1 #
2 # This file is part of the PyMeasure package.
3 #
4 # Copyright (c) 2013-2024 PyMeasure Developers
5 #
6 # Permission is hereby granted, free of charge, to any person obtaining a copy
7 # of this software and associated documentation files (the "Software"), to deal
8 # in the Software without restriction, including without limitation the rights
9 # to use, copy, modify, merge, publish, distribute, sublicense, and/or sell
10 # copies of the Software, and to permit persons to whom the Software is
11 # furnished to do so, subject to the following conditions:
12 #
13 # The above copyright notice and this permission notice shall be included in
14 # all copies or substantial portions of the Software.
15 #
16 # THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
17 # IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY,
18 # FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE
19 # AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER
20 # LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM,
21 # OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN
22 # THE SOFTWARE.
23 #
24
25 import logging
26 from math import log10
27 from enum import Enum, IntFlag
28 from datetime import datetime
29
30 import numpy as np
31
32 from pymeasure.instruments import Instrument
33 from pymeasure.instruments.validators import strict_discrete_set, truncated_discrete_set, \
34 joined_validators, strict_range
35
36 log = logging.getLogger(__name__)
37 log.addHandler(logging.NullHandler())
38
39
40 try:
41 from enum import StrEnum
42 except ImportError:
43 class StrEnum(str, Enum):
44 """Until StrEnum is broadly available / pymeasure relies on python <=
45 3.10.x."""
46
47 def __str__(self):
48 return self.value
49
50
51 class WindowType(StrEnum):
52 """Enumeration to represent the different window mode for FFT functions"""
53
54 #: Flattop provides optimum amplitude accuracy
55 Flattop = "FLATTOP"
56
57 #: Hanning provides an amplitude accuracy/frequency resolution compromise
58 Hanning = "HANNING"
59
60 #: Uniform provides equal weighting of the time record for measuring transients.
61 Uniform = "UNIFORM"
62
63
64 class StatusRegister(IntFlag):
65 """Enumeration to represent the Status Register."""
66
67 #: Request Service
68 RQS = 64
69
70 #: Set when error present
71 ERROR_PRESENT = 32
72
73 #: Any command is completed
74 COMMAND_COMPLETE = 16
75
76 #: Unused but sometimes set
77 NA = 8
78
79 #: Set when any sweep is completed
80 END_OF_SWEEP = 4
81
82 #: Set when display message appears
83 MESSAGE = 2
84
85 #: Trigger is activated
86 TRIGGER = 1
87
88 #: No Interrupts can interrupt the program sequence
89 NONE = 0
90
91
92 class Trace(StrEnum):
93 """Enumeration to represent either Trace A or Trace B."""
94
95 #: Trace A
96 A = "TRA"
97
98 #: Trace B
99 B = "TRB"
100
101
102 class SweepCoupleMode(StrEnum):
103 """Enumeration."""
104
105 #: Stimulus Response
106 SpectrumAnalyzer = "SA"
107
108 #: Spectrum Analyeze
109 StimulusResponse = "SR"
110
111
112 class SweepOut(StrEnum):
113 """Enumeration."""
114
115 #: 0 - 10V Ramp
116 Ramp = "RAMP"
117
118 #: DC Ramp 0.5V / GHz
119 Fav = "FAV"
120
121
122 class MixerMode(StrEnum):
123 """Enumeration to represent the Mixer Mode of the HP8561B."""
124
125 #: Mixer Mode Internal
126 Internal = "INT"
127
128 #: Mixer Mode External
129 External = "EXT"
130
131
132 class SourceLevelingControlMode(StrEnum):
133 """Enumeration to represent the Source Leveling Control Mode of the
134 HP8560A."""
135
136 #: Source Leveling Control Mode Internal
137 Internal = "INT"
138
139 #: Source Leveling Control Mode External
140 External = "EXT"
141
142
143 class PeakSearchMode(StrEnum):
144 """Enumeration to represent the Marker Peak Search Mode."""
145
146 #: Place marker to the highest value on the trace
147 High = "HI"
148
149 #: Place marker to the next highest value on the trace
150 NextHigh = "NH"
151
152 #: Place marker to the next peak to the right
153 NextRight = "NR"
154
155 #: Place marker to the next peak to the left
156 NextLeft = "NL"
157
158
159 class CouplingMode(StrEnum):
160 """Enumeration to represent the Coupling Mode."""
161
162 #: AC
163 AC = "AC"
164
165 #: DC
166 DC = "DC"
167
168
169 class DemodulationMode(StrEnum):
170 """Enumeration to represent the Demodulation Mode."""
171
172 #: Amplitude Modulation
173 Amplitude = "AM"
174
175 #: Frequency Modulation
176 Frequency = "FM"
177
178 #: Demodulation Off
179 Off = "OFF"
180
181
182 class TriggerMode(StrEnum):
183 """Enumeration to represent the different trigger modes"""
184
185 #: External Mode
186 External = "EXT"
187
188 #: Free Running
189 Free = "FREE"
190
191 #: Line Mode
192 Line = "LINE"
193
194 #: Video Mode
195 Video = "VID"
196
197
198 class TraceDataFormat(StrEnum):
199 """Enumeration to represent the different trace data formats."""
200
201 #: A-Block format
202 A_BLOCK = "A"
203
204 #: Binary format
205 BINARY = "B"
206
207 #: I-Block format
208 I_BLOCK = "I"
209
210 #: ASCII format
211 ASCII = "M"
212
213 #: Real numbers format like are in Hz, volts, watts, dBm, dBmV, dBuV, dBV, or seconds.
214 REAL = "P"
215
216
217 class FrequencyReference(StrEnum):
218 """Enumeration to represent the frequency reference source."""
219
220 #: Internal Frequency Reference
221 Internal = "INT"
222
223 #: External Frequency Standard
224 External = "EXT"
225
226
227 class DetectionModes(StrEnum):
228 """Enumeration to represent the Detection Modes."""
229
230 #: Negative Peak Detection
231 NegativePeak = "NEG"
232
233 #: Normal Peak Detection
234 Normal = "NRM"
235
236 #: Positive Peak Detection
237 PositivePeak = "POS"
238
239 #: Sampl Mode Detection
240 Sample = "SMP"
241
242
243 class AmplitudeUnits(StrEnum):
244 """Enumeration to represent the amplitude units."""
245
246 #: DB over millit Watt
247 DBM = "DBM"
248
249 #: DB over milli Volt
250 DBMV = "DBMV"
251
252 #: DB over micro Volt
253 DBUV = "DBUV"
254
255 #: Volts
256 V = "V"
257
258 #: Watt
259 W = "W"
260
261 #: Automatic Unit (Usually derives to 'DBM')
262 AUTO = "AUTO"
263
264 #: Manual Mode
265 MANUAL = "MAN"
266
267
268 class ErrorCode:
269 """
270 Class to decode error codes from the spectrum analyzer.
271 """
272 __error_code_list = {
273 0: ("NO ERR", "No Error at all"),
274 100: ("PWRON", "Power-on state is invalid; default state is loaded"),
275 101: ("NO STATE", "State to be RECALLed not valid or not SAVEd"),
276 106: ("ABORTED!", "Current operation is aborted; HP-IB parser reset"),
277 107: ("HELLO ??", "No HP-IB listener is present"),
278 108: ("TIME OUT", "Analyzer timed out when acting as controller"),
279 109: ("CtrlFail", "Analyzer unable to take control of the bus"),
280 110: ("NOT CTRL", "Analyzer is not system controller"),
281 111: ("# ARGMTS", "Command does not have enough arguments"),
282 112: ("??CMD??", "Unrecognized command"),
283 113: ("FREQ NQ!", "Command cannot have frequency units"),
284 114: ("TIME NOG!", "Command cannot have time units"),
285 115: ("AMPL NO!", "Command cannot have amplitude units"),
286 116: ("PUNITS??", "Unrecognizable units"),
287 117: ("NOP NUM", "Command cannot have numeric units"),
288 118: ("NOP EP", "Enable parameter cannot be used"),
289 119: ("NOP UPDN", "UP/DN are not valid arguments for command"),
290 120: ("NOP ONOF", "ON/OFF are not valid arguments for command"),
291 121: ("NOP ARG", "AUTO/MAN are not valid arguments for command"),
292 122: ("NOP TRC", "Trace registers are not valid for command"),
293 123: ("NOP ABLK", "A-block format not valid here"),
294 124: ("NOP IBLK", "I-block format not valid here"),
295 125: ("NOP STRNG", "Strings are not valid for this command"),
296 126: ("NO ?", "This command cannot be queried"),
297 127: ("BAD DTMD", "Not a valid peak detector mode"),
298 128: ("PK WHAT?", "Not a valid peak search parameter"),
299 129: ("PRE TERM", "Premature A-block termination"),
300 130: ("BAD TDF", "Arguments are only for TDF command"),
301 131: ("?? AM/FM", "AM/FM are not valid arguments for this command"),
302 132: ("!FAV/RMP", "FAV/RAMP are not valid arguments for this command"),
303 133: ("!INT/EXT", "INT/EXT are not valid arguments for this command"),
304 134: ("??? ZERO", "ZERO is not a valid argument for this command"),
305 135: ("??? CURR", "CURR is not a valid argument for this command"),
306 136: ("??? FULL", "FULL is not a valid argument for this command"),
307 137: ("??? LAST", "LAST is not a valid argument for this command"),
308 138: ("!GRT/DSP", "GRT/DSP are not valid arguments for this command"),
309 139: ("PLOTONLY", "Argument can only be used with PLOT command"),
310 140: ("?? PWRON", "PWRON is not a valid argument for this command"),
311 141: ("BAD ARG", "Argument can only be used with FDIAG command"),
312 142: ("BAD ARG", "Query expected for FDIAG command"),
313 143: ("NO PRESL", "No preselector hardware to use command with (HP 8562B)"),
314 200: ("SYSTEM", "Hardware/firmware interaction; check other errors"),
315 201: ("SYSTEM", "Hardware/firmware interaction; check other errors"),
316 250: ("OUTOF RG", "ADC input is outside of ADC range"),
317 251: ("NO IRQ", "Microprocessor not receiving interrupt from ADC"),
318 300: ("YTO UNLK", "YTO (1ST LO) phase-locked loop (PLL) is unlocked"),
319 301: ("YTO UNLK", "YTO PLL is unlocked"),
320 302: ("OFF UNLK", "Offset Roller Oscillator PLL is unlocked"),
321 303: ("XFR UNLK", "Transfer Roller Oscillator PLL is unlocked"),
322 304: ("ROL UNLK", "Main Roller Oscillator PLL is unlocked"),
323 305: ("FREQ ACC", "Frequency accuracy error"),
324 306: ("FREQ ACC", "Frequency accuracy error"),
325 307: ("FREQ ACC", "Frequency accuracy error"),
326 308: ("FREQ ACC", "Frequency accuracy error"),
327 309: ("FREQ ACC", "Frequency accuracy error"),
328 310: ("FREQ ACC", "Frequency accuracy error"),
329 311: ("FREQ ACC", "Frequency accuracy error"),
330 312: ("FREQ ACC", "Frequency accuracy error"),
331 313: ("FREQ ACC", "Frequency accuracy error"),
332 314: ("FREQ ACC", "Frequency accuracy error"),
333 315: ("FREQ ACC", "Frequency accuracy error"),
334 316: ("FREQ ACC", "Frequency accuracy error"),
335 317: ("FREQ ACC", "Frequency accuracy error"),
336 318: ("FREQ ACC", "Frequency accuracy error"),
337 319: ("FREQ ACC", "Frequency accuracy error"),
338 320: ("FREQ ACC", "Frequency accuracy error"),
339 321: ("FREQ ACC", "Frequency accuracy error"),
340 322: ("FREQ ACC", "Frequency accuracy error"),
341 323: ("FREQ ACC", "Frequency accuracy error"),
342 324: ("FREQ ACC", "Frequency accuracy error"),
343 325: ("FREQ ACC", "Frequency accuracy error"),
344 326: ("FREQ ACC", "Frequency accuracy error"),
345 327: ("OFF UNLK", "Offset Roller Oscillator PLL is unlocked"),
346 328: ("FREQ ACC", "Frequency accuracy error"),
347 329: ("FREQ ACC", "Frequency accuracy error"),
348 331: ("FREQ ACC", "Frequency accuracy error"),
349 333: ("600 UNLK", "600 MHz Reference Oscillator PLL is unlocked"),
350 334: ("LO AMPL", "YTO (ist LO) unleveled"),
351 400: ("AMPL 100", "Unable to adjust amplitude of 100 Hz resolution bandwidth"),
352 401: ("AMPL 300", "Unable to adjust amplitude of 300 Hz resolution bandwidth"),
353 402: ("AMPL 1K", "Unable to adjust amplitude of 1 kHz resolution bandwidth"),
354 403: ("AMPL 3K", "Unable to adjust amplitude of 3 kHz resolution bandwidth"),
355 404: ("AMPL 10K", "Unable to adjust amplitude of 10 kHz resolution bandwidth"),
356 405: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth"),
357 406: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth"),
358 407: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth"),
359 408: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth"),
360 409: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth"),
361 410: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth"),
362 411: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth"),
363 412: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth"),
364 413: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth"),
365 414: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth"),
366 415: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth"),
367 416: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth"),
368 417: ("RBW 3K", "Unable to adjust 3 kHz resolution bandwidth"),
369 418: ("RBW 3K", "Unable to adjust 3 kHz resolution bandwidth"),
370 419: ("RBW 3K", "Unable to adjust 3 kHz resolution bandwidth"),
371 420: ("RBW 3K", "Unable to adjust 3 kHz resolution bandwidth"),
372 421: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth"),
373 422: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth"),
374 423: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth"),
375 424: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth"),
376 425: ("RBW 3K", "Unable to adjust 3 kHz resolution bandwidth"),
377 426: ("RBW 3K", "Unable to adjust 3 kHz resolution bandwidth"),
378 427: ("RBW 3K", "Unable to adjust 3 kHz resolution bandwidth"),
379 428: ("RBW 3K", "Unable to adjust 3 kHz resolution bandwidth"),
380 429: ("RBW 100", "Unable to adjust 100 Hz resolution bandwidth"),
381 430: ("RBW 300", "Unable to adjust 300 Hz resolution bandwidth"),
382 431: ("RBW 1K", "Unable to adjust 1 kHz resolution bandwidth"),
383 432: ("RBW 3K", "Unable to adjust 3 kHz resolution bandwidth"),
384 433: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth"),
385 434: ("RBW 300", "Unable to adjust 300 Hz resolution bandwidth"),
386 435: ("RBW 301", "Unable to adjust 300 Hz resolution bandwidth"),
387 436: ("RBW 302", "Unable to adjust 300 Hz resolution bandwidth"),
388 437: ("RBW 303", "Unable to adjust 300 Hz resolution bandwidth"),
389 438: ("RBW 1K", "Unable to adjust 1 kHz resolution bandwidth"),
390 439: ("RBW 1K", "Unable to adjust 1 kHz resolution bandwidth"),
391 440: ("RBW 1K", "Unable to adjust 1 kHz resolution bandwidth"),
392 441: ("RBW 1K", "Unable to adjust 1 kHz resolution bandwidth"),
393 442: ("RBW 3K", "Unable to adjust 3 kHz resolution bandwidth"),
394 443: ("RBW 3K", "Unable to adjust 3 kHz resolution bandwidth"),
395 444: ("RBW 3K", "Unable to adjust 3 kHz resolution bandwidth"),
396 445: ("RBW 3K", "Unable to adjust 3 kHz resolution bandwidth"),
397 446: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth"),
398 447: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth"),
399 448: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth"),
400 449: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth"),
401 450: ("IF SYSTM", "IF hardware failure Check other error messages"),
402 451: ("IF SYSTM", "IF hardware failure Check other error messages"),
