
| 276 |
- Added per-model gamma values |
| 277 |
- Fixed a bug in the coarse CIS-lamp calibration |
| 278 |
- Cleanup work |
| 279 |
|
| 280 |
V 0.47-1 - 0.47-4 |
| 281 |
----------------- |
| 282 |
- never released |
| 283 |
|
| 284 |
V 0.46-9 (2003-11-03) |
| 285 |
--------------------- |
| 286 |
- Added alternate calibration for CIS devices |
| 287 |
- Added coarse calibration data-cache |
| 288 |
- Moved parallelport code to extra backend file plustek_pp |
| 289 |
- Fixed some minor bugs |
| 290 |
- Fixed problem with CIS devices using FreeBSD |
| 291 |
|
| 292 |
V 0.46-1 - 0.46-8 |
| 293 |
----------------- |
| 294 |
- never released |
| 295 |
|
| 296 |
V 0.45 (2003-08-05) |
| 297 |
------------------- |
| 298 |
- Starting this changelog |
| 299 |
- Updates since V 0.44: |
| 300 |
* better CIS device support |
| 301 |
* added CanoScan N1220U, N1240U |
| 302 |
* made CanoScan N650U and N670U work |
| 303 |
* fixed EPSON 1260 motor killer-bug |
| 304 |
* improved TPA scanning |
| 305 |
* fixed TPA warmup bug on EPSON 1260/Photo |
| 306 |
* fixed Genius device detection problem |
| 307 |
* Added Compaq S4-100 (identical to UMAX3400) |