| 1 |
README FOR CAP |
| 2 |
|
| 3 |
The Coefficiients and Properties (CAP) computer code is described |
| 4 |
in NASA/TP--2001-210595 available from the CEA website. See "Codes |
| 5 |
related to thermodynamic properties of individual species..." |
| 6 |
|
| 7 |
http://www.grc.nasa.gov/WWW/CEAWeb/ |
| 8 |
|
| 9 |
The report provides a detailed description of input preparation and |
| 10 |
examples of input and output for many species. |
| 11 |
|
| 12 |
The program permits the generation of tabulated thermodynamic functions |
| 13 |
from NASA least-squares coefficients. CAP provides considerable |
| 14 |
flexibility in the output format, the temperature schedule, and the |
| 15 |
energy units of the calculated properties. ThermoBuild at the following |
| 16 |
website is similar except for the fact that it uses the NASA thermo |
| 17 |
database and does not allow for as much flexibility in energy units. |
| 18 |
|
| 19 |
http://cea.grc.nasa.gov/ |
| 20 |
|
| 21 |
The Fortran source code and associated data are available at the |
| 22 |
following internet URL: |
| 23 |
|
| 24 |
ftp://ftp.grc.nasa.gov/users/xxminna/CEA+Fortran/cap/ |
| 25 |
|
| 26 |
GENERAL INFORMATION TO GET STARTED: |
| 27 |
|
| 28 |
1) Compile the fortran program cap.f. Note that compilers |
| 29 |
are freely available from the CEAWeb. |
| 30 |
2) When executing CAP, the file cap.elms must be available |
| 31 |
if heats of formation and log K values are desired. |
| 32 |
3) Input and output files as assumed to be standard input |
| 33 |
(I/O unit 5) and standard output (I/O/ unit 6). OPEN |
| 34 |
statements may be added to the source code. |
| 35 |
4) Run the executable with the provided example "cap.in",e.g.: |
| 36 |
|
| 37 |
cap.x < cap.in > cap.out |
| 38 |
|
| 39 |
Generally, the input consists of 2 records followed by any number of |
| 40 |
sets of coefficients in the format of 9 coefficients for Cp--see |
| 41 |
ThermoBuild (details given in "About ThermoBuild") or the CAP manual. |
| 42 |
The first record contains options in the form of keywords. The |
| 43 |
second record indicates the desired T schedule. These records are |
| 44 |
also descrided in source code comments. |
| 45 |
|
| 46 |
CAP will generate output tables for each species whoses coefficients |
| 47 |
are provided. An unlimited number of species may be run. For species |
| 48 |
with several phases, the phases must be supplied in increasing order |
| 49 |
by temperature. If the temperature schedule in record 2 exceeds the |
| 50 |
range of the coefficients, CAP will use the coefficients for up to |
| 51 |
20 percent beyond the endpoint. |
| 52 |
|
| 53 |
The file "cap.elms" contains coefficients for the reference elements. |
| 54 |
These data may be revised or expanded. |
| 55 |
|
| 56 |
If you have any comments or questions, please contact [email protected]. |