403 452: ("IF SYSTM", "IF hardware failure Check other error messages"),
404 454: ("FREQ ACC", "Unable to adjust step gain amplifiers"),
405 455: ("FREQ ACC", "Unable to adjust step gain amplifiers"),
406 456: ("FREQ ACC", "Unable to adjust step gain amplifiers"),
407 457: ("FREQ ACC", "Unable to adjust step gain amplifiers"),
408 458: ("FREQ ACC", "Unable to adjust step gain amplifiers"),
409 459: ("FREQ ACC", "Unable to adjust step gain amplifiers"),
410 460: ("FREQ ACC", "Unable to adjust step gain amplifiers"),
411 461: ("FREQ ACC", "Unable to adjust step gain amplifiers"),
412 462: ("FREQ ACC", "Unable to adjust step gain amplifiers"),
413 463: ("FREQ ACC", "Unable to adjust step gain amplifiers"),
414 464: ("FREQ ACC", "Unable to adjust step gain amplifiers"),
415 465: ("FREQ ACC", "Unable to adjust step gain amplifiers"),
416 466: ("LIN AMPL", "Unable to adjust linear amplitude scale"),
417 467: ("LOG AMPL", "Unable to adjust log amplitude scale"),
418 468: ("LOG AMPL", "Unable to adjust log amplitude scale"),
419 469: ("LOG AMPL", "Unable to adjust log amplitude scale"),
420 470: ("LOG AMPL", "Unable to adjust log amplitude scale"),
421 471: ("RBW 30K", "Unable to adjust 30 kHz resolution bandwidth"),
422 472: ("RBW 100K", "Unable to adjust 100 kHz resolution bandwidth"),
423 473: ("RBW 300K", "Unable to adjust 300 kHz resolution bandwidth"),
424 474: ("RBW 1M", "Unable to adjust 1 MHz resolution bandwidth"),
425 475: ("RBW 30K", "Unable to adjust 30 kHz resolution bandwidth"),
426 476: ("RBW 100K", "Unable to adjust 30 kHz resolution bandwidth"),
427 477: ("RBW 300K", "Unable to adjust 300 kHz resolution bandwidth"),
428 478: ("RBW 1M", "Unable to adjust 1 MHz resolution bandwidth"),
429 483: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth"),
430 484: ("RBW 3K", "Unable to adjust 3 kHz resolution bandwidth"),
431 485: ("RBW 1K", "Unable to adjust 1 kHz resolution bandwidth"),
432 486: ("RBW 300", "Unable to adjust 300 Hz resolution bandwidth"),
433 487: ("RBW 100", "Unable to adjust 100 Hz resolution bandwidth"),
434 488: ("RBW 100", "Unable to adjust 100 Hz resolution bandwidth"),
435 489: ("RBW 101", "Unable to adjust 100 Hz resolution bandwidth"),
436 490: ("RBW 102", "Unable to adjust 100 Hz resolution bandwidth"),
437 491: ("RBW 103", "Unable to adjust 100 Hz resolution bandwidth"),
438 492: ("RBW 300", "Unable to adjust 300 Hz resolution bandwidth"),
439 493: ("RBW 1K", "Unable to adjust 1 kHz resolution bandwidth"),
440 494: ("RBW 3K", "Unable to adjust 3 kHz resolution bandwidth"),
441 495: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth"),
442 496: ("RBW 100", "Unable to adjust 100 Hz resolution bandwidth"),
443 497: ("RBW 100", "Unable to adjust 100 Hz resolution bandwidth"),
444 498: ("RBW 100", "Unable to adjust 100 Hz resolution bandwidth"),
445 499: ("CAL UNLK", "A16 IF Adjustment Cal Oscillator is unlocked"),
446 500: ("AMPL 30K", "Unable to adjust amplitude of 30 kHz resolution bandwidth"),
447 501: ("AMPL 1M", "Unable to adjust amplitude of 100 kHz resolution bandwidth"),
448 502: ("AMPL 3M", "Unable to adjust amplitude of 300 kHz resolution bandwidth"),
449 503: ("AMPL 1M", "Unable to adjust amplitude of 1 MHz resolution bandwidth"),
450 504: ("AMPL 30K", "Unable to adjust amplitude of 30 kHz resolution bandwidth"),
451 505: ("AMPL 1M", "Unabie to adjust amplitude of 100 kHz resolution bandwidth"),
452 506: ("AMPL 3M", "Unable to adjust amplitude of 300 kHz resolution bandwidth"),
453 507: ("AMPL 1M", "Unable to adjust amplitude of 1 MHz resolution bandwidth"),
454 508: ("AMPL 30K", "Unable to adjust amplitude of 30 kHz resolution bandwidth"),
455 509: ("AMPL 1M", "Unable to adjust amplitude of 100 kHz resolution bandwidth"),
456 510: ("AMPL 3M", "Unable to adjust amplitude of 300 kHz resolution bandwidth"),
457 511: ("AMPL 1M", "Unable to adjust amplitude of 1 MHz resolution bandwidth"),
458 512: ("RBW 100", "Unable to adjust 100 Hz resolution bandwidth"),
459 513: ("RBW 300", "Unable to adjust 300 Hz resolution bandwidth"),
460 514: ("RBW 1K", "Unable to adjust 1 kHz resolution bandwidth"),
461 515: ("RBW 3K", "Unable to adjust 3 kHz resolution bandwidth"),
462 516: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth"),
463 517: ("RBW 100", "Unable to adjust 100 Hz resolution bandwidth"),
464 518: ("RBW 300", "Unable to adjust 300 Hz resolution bandwidth"),
465 519: ("RBW 1K", "Unable to adjust 1 kHz resolution bandwidth"),
466 520: ("RBW 3K", "Unable to adjust 3 kHz resolution bandwidth"),
467 521: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth"),
468 522: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth SYM POLE 1"),
469 523: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth SYM POLE 2"),
470 524: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth SYM POLE 3"),
471 525: ("RBW 10K", "Unable to adjust 10 kHz resolution bandwidth SYM POLE 4"),
472 526: ("RBW <300", "Unable to adjust <300 Hz resolution bandwidths"),
473 527: ("RBW <301", "Step gain correction failed for <300 Hz resolution bandwidth"),
474 528: ("RBW <302", "Unable to adjust <300 Hz resolution bandwidths"),
475 529: ("RBW <303", "Unable to adjust <300 Hz resolution bandwidths"),
476 530: ("RBW <304", "Unable to adjust <300 Hz resolution bandwidths"),
477 531: (
478 "RBW <305", "Unable to adjust gain versus frequency for resoultion bandwidths <300 Hz"),
479 532: ("RBW <306", "Absolute gain data for resolution bandwidths <300 Hz not acceptable"),
480 533: ("RBW <307", "Unable to adjust <300 Hz resolution bandwidths"),
481 534: ("RBW <308", "Unable to adjust frequency accuracy for resolution bandwidths <100 Hz"),
482 535: ("RBW <309", "Unable to adjust <300 Hz resolution bandwidths"),
483 536: ("RBW <310", "Unable to adjust <300 Hz resolution bandwidths"),
484 537: ("RBW <311", "Unable to adjust <300 Hz resolution bandwidths"),
485 538: ("RBW <312", "Unable to adjust <300 Hz resolution bandwidths"),
486 539: ("RBW <313", "Unable to adjust <300 Hz resolution bandwidths"),
487 540: ("RBW <314", "Unable to adjust <300 Hz resolution bandwidths"),
488 551: ("AMPL", "Unable to adjust step gain amplifiers"),
489 552: ("LOG AMPL", "Unable to adjust amplitude of log scale"),
490 553: ("LOG AMPL", "Unable to adjust amplitude of log scale"),
491 554: ("LOG AMPL", "Unable to adjust amplitude of log scale"),
492 555: ("LOG AMPL", "Unable to adjust amplitude of log scale"),
493 556: ("LOG AMPL", "Unable to adjust amplitude of log scale"),
494 557: ("LOG AMPL", "Unable to adjust amplitude of log scale"),
495 558: ("LOG AMPL", "Unable to adjust amplitude of log scale"),
496 559: ("LOG AMPL", "Unable to adjust amplitude of log scale"),
497 560: ("LOG AMPL", "Unable to adjust amplitude of log scale"),
498 561: ("LOG AMPL", "Unable to adjust amplitude of log scale"),
499 562: ("LOG AMPL", "Unable to adjust amplitude of log scale"),
500 563: ("LOG AMPL", "Unable to adjust amplitude of log scale"),
501 564: ("LOG AMPL", "Unable to adjust amplitude of log scale"),
502 565: ("LOG AMPL", "Unable to adjust amplitude of log scale"),
503 566: ("LOG AMPL", "Unable to adjust amplitude of log scale"),
504 567: ("LOG AMPL", "Unable to adjust amplitude of log scale"),
505 568: ("LOG AMPL", "Unable to adjust amplitude of log scale"),
506 569: ("LOG AMPL", "Unable to adjust amplitude of log scale"),
507 570: ("LOG AMPL", "Unable to adjust amplitude of log scale"),
508 571: ("AMPL", "Unable to adjust step gain amplifiers"),
509 572: ("AMPL 1M", "Unable to adjust amplitude of 1 MHz resolution bandwidth"),
510 573: ("LOG AMPL", "Unable to adjust amplitude in log scale"),
511 574: ("LOG AMPL", "Unable to adjust amplitude in log scale"),
512 575: ("LOG AMPL", "Unable to adjust amplitude in log scale"),
513 576: ("LOG AMPL", "Unable to adjust amplitude in log scale"),
514 577: ("LOG AMPL", "Unable to adjust amplitude in log scale"),
515 581: ("AMPL", "Unable to adjust 100 kHz and <10 kHz resolution bandwidths"),
516 582: ("AMPL", "Unable to adjust 100 kHz and <10 kHz resolution bandwidths"),
517 583: ("RBW 30K", "Unable to adjust 30 kHz resolution bandwidth"),
518 584: ("RBW 100K", "Unable to adjust 100 kHz resolution bandwidth"),
519 585: ("RBW 300K", "Unable to adjust 300 kHz resolution bandwidth"),
520 586: ("RBW 1M", "Unable to adjust 1 MHz resolution bandwidth"),
521 587: ("RBW 30K", "Unable to adjust 30 kHz resolution bandwidth"),
522 588: ("RBW 300K", "Unable to adjust 100 kHz resolution bandwidth"),
523 589: ("RBW 300K", "Unable to adjust 300 kHz resolution bandwidth"),
524 590: ("RBW 1M", "Unable to adjust 1 MHz resolution bandwidth"),
525 591: ("LOG AMPL", "Unable to adjust amplitude in log scale"),
526 592: ("LOG AMPL", "Unable to adjust amplitude in log scale"),
527 600: ("SYSTEM", "Hardware/firmware interaction; check other errors"),
528 601: ("SYSTEM", "Hardware/firmware interaction; check other errors"),
529 650: ("OUTOF RG", "ADC input is outside of the ADC range"),
530 651: ("NO IRQ", "Microprocessor is not receiving interrupt from ADC"),
531 700: ("EEROM", "Checksum error of EEROM A2U501"),
532 701: ("AMPL CAL", "Checksum error of frequency response correction data"),
533 702: ("ELAP TIM", "Checksum error of elapsed time data"),
534 703: ("AMPL CAL", "Checksum error of frequency response correction data"),
535 704: ("PRESELCT", "Checksum error of customer preselector peak data"),
536 705: ("ROM U306", "Checksum error of program ROM A2U306"),
537 706: ("ROM U307", "Checksum error of program ROM A2U307"),
538 707: ("ROM U308", "Checksum error of program ROM A2U308"),
539 708: ("ROM U309", "Checksum error of program ROM A2U309"),
540 709: ("ROM U310", "Checksum error of program ROM A2U310"),
541 710: ("ROM U311", "Checksum error of program ROM A2U311"),
542 711: ("RAM U303", "Checksum error of system RAM A2U303"),
543 712: ("RAM U302", "Checksum error of system RAM A2U302"),
544 713: ("RAM U301", "Checksum error of system RAM A2U301"),
545 714: ("RAM U300", "Checksum error of system RAM A2U300"),
546 715: ("RAM U305", "Checksum error of system RAM A2U305"),
547 716: ("RAM U304", "Checksum error of system RAM A2U304"),
548 717: ("BAD uP!!", "Microprocessor not fully operational"),
549 718: ("BATTERY?", "Nonvolatile RAM not working; check battery"),
550 750: ("SYSTEM", "Hardware/ firmware interaction; check other errors"),
551 751: ("SYSTEM", "Hardware/firmware interaction; check other errors"),
552 752: ("SYSTEM", "Hardware/firmware interaction; check other errors"),
553 753: ("SYSTEM", "Hardware/firmware interaction; check other errors"),
554 754: ("SYSTEM", "Hardware/firmware interaction; check other errors"),
555 755: ("SYSTEM", "Hardware/firmware interaction; check other errors"),
556 900: ("TG UNLVL", "Tracking generator output is unleveled"),
557 901: ("TGFrqLmt",
558 "Tracking generator output unleveled because START FREQ is set "
559 "below tracking generator frequency limit (300 kHz)"),
560 902: ("BAD NORM",
561 "The state of the stored trace does not match the current state of the analyzer"),
562 903: ("&> DLMT", "Unnormalized trace A is off-screen with trace math or normalization on"),
563 904: (
564 "&> DLMT",
565 "Calibration trace (trace B) is off-screen with trace math or normalization on")
566 }
567
568 # integer representation of error code
569 code = 0
570
571 def __init__(self, code):
572 """Initialize an ErrorCode.
573
574 :param code: Representing an error as id or short description
575 :type code: str, int
576 """
577 if not (isinstance(code, int) or isinstance(code, str)):
578 print(type(code))
579 raise TypeError("Initialziation type for code must be integer or string")
580
581 try:
582 self.code = int(code)
583 if self.code not in self.__error_code_list.keys():
584 raise ValueError()
585
586 except (ValueError, TypeError):
587 raise ValueError("This error code doesn't exist")
588
589 (self.short, self.long) = self.__error_code_list[self.code]
590
591 def __repr__(self):
592 return "ErrorCode(\"" + self.short + " - " + self.long + "\")"
593
594 def __eq__(self, other):
595 return self.code == other.code
596
597
598 class HP856Xx(Instrument):
599 """Represents the HP856XX series spectrum analyzers.
600
601 Don't use this class directly - use their derivative classes
602
603 .. note::
604 Most command descriptions are taken from the document:
605 'HP 8560A, 8561B Operating & Programming'
606 """
607
608 def __init__(self, adapter, name="Hewlett-Packard HP856Xx", **kwargs):
609 super().__init__(
610 adapter,
611 name,
612 includeSCPI=False,
613 send_end=True,
614 **kwargs,
615 )
616
617 def adjust_all(self):
618 """Activate the local oscillator (LO) and intermediate frequency (IF)
619 alignment routines. These are the same routines that occur when is switched on.
620 Commands following 'adjust_all' are not executed until after the analyzer has finished the
621 alignment routines.
622 """
623 self.write("ADJALL")
624
625 def set_crt_adjustment_pattern(self):
626 """Activate a CRT adjustment pattern, shown in Figure 5-3. Use the
627 X POSN, Y POSN, and TRACE ALIGN adjustments (available from the rear panel) to
628 align the display. Use X POSN and Y POSN to move the display horizontally and vertically,
629 respectively. Use TRACE ALIGN to straighten a tilted display. To remove the pattern from
630 the screen, execute the :meth:`preset` command."""
631 self.write("ADJCRT")
632
633 adjust_if = Instrument.control(
634 "ADJIF?", "ADJIF %s",
635 """
636 Control the automatic IF adjustment. This function is normally
637 on. Because the IF is continuously adjusting, executing the IF alignment routine is seldom
638 necessary. When the IF adjustment is not active, an "A" appears on the left side of the
639 display.
640
641 - `"FULL"` IF adjustment is done for all IF settings.
642 - `"CURR"` IF adjustment is done only for the IF settings currently displayed.
643 - `False` turns the continuous IF adjustment off.
644 - `True` reactivates the continuous IF adjustment.
645
646 Type: :code:`bool, str`
647 """,
648 validator=strict_discrete_set,
649 map_values=True,
650 values={True: "1", False: "0", "FULL": "FULL", "CURR": "CURR"},
651 cast=str
652 )
653
654 trace_a_minus_b_enabled = Instrument.control(
655 "AMB?", "AMB %s",
656 """
657 Control subtraction of the contents of trace B from trace A.
658 It places the result, in dBm (when in log mode), in trace A. When in linear mode,
659 the result is in volts. If trace A is in clear-write or max-hold mode, this function is
660 continuous. When AMB is active, an "M" appears on the left side of the display.
