Debian Codegraph @

pymeasure/instruments/kepco/kepcobop.py

raw
1 #
2 # This file is part of the PyMeasure package.
3 #
4 # Copyright (c) 2013-2024 PyMeasure Developers
5 #
6 # Permission is hereby granted, free of charge, to any person obtaining a copy
7 # of this software and associated documentation files (the "Software"), to deal
8 # in the Software without restriction, including without limitation the rights
9 # to use, copy, modify, merge, publish, distribute, sublicense, and/or sell
10 # copies of the Software, and to permit persons to whom the Software is
11 # furnished to do so, subject to the following conditions:
12 #
13 # The above copyright notice and this permission notice shall be included in
14 # all copies or substantial portions of the Software.
15 #
16 # THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
17 # IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY,
18 # FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE
19 # AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER
20 # LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM,
21 # OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN
22 # THE SOFTWARE.
23 #
24
25 # List of Kepco BOP's (Vmax,Imax) [single channel output]
26 # 100 W:
27 # 5-20
28 # 20-5
29 # 50-2
30 # 100-1
31
32 # 200 W:
33 # 5-30
34 # 20-10
35 # 36-6
36 # 50-4
37 # 72-3
38 # 100-2
39 # 200-1
40
41 # 400 W:
42 # 20-20
43 # 36-12
44 # 50-8
45 # 72-6
46 # 100-4
47
48 from enum import IntFlag
49 from pymeasure.instruments import Instrument, SCPIMixin
50 from pymeasure.instruments.validators import strict_discrete_set, \
51 truncated_range
52
53 OPERATING_MODES = ['VOLT', 'CURR']
54
55
56 class TestErrorCode(IntFlag):
57 QUARTER_SCALE_VOLTAGE_READBACK = 512
58 QUARTER_SCALE_VOLTAGE = 256
59 MIN_VOLTAGE_OUTPUT = 128
60 MAX_VOLTAGE_OUTPUT = 64
61 LOOP_BACK_TEST = 32
62 DIGITAL_POT = 16
63 OPTICAL_BUFFER = 8
64 FLASH = 4
65 RAM = 2
66 ROM = 1
67 OK = 0
68
69
70 class KepcoBOP3612(SCPIMixin, Instrument):
71 """
72 Represents the Kepco BOP 36-12 (M or D) 400 W bipolar power supply
73 fitted with BIT 4886 digital interface card (minimal implementation)
74 and provides a high-level interface for interacting with the instrument.
75 """
76 _Vmax = 36
77 _Imax = 12
78
79 def __init__(self, adapter, name="Kepco BOP 36-12 Bipolar Power Supply",
80 **kwargs):
81 super().__init__(
82 adapter=adapter,
83 name=name,
84 read_termination="\n",
85 write_termination="\n",
86 **kwargs
87 )
88
89 output_enabled = Instrument.control(
90 "OUTPut?",
91 "OUTPut %d",
92 """
93 Control whether the source is enabled, takes values True or False (bool)
94 """,
95 validator=strict_discrete_set,
96 values={True: 1, False: 0},
97 map_values=True,
98 )
99
100 def beep(self):
101 """Cause the unit to emit a brief audible tone."""
102 self.write("SYSTem:BEEP")
103
104 confidence_test = Instrument.measurement(
105 "*TST?",
106 """
107 Get error code after performing interface self-test procedure.
108
109 Returns 0 if all tests passed, otherwise corresponding error code
110 as detailed in manual.
111 """,
112 get_process=lambda v: TestErrorCode(v),
113 )
114
115 bop_test = Instrument.measurement(
116 "DIAG:TST?",
117 """
118 Get error code after performing full power supply self-test.
119
120 Returns 0 if all tests passed, otherwise corresponding error code
121 as detailed in manual.
122 Caution: Output will switch on and swing to maximum values.
123 Disconnect any load before testing.
124 """,
125 get_process=lambda v: TestErrorCode(v),
126 )
127
128 def wait_to_continue(self):
129 """ Cause the power supply to wait until all previously issued
130 commands and queries are complete before executing subsequent
131 commands or queries. """
132 self.write("*WAI")
133
134 voltage = Instrument.measurement(
135 "MEASure:VOLTage?",
136 """
137 Measure voltage present across the output terminals in Volts.
138 """,
139 cast=float
140 )
141
142 current = Instrument.measurement(
143 "MEASure:CURRent?",
144 """
145 Measure current through the output terminals in Amps.
146 """,
147 cast=float
148 )
149
150 operating_mode = Instrument.control(
151 "FUNCtion:MODE?", "FUNCtion:MODE %s",
152 """
153 Control the operating mode of the BOP.
154
155 As a command, a string, VOLT or CURR, is sent.
156 As a query, a 0 or 1 is returned, corresponding to VOLT or CURR respectively.
157 This is mapped to corresponding string.
158 """,
159 validator=strict_discrete_set,
160 values=OPERATING_MODES,
161 get_process=lambda x: OPERATING_MODES[int(x)]
162 )
163
164 current_setpoint = Instrument.control(
165 "CURRent?", "CURRent %g",
166 """
167 Control the output current setpoint.
168
169 Functionality depends on the operating mode.
170 If power supply in current mode, this sets the output current setpoint.
171 The current achieved depends on the voltage compliance and load conditions
172 (see: `current`).
173 If power supply in voltage mode, this sets the compliance current
174 for the corresponding voltage set point.
175 Query returns programmed value, meaning of which is dependent on
176 power supply operating context (see: `operating_mode`).
177
178 Output must be enabled separately (see: `output_enabled`)
179 """,
180 validator=truncated_range,
181 values=[-1*_Imax, _Imax]
182 )
183
184 voltage_setpoint = Instrument.control(
185 "VOLTage?", "VOLTage %g",
186 """
187 Control the output voltage setpoint.
188
189 Functionality depends on the operating mode.
190 If power supply in voltage mode, this sets the output voltage setpoint.
191 The voltage achieved depends on the current compliance and load conditions
192 (see: `voltage`).
193 If power supply in current mode, this sets the compliance voltage
194 for the corresponding current set point.
195 Query returns programmed value, meaning of which is dependent on
196 power supply operating context (see: `operating_mode`).
197
198 Output must be enabled separately (see: `output_enabled`)
199 """,