| 1 |
// Copyright (C) 2023 The Qt Company Ltd. |
| 2 |
// SPDX-License-Identifier: LicenseRef-Qt-Commercial OR GFDL-1.3-no-invariants-only |
| 3 |
|
| 4 |
/*! \example modbus/client |
| 5 |
\title Modbus Client |
| 6 |
\ingroup qtserialbus-examples |
| 7 |
\examplecategory Connectivity |
| 8 |
|
| 9 |
\brief The example implements a Modbus client application. |
| 10 |
|
| 11 |
The example acts as Modbus client sending Modbus request via serial line |
| 12 |
or TCP. The shown dialog allows the definition of standard requests and |
| 13 |
displays incoming responses. |
| 14 |
|
| 15 |
The example must be used in conjunction with the |
| 16 |
\l {modbus/server}{Modbus Server example} or another Modbus device which is |
| 17 |
either connected via TCP or Serial Port. |
| 18 |
|
| 19 |
Key classes used in this example: |
| 20 |
|
| 21 |
\list |
| 22 |
\li \l QModbusClient |
| 23 |
\li \l QModbusDataUnit |
| 24 |
\li \l QModbusReply |
| 25 |
\endlist |
| 26 |
|
| 27 |
\image ../images/modbusclient.png |
| 28 |
|
| 29 |
\section1 Creating a QModbusClient |
| 30 |
|
| 31 |
An instance of \l QModbusClient is required to perform any communication. |
| 32 |
Depending on the specified connection type, the example can instantiate |
| 33 |
a \l QModbusRtuSerialClient (for serial communication), or a |
| 34 |
\l QModbusTcpClient (for TCP-based communication). |
| 35 |
|
| 36 |
\snippet modbus/client/mainwindow.cpp create_client_0 |
| 37 |
|
| 38 |
Once the client is created, use the |
| 39 |
\l {QModbusClient::}{setConnectionParameter()} method to specify the |
| 40 |
connection parameters. The parameters vary depending on the communication |
| 41 |
type: |
| 42 |
|
| 43 |
\snippet modbus/client/mainwindow.cpp create_client_1 |
| 44 |
|
| 45 |
After the client is created and all the parameters are specified, use |
| 46 |
\l {QModbusClient::connectDevice()} to connect to Modbus network. |
| 47 |
|
| 48 |
\section1 Reading Data |
| 49 |
|
| 50 |
To read data from Modbus server, the client needs to specify a |
| 51 |
server address and the parameters of objects that it wants to read: |
| 52 |
\list |
| 53 |
\li \l {QModbusDataUnit::}{RegisterType} |
| 54 |
\li \l {QModbusDataUnit::startAddress}{start address} |
| 55 |
\li \l {QModbusDataUnit::valueCount}{number of entries to read} |
| 56 |
\endlist |
| 57 |
|
| 58 |
The object parameters are represented by the \l QModbusDataUnit class: |
| 59 |
|
| 60 |
\snippet modbus/client/mainwindow.cpp read_data_0 |
| 61 |
|
| 62 |
Once the parameters are collected, the |
| 63 |
\l {QModbusClient::}{sendReadRequest()} method is used to send the actual |
| 64 |
request. The method returns a \l QModbusReply which should be processed |
| 65 |
in an asynchronous way, so the \l QModbusReply::finished() signal is used |
| 66 |
to check when the reply is ready. |
| 67 |
|
| 68 |
\snippet modbus/client/mainwindow.cpp read_data_1 |
| 69 |
|
| 70 |
Once the \l QModbusReply::finished() signal is received, the reply object |
| 71 |
can be used to get the data or to check for read errors: |
| 72 |
|
| 73 |
\snippet modbus/client/mainwindow.cpp read_data_2 |
| 74 |
|
| 75 |
\section1 Writing Data |
| 76 |
|
| 77 |
To write the data to the Modbus server, the client needs to specify the |
| 78 |
server address, and the parameters of objects that it wants to write. |
| 79 |
As with reading the data, the \l QModbusDataUnit class is used to represent |
| 80 |
the information about the data to be written. This time the data also |
| 81 |
includes the desired \l {QModbusDataUnit::}{values}. |
| 82 |
The \l {QModbusClient::}{sendWriteRequest()} method is used to write the |
| 83 |
desired data: |
| 84 |
|
| 85 |
\snippet modbus/client/mainwindow.cpp write_data_0 |
| 86 |
|
| 87 |
Like with reading the data, the returned \l QModbusReply object is used |
| 88 |
to check for write errors. |
| 89 |
|
| 90 |
\include examples-run.qdocinc |
| 91 |
*/ |