661 :attr:`trace_a_minus_b_plus_dl` overrides AMB.
662
663 Type: :code:`bool`
664
665 .. warning::
666
667 The displayed amplitude of each trace element falls in one of 600 data points.
668 There are 10 points of overrange, which corresponds to one-sixth of a division
669 Kg of overrange. When adding or subtracting trace data, any results exceeding
670 this limit are clipped at the limit.
671 """,
672 validator=strict_discrete_set,
673 map_values=True,
674 values={True: "1", False: "0"},
675 cast=str
676 )
677
678 trace_a_minus_b_plus_dl_enabled = Instrument.control(
679 "AMBPL?", "AMBPL %s",
680 """
681 Control subtraction of trace B from trace A and addition to the display line,
682 and stores the result in dBm (when in log mode) in trace A. When in linear
683 mode, the result is in volts. If trace A is in clear-write or max-hold mode, this function
684 is continuous. When this function is active, an "M" appears on the left side of the display.
685
686 Type: :code:`bool`
687
688 .. warning::
689
690 The displayed amplitude of each trace element falls in one of 600 data points.
691 There are 10 points of overrange, which corresponds to one-sixth of a division
692 Kg of overrange. When adding or subtracting trace data, any results exceeding
693 this limit are clipped at the limit.
694 """,
695 validator=strict_discrete_set,
696 map_values=True,
697 values={True: "1", False: "0"},
698 cast=str
699 )
700
701 annotation_enabled = Instrument.control(
702 "ANNOT?", "ANNOT %s",
703 """
704 Set the display annotation off or on.
705
706 Type: :code:`bool`
707 """,
708 validator=strict_discrete_set,
709 map_values=True,
710 values={True: "1", False: "0"},
711 cast=str
712 )
713
714 attenuation = Instrument.control(
715 "AT?", "AT %s",
716 """
717 Control the input attenuation in decade steps from 10 to 70 db (type 'int') or set to
718 'AUTO' and 'MAN'(ual)
719
720 Type: :code:`str`, :code:`int`
721
722 .. code-block:: python
723
724 instr.attenuation = 'AUTO'
725 instr.attenuation = 60
726
727 """,
728 validator=joined_validators(strict_discrete_set, truncated_discrete_set),
729 values=[["AUTO", "MAN"], np.arange(10, 80, 10)],
730 cast=int,
731 )
732
733 amplitude_unit = Instrument.control(
734 "AUNITS?", "AUNITS %s",
735 """
736 Control the amplitude unit with a selection of the following parameters: string
737 'DBM', 'DBMV', 'DBUV', 'V', 'W', 'AUTO', 'MAN' or use the enum :class:`AmplitudeUnits`
738
739 Type: :code:`str`
740
741 .. code-block:: python
742
743 instr.amplitude_unit = 'dBmV'
744 instr.amplitude_unit = AmplitudeUnits.dBmV
745
746 """,
747 validator=strict_discrete_set,
748 values=[str(e).upper() for e in AmplitudeUnits],
749 set_process=lambda v: str(v).upper()
750 )
751
752 def write(self, command, **kwargs):
753 if "{amplitude_unit}" in command:
754 command = command.format(amplitude_unit=self.amplitude_unit)
755 super().write(command, **kwargs)
756
757 def set_auto_couple(self):
758 """Set the video bandwidth, resolution bandwidth, input attenuation,
759 sweep time, and center frequency step-size to coupled mode.
760
761 These functions can be recoupled individually or all at once.
762 The spectrum analyzer chooses appropriate values for these
763 functions. The video bandwidth and resolution bandwidth are set
764 according to the coupled ratios stored under :attr:`resolution_bandwidth_to_span_ratio`
765 and :attr:`video_bandwidth_to_resolution_bandwidth`. If
766 no ratios are chosen, default ratios (1.0 and 0.011,
767 respectively) are used instead.
768 """
769 self.write("AUTOCPL")
770
771 def exchange_traces(self):
772 """Exchange the contents of trace A with those of trace B.
773
774 If the traces are in clear-write or max-hold mode, the mode is
775 changed to view. Otherwise, the traces remain in their initial
776 mode.
777 """
778 self.write("AXB")
779
780 def blank_trace(self, trace):
781 """Blank the chosen trace from the display. The current contents of the
782 trace remain in the trace but are not updated.
783
784 .. code-block:: python
785
786 instr.blank_trace('TRA')
787 instr.blank_trace(Trace.A)
788
789 :param trace: A representation of the trace, either from :class:`Trace` or
790 use 'TRA' for Trace A or 'TRB' for Trace B
791
792 :type trace: str
793 :raises TypeError: Type isn't 'string'
794 :raises ValueError: Value is 'TRA' nor 'TRB'
795 """
796 if not isinstance(trace, str):
797 raise TypeError("Should be of type string but is '%s'" % type(trace))
798
799 if trace not in [e for e in Trace]:
800 raise ValueError("Only accepts values of [%s] but was '%s'" % ([e for e in Trace],
801 trace))
802 self.write("BLANK " + trace)
803
804 def subtract_display_line_from_trace_b(self):
805 """Subtract the display line from trace B and places the result in dBm
806 (when in log mode) in trace B, which is then set to view mode.
807
808 In linear mode, the results are in volts.
809 """
810 self.write("BML")
811
812 center_frequency = Instrument.control(
813 "CF?", "CF %.11E Hz",
814 """
815 Control the center frequency in hertz and sets the spectrum analyzer to center
816 frequency / span mode.
817
818 The span remains constant; the start and stop frequencies change as
819 the center frequency changes.
820
821 Type: :code:`float`
822
823 .. code-block:: python
824
825 instr.center_frequency = 300.5e6
826 if instr.center_frequency == 200e3:
827 print("Correct frequency")
828
829 """,
830 validator=strict_range,
831 values=[0, 1],
832 dynamic=True
833 )
834
835 def clear_write_trace(self, trace):
836 """Set the chosen trace to clear-write mode. This mode sets each
837 element of the chosen trace to the bottom-screen value; then new data
838 from the detector is put in the trace with each sweep.
839
840 .. code-block:: python
841
842 instr.clear_write_trace('TRA')
843 instr.clear_write_trace(Trace.A)
844
845 :param trace: A representation of the trace, either from :class:`Trace` or
846 use 'TRA' for Trace A or 'TRB' for Trace B
847
848 :type trace: str
849 :raises TypeError: Type isn't 'string'
850 :raises ValueError: Value is 'TRA' nor 'TRB'
851 """
852 if not isinstance(trace, str):
853 raise TypeError("Should be of type string but is '%s'" % type(trace))
854
855 if trace not in [e for e in Trace]:
856 raise ValueError("Only accepts values of [%s] but was '%s'" % ([e for e in Trace],
857 trace))
858
859 self.write("CLRW " + trace)
860
861 def set_continuous_sweep(self):
862 """Set the instrument to continuous-sweep mode.
863
864 This mode enables another sweep at the completion of the current
865 sweep once the trigger conditions are met.
866 """
867 self.write("CONTS")
868
869 coupling = Instrument.control(
870 "COUPLE?", "COUPLE %s",
871 """
872 Control the input coupling of the spectrum analyzer.
873 AC coupling protects the input of the analyzer from damaging dc signals, while limiting
874 the lower frequency-range to 100 kHz (although the analyzer will tune down to 0 Hz with
875 signal attenuation).
876
877 Type: :code:`str`
878
879 Takes a representation of the coupling mode, either from :class:`CouplingMode` or
880 use 'AC' / 'DC'
881
882 .. code-block:: python
883
884 instr.coupling = 'AC'
885 instr.coupling = CouplingMode.DC
886
887 if instr.coupling == CouplingMode.DC:
888 pass
889
890 """,
891 validator=strict_discrete_set,
892 values=[e for e in CouplingMode]
893 )
894
895 demodulation_mode = Instrument.control(
896 "DEMOD?", "DEMOD %s",
897 """
898 Control the demodulation mode of the spectrum analyzer. Either AM or FM demodulation,
899 or turns the demodulation — off.
900 Place a marker on a desired signal and then set :attr:`demodulation_mode`;
901 demodulation takes place on this signal. If no marker is on, :attr:`demodulation_mode`
902 automatically places a marker at the center of the trace and demodulates the frequency at
903 that marker position. Use the volume and squelch controls to adjust the speaker and listen.
904
905 Type: :code:`str`
906
907 Takes a representation of the demodulation mode, either from :class:`DemodulationMode` or
908 use 'OFF', 'AM', 'FM'
909
910 .. code-block:: python
911
912 instr.demodulation_mode = 'AC'
913 instr.demodulation_mode = DemodulationMode.AM
914
915 if instr.demodulation_mode == DemodulationMode.FM:
916 instr.demodulation_mode = Demodulation.OFF
917
918 """,
919 validator=strict_discrete_set,
920 values=[e for e in DemodulationMode]
921 )
922
923 demodulation_agc_enabled = Instrument.control(
924 "DEMODAGC?", "DEMODAGC %s",
925 """
926 Control the demodulation automatic gain control (AGC).
927 The AGC keeps the volume of the speaker relatively constant during AM demodulation. AGC
928 is available only during AM demodulation and when the frequency span is greater than 0 Hz.
929
930 Type: :code:`bool`
931
932 .. code-block:: python
933
934 instr.demodulation_agc = True
935
936 if instr.demodulation_agc:
937 instr.demodulation_agc = False
938
939 """,
940 validator=strict_discrete_set,
941 map_values=True,
942 values={True: "1", False: "0"},
943 cast=str
944 )
945
946 demodulation_time = Instrument.control(
947 "DEMODT?", "DEMODT %.11E",
948 """
949 Control the amount of time that the sweep pauses at the marker to
950 demodulate a signal. The default value is 1 second. When the frequency span equals 0 Hz,
951 demodulation is continuous, except when between sweeps. For truly continuous demodulation,
952 set the frequency span to 0 Hz and the trigger mode to single sweep (see TM).
953 Minimum 100 ms to maximum 60 s
954
955 Type: :code:`float`
956
957 .. code-block:: python
958
959 # set the demodulation time to 1.2 seconds
960 instr.demodulation_time = 1.2
961
962 if instr.demodulation_time == 10:
963 pass
964
965 """,
966 validator=strict_range,
967 values=[100e-3, 60],
968 )
969
970 detector_mode = Instrument.control(
971 "DET?", "DET %s",
972 """
973 Control the IF detector used for acquiring measurement data.
974 This is normally a coupled function, in which the spectrum analyzer selects the
975 appropriate detector mode. Four modes are available: normal, positive, negative, and sample.
976
977 Type: :code:`str`
978
979 Takes a representation of the detector mode, either from :class:`DetectionModes` or
980 use 'NEG', 'NRM', 'POS', 'SMP'
981
982 .. code-block:: python
983
984 instr.detector_mode = DetectionModes.SMP
985 instr.detector_mode = 'NEG'
986
987 if instr.detector_mode == DetectionModes.SMP:
988 pass
989
990 """,
991 validator=strict_discrete_set,
992 values=[e for e in DetectionModes]
993 )
994
995 # now implemented as a property but due to the ability of the underlying gpib command to
996 # specify the unit, there would be an alternative implementation as a method to allow the user
997 # to modify the setting unit without manipulating it via the 'amplitude_unit' property
998 display_line = Instrument.control(
999 "DL?", "DL %g.11E {amplitude_unit}",
1000 """
1001 Control the horizontal display line for use as a visual aid or for
1002 computational purposes. The default value is 0 dBm.
1003
1004 Type: :code:`float`
1005
1006 Takes a value with the unit of :attr:`amplitude_unit`
1007
1008 .. code-block:: python
1009
1010 instr.display_line = -10
1011
1012 if instr.display_line == 0:
1013 pass
1014
1015 """
1016 )
1017
1018 display_line_enabled = Instrument.setting(
1019 "DL %s",
1020 """
1021 Set the horizontal display line for use as a visual aid either on or off.
1022
1023 .. code-block:: python
1024
1025 instr.display_line_enabled = False
1026
1027 """,
1028 map_values=True,
1029 validator=strict_discrete_set,
1030 values={True: "ON", False: "OFF"}
1031 )
1032
1033 done = Instrument.measurement(
1034 "DONE?",
1035 """
1036 Get back (e.g. return) when all commands in a command string
1037 entered before 'done' has been completed. Sending a :meth:`trigger_sweep` command
1038 before 'done' ensures that the spectrum analyzer will complete a full sweep before
1039 continuing on in a program.
1040 Depending on the timeout a timeout error from the adapter will raise before the spectrum
1041 analyzer can finish due to an extreme long sweep time
1042
1043 .. code-block:: python
1044
1045 instr.trigger_sweep()
1046
1047 # wait for a full sweep and than 'do_something'
1048 if instr.done:
1049 do_something()
1050
1051 """
1052 )
1053
1054 def check_done(self):
1055 """
1056 Return when all commands in a command string
1057 entered before :meth:'check_done' has been completed. Sending a :meth:`trigger_sweep`
1058 command before 'check_done' ensures that the spectrum analyzer will complete a full sweep
1059 before continuing on in a program. Depending on the timeout a timeout error from the
1060 adapter will raise before the spectrum analyzer can finish due to an extreme long sweep
1061 time.
1062
1063 .. code-block:: python
1064
1065 instr.trigger_sweep()
1066
1067 # wait for a full sweep and than 'do_something'
1068 instr.check_done()
1069 do_something()
1070
1071 """
1072 # no error checking because there is no possibility to return anything else than '1'
1073 self.ask("DONE?")
1074
1075 errors = Instrument.measurement(
1076 "ERR?",
1077 """
1078 Get a list of errors present (of type :class:`ErrorCode`). An empty list means there
1079 are no errors. Reading 'errors' clears all HP-IB errors. For best results, enter error
1080 data immediately after querying for errors.
1081
1082 Type: :class:`ErrorCode`
1083
1084 .. code-block:: python
1085
1086 errors = instr.errors
1087 if len(errors) > 0:
1088 print(errors[0].code)
1089
1090 for error in errors:
1091 print(error)
1092
1093 if ErrorCode(112) in errors:
1094 print("yeah")
1095
1096 Example result of this python snippet:
1097
1098 .. code-block:: python
1099
1100 112
1101 ErrorCode("??CMD?? - Unrecognized command")
1102 ErrorCode("NOP NUM - Command cannot have numeric units")
1103 yeah
1104
1105 """,
1106 cast=ErrorCode,
1107 get_process=lambda v: v if isinstance(v, list) else []
1108 )
1109
1110 elapsed_time = Instrument.measurement(
1111 "EL?",
1112 """
1113 Get the elapsed time (in hours) of analyzer operation.
1114 This value can be reset only by Hewlett-Packard.
1115
1116 Type: :code:`int`
1117
1118 .. code-block:: python
1119
1120 print(elapsed_time)
1121 1998
1122
1123 """,
1124 cast=int
1125 )
1126
1127 start_frequency = Instrument.control(
1128 "FA?", "FA %.11E Hz",
1129 """
1130 Control the start frequency and set the spectrum analyzer to start-frequency/
1131 stop-frequency mode. If the start frequency exceeds the stop frequency, the stop frequency
1132 increases to equal the start frequency plus 100 Hz. The center frequency and span change
1133 with changes in the start frequency.
1134
1135 Type: :code:`float`
1136
1137 .. code-block:: python
1138
1139 instr.start_frequency = 300.5e6
1140 if instr.start_frequency == 200e3:
1141 print("Correct frequency")
1142
1143 """,
1144 validator=strict_range,
1145 values=[0, 1],
1146 dynamic=True
1147 )
1148
1149 stop_frequency = Instrument.control(
1150 "FB?", "FB %.11E Hz",
1151 """
1152 Control the stop frequency and set the spectrum analyzer to start-frequency/
1153 stop-frequency mode. If the stop frequency is less than the start frequency, the start
1154 frequency decreases to equal the stop frequency minus 100 Hz. The center frequency and
1155 span change with changes in the stop frequency.
