1 check_hpasm Nagios Plugin README
2 ---------------------
3
4 This plugin checks the hardware health of HP Proliant servers with the
5 hpasm software installed. It uses the hpasmcli command to acquire the
6 condition of the system's critical components like cpus, power supplies,
7 temperatures, fans and memory modules. Newer versions also use SNMP.
8
9 * For instructions on installing this plugin for use with Nagios,
10 see below. In addition, generic instructions for the GNU toolchain
11 can be found in the INSTALL file.
12
13 * For major changes between releases, read the CHANGES file.
14
15 * For information on detailed changes that have been made,
16 read the Changelog file.
17
18 * This plugins is self documenting. All plugins that comply with
19 the basic guidelines for development will provide detailed help when
20 invoked with the '-h' or '--help' options.
21
22 You can check for the latest plugin at:
23 http://www.consol.de/opensource/nagios/check-hpasm
24
25 Send mail to [email protected] for assistance.
26 Please include the OS type and version that you are using.
27 Also, run the plugin with the '-v' option and provide the resulting
28 version information. Of course, there may be additional diagnostic information
29 required as well. Use good judgment.
30
31
32 How to "compile" the check_hpasm script.
33 --------------------------------------------------------
34
35 1) Run the configure script to initialize variables and create a Makefile, etc.
36
37 ./configure --prefix=BASEDIRECTORY --with-nagios-user=SOMEUSER --with-nagios-group=SOMEGROUP --with-perl=PATH_TO_PERL --with-noinst-level=LEVEL --with-degrees=UNIT --with-perfdata --with-hpacucli
38
39 a) Replace BASEDIRECTORY with the path of the directory under which Nagios
40 is installed (default is '/usr/local/nagios')
41 b) Replace SOMEUSER with the name of a user on your system that will be
42 assigned permissions to the installed plugins (default is 'nagios')
43 c) Replace SOMEGRP with the name of a group on your system that will be
44 assigned permissions to the installed plugins (default is 'nagios')
45 d) Replace PATH_TO_PERL with the path where a perl binary can be found.
46 Besides the system wide perl you might have installed a private perl
47 just for the nagios plugins (default is the perl in your path).
48 e) Replace LEVEL with one of ok, warning, critical or unknown.
49 If the required hpasm-rpm is not installed, the check_hpasm plugin
50 will exit with the level specified. If you chose ok, the message
51 will say "ok - .... hpasm is not installed". This is different from
52 the "ok - hardware working fine" if hpasm was found.
53 The default is to treat a missing hpasm package as ok.
54 f) Replace UNIT with one of celsius or fahrenheit. The hpasmcli "show temp"
55 prints temperatures both in units of celsius and fahrenheit. With the
56 --with-degrees option you can decide which units will be shown in an
57 alarm message.
58 The default is "celsius".
59 g) You can tell check_hpasm to output performance data by default if
60 you call configure with the --enable-perfdata option.
61 h) You can tell check_hpasm to check the raid status with the hpacucli command
62 if you call configure with the --enable-hpacucli option.
63 You need the hpacucli rpm.
64
65 2) "Compile" the plugin with the following command:
66
67 make
68
69 This will produce a "check_hpasm" script. You will also find
70 a "check_hpasm.pl" which you better ignore. It is the base for
71 the compilation filled with placeholders. These will be replaced during
72 the make process.
73
74
75 3) Install the compiled plugin script with the following command:
76
77 make install
78
79 The installation procedure will attempt to place the plugin in a
80 'libexec/' subdirectory in the base directory you specified with
81 the --prefix argument to the configure script.
82
83
84 4) Verify that your configuration files for Nagios contains
85 the correct paths to the new plugin.
86
87
88 5) Add this line to /etc/sudoers:
89 nagios ALL=NOPASSWD: /sbin/hpasmcli
90 or ths, if you also installed the hpacu package
91 nagios ALL=NOPASSWD: /sbin/hpasmcli, /usr/sbin/hpacucli
92
93
94
95 Command line parameters
96 -----------------------
97
98 -v, --verbose
99 Increased verbosity will print how check_hpasm communicates with the
100 hpasm daemon and which values were acquired.
