Debian Codegraph @

tests/qchem6/README.md

raw
1 # Q-Chem 6 test inputs
2
3 These `.qcin` files mirror the Gaussian fixtures in `../g16/` so the same
4 molecule + level-of-theory combinations can be run through Q-Chem 6 and
5 compared. Filenames are kept identical (only the extension differs) so each
6 Q-Chem input pairs with its g16 counterpart by name:
7
8 ```
9 g16/01a_water_hf_freq.com ↔ qchem6/01a_water_hf_freq.qcin
10 ```
11
12 ## How to run
13
14 Default: `qchem 01a_water_hf_freq.qcin 01a_water_hf_freq.out`. Multi-job
15 inputs (those that contain `@@@`) chain an Opt followed by a Freq in a
16 single submission — Q-Chem's standard pattern for opt+freq jobs. Memory and
17 parallelism are intentionally **not** set in the input; configure them at
18 submission time (`qchem -nt 16 …`, or via `QC_PARALLEL_NPROC`).
19
20 ## Conventions
21
22 | Gaussian feature | Q-Chem encoding |
23 |------------------|-----------------|
24 | `Opt Freq` (single job) | `JOBTYPE = opt` then `@@@` then `JOBTYPE = freq` (geometry read) |
25 | `Opt=(TS,CalcFC,…)` | `JOBTYPE = ts` (Q-Chem computes initial Hessian by default) |
26 | `Freq=(Anharmonic)` | `ANHAR = true` in `$rem` |
27 | `Freq=(Temperature=…,Pressure=…)` | Run at default T/P; pass `--temperature` and `--conc` to GoodVibes |
28 | `SCRF=(CPCM,Solvent=X)` | `SOLVENT_METHOD = pcm` + `$pcm` (THEORY = cpcm) + `$solvent` (Dielectric) |
29 | `SCRF=(SMD,Solvent=X)` | `SOLVENT_METHOD = SMD` + `$smx` (solvent name) |
30 | `EmpiricalDispersion=GD3BJ` | `DFT_D = d3_bj` |
31 | `EmpiricalDispersion=GD3` | `DFT_D = d3_zero` |
32 | `Counterpoise=2` | `JOBTYPE = bsse` + `--` fragment separators in `$molecule` |
33 | `NMR=GIAO` | `JOBTYPE = nmr` |
34 | `td=(nstates=N,root=K)` | `CIS_N_ROOTS = N`, `CIS_STATE_DERIV = K` |
35 | `Gen` mixed basis + `ECP` | `BASIS = gen`, `ECP = gen`, `$basis` and `$ecp` blocks |
36 | Multi-step `--Link1--` | `@@@` separator with `READ` for the molecule block |
37
38 ## Skipped fixtures
39
40 Two g16 fixtures have no clean Q-Chem 6 equivalent:
41
42 - `15_methanol_oniom_qmmm.com` — ONIOM (B3LYP:PM6) two-layer QM/MM. Q-Chem
43 uses a different QM/MM machinery (PEqM / ChemShell) that doesn't read
44 layer tags from a route line.
45 - `21_naphthalene_pm7_semiempirical.com` — Q-Chem doesn't ship PM7. The
46 closest analogues (PM3, AM1) are not direct surrogates for thermochemistry
47 benchmarking.
48
49 ## Caveats
50
51 - These inputs were translated from Gaussian route lines; please run a few
52 on your Q-Chem 6 install to spot-check. Report any syntax issues.
53 - `THERMO_TEMP` / `THERMO_PRES` are not set on opt+freq jobs that used a
54 non-default T/P in g16 (`02_ethane`, `40_n2o`). Use GoodVibes
55 `--temperature` / `--conc` to apply those at thermo time.
56 - `Freq=NoRaman` has no behavioural counterpart in Q-Chem; Q-Chem doesn't
57 compute Raman intensities by default.
58 - `12_water_anharmonic_vpt2` and `23_cs2_linear_anharmonic` use `ANHAR = true`;
59 consult the Q-Chem 6 manual for additional VPT2-specific REM variables
60 (e.g. `VPT2_*`) if your install needs them.
61 - Error fixtures `51-60` are recreated to trigger Q-Chem-equivalent failure
62 modes. The exact error message will differ from Gaussian.