1156
1157 Type: :code:`float`
1158
1159 .. code-block:: python
1160
1161 instr.stop_frequency = 300.5e6
1162 if instr.stop_frequency == 200e3:
1163 print("Correct frequency")
1164
1165 """,
1166 validator=strict_range,
1167 values=[0, 1],
1168 dynamic=True
1169 )
1170
1171 sampling_frequency = Instrument.measurement(
1172 "FDIAG SMP,?",
1173 """
1174 Get the sampling oscillator frequency corresponding to the current start
1175 frequency.
1176 Diagnostic Attribute
1177
1178 Type: :code:`float`
1179 """
1180 )
1181
1182 lo_frequency = Instrument.measurement(
1183 "FDIAG LO,?",
1184 """
1185 Get the first local oscillator frequency corresponding to the current start
1186 frequency.
1187 Diagnostic Attribute
1188
1189 Type: :code:`float`
1190 """
1191 )
1192
1193 mroll_frequency = Instrument.measurement(
1194 "FDIAG MROLL,?",
1195 """
1196 Get the main roller oscillator frequency corresponding to the current start
1197 frequency, except then the resolution bandwidth is less than or equal to 100 Hz.
1198
1199 Diagnostic Attribute
1200
1201 Type: :code:`float`
1202 """
1203 )
1204
1205 oroll_frequency = Instrument.measurement(
1206 "FDIAG OROLL,?",
1207 """
1208 Get the offset roller oscillator frequency corresponding to the current start
1209 frequency, except when the resolution bandwidth is less than or equal to 100 Hz.
1210
1211 Diagnostic Attribute
1212
1213 Type: :code:`float`
1214 """
1215 )
1216
1217 xroll_frequency = Instrument.measurement(
1218 "FDIAG XROLL,?",
1219 """
1220 Get the transfer roller oscillator frequency corresponding to the current start
1221 frequency, except when the resolution bandwidth is less than or equal to 100 Hz.
1222
1223 Diagnostic Attribute
1224
1225 Type: :code:`float`
1226 """
1227 )
1228
1229 sampler_harmonic_number = Instrument.measurement(
1230 "FDIAG HARM,?",
1231 """
1232 Get the sampler harmonic number corresponding to the current start
1233 frequency.
1234
1235 Diagnostic Attribute
1236
1237 Type: :code:`int`
1238 """,
1239 get_process=lambda v: int(float(v))
1240 )
1241
1242 # practically you could also write "OFF" to actively disable it or reset via "IP"
1243 frequency_display_enabled = Instrument.measurement(
1244 "FDSP?",
1245 """
1246 Get the state of all annotations that describes the spectrum analyzer frequency.
1247 returns 'False' if no annotations are shown and vice versa 'True'. This includes the start
1248 and stop frequencies, the center frequency, the frequency span, marker readouts, the center
1249 frequency step-size, and signal identification to center frequency. To retrieve the
1250 frequency data, query the spectrum analyzer.
1251
1252 Type: :code:`bool`
1253
1254 .. code-block:: python
1255
1256 if instr.frequency_display:
1257 print("Frequencies get displayed")
1258
1259 """,
1260 map_values=True,
1261 values={True: "1", False: "0"},
1262 cast=str
1263 )
1264
1265 def do_fft(self, source, destination, window):
1266 """Calculate and show a discrete Fourier transform.
1267
1268 The FFT command performs a discrete Fourier transform on the source
1269 trace array and stores the logarithms of the magnitudes of the results
1270 in the destination array. The maximum length of any of the traces is
1271 601 points. FFT is designed to be used in transforming zero-span
1272 amplitude-modulation information into the frequency domain. Performing
1273 an FFT on a frequency sweep will not provide time-domain results. The
1274 FFT results are displayed on the spectrum analyzer in a logarithmic
1275 amplitude scale. For the horizontal dimension, the frequency at the
1276 left side of the graph is 0 Hz, and at the right side is Finax- Fmax is
1277 equal to 300 divided by sweep time. As an example, if the sweep time of
1278 the analyzer is 60 ms, Fmax equals 5 kHz. The FFT algorithm assumes
1279 that the sampled signal is periodic with an integral number of periods
1280 within the time-record length (that is, the sweep time of the
1281 analyzer). Given this assumption, the transform computed is that of a
1282 time waveform of infinite duration, formed of concatenated time
1283 records. In actual measurements, the number of periods of the sampled
1284 signal within the time record may not be integral. In this case, there
1285 is a step discontinuity at the intersections of the concatenated time
1286 records in the assumed time waveform of infinite duration. This step
1287 discontinuity causes measurement errors, both amplitude uncertainty
1288 (where the signal level appears to vary with small changes in
1289 frequency) and frequency resolution (due to filter shape factor and
1290 sidelobes). Windows are weighting functions that are applied to the
1291 input data to force the ends of that data smoothly to zero, thus
1292 reducing the step discontinuity and reducing measuremen errors.
1293
1294 :param source: A representation of the trace, either from :class:`Trace` or
1295 use 'TRA' for Trace A or 'TRB' for Trace B
1296 :param destination: A representation of the trace, either from :class:`Trace` or
1297 use 'TRA' for Trace A or 'TRB' for Trace B
1298 :param window: A representation of the trace, either from :class:`Trace` or
1299 use 'TRA' for Trace A or 'TRB' for Trace B
1300
1301 :type source: str
1302 :type destination: str
1303 :type window: str
1304 """
1305 if not isinstance(source, str):
1306 raise TypeError("Should be of type string but is '%s'" % type(source))
1307
1308 if not isinstance(destination, str):
1309 raise TypeError("Should be of type string but is '%s'" % type(destination))
1310
1311 if not isinstance(window, str):
1312 raise TypeError("Should be of type string but is '%s'" % type(window))
1313
1314 if source not in [e for e in Trace]:
1315 raise ValueError("Only accepts values of [%s] but was '%s'" % ([e for e in Trace],
1316 source))
1317 if destination not in [e for e in Trace]:
1318 raise ValueError("Only accepts values of [%s] but was '%s'" % ([e for e in Trace],
1319 destination))
1320 if window not in [e for e in Trace]:
1321 raise ValueError("Only accepts values of [%s] but was '%s'" % ([e for e in Trace],
1322 window))
1323 self.write("FFT %s,%s,%s" % (source, destination, window))
1324
1325 frequency_offset = Instrument.control(
1326 "FOFFSET?", "FOFFSET %.11E Hz",
1327 """
1328 Control an offset added to the displayed absolute-frequency values,
1329 including marker-frequency values.
1330
1331 It does not affect the frequency range of the sweep, nor
1332 does it affect relative frequency readouts. When this function is active, an "F" appears on
1333 the left side of the display.
1334 Changes all the following frequency measurements.
1335
1336 Type: :code:`float`
1337
1338 .. code-block:: python
1339
1340 instr.frequency_offset = 2e6
1341 if instr.frequency_offset == 2e6:
1342 print("Correct frequency")
1343
1344 """,
1345 validator=strict_range,
1346 values=[0, 1],
1347 dynamic=True
1348 )
1349
1350 frequency_reference_source = Instrument.control(
1351 "FREF?", "FREF %s",
1352 """
1353 Control the frequency reference source.
1354 Select either the internal frequency reference (INT) or supply your own external
1355 reference (EXT). An external reference must be 10 MHz (+100 Hz) at a minimum amplitude of
1356 0 dBm. Connect the external reference to J9 (10 MHz REF IN/OUT) on the rear panel. When
1357 the external mode is selected, an "X" appears on the left edge of the display.
1358
1359 Type: :code:`str`
1360
1361 Takes element of :class:`FrequencyReference` or use 'INT', 'EXT'
1362
1363 .. code-block:: python
1364
1365 instr.frequency_reference_source = 'INT'
1366 instr.frequency_reference_source = FrequencyReference.EXT
1367
1368 if instr.frequency_reference_source == FrequencyReference.INT:
1369 instr.frequency_reference_source = FrequencyReference.EXT
1370
1371 """,
1372 validator=strict_discrete_set,
1373 values=[e for e in FrequencyReference]
1374 )
1375
1376 def set_full_span(self):
1377 """Set the spectrum analyzer to the full frequency span as defined by
1378 the instrument.
1379
1380 The full span is 2.9 GHz for the HP 8560A. For the HP 8561B, the
1381 full span is 6.5 GHz.
1382 """
1383 self.write("FS")
1384
1385 graticule_enabled = Instrument.control(
1386 "GRAT?", "GRAT %s",
1387 """
1388 Control the display graticule. Switch it either on or off.
1389
1390 Type: :class:`bool`
1391
1392 .. code-block:: python
1393
1394 instr.graticule = True
1395
1396 if instr.graticule:
1397 pass
1398
1399 """,
1400 map_values=True,
1401 values={True: "1", False: "0"},
1402 validator=strict_discrete_set,
1403 cast=str
1404 )
1405
1406 def hold(self):
1407 """Freeze the active function at its current value.
1408
1409 If no function is active, no operation takes place.
1410 """
1411 self.write("HD")
1412
1413 id = Instrument.measurement(
1414 "ID?",
1415 """
1416 Get the identification of the device with software and hardware revision (e.g. HP8560A,002,
1417 H03)
1418
1419 Type: :class:`str`
1420
1421 .. code-block:: python
1422
1423 print(instr.id)
1424 HP8560A,002,H02
1425
1426 """,
1427 maxsplit=0,
1428 cast=str
1429 )
1430
1431 def preset(self):
1432 """Set the spectrum analyzer to a known, predefined state.
1433
1434 'preset' does not affect the contents of any data or trace
1435 registers or stored preselector data. 'preset' does not clear
1436 the input or output data buffers;
1437 """
1438 self.write("IP")
1439
1440 logarithmic_scale = Instrument.control(
1441 "LG?", "LG %d DB",
1442 """
1443 Control the logarithmic amplitude scale. When in linear
1444 mode, querying 'logarithmic_scale' returns a “0”.
1445 Allowed values are 0, 1, 2, 5, 10
1446
1447 Type: :class:`int`
1448
1449 .. code-block:: python
1450
1451 if instr.logarithmic_scale:
1452 pass
1453
1454 # set the scale to 10 db per division
1455 instr.logarithmic_scale = 10
1456
1457 """,
1458 cast=int,
1459 validator=strict_discrete_set,
1460 values=[0, 1, 2, 5, 10]
1461 )
1462
1463 def set_linear_scale(self):
1464 """Set the spectrum analyzers display to linear amplitude scale.
1465
1466 Measurements made on a linear scale can be read out in any
1467 units.
1468 """
1469 self.write("LN")
1470
1471 def set_minimum_hold(self, trace):
1472 """Update the chosen trace with the minimum signal level detected at
1473 each trace-data point from subsequent sweeps. This function employs the
1474 negative peak detector (refer to the :attr:`detector_mode` command).
1475
1476 .. code-block:: python
1477
1478 instr.minimum_hold('TRA')
1479 instr.minimum_hold(Trace.A)
1480
1481 :param trace: A representation of the trace, either from :class:`Trace` or
1482 use 'TRA' for Trace A or 'TRB' for Trace B
1483
1484 :type trace: str
1485 :raises TypeError: Type isn't 'string'
1486 :raises ValueError: Value is 'TRA' nor 'TRB'
1487 """
1488 if not isinstance(trace, str):
1489 raise TypeError("Should be of type string but is '%s'" % type(trace))
1490
1491 if trace not in [e for e in Trace]:
1492 raise ValueError("Only accepts values of [%s] but was '%s'" % ([e for e in Trace],
1493 trace))
1494
1495 self.write("MINH %s" % trace)
1496
1497 marker_amplitude = Instrument.measurement(
1498 "MKA?",
1499 """
1500 Get the amplitude of the active marker. If no marker is active, MKA
1501 places a marker at the center of the trace and returns that amplitude value.
1502 In the :meth:`amplitude_unit` unit.
1503
1504 Type: :code:`float`
1505
1506 .. code-block:: python
1507
1508 level = instr.marker_amplitude
1509 unit = instr.amplitude_unit
1510 print("Level: %f %s" % (level, unit))
1511
1512 """
1513 )
1514
1515 def set_marker_to_center_frequency(self):
1516 """Set the center frequency to the frequency value of an active
1517 marker."""
1518 self.write("MKCF")
1519
1520 marker_delta = Instrument.control(
1521 "MKD?", "MKD %.11E Hz",
1522 """
1523 Control a second marker on the trace. The parameter value specifies the distance
1524 in frequency or time (when in zero span) between the two markers.
1525 If queried - returns the frequency or time of the second marker.
1526
1527 Type: :code:`float`
1528
1529 .. code-block:: python
1530
1531 # place second marker 1 MHz apart from the first marker
1532 instr.marker_delta = 1e6
1533
1534 # print frequency of second marker in case it got moved automatically
1535 print(instr.marker_delta)
1536
1537 """
1538 )
1539
1540 # the documentation mentions this command, but it doesn't work on my unit and a
1541 # reference unit so I leave it here for reference but commented out
1542 #
1543 # marker_reciprocal = Instrument.control(
1544 # "MKDR?", "MKDR %.11E",
1545 # """
1546 # Return the reciprocal of the frequency or time (when in zero span)
1547 # difference between two markers.
1548 # """
1549 # )
1550
1551 marker_frequency = Instrument.control(
1552 "MKF?", "MKF %.11E Hz",
1553 """
1554 Control the frequency of the active marker.
1555 Default units are in Hertz.
1556
1557 Type: :code:`float`
1558
1559 .. code-block:: python
1560
1561 # place marker no. 1 at 100 MHz
1562 instr.marker_frequency = 100e6
1563
1564 # print frequency of the marker in case it got moved automatically
1565 print(instr.marker_frequency)
1566
1567 """,
1568 validator=strict_range,
1569 values=[0, 1],
1570 dynamic=True
1571 )
1572
1573 frequency_counter_mode_enabled = Instrument.setting(
1574 "MKFC %s",
1575 """
1576 Set the device into a frequency counter mode that counts the frequency of the active
1577 marker or the difference in frequency between two markers. If no marker
1578 is active, 'frequency_counter_mode_enabled' places a marker at the center of
1579 the trace and counts that marker frequency. The frequency counter
1580 provides a more accurate frequency reading; it pauses at the marker,
1581 counts the value, then continues the sweep. To adjust the frequency
1582 counter resolution, use the 'frequency_counter_resolution' command. To
1583 return the counter value, use the 'marker_frequency' command.
1584
1585 .. code-block:: python
1586
1587 instr.frequency_counter_mode_enabled = True
1588 """,
1589 map_values=True,
1590 values={True: "ON", False: "OFF"},
1591 validator=strict_discrete_set
1592 )
1593
1594 frequency_counter_resolution = Instrument.control(
1595 "MKFCR?", "MKFCR %d Hz",
1596 """
1597 Control the resolution of the frequency counter. Refer to the 'frequency_counter_mode'
1598 command. The default value is 10 kHz.
1599
1600 Type :code:`int`
1601
1602 .. code-block:: python
1603
1604 # activate frequency counter mode
1605 instr.frequency_counter_mode = True
1606
1607 # adjust resolution to 1 Hz
1608 instr.frequency_counter_resolution = 1
1609
1610 if instr.frequency_counter_resolution:
1611 pass
1612
1613 """,
1614 validator=strict_range,
1615 values=[1, 1e1, 1e2, 1e3, 1e4, 1e5, 1e6],
1616 maxsplit=0,
1617 preprocess_reply=lambda v: str(int(float(v))),
1618 cast=int
1619 )
1620
1621 def set_marker_minimum(self):
1622 """Place an active marker on the minimum signal detected on a trace."""
1623 self.write("MKMIN")
1624
1625 # here would be the implementation of the command 'marker_normal' ('MKN') but
1626 # it has no advantage over the 'marker_frequency' command except if no marker is active it
1627 # places it automagically to the center of the trace (I think there's no sense in
1628 # implementing it here)
1629
1630 marker_noise_mode_enabled = Instrument.control(
1631 "MKNOISE?", "MKNOISE %s",
1632 """
1633 Control the detector mode to sample and compute the average of 32 data points (16 points
1634 on one side of the marker, the marker itself, and 15 points on the other side of the
1635 marker). This average is corrected for effects of the log or linear amplifier, bandwidth
1636 shape factor, IF detector, and resolution bandwidth. If two markers are on (whether in
1637 'marker_delta' mode or 1/marker delta mode), 'marker_noise_mode_enabled' works on the active
1638 marker and not on the anchor marker. This allows you to measure signal-to-noise density
1639 directly. To query the value, use the 'marker_amplitude' command.