101
102 -t, --timeout
103 The number of seconds after which the plugin will abort.
104
105 -b, --blacklist
106 If some components of your system are missing (mostly the secondary
107 power supply bay is empty) and you tolerate this, then blacklist the
108 missing/failed component to avoid false alarms.
109 The value for this option is a slash-separated list of components to
110 ignore.
111 Example: -b p:1,2/f:2/t:3,4/c:1/d:0-1,0-2
112 means: ignore power supplies #1 and #2, fan #2, temperature #3 and #4,
113 cpu #1 and dimms #1 and #2 in cartridge #0.
114
115 -c, --customthresh
116 Override the machine-default temperature thresholds.
117 Example: -c 1:60/4:80/5:50
118 Sets limit for temperature 1 to 60 degrees, temperature 4 to 80 degrees
119 and temperature 5 to 50 degrees. You get the consecutive numbers by
120 calling check_hpasm -v
121 ...
122 checking temperatures
123 1 processor_zone temperature is 46 (62 max)
124 2 cpu#1 temperature is 43 (73 max)
125 3 i/o_zone temperature is 54 (68 max)
126 4 cpu#2 temperature is 46 (73 max)
127 5 power_supply_bay temperature is 38 (55 max)
128
129 -p, --perfdata
130 Add performance data to the output even if you did not compile check_hpasm
131 with --with-perfdata in step 1.
132
133
134
135 SNMP and Memory Modules
136 -----------------------
137 Older hardware does not always show valuable information when queried for
138 the health of memory modules. Maybe it's because older modules do not support
139 error checking at all.
140
141
142 1. no cpqHeResMemModule
143 ---------------------------------------------------------------------------
144
145 2. collapsed cpqHeResMemModule
146 ---------------------------------------------------------------------------
147
148 Some (older) systems do not support the cpqHeResMemModuleEntry table.
149 Either there is no oid with 1.3.6.1.4.1.232.6.2.14.11.1 at all
150 or there is a single oid like
151
152 Example:
153 iso.3.6.1.4.1.232.2.2.4.5.1.3.0.1 = INTEGER: 524288
154 iso.3.6.1.4.1.232.2.2.4.5.1.3.0.2 = INTEGER: 262144
155 iso.3.6.1.4.1.232.2.2.4.5.1.3.0.3 = INTEGER: 0
156 iso.3.6.1.4.1.232.2.2.4.5.1.3.0.4 = INTEGER: 524288
157 iso.3.6.1.4.1.232.2.2.4.5.1.3.0.5 = INTEGER: 262144
158 iso.3.6.1.4.1.232.2.2.4.5.1.3.0.6 = INTEGER: 0
159
160 ^-- module number
161 ^-- cartridge number (0 = system board)
162 ^-- size
163
164 iso.3.6.1.4.1.232.6.2.14.11.1.1.0.6 = INTEGER: 0
165
166 I compared 300 systems and found out that with
167 1.3.6.1.4.1.232.6.2.14.11.1.<no1>.<no2>.<no3> = <no4>
168 no1 is always 1
169 no2 is always 0
170 no3 is the number of memory slots (including the empty ones).
171 no4 is always 0. It is probably the health status of the
172 overall memory subsystem. I don't know.
173 I will implement 0 = ok, not 0 = ask compaq
174
175 cpqSiMemECCStatus provides no usable information. All my test systems
176 showed 0 which is an undocumented value.
177
178 function get_size(cpqHeResMemModuleEntry) will return 1.