1640
1641 Type: :code:`bool`
1642
1643 .. code-block:: python
1644
1645 # activate signal-to-noise density mode
1646 instr.marker_noise_mode_enabled = True
1647
1648 # get noise density by `marker_amplitude`
1649 print("Signal-to-noise density: %d dbm / Hz" % instr.marker_amplitude)
1650
1651 """,
1652 map_values=True,
1653 values={True: "1", False: "0"},
1654 cast=str
1655 )
1656
1657 def deactivate_marker(self, all_markers=False):
1658 """Turn off the active marker or, if specified, turn off all markers.
1659
1660 :param all_markers: If True the call deactivates all markers, if false only the currently
1661 active marker (optional)
1662 :type all_markers: bool
1663
1664 .. code-block:: python
1665
1666 # place first marker at 300 MHz
1667 instr.marker_frequency = 300e6
1668
1669 # place second marker 2 MHz apart from first
1670 instr.marker_delta = 2e6
1671
1672 # deactivate active marker (delta marker)
1673 instr.deactivate_marker()
1674
1675 # deactivate all markers
1676 instr.deactivate_marker(all_markers=True)
1677 """
1678 if all_markers:
1679 self.write("MKOFF ALL")
1680 else:
1681 self.write("MKOFF")
1682
1683 def search_peak(self, mode):
1684 """Place a marker on the highest point on a trace, the next-highest
1685 point, the next-left peak, or the next-right peak. The default is 'HI'
1686 (highest point). The trace peaks must meet the criteria of the marker
1687 threshold and peak excursion functions in order for a peak to be found.
1688 See also the :attr:`peak_threshold` and :attr:`peak_excursion`
1689 commands.
1690
1691 :param mode: Takes 'HI', 'NH', 'NR', 'NL' or the enumeration :class:`PeakSearchMode`
1692 :type mode: str
1693
1694 .. code-block:: python
1695
1696 instr.search_peak('NL')
1697 instr.search_peak(PeakSearchMode.NextHigh)
1698 """
1699 if not isinstance(mode, str):
1700 raise TypeError("Should be of type string but is '%s'" % type(mode))
1701
1702 if mode not in [e for e in PeakSearchMode]:
1703 raise ValueError("Only accepts values of [%s] but was '%s'" %
1704 ([e for e in PeakSearchMode], mode))
1705
1706 self.write("MKPK %s" % mode)
1707
1708 marker_threshold = Instrument.control(
1709 "MKPT?", "MKPT %g {amplitude_unit}",
1710 """
1711 Control the minimum amplitude level from which a peak on the trace can
1712 be detected. The default value is -130 dBm. See also the :attr:`peak_excursion` command.
1713 Any portion of a peak that falls below the peak threshold is used to satisfy the peak
1714 excursion criteria. For example, a peak that is equal to 3 dB above the threshold when
1715 the peak excursion is equal to 6 dB will be found if the peak extends an additional 3 dB
1716 or more below the threshold level. Maximum 30 db to minimum -200 db.
1717
1718 Type: :code:`signed int`
1719
1720 .. code-block:: python
1721
1722 instr.marker_threshold = -70
1723 if instr.marker_threshold > -80:
1724 pass
1725
1726 """,
1727 validator=strict_range,
1728 values=[-200, 30]
1729 )
1730
1731 peak_excursion = Instrument.control(
1732 "MKPX?", "MKPX %g DB",
1733 """
1734 Control what constitutes a peak on a trace. The chosen value specifies
1735 the amount that a trace must increase monotonically, then decrease monotonically, in order
1736 to be a peak. For example, if the peak excursion is 10 dB, the amplitude of the sides of a
1737 candidate peak must descend at least 10 dB in order to be considered a peak (see Figure 5-4)
1738 The default value is 6 dB. In linear mode, enter the marker peak excursion as a unit-less
1739 number.
1740 Any portion of a peak that falls below the peak threshold is also used to satisfy the peak
1741 excursion criteria. For example, a peak that is equal to 3 dB above the threshold when the
1742 peak excursion is equal to 6 dB will be found if the peak extends an additional 3 dB or more
1743 below the threshold level.
1744
1745 Type: :code:`float`
1746
1747 .. code-block:: python
1748
1749 instr.peak_excursion = 2
1750 if instr.peak_excursion == 2:
1751 pass
1752
1753 """,
1754 validator=strict_range,
1755 values=[0.1, 99]
1756 )
1757
1758 def set_marker_to_reference_level(self):
1759 """Set the reference level to the amplitude of an active marker.
1760
1761 If no marker is active, 'marker_to_reference_level' places a
1762 marker at the center of the trace and uses that marker amplitude
1763 to set the reference level.
1764 """
1765 self.write("MKRL")
1766
1767 def set_marker_delta_to_span(self):
1768 """Set the frequency span equal to the frequency difference between two
1769 markers on a trace.
1770
1771 The start frequency is set equal to the frequency of the left-
1772 most marker and the stop frequency is set equal to the frequency
1773 of the right-most marker.
1774 """
1775 self.write("MKSP")
1776
1777 def set_marker_to_center_frequency_step_size(self):
1778 """Set the center frequency step-size equal to the frequency value of
1779 the active marker."""
1780 self.write("MKSS")
1781
1782 marker_time = Instrument.control(
1783 "MKT?", "MKT %gS",
1784 """
1785 Control the marker's time value. Default units are seconds.
1786
1787 Type: :code:`float`
1788
1789 .. code-block:: python
1790
1791 # set marker at sweep time corresponding second two
1792 instr.marker_time = 2
1793
1794 if instr.marker_time == 2:
1795 pass
1796
1797 """
1798 )
1799
1800 marker_signal_tracking_enabled = Instrument.control(
1801 "MKTRACK?", "MKTRACK %s",
1802 """
1803 Control whether the center frequency follows the active marker.
1804
1805 This is done after every sweep, thus maintaining the marker value at the
1806 center frequency. This allows you to “zoom in” quickly from a wide span to a narrow one,
1807 without losing the signal from the screen. Or, use 'marker_signal_tracking_enabled' to keep
1808 a slowly drifting signal centered on the display. When this function is active,
1809 a "K" appears on the left edge of the display.
1810
1811 Type: :code:`bool`
1812 """,
1813 map_values=True,
1814 validator=strict_discrete_set,
1815 values={True: "1", False: "0"},
1816 cast=str
1817 )
1818
1819 mixer_level = Instrument.control(
1820 "ML?", "ML %d DB",
1821 """
1822 Control the maximum signal level that is at the input mixer. The
1823 attenuator automatically adjusts to ensure that this level is not exceeded for signals less
1824 than the reference level. From -80 to -10 DB.
1825
1826 Type: :code:`int`
1827 """,
1828 validator=strict_range,
1829 cast=int,
1830 values=[-80, -10]
1831 )
1832
1833 def set_maximum_hold(self, trace):
1834 """Set the chosen trace with the maximum signal level detected at each
1835 trace-data point from subsequent sweeps. This function employs the
1836 positive peak detector (refer to the :attr:`detector_mode` command).
1837 The detector mode can be changed, if desired, after max hold is
1838 initialized.
1839
1840 .. code-block:: python
1841
1842 instr.maximum_hold('TRA')
1843 instr.maximum_hold(Trace.A)
1844
1845 :param trace: A representation of the trace, either from :class:`Trace` or
1846 use 'TRA' for Trace A or 'TRB' for Trace B
1847
1848 :type trace: str
1849 :raises TypeError: Type isn't 'string'
1850 :raises ValueError: Value is 'TRA' nor 'TRB'
1851 """
1852 if not isinstance(trace, str):
1853 raise TypeError("Should be of type string but is '%s'" % type(trace))
1854
1855 if trace not in [e for e in Trace]:
1856 raise ValueError("Only accepts values of [%s] but was '%s'" % ([e for e in Trace],
1857 trace))
1858
1859 self.write("MXMH %s" % trace)
1860
1861 normalize_trace_data_enabled = Instrument.control(
1862 "NORMLIZE?", "NORMLIZE %s",
1863 """
1864 Control the normalization routine for
1865 stimulus-response measurements. This function subtracts trace B from trace A, offsets the
1866 result by the value of the normalized reference position
1867 (:attr:`normalized_reference_level`), and displays the result in trace A.
1868 'normalize_trace_data_enabled' is intended for use with the :meth:`store_open` and
1869 :meth:`store_short` or :meth:`store_thru` commands. These functions are used to store a
1870 reference trace into trace B.
1871 Refer to the respective command descriptions for more information.
1872 Accurate normalization occurs only if the reference trace and the measured trace are
1873 on-screen. If any of these traces are off-screen, an error message will be displayed.
1874 If the error message ERR 903 A > DLMT is displayed, the range level (RL) can be adjusted
1875 to move the measured response within the displayed measurement range of the analyzer. If
1876 ERR 904 B > DLMT is displayed, the calibration is invalid and a thru or open/short
1877 calibration must be performed.
1878 If active (ON), the 'normalize_trace_data' command is automatically turned off with an
1879 instrument preset (IP) or at power on.
1880
1881 Type: :code:`bool`
1882 """,
1883 map_values=True,
1884 validator=strict_discrete_set,
1885 values={True: "1", False: "0"},
1886 cast=str
1887 )
1888
1889 normalized_reference_level = Instrument.control(
1890 "NRL?", "NRL %d {amplitude_unit}",
1891 """
1892 Control the normalized reference level. It is intended to be used with the
1893 :attr:`normalize_trace_data` command. When using 'normalized_reference_level', the input
1894 attenuator and IF step gains are not affected. This function is a trace-offset function
1895 enabling the user to offset the displayed trace without introducing hardware-switching
1896 errors into the stimulus-response measurement. The unit of measure for
1897 'normalized_reference_level' is dB. In absolute power mode (dBm), reference level (
1898 :attr:`reference_level`) affects the gain and RF attenuation settings of the instrument,
1899 which affects the measurement or dynamic range. In normalized mode
1900 (relative power or dB-measurement mode), NRL offsets the trace data on-screen and does
1901 not affect the instrument gain or attenuation settings. This allows the displayed
1902 normalized trace to be moved without decreasing the measurement accuracy due to changes
1903 in gain or RF attenuation. If the measurement range must be changed to bring trace data
1904 on-screen, then the range level should be adjusted. Adjusting the range-level normalized
1905 mode has the same effect on the instrument settings as does reference level in absolute
1906 power mode (normalize off).
1907
1908 Type: :code:`int`
1909
1910 .. code-block:: python
1911
1912 # reference level in case of normalization to -30 DB
1913 instr.normalized_reference_level = -30
1914
1915 if instr.normalized_reference_level == -30:
1916 pass
1917 """,
1918 validator=strict_range,
1919 values=[-200, 30],
1920 cast=int
1921 )
1922
1923 normalized_reference_position = Instrument.control(
1924 "NRPOS?", "NRPOS %f DB",
1925 """
1926 Control the normalized reference-position that corresponds to the
1927 position on the graticule where the difference between the measured and calibrated traces
1928 resides. The dB value of the normalized reference-position is equal to the normalized
1929 reference level. The normalized reference-position may be adjusted between 0.0 and 10.0,
1930 corresponding to the bottom and top graticule lines, respectively.
1931
1932 Type: :code:`float`
1933
1934 .. code-block:: python
1935
1936 instr.normalized_reference_position = 5.5
1937
1938 if instr.normalized_reference_position == 5.5:
1939 pass
1940 """,
1941 validator=strict_range,
1942 values=[0.0, 10.0]
1943 )
1944
1945 display_parameters = Instrument.measurement(
1946 "OP?",
1947 """
1948 Get the location of the lower left (P1) and upper right (P2) vertices as a tuple of
1949 the display window.
1950
1951 Type: :code:`tuple`
1952
1953 .. code-block:: python
1954
1955 repr(instr.display_parameters)
1956 (72, 16, 712, 766)
1957
1958 """,
1959 maxsplit=4,
1960 cast=int,
1961 get_process=tuple
1962 )
1963
1964 def plot(self, p1x, p1y, p2x, p2y):
1965 """Copies the specified display contents onto any HP-GL plotter. Set
1966 the plotter address to 5, select the Pi and P2 positions, and then
1967 execute the plot command. P1 and P2 correspond to the lower-left and
1968 upper-right plotter positions, respectively. If P1 and P2 are not
1969 specified, default values (either preloaded from power-up or sent in
1970 via a previous plot command) are used. Once PLOT is executed, no
1971 subsequent commands are executed until PLOT is done.
1972
1973 :param p1x: plotter-dependent value that specify the lower-left plotter position x-axis
1974 :type p1x: int
1975 :param p1y: plotter-dependent value that specify the lower-left plotter position y-axis
1976 :type p1y: int
1977 :param p2x: plotter-dependent values that specify the upper-right plotter position x-axis
1978 :type p2x: int
1979 :param p2y: plotter-dependent values that specify the upper-right plotter position y-axis
1980 :type p2y: int
1981 """
1982 if not (isinstance(p1x, int) or isinstance(p1y, int) or isinstance(p2x, int) or
1983 isinstance(p2y, int)):
1984 raise TypeError("Should be of type int")
1985
1986 self.write("PLOT %d,%d,%d,%d" % (p1x, p1y, p2x, p2y))
1987
1988 protect_state_enabled = Instrument.control(
1989 "PSTATE?", "PSTATE %s",
1990 """
1991 Control the storing of any new data in the state or trace registers.
1992 If set to 'True', the registers are “locked”; the data in them cannot be erased or
1993 overwritten, although the data can be recalled. To “unlock” the registers, and store new
1994 data, set 'protect_state_enabled' to off by selecting 'False' as the parameter.
1995
1996 Type: :code:`bool`
1997 """,
1998 map_values=True,
1999 validator=strict_discrete_set,
2000 values={True: "1", False: "0"},
2001 cast=str
2002 )
2003
2004 def get_power_bandwidth(self, trace, percent):
2005 """Measure the combined power of all signal responses contained in a
2006 trace array. The command then computes the bandwidth equal to a
2007 percentage of the total power. For example, if 100% is specified, the
2008 power bandwidth equals the current frequency span. If 50% is specified,
2009 trace elements are eliminated from either end of the array, until the
2010 combined power of the remaining trace elements equals half of the total
2011 power computed. The frequency span of these remaining trace elements is
2012 the power bandwidth output to the controller.
2013
2014 :param trace: A representation of the trace, either from :class:`Trace` or
2015 use 'TRA' for Trace A or 'TRB' for Trace B
2016 :param percent: Percentage of total power 0 ... 100 %
2017 :type trace: str
2018 :type percent: float
2019
2020 .. code-block:: python
2021
2022 # reset spectrum analyzer
2023 instr.preset()
2024
2025 # set to single sweep mode
2026 instr.sweep_single()
2027
2028 instr.center_frequency = 300e6
2029 instr.span = 1e6
2030
2031 instr.maximum_hold()
2032
2033 instr.trigger_sweep()
2034
2035 if instr.done:
2036 pbw = instr.power_bandwidth(Trace.A, 99.0)
2037 print("The power bandwidth at 99 percent is %f kHz" % (pbw / 1e3))
2038 """
2039 ran = np.arange(0, 100, 0.1)
2040
2041 if not isinstance(trace, str):
2042 raise TypeError("Should be of type string but is '%s'" % type(trace))
2043
2044 if not isinstance(percent, float):
2045 raise TypeError("Should be of type float but is '%s'" % type(percent))
2046
2047 if trace not in [e for e in Trace]:
2048 raise ValueError("Only accepts values of [%s] but was '%s'" %
2049 ([e for e in Trace], trace))
2050
2051 if percent not in ran:
2052 raise ValueError("Only accepts values in the range of %s but was '%s'" %
2053 (ran, percent))
2054
2055 return float(self.ask("PWRBW %s,%.1f?" % (trace, percent)))
2056
2057 resolution_bandwidth = Instrument.control(
2058 "RB?", "RB %s",
2059 """
2060 Control the resolution bandwidth. This is normally a coupled function that
2061 is selected according to the ratio selected by the RBR command. If no ratio is selected, a
2062 default ratio (0.011) is used. The bandwidth, which ranges from 10 Hz to 2 MHz, may also be
2063 selected manually.
2064
2065 Type: :code:`str, dec`
2066 """,
2067 validator=joined_validators(strict_discrete_set, truncated_discrete_set),
2068 values=[["AUTO", "MAN"], np.arange(10, 2e6)],
2069 set_process=lambda v: v if isinstance(v, str) else f"{int(v)} Hz",
2070 get_process=lambda v: v if isinstance(v, str) else int(v)
2071 )
2072
2073 resolution_bandwidth_to_span_ratio = Instrument.control(
2074 "RBR?", "RBR %.3f",
2075 """
2076 Control the coupling ratio between the resolution bandwidth and the
2077 frequency span. When the frequency span is changed, the resolution bandwidth is changed
2078 to satisfy the selected ratio. The ratio ranges from 0.002 to 0.10. The “UP” and “DN”
2079 parameters adjust the ratio in a 1, 2, 5 sequence. The default ratio is 0.011.
2080 """,
2081 validator=strict_range,
2082 values=np.arange(0.002, 0.10, 0.001)
2083 )
2084
2085 def recall_open_short_average(self):
2086 """Set the internally stored open/short average reference trace into
2087 trace B. The instrument state is also set to the stored open/short
2088 reference state.
2089
2090 .. code-block:: python
2091
2092 instr.preset()
2093 instr.sweep_single()
2094 instr.start_frequency = 300e3
2095 instr.stop_frequency = 1e9
2096
2097 instr.source_power_enabled = True
2098 instr.sweep_couple = SweepCoupleMode.StimulusResponse
2099 instr.source_peak_tracking()
2100
2101 input("CONNECT OPEN. PRESS CONTINUE WHEN READY TO STORE.")
2102 instr.trigger_sweep()
2103 instr.done()
2104 instr.store_open()
2105
2106 input("CONNECT SHORT. PRESS CONTINUE WHEN READY TO STORE AND AVERAGE.")
2107 instr.trigger_sweep()
2108 instr.done()
2109 instr.store_short()
2110
2111 input("RECONNECT DUT. PRESS CONTINUE WHEN READY.")
2112 instr.trigger_sweep()
2113 instr.done()
2114
2115 instr.normalize = True
2116
2117 instr.trigger_sweep()
2118 instr.done()
2119
2120 instr.normalized_reference_position = 8
2121 instr.trigger_sweep()
2122
2123 instr.preset()
2124 # demonstrate recall of open/short average trace
2125 instr.recall_open_short_average()
2126 instr.trigger_sweep()
2127 """
2128 self.write("RCLOSCAL")
2129
2130 def recall_state(self, inp):
2131 """Set to the display a previously saved instrument state. See
2132 :meth:`save_state`.
2133
2134 :param inp: State to be recalled: either storage slot 0 ... 9 or 'LAST' or 'PWRON'
2135 :param inp: str, int
2136
2137 .. code-block:: python
2138
2139 instr.save_state(7)
2140 instr.preset()
2141 instr.recall_state(7)
2142 """
2143 values = ["LAST", "PWRON"] + [str(f) for f in range(0, 9)]
2144 if not (isinstance(inp, str) or isinstance(inp, int)):
2145 raise TypeError("Should be of type 'str' or 'int' but is '%s'" % type(inp))
2146
2147 if str(inp) not in values:
2148 raise ValueError("Only accepts values of [%s] but was '%s'" %
2149 (values, str(inp)))
2150
2151 self.write("RCLS %s" % str(inp))
2152
2153 def recall_trace(self, trace, number):
2154 """Recalls previously saved trace data to the display. See
2155 :meth:`save_trace`. Either as Trace A or Trace B.
2156
2157 :param trace: A representation of the trace, either from :class:`Trace` or
2158 use 'TRA' for Trace A or 'TRB' for Trace B
2159 :param number: Storage location from 0 ... 7 where to store the trace
2160 :type trace: str
2161 :type number: int
2162
2163 .. code-block:: python
2164
2165 instr.preset()
2166 instr.center_frequency = 300e6
2167 instr.span = 20e6
2168
2169 instr.save_trace(Trace.A, 7)
2170 instr.preset()
2171
2172 # reload - at 7 stored trace - to Trace B
2173 instr.recall_trace(Trace.B, 7)
2174 """
2175 ran = range(0, 7)
2176 if not isinstance(trace, str):
2177 raise TypeError("Should be of type str but is '%s'" % type(trace))
2178
2179 if not isinstance(number, int):
2180 raise TypeError("Should be of type int but is '%s'" % type(number))
2181
2182 if trace not in [e for e in Trace]:
2183 raise ValueError("Only accepts values of [%s] but was '%s'" %
2184 ([e for e in Trace], trace))
2185
2186 if number not in ran:
2187 raise ValueError("Only accepts values of [%s] but was '%s'" %
2188 (ran, number))
2189
2190 self.write("RCLT %s,%s" % (trace, number))
2191
2192 def recall_thru(self):
2193 """Recalls the internally stored thru-reference trace into trace B.
2194
2195 The instrument state is also set to the stored thru-reference
2196 state.
2197 """
2198 self.write("RCLTHRU")
2199
2200 firmware_revision = Instrument.measurement(
2201 "REV?",
2202 """
2203 Get the revision date code of the spectrum analyzer firmware.
2204
2205 Type: :code:`datetime.date`
2206 """,
2207 get_process=lambda v: datetime.strptime(v, '%y%m%d').date(),
2208 cast=str
2209 )
2210
2211 reference_level = Instrument.control(
2212 "RL?", "RL %g {amplitude_unit}",
2213 """
2214 Control the reference level, or range level when in normalized mode. (Range level
2215 functions the same as reference level.) The reference level is the top horizontal line on
2216 the graticule. For best measurement accuracy, place the peak of a signal of interest on the
2217 reference-level line. The spectrum analyzer input attenuator is coupled to the reference
2218 level and automatically adjusts to avoid compression of the input signal. Refer also to
2219 :attr:`amplitude_unit`. Minimum reference level is -120.0 dBm or 2.2 uV
2220
2221 Type: :code:`float`
2222 """
2223 )
2224
2225 reference_level_calibration = Instrument.control(
2226 "RLCAL?", "RLCAL %g",
2227 """
2228 Control the calibration of the reference level remotely and retuns the
2229 current calibration. To calibrate the reference level, connect the 300 MHz calibration
2230 signal to the RF input. Set the center frequency to 300 MHz, the frequency span to 20
2231 MHz, and the reference level to -10 dBm. Use the RLCAL command to move the input signal
2232 to the reference level. When the signal peak falls directly on the reference-level line,
2233 the reference level is calibrated. Storing this value in the analyzer in EEROM can be
2234 done only from the front panel. The RLCAL command, when queried, returns the current value.
2235
2236 Type: :code:`float`
2237
2238 .. code-block:: python
2239
2240 # connect cal signal to rf input
2241 instr.preset()
2242 instr.amplitude_unit = AmplitudeUnits.DBM
2243 instr.center_frequency = 300e6
2244 instr.span = 100e3
2245 instr.reference_level = 0
2246 instr.trigger_sweep()
2247
2248 instr.peak_search(PeakSearchMode.High)
2249 level = instr.marker_amplitude
2250 rlcal = instr.reference_level_calibration - int((level + 10) / 0.17)
2251 instr.reference_level_calibration = rlcal
2252 """,
2253 cast=int,
2254 validator=strict_range,
2255 values=[-33, 33]
2256 )
2257
2258 reference_offset = Instrument.control(
2259 "ROFFSET?", "ROFFSET %d DB",
2260 """
2261 Control an offset applied to all amplitude readouts (for example, the
2262 reference level and marker amplitude). The offset is in dB, regardless of the selected scale
2263 and units. The offset can be useful to account for gains of losses in accessories connected
2264 to the input of the analyzer. When this function is active, an "R" appears on the left
2265 edge of the display.
2266
2267 Type: :code:`int`
2268 """,
2269 cast=int,
2270 values=[-100, 100],
2271 validator=strict_range
2272 )
2273
2274 request_service_conditions = Instrument.control(
2275 "RQS?", "RQS %d",
2276 """
2277 Control a bit mask that specifies which service requests can interrupt
2278 a program sequence.
2279
2280 .. code-block:: python
2281
2282 instr.request_service_conditions = StatusRegister.ERROR_PRESENT | StatusRegister.TRIGGER
2283
2284 print(instr.request_service_conditions)
2285 StatusRegister.ERROR_PRESENT|TRIGGER
2286 """,
2287 get_process=lambda v: StatusRegister(int(v))
2288 )
2289
2290 def save_state(self, inp):
2291 """Saves the currently displayed instrument state in the specified
2292 state register.
2293
2294 :param inp: State to be recalled: either storage slot 0 ... 9 or 'LAST' or 'PWRON'
2295 :param inp: str, int
2296
2297 .. code-block:: python
2298
2299 instr.preset()
2300 instr.center_frequency = 300e6
2301 instr.span = 20e6
2302 instr.save_state("PWRON")
2303 """
2304 values = ["PWRON"] + [str(f) for f in range(0, 9)]
2305 if not (isinstance(inp, str) or isinstance(inp, int)):
2306 raise TypeError("Should be of type 'str' or 'int' but is '%s'" % type(inp))
2307
2308 if str(inp) not in values:
2309 raise ValueError("Only accepts values of [%s] but was '%s'" %
2310 (values, str(inp)))
2311
2312 self.write("SAVES %s" % str(inp))
2313
2314 def save_trace(self, trace, number):
2315 """Saves the selected trace in the specified trace register.
2316
2317 :param trace: A representation of the trace, either from :class:`Trace` or
2318 use 'TRA' for Trace A or 'TRB' for Trace B
2319 :param number: Storage location from 0 ... 7 where to store the trace
2320 :type trace: str
2321 :type number: int
2322
2323 .. code-block:: python
2324
2325 instr.preset()
2326 instr.center_frequency = 300e6
2327 instr.span = 20e6
2328
2329 instr.save_trace(Trace.A, 7)
2330 instr.preset()
2331
2332 # reload - at 7 stored trace - to Trace B
2333 instr.recall_trace(Trace.B, 7)
2334 """
2335 ran = range(0, 7)
2336 if not isinstance(trace, str):
2337 raise TypeError("Should be of type str but is '%s'" % type(trace))
2338
2339 if not isinstance(number, int):
2340 raise TypeError("Should be of type int but is '%s'" % type(number))
2341
2342 if trace not in [e for e in Trace]:
2343 raise ValueError("Only accepts values of [%s] but was '%s'" %
2344 ([e for e in Trace], trace))
2345
2346 if number not in ran:
2347 raise ValueError("Only accepts values of [%s] but was '%s'" %
2348 (ran, number))
2349
2350 self.write("SAVET %s,%s" % (trace, number))
2351
2352 serial_number = Instrument.measurement(
2353 "SER?",
2354 """
2355 Get the spectrum analyzer serial number.
2356 """,
2357 cast=str
2358 )
2359
2360 def sweep_single(self):
2361 """Sets the spectrum analyzer into single-sweep mode.
2362
2363 This mode allows only one sweep when trigger conditions are met.
2364 When this function is active, an 'S' appears on the left edge of
2365 the display.
2366 """
2367 self.write("SNGLS")
2368
2369 span = Instrument.control(
2370 "SP?", "SP %s",
2371 """
2372 Control the frequency span. The center frequency does not change with
2373 changes in the frequency span; start and stop frequencies do change. Setting the frequency
2374 span to 0 Hz effectively allows an amplitude-versus-time mode in which to view signals. This
2375 is especially useful for viewing modulation. Querying SP will leave the analyzer in center
2376 frequency /span mode.
2377 """,
2378 validator=joined_validators(strict_discrete_set, strict_range),
2379 values=[["FULL", "ZERO"], [float("-inf"), float("inf")]],
2380 set_process=lambda v: v if isinstance(v, str) else "%.11E Hz" % v,
2381 get_process=lambda v: v if isinstance(v, str) else v
2382 )
2383
2384 squelch = Instrument.control(
2385 "SQUELCH?", "SQUELCH %s",
2386 """
2387 Control the squelch level for demodulation. When this function is
2388 on, a dashed line indicating the squelch level appears on the display.
2389 A marker must be active and above the squelch line for demodulation to occur. Refer to
2390 the :attr:`demodulation_mode` command. The default value is -120 dBm.
2391
2392 Type: :code:`str,int`
2393
2394 .. code-block:: python
2395
2396 instr.preset()
2397 instr.start_frequency = 88e6
2398 instr.stop_frequency = 108e6
2399
2400 instr.peak_search(PeakSearchMode.High)
2401 instr.demodulation_time = 10
2402
2403 instr.squelch = -60
2404 instr.demodulation_mode = DemodulationMode.FM
2405 """,
2406 validator=joined_validators(strict_discrete_set, strict_range),
2407 values=[["ON", "OFF"], range(-220, 30)],
2408 set_process=lambda v: v if isinstance(v, str) else f"{v} {{amplitude_unit}}"
2409 )
2410
2411 squelch_enabled = Instrument.setting(
2412 "SQUELCH %s",
2413 """
2414 Set squelch for demodulation active or inactive. For further information see :attr:`squelch`
2415 """,
2416 map_values=True,
2417 values={True: "ON", False: "OFF"},
2418 validator=strict_discrete_set
2419 )
2420
2421 def request_service(self, input):
2422 """Triggers a service request. This command allows you to force a
2423 service request and test a program designed to handle service requests.
2424 However, the service request can be triggered only if it is first
2425 masked using the :attr:`request_service_conditions` command.
2426
2427 :param input: Bits to emulate a service request
2428 :type input: :class:`StatusRegister`
2429 """
2430 if input not in range(0, 255):
2431 raise ValueError("Bit mask needs to be between 0 ... 255")
2432
2433 self.write("SRQ %d" % input)
2434
2435 # `center_frequency_step_size` would be a command but is pretty unnecesary
2436
2437 sweep_time = Instrument.control(
2438 "ST?", "ST %s",
2439 """
2440 Control the sweep time. This is normally a coupled function which is
2441 automatically set to the optimum value allowed by the current instrument settings.
2442 Alternatively, you may specify the sweep time. Note that when the specified sweep time is
2443 too fast for the current instrument settings, the instrument is no longer calibrated and the
2444 message 'MEAS UNCAL' appears on the display. The sweep time cannot be adjusted when the
2445 resolution bandwidth is set to 10 Hz, 30 Hz, or 100 Hz.
2446
2447 Type: :code:`str, float`
2448
2449 Real from 50E—3 to 100 when the span is greater than 0 Hz; 50E—6 to 60 when
2450 the span equals 0 Hz. When the resolution bandwidth is <100 Hz, the sweep time
2451 cannot be adjusted.
2452 """,
2453 validator=joined_validators(strict_discrete_set, strict_range),
2454 values=[["AUTO", "MAN"], np.arange(50E-6, 100)],
2455 set_process=lambda v: v if isinstance(v, str) else ("%.3f S" % v)
2456 )
2457
2458 status = Instrument.measurement(
2459 "STB?",
2460 """
2461 Get the decimal equivalent of the bits set in the
2462 status byte (see the RQS and SRQ commands). STB is equivalent to a serial poll command.
2463 The RQS and associated bits are cleared in the same way that a serial poll command would
2464 clear them.
2465 """,
2466 get_process=lambda v: StatusRegister(int(v))
2467 )
2468
2469 def store_open(self):
2470 """Save the current instrument state and trace A into nonvolatile
2471 memory.
2472
2473 This command must be used in conjunction with the
2474 :meth:`store_short` command and must precede the
2475 :meth:`store_short` command. The data obtained during the store
2476 open procedure is averaged with the data obtained during the
2477 :meth:`store_short` procedure to provide an open/short
2478 calibration. The instrument state (that is, instrument settings)
2479 must not change between the :meth:`store_open` and
2480 :meth:`store_short` operations in order for the open/short
2481 calibration to be valid. Refer to the :meth:`store_short`
2482 command description for more information.
2483 """
2484 self.write("STOREOPEN")
2485
2486 def store_short(self):
2487 """Take currently displayed trace A data and averages this data with
2488 previously stored open data, and stores it in trace B.
2489
2490 This command is used in conjunction with the :meth:`store_open`
2491 command and must be preceded by it for proper operation. Refer
2492 to the :meth:`store_open` command description for more
2493 information. The state of the open/short average trace is stored
2494 in state register #8.
2495 """
2496 self.write("STORESHORT")
2497
2498 def store_thru(self):
2499 """Store a thru-calibration trace into trace B and into the nonvolatile
2500 memory of the spectrum analyzer.
2501
2502 The state of the thru information is stored in state register
2503 #9.
2504 """
2505 self.write("STORETHRU")
2506
2507 sweep_couple = Instrument.control(
2508 "SWPCPL?", "SWPCPL %s",
2509 """
2510 Control the sweep couple mode which is either a stimulus-response or spectrum-analyzer
2511 auto-coupled sweep time. In stimulus-response mode, auto-coupled sweep times are usually
2512 much faster for swept-response measurements. Stimulus-response auto-coupled sweep times
2513 are typicallly valid in stimulus-response measurements when the system’s frequency span is
2514 less than 20 times the bandwidth of the device under test.
2515
2516 Type: :code:`str` or :class:`SweepCoupleMode`
2517 """,
2518 validator=strict_discrete_set,
2519 values=[e for e in SweepCoupleMode]
2520 )
2521
2522 sweep_output = Instrument.control(
2523 "SWPOUT?", "SWPOUT %s",
2524 """
2525 Control the sweep-related signal that is available from J8 on the rear
2526 panel. FAV provides a dc ramp of 0.5V/GHz. RAMP provides a 0—10 V ramp corresponding
2527 to the sweep ramp that tunes the first local oscillator (LO). For the HP 8561B, in multiband
2528 sweeps one ramp is provided for each frequency band.
2529
2530 Type: :code:`str` or :class:`SweepOut`
2531 """,
2532 validator=strict_discrete_set,
2533 values=[e for e in SweepOut]
2534 )
2535
2536 trace_data_format = Instrument.control(
2537 "TDF?", "TDF %s",
2538 """
2539 Control the format used to input and output trace data (see the
2540 TRA/TRB command, You must specify the desired format when
2541 transferring data from the spectrum analyzer to a computer; this is optional when
2542 transferring data to the analyzer.
2543
2544 Type: :code:`str` or :class:`TraceDataFormat`
2545
2546 .. warning::
2547 Only needed for manual read out of trace data. Don't use this if you don't know what
2548 You are doing.
2549 """,
2550 validator=strict_discrete_set,
2551 values=[e for e in TraceDataFormat]
2552 )
2553
2554 threshold = Instrument.control(
2555 "TH?", "TH %.2E {amplitude_unit}",
2556 """
2557 Control the minimum amplitude level and clips data at this value. Default
2558 value is -90 dBm. See also - :attr:`marker_threshold` does not clip data below its threshold
2559
2560 Type: :code:`str, float` range -200 to 30
2561
2562 .. note::
2563 When a trace is in max-hold mode, if the threshold is raised above any of the
2564 trace data, the data below the threshold will be permanently lost.
2565 """,
2566 validator=strict_discrete_set,
2567 values=np.arange(-200, 30),
2568 )
2569
2570 threshold_enabled = Instrument.setting(
2571 "TH %s",
2572 """
2573 Set the threshold active or inactive. See :attr:`threshold`
2574 """,
2575 map_values=True,
2576 values={True: "ON", False: "OFF"},
2577 validator=strict_discrete_set
2578 )
2579
2580 def set_title(self, string):
2581 """Sets character data in the title area of the display, which is in
2582 the upper-right corner.
2583
2584 A title can be up to two rows of sixteen characters each, Carriage
2585 return and line feed characters are not allowed.
2586 """
2587 if not isinstance(string, str):
2588 raise TypeError("Parameter should be of type 'str'")
2589
2590 if len(string) > 32:
2591 raise ValueError("Title should have maximum 32 chars but has '%d'" % len(string))
2592
2593 self.write("TITLE@%s@" % string)
2594
2595 trigger_mode = Instrument.control(
2596 "TM?", "TM %s",
2597 """
2598 Control the trigger mode. Selected trigger conditions must be met in order for
2599 a sweep to occur. For the available modes refer to :class:`TriggerMode`.
2600 When any trigger mode other than free run is selected,
2601 a "T" appears on the left edge of the display.
2602 """,
2603 validator=strict_discrete_set,
2604 values=[e for e in TriggerMode]
2605 )
2606
2607 def _get_trace_data(self, trace):
2608 self.write("TDF M")
2609
2610 amp_units = str(self.ask("AUNITS?"))
2611 ref_lvl = float(self.ask("RL?"))
2612 log_scale = float(self.ask("LG?"))
2613
2614 cmd_str = ""
2615 if trace is Trace.A:
2616 cmd_str += "TRA?"
2617 elif trace is Trace.B:
2618 cmd_str += "TRB?"
2619
2620 values = self.values(cmd_str, cast=int)
2621
2622 if amp_units is AmplitudeUnits.W:
2623 # calculate dbm from watts
2624 ref_lvl = (10 * log10(ref_lvl)) + 30
2625 elif amp_units is AmplitudeUnits.DBUV:
2626 # calculate dbm from dbuv in 50 Ohm system
2627 ref_lvl = ref_lvl - 107
2628 elif amp_units is AmplitudeUnits.V:
2629 # calculate dbm from volts in 50 Ohm system
2630 ref_lvl = 20 * log10((ref_lvl / 0.05) ** 0.5)
2631 elif amp_units is AmplitudeUnits.DBMV:
2632 # calculate dbm from dbmv
2633 ref_lvl = ref_lvl - 46.9897
2634
2635 result_values = []
2636 for value in values:
2637 if log_scale != 0:
2638 result_value = round(ref_lvl + (log_scale * ((value - 600) / 60)), 2)
2639 result_values.append(result_value)
2640 else:
2641 raise NotImplementedError("Linear scaling isn't supported by get_trace_data_ ")
2642
2643 return result_values
2644
2645 def get_trace_data_a(self):
2646 """
2647 Get the data of trace A as a list.
2648
2649 The function returns the 601 data points as a list in the amplitude format.
2650 Right now it doesn't support the linear scaling due to the manual just being wrong.
2651 """
2652 return self._get_trace_data(Trace.A)
2653
2654 def get_trace_data_b(self):
2655 """
2656 Get the data of trace B as a list.
2657
2658 The function returns the 601 data points as a list in the amplitude format.
2659 Right now it doesn't support the linear scaling due to the manual just being wrong.
2660 """
2661 return self._get_trace_data(Trace.B)
2662
2663 set_trace_data_a = Instrument.setting(
2664 "TDF P;TRA %s",
2665 """
2666 Set the trace data of trace A.
2667
2668 .. warning::
2669
2670 The string based method this attribute is using takes its time. Something around 5000ms
2671 timeout at the adapter seems to work well.
2672 """,
2673 set_process=lambda v: (','.join([str(i) for i in v])),
2674 )
2675
2676 set_trace_data_b = Instrument.setting(
2677 "TDF P;TRB %s",
2678 """
2679 Set the trace data of trace B also allows to write the data.
2680
2681 .. warning::
2682
2683 The string based method this attribute is using takes its time. Something around 5000ms
2684 timeout at the adapter seems to work well.
2685 """,
2686 set_process=lambda v: (','.join([str(i) for i in v]))
2687 )
2688
2689 def trigger_sweep(self):
2690 """Command the spectrum analyzer to take one full sweep across the trace display.
2691 Commands following TS are not executed until after the analyzer has finished the trace
2692 sweep. This ensures that the instrument is set to a known condition before subsequent
2693 commands are executed.
2694 """
2695 self.write("TS")
2696
2697 def create_fft_trace_window(self, trace, window_mode):
2698 """Creates a window trace array for the fast Fourier transform (FFT) function.
2699
2700 The trace-window function creates a trace array according to three built-in
2701 algorithms: UNIFORM, HANNING, and FLATTOP. When used with the FFT command,
2702 the three algorithms give resultant passband shapes that represent a compromise among
2703 amplitude uncertainty, sensitivity, and frequency resolution. Refer to the FFT command
2704 description for more information.
2705
2706 :param trace: A representation of the trace, either from :class:`Trace` or
2707 use 'TRA' for Trace A or 'TRB' for Trace B
2708 :type trace: str
2709 :param window_mode: A representation of the window mode, either from :class:`WindowType` or
2710 use 'HANNING', 'FLATTOP' or 'UNIFORM'
2711 :type window_mode: str
2712 """
2713
2714 if not isinstance(trace, str):
2715 raise TypeError("Should be of type string but is '%s'" % type(trace))
2716
2717 if trace not in [e for e in Trace]:
2718 raise ValueError("Only accepts values of [%s] but was '%s'" % ([e for e in Trace],
2719 trace))
2720
2721 if not isinstance(window_mode, str):
2722 raise TypeError("Should be of type string but is '%s'" % type(window_mode))
2723
2724 if window_mode not in [e for e in WindowType]:
2725 raise ValueError("Only accepts values of [%s] but was '%s'" % ([e for e in
2726 WindowType],
2727 window_mode))
2728
2729 self.write("TWNDOW %s,%s" % (trace, window_mode))
2730
2731 video_average = Instrument.control(
2732 "VAVG?", "VAVG %d",
2733 """
2734 Control the video averaging function. Video averaging smooths the
2735 displayed trace without using a narrow bandwidth. 'video_average' sets the IF detector to
2736 sample mode (see the DET command) and smooths the trace by averaging successive traces
2737 with each other. If desired, you can change the detector mode during video averaging.
2738 Video averaging is available only for trace A, and trace A must be in clear-write mode for
2739 'video_average' to operate. After 'video_average' is executed, the number of sweeps that
2740 have been averaged appears at the top of the analyzer screen. Using video averaging
2741 allows you to view changes to the entire trace much faster than using narrow video
2742 filters. Narrow video filters require long sweep times, which may not be desired. Video
2743 averaging, though requiring more sweeps, uses faster sweep times; in some cases, it can
2744 produce a smooth trace as fast as a video filter.
2745
2746 Type: :code:`str, int`
2747 """,
2748 validator=strict_range,
2749 values=np.arange(1, 999),
2750 cast=int
2751 )
2752
2753 video_average_enabled = Instrument.setting(
2754 "VAVG %s",
2755 """
2756 Set the video averaging either active or inactive. See :attr:`video_average`
2757 """,
2758 map_values=True,
2759 values={True: "ON", False: "OFF"},
2760 validator=strict_discrete_set
2761 )
2762
2763 video_bandwidth = Instrument.control(
2764 "VB?", "VB %s",
2765 """
2766 Control the video bandwidth. This is normally a coupled function that
2767 is selected according to the ratio selected by the VBR command. (If no ratio is selected,
2768 a default ratio, 1.0, is used instead.) Video bandwidth filters (or smooths) post-detected
2769 video information. The bandwidth, which ranges from 1 Hz to 3 MHz, may also be selected
2770 manually. If the specified video bandwidth is less than 300 Hz and the resolution bandwidth
2771 is greater than or equal to 300 Hz, the IF detector is set to sample mode. Reducing the
2772 video bandwidth or increasing the number of video averages will usually smooth the trace
2773 by about as much for the same total measurement time. Reducing the video bandwidth to
2774 one-third or less of the resolution bandwidth is desirable when the number of video
2775 averages is above 25. For the case where the number of video averages is very large, and
2776 the video bandwidth is equal to the resolution bandwidth, internal mathematical limitations
2777 allow about 0.4 dB overresponse to noise on the logarithmic scale. The overresponse is
2778 negligible (less than 0.1 dB) for narrower video bandwidths.
2779
2780 Type: :code:`int`
2781 """,
2782 validator=joined_validators(strict_discrete_set, strict_range),
2783 values=[["AUTO", "MAN"], np.arange(1, 3e6)],
2784 cast=int,
2785 set_process=lambda v: v if isinstance(v, str) else f"{v} Hz"
2786 )
2787
2788 video_bandwidth_to_resolution_bandwidth = Instrument.control(
2789 "VBR?", "VBR %.3f",
2790 """
2791 Control the coupling ratio between the video bandwidth and the
2792 resolution bandwidth. Thus, when the resolution bandwidth is changed, the video bandwidth
2793 changes to satisfy the ratio. The ratio ranges from 0.003 to 3 in a 1, 3, 10 sequence. The
2794 default ratio is 1. When a new ratio is selected, the video bandwidth changes to satisfy the
2795 new ratio—the resolution bandwidth does not change value.
2796 """,
2797 validator=strict_range,
2798 values=np.arange(0.002, 0.10, 0.001)
2799 )
2800
2801 def view_trace(self, trace):
2802 """Display the current contents of the selected trace, but does not update
2803 the contents. View mode may be executed before a sweep is complete when :meth:`sweep_single`
2804 and :meth:`trigger_sweep` are not used.
2805
2806 :param trace: A representation of the trace, either from :class:`Trace` or
2807 use 'TRA' for Trace A or 'TRB' for Trace B
2808 :type trace: str
2809 :raises TypeError: Type isn't 'string'
2810 :raises ValueError: Value is 'TRA' nor 'TRB'
2811 """
2812 if not isinstance(trace, str):
2813 raise TypeError("Should be of type string but is '%s'" % type(trace))
2814
2815 if trace not in [e for e in Trace]:
2816 raise ValueError("Only accepts values of [%s] but was '%s'" % ([e for e in Trace],
2817 trace))
2818 self.write("VIEW " + trace)
2819
2820 video_trigger_level = Instrument.control(
2821 "VTL?", "VTL %.3f {amplitude_unit}",
2822 """
2823 Control the video trigger level when the trigger mode is set to VIDEO (refer
2824 to the :attr:`trigger_mode` command). A dashed line appears on the display to indicate the
2825 level. The default value is 0 dBm. Range -220 to 30.
2826
2827 Type: :code:`float`
2828 """,
2829 validator=strict_range,
2830 values=[-220, 30]
2831 )
2832
2833
2834 class HP8560A(HP856Xx):
2835 """Represents the HP 8560A Spectrum Analyzer and provides a high-level
2836 interface for interacting with the instrument.
2837
2838 .. code-block:: python
2839
2840 from pymeasure.instruments.hp import HP8560A
2841 from pymeasure.instruments.hp.hp856Xx import AmplitudeUnits
2842
2843 sa = HP8560A("GPIB::1")
2844
2845 sa.amplitude_unit = AmplitudeUnits.DBUV
2846 sa.start_frequency = 299.5e6
2847 sa.stop_frequency = 300.5e6
2848
2849 print(sa.marker_amplitude)
2850 """
2851
2852 # HP8560A is able to go up to 2.9 GHz
2853 MAX_FREQUENCY = 2.9e9
2854
2855 def __init__(self, adapter, name="Hewlett-Packard HP8560A", **kwargs):
2856 super().__init__(
2857 adapter,
2858 name,
2859 **kwargs,
2860 )
2861
2862 self.center_frequency_values = [0, self.MAX_FREQUENCY]
2863 self.start_frequency_values = [0, self.MAX_FREQUENCY]
2864 self.stop_frequency_values = [0, self.MAX_FREQUENCY]
2865 self.frequency_offset_values = [0, self.MAX_FREQUENCY]
2866 self.marker_frequency_values = [0, self.MAX_FREQUENCY]
2867 self.span_values = [["FULL", "ZERO"], [0, self.MAX_FREQUENCY]]
2868
2869 source_leveling_control = Instrument.control(
2870 "SRCALC?", "SRCALC %s",
2871 """
2872 Control if internal or external leveling is used with the
2873 built-in tracking generator.
2874 Takes either 'INT', 'EXT' or members of enumeration :class:`SourceLevelingControlMode`
2875
2876 Type: :code:`str`
2877
2878 .. code-block:: python
2879
2880 instr.preset()
2881 instr.sweep_single()
2882 instr.center_frequency = 300e6
2883 instr.span = 1e6
2884
2885 instr.source_power = -5
2886
2887 instr.trigger_sweep()
2888 instr.source_leveling_control = SourceLevelingControlMode.External
2889
2890 if ErrorCode(900) in instr.errors:
2891 print("UNLEVELED CONDITION. CHECK LEVELING LOOP.")
2892
2893 .. note::
2894 Only available with an HP 8560A Option 002.
2895 """,
2896 validator=strict_discrete_set,
2897 values=[e for e in SourceLevelingControlMode]
2898 )
2899
2900 tracking_adjust_coarse = Instrument.control(
2901 "SRCCRSTK?", "SRCCRSTK %d",
2902 """
2903 Control the coarse adjustment to the frequency of the built-in
2904 tracking-generator oscillator. Once enabled, this adjustment is made in
2905 digital-to-analogconverter (DAC) values from 0 to 255. For fine adjustment, refer to the
2906 :attr:`tracking_adjust_fine` command description.
2907
2908 Type: :code:`int`
2909
2910 .. note::
2911 Only available with an HP 8560A Option 002.
2912 """,
2913 validator=strict_range,
2914 values=[0, 255],
2915 cast=int
2916 )
2917
2918 tracking_adjust_fine = Instrument.control(
2919 "SRCFINTK?", "SRCFINTK %d",
2920 """
2921 Control the fine adjustment of the frequency of the built-in
2922 tracking-generator oscillator. Once enabled, this adjustment is made in
2923 digital-to-analogconverter (DAC) values from 0 to 255. For coarse adjustment, refer to
2924 the :attr:`tracking_adjust_coarse` command description.
2925
2926 Type: :code:`int`
2927
2928 .. note::
2929 Only available with an HP 8560A Option 002.
2930 """,
2931 validator=strict_range,
2932 values=[0, 255],
2933 cast=int
2934 )
2935
2936 source_power_offset = Instrument.control(
2937 "SRCPOFS?", "SRCPOFS %g {amplitude_unit}",
2938 """
2939 Control the offset of the displayed power of the built-in tracking generator so that
2940 it is equal to the measured power at the input of the spectrum analyzer. This function may
2941 be used to take into account system losses (for example, cable loss) or gains (for example,
2942 preamplifier gain) reflecting the actual power delivered to the device under test.
2943
2944 Type: :code:`int`
2945
2946 .. note::
2947 Only available with an HP 8560A Option 002.
2948 """,
2949 validator=strict_range,
2950 values=[-100, 100],
2951 cast=int
2952 )
2953
2954 source_power_step = Instrument.control(
2955 "SRCPSTP?", "SRCPSTP %.2f DB",
2956 """
2957 Control the step size of the source power level, source power offset, and
2958 power-sweep range functions. Range: 0.1 ... 12.75 DB with 0.05 steps.
2959
2960 Type: :code:`float`
2961
2962 .. note::
2963 Only available with an HP 8560A Option 002.
2964 """,
2965 validator=strict_range,
2966 values=np.arange(0.1, 12.75, 0.05)
2967 )
2968
2969 source_power_sweep = Instrument.control(
2970 "SRCPSWP?", "SRCPSWP %.2f DB",
2971 """
2972 Control the power-sweep function, where the
2973 output power of the tracking generator is swept over the power-sweep range chosen. The
2974 starting source power level is set using the :attr:`source_power` command. The output power
2975 of the tracking generator is swept according to the sweep rate of the spectrum analyzer.
2976
2977 Type: :code:`str, float`
2978
2979 .. note::
2980 Only available with an HP 8560A Option 002.
2981 """,
2982 validator=truncated_discrete_set,
2983 values=np.arange(0.1, 12.75, 0.05),
2984 )
2985
2986 source_power_sweep_enabled = Instrument.setting(
2987 "SRCPSWP %s",
2988 """
2989 Set the power sweep active or inactive. See :attr:`source_power_sweep`.
2990 """,
2991 map_values=True,
2992 values={True: "ON", False: "OFF"},
2993 validator=strict_discrete_set
2994 )
2995
2996 source_power = Instrument.control(
2997 "SRCPWR?", "SRCPWR %s",
2998 """
2999 Control the built-in tracking generator's output power.
3000
3001 Type: :code:`str, float`
3002
3003 .. note::
3004 Only available with an HP 8560A Option 002.
3005 """,
3006 validator=joined_validators(strict_discrete_set, truncated_discrete_set),
3007 values=[["OFF", "ON"], np.arange(-10, 2.8, 0.05)],
3008 set_process=lambda v: v if isinstance(v, str) else ("%.2f {amplitude_unit}" % v)
3009 )
3010
3011 source_power_enabled = Instrument.setting(
3012 "SRCPWR %s",
3013 """
3014 Set the built-in tracking generator on or off. See :attr:`source_power`
3015 """,
3016 map_values=True,
3017 values={True: "ON", False: "OFF"},
3018 validator=strict_discrete_set
3019 )
3020
3021 def activate_source_peak_tracking(self):
3022 """Activate a routine which automatically adjusts both the coarse and
3023 fine-tracking adjustments to obtain the peak response of the tracking
3024 generator on the spectrum-analyzer display. Tracking peak is not
3025 necessary for resolution bandwidths greater than or equal to 300 kHz. A
3026 thru connection should be made prior to peaking in order to ensure
3027 accuracy.
3028
3029 .. note::
3030 Only available with an HP 8560A Option 002.
3031 """
3032 self.write("SRCTKPK")
3033
3034
3035 class HP8561B(HP856Xx):
3036 """Represents the HP 8561B Spectrum Analyzer and provides a high-level
3037 interface for interacting with the instrument.
3038
3039 .. code-block:: python
3040
3041 from pymeasure.instruments.hp import 8561B
3042 from pymeasure.instruments.hp.hp856Xx import AmplitudeUnits
3043
3044 sa = HP8560A("GPIB::1")
3045
3046 sa.amplitude_unit = AmplitudeUnits.DBUV
3047 sa.start_frequency = 6.4e9
3048 sa.stop_frequency = 6.5e9
3049
3050 print(sa.marker_amplitude)
3051 """
3052
3053 # HP8561B is able to go up to 6.5 GHz
3054 MAX_FREQUENCY = 6.5e9
3055
3056 def __init__(self, adapter, name="Hewlett-Packard HP8561B", **kwargs):
3057 super().__init__(
3058 adapter,
3059 name,
3060 **kwargs,
3061 )
3062
3063 self.center_frequency_values = [0, self.MAX_FREQUENCY]
3064 self.start_frequency_values = [0, self.MAX_FREQUENCY]
3065 self.stop_frequency_values = [0, self.MAX_FREQUENCY]
3066 self.frequency_offset_values = [0, self.MAX_FREQUENCY]
3067 self.marker_frequency_values = [0, self.MAX_FREQUENCY]
3068 self.span_values = [["FULL", "ZERO"], [0, self.MAX_FREQUENCY]]
3069
3070 conversion_loss = Instrument.control(
3071 "CNVLOSS?", "CNVLOSS %s DB",
3072 """
3073 Control the compensation for losses outside the instrument when in external
3074 mixer mode (such as losses within connector cables, external mixers, etc.).
3075 'conversion_loss' specifies the mean conversion loss for the current harmonic band.
3076 In a full frequency band (such as band K), the mean conversion loss is defined as the
3077 minimum loss plus the maximum loss for that band divided by two.
3078 Adjusting for conversion loss allows the system to remain
3079 calibrated (that is, the displayed amplitude values have the conversion loss incorporated
3080 into them). The default value for any band is 30 dB. The spectrum analyzer must be in
3081 external-mixer mode in order for this command to work. When in internal-mixer mode,
3082 querying 'conversion_loss' returns a zero.
3083 """,
3084 validator=strict_range,
3085 values=[0, float("inf")]
3086 )
3087
3088 def set_fullband(self, band):
3089 """Select a commonly-used, external-mixer frequency band, as shown in
3090 the table. The harmonic lock function :attr:`harmonic_number_lock` is
3091 also set; this locks the harmonic of the chosen band. External-mixing
3092 functions are not available with an HP 8560A Option 002. Takes
3093 frequency band letter as string.
3094
3095 .. list-table:: Title
3096 :widths: 25 25 25 25
3097 :header-rows: 1
3098
3099 * - Frequency Band
3100 - Frequency Range (GHz)
3101 - Mixing Harmonic
3102 - Conversion Loss
3103 * - K
3104 - 18.0 — 26.5
3105 - 6
3106 - 30 dB
3107 * - A
3108 - 26.5 — 40.0
3109 - 8
3110 - 30 dB
3111 * - Q
3112 - 33.0—50.0
3113 - 10
3114 - 30 dB
3115 * - U
3116 - 40.0—60.0
3117 - 10
3118 - 30 dB
3119 * - V
3120 - 50.0—75.0
3121 - 14
3122 - 30 dB
3123 * - E
3124 - 60.0—-90.0
3125 - 16
3126 - 30 dB
3127 * - W
3128 - 75.0—110.0
3129 - 18
3130 - 30 dB
3131 * - F
3132 - 90.0—140.0
3133 - 24
3134 - 30 dB
3135 * - D
3136 - 110.0—170.0
3137 - 30
3138 - 30 dB
3139 * - G
3140 - 140.0—220.0
3141 - 36
3142 - 30 dB
3143 * - Y
3144 - 170.0—260.0
3145 - 44
3146 - 30 dB
3147 * - J
3148 - 220.0—325.0
3149 - 54
3150 - 30 dB
3151 """
3152 frequency_mapping = {
3153 "K": [18e9, 26.5e9],
3154 "A": [26.5e9, 40e9],
3155 "Q": [33e9, 50e9],
3156 "U": [40e9, 60e9],
3157 "V": [50e9, 75e9],
3158 "E": [60e9, 90e9],
3159 "W": [75e9, 110e9],
3160 "F": [90e9, 140e9],
3161 "D": [110e9, 170e9],
3162 "G": [140e9, 220e9],
3163 "Y": [170e9, 260e9],
3164 "J": [220e9, 325e9],
3165 }
3166
3167 if not isinstance(band, str):
3168 raise TypeError("Frequency band should be of type string but is '%s'" % type(band))
3169
3170 if band not in frequency_mapping.keys():
3171 raise ValueError("Should be one of the available bands but is '%s'" % band)
3172
3173 self.center_frequency_values = frequency_mapping[band]
3174 self.start_frequency_values = frequency_mapping[band]
3175 self.stop_frequency_values = frequency_mapping[band]
3176
3177 self.write("FULLBAND %s" % band)
3178
3179 harmonic_number_lock = Instrument.control(
3180 "HNLOCK?", "HNLOCK %d",
3181 """
3182 Control the lock to a chosen harmonic so only that harmonic is used to sweep
3183 an external frequency band. To select a frequency band, use the 'fullband' command; it
3184 selects an appropriate harmonic for the desired band. To change the harmonic number, use
3185 'harmonic_number_lock'.
3186 Note that 'harmonic_number_lock' also works in internal-mixing modes.
3187 Once 'fullband' or 'harmonic_number_lock' are set, only center frequencies and spans that
3188 fall within the frequency band of the current harmonic may be entered. When the
3189 'set_full_span' command is activated, the span is limited to the frequency band of the
3190 selected harmonic.
3191 """,
3192 validator=strict_range,
3193 values=[1, 54],
3194 cast=int
3195 )
3196
3197 harmonic_number_lock_enabled = Instrument.setting(
3198 "HNLOCK %s",
3199 """
3200 Set the harmonic number locking active or inactive. See :attr:`harmonic_number_lock`.
3201 """,
3202 map_values=True,
3203 values={True: "ON", False: "OFF"},
3204 validator=strict_discrete_set
3205 )
3206
3207 def unlock_harmonic_number(self):
3208 """Unlock the harmonic number, allowing you to select frequencies and
3209 spans outside the range of the locked harmonic number.
3210
3211 Also, when HNUNLK is executed, more than one harmonic can then
3212 be used to sweep across a desired span. For example, sweep a
3213 span from 18 GHz to 40 GHz. In this case, the analyzer will
3214 automatically sweep first using 6—, then using 8—.
3215 """
3216 self.write("HUNLK")
3217
3218 def set_signal_identification_to_center_frequency(self):
3219 """Set the center frequency to the frequency obtained from the command
3220 SIGID.
3221
3222 SIGID must be in AUTO mode and have found a valid result for
3223 this command to execute properly. Use SIGID on signals greater
3224 than 18 GHz {i.e., in external mixing mode). SIGID and IDCF may
3225 also be used on signals less than 6.5 GHz in an HP 8561B.
3226 """
3227 self.write("IDCF")
3228
3229 signal_identification_frequency = Instrument.measurement(
3230 "IDFREQ?",
3231 """
3232 Measure the frequency of the last identified signal. After an instrument preset or an
3233 invalid signal identification, IDFREQ returns a “0”.
3234 """
3235 )
3236
3237 mixer_bias = Instrument.control(
3238 "MBIAS?", "MBIAS %.3f MA",
3239 """
3240 Set the bias for an external mixer that requires diode bias for efficient
3241 mixer operation. The bias, which is provided on the center conductor of the IF input, is
3242 activated when MBIAS is executed. A "+" or "—" appears on the left edge of the spectrum
3243 analyzer display, indicating that positive or negative bias is on. When the bias is
3244 turned off, MBIAS is set to 0. Default units are in milliamps.
3245 """,
3246 validator=strict_range,
3247 values=[float(-10E3), int(10E3)],
3248 cast=float
3249 )
3250
3251 mixer_bias_enabled = Instrument.setting(
3252 "MBIAS %s",
3253 """
3254 Control the bias for an external mixer. See :attr:`mixer_bias`.
3255 """,
3256 map_values=True,
3257 values={True: "ON", False: "OFF"},
3258 validator=strict_discrete_set
3259 )
3260
3261 mixer_mode = Instrument.control(
3262 "MXRMODE?", "MXRMODE %s",
3263 """
3264 Control the mixer mode. Select either the internal mixer
3265 or supply an external mixer. Takes enum 'MixerMode' or string 'INT', 'EXT'
3266 """,
3267 validator=strict_discrete_set,
3268 values=[e for e in MixerMode]
3269 )
3270
3271 def peak_preselector(self):
3272 """Peaks the preselector in the HP 8561B Spectrum Analyzer.
3273
3274 Make sure the entire frequency span is in high band, set the
3275 desired trace to clear-write mode, place a marker on a desired
3276 signal, then execute PP. The peaking routine zooms to zero span,
3277 peaks the preselector tracking, then returns to the original
3278 position. To read the new preselector peaking number, use the
3279 PSDAC command. Commands following PP are not executed until
3280 after the analyzer has finished peaking the preselector.
3281 """
3282 self.write("PP")
3283
3284 preselector_dac_number = Instrument.control(
3285 "PSDAC?", "PSDAC %d",
3286 """
3287 Control the preselector peak DAC number. For use with an
3288 HP 8561B Spectrum Analyzer.
3289
3290 Type: :code:`int`
3291 """,
3292 cast=int,
3293 validator=strict_range,
3294 values=[0, 255]
3295 )
3296
3297 signal_identification = Instrument.control(
3298 "SIGID?", "SIGID %s",
3299 """
3300 Control the signal identification for identifying signals for the external
3301 mixing frequency bands.
3302 Two signal identification methods are available. AUTO employs the image response method
3303 for locating correct mixer responses. Place a marker on the desired signal, then activate
3304 signal_identification = 'AUTO'. The frequency of a correct response appears in the active
3305 function block. Use this mode before executing the
3306 :meth:`signal_identification_to_center_frequency` command. The second method of signal
3307 identification, 'MAN', shifts responses both horizontally and vertically. A correct
3308 response is shifted horizontally by less than 80 kHz. To ensure accuracy in MAN mode,
3309 limit the frequency span to less than 20 MHz.
3310 Where True = manual mode is active and False = auto mode is active or
3311 'signal_identification' is off.
3312 """,
3313 map_values=True,
3314 validator=strict_discrete_set,