179
180 3. cpqHeResMemModule containing crap
181 ---------------------------------------------------------------------------
182
183 grepping for cpqSiMemBoardSize shows 4 modules
184 iso.3.6.1.4.1.232.2.2.4.5.1.3.0.1 = INTEGER: 262144
185 iso.3.6.1.4.1.232.2.2.4.5.1.3.0.2 = INTEGER: 262144
186 iso.3.6.1.4.1.232.2.2.4.5.1.3.0.3 = INTEGER: 0
187 iso.3.6.1.4.1.232.2.2.4.5.1.3.0.4 = INTEGER: 262144
188 iso.3.6.1.4.1.232.2.2.4.5.1.3.0.5 = INTEGER: 262144
189 iso.3.6.1.4.1.232.2.2.4.5.1.3.0.6 = INTEGER: 0
190
191 grepping for cpqHeResMemEntry shows one module with zero values
192 iso.3.6.1.4.1.232.6.2.14.11.1.1.0.0 = INTEGER: 0
193 iso.3.6.1.4.1.232.6.2.14.11.1.2.0.0 = INTEGER: 0
194 iso.3.6.1.4.1.232.6.2.14.11.1.3.0.0 = ""
195 iso.3.6.1.4.1.232.6.2.14.11.1.4.0.0 = INTEGER: 0
196 iso.3.6.1.4.1.232.6.2.14.11.1.5.0.0 = INTEGER: 0
197 iso.3.6.1.4.1.232.6.2.14.11.1.6.0.0 = Hex-STRING: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
198
199
200 4. cpqHeResMemModuleEntry and cpqSiMemModuleEntry use different table indexes
201 ---------------------------------------------------------------------------
202
203 cpqSiMemBoardIndex 1.3.6.1.4.1.232.2.2.4.5.1.1
204 cpqSiMemModuleIndex 1.3.6.1.4.1.232.2.2.4.5.1.2
205
206 cpqHeResMemBoardIndex 1.3.6.1.4.1.232.6.2.14.11.1.1
207 cpqHeResMemModuleIndex 1.3.6.1.4.1.232.6.2.14.11.1.2
208
209
210 cpqSiMemBoardIndex
211 SNMPv2-SMI::enterprises.232.2.2.4.5.1.1.0.1 = INTEGER: 0
212 SNMPv2-SMI::enterprises.232.2.2.4.5.1.1.0.2 = INTEGER: 0
213 SNMPv2-SMI::enterprises.232.2.2.4.5.1.1.0.3 = INTEGER: 0
214 SNMPv2-SMI::enterprises.232.2.2.4.5.1.1.0.4 = INTEGER: 0
215 SNMPv2-SMI::enterprises.232.2.2.4.5.1.1.0.5 = INTEGER: 0
216 SNMPv2-SMI::enterprises.232.2.2.4.5.1.1.0.6 = INTEGER: 0
217
218 cpqHeResMemBoardIndex
219 SNMPv2-SMI::enterprises.232.6.2.14.11.1.1.1.1 = INTEGER: 0
220 SNMPv2-SMI::enterprises.232.6.2.14.11.1.1.1.2 = INTEGER: 0
221 SNMPv2-SMI::enterprises.232.6.2.14.11.1.1.1.3 = INTEGER: 0
222 SNMPv2-SMI::enterprises.232.6.2.14.11.1.1.1.4 = INTEGER: 0
223 SNMPv2-SMI::enterprises.232.6.2.14.11.1.1.1.5 = INTEGER: 0
224 SNMPv2-SMI::enterprises.232.6.2.14.11.1.1.1.6 = INTEGER: 0
225
226 It is not possible to use the SNMP-table-indices to identify the
227 corresponding he-entry. Matching is done with nested loops.
228
229 5. even worse: cpqHeResMemBoardIndex and cpqSiMemBoardIndex don't match
230 ---------------------------------------------------------------------------
231
232 cpqSiMemBoardIndex
233 iso.3.6.1.4.1.232.2.2.4.5.1.1.1.1 = INTEGER: 1
234 iso.3.6.1.4.1.232.2.2.4.5.1.1.1.2 = INTEGER: 1
235 iso.3.6.1.4.1.232.2.2.4.5.1.1.1.3 = INTEGER: 1
236 iso.3.6.1.4.1.232.2.2.4.5.1.1.1.4 = INTEGER: 1
237 iso.3.6.1.4.1.232.2.2.4.5.1.1.1.5 = INTEGER: 1
238 iso.3.6.1.4.1.232.2.2.4.5.1.1.1.6 = INTEGER: 1
239 iso.3.6.1.4.1.232.2.2.4.5.1.1.1.7 = INTEGER: 1
240 iso.3.6.1.4.1.232.2.2.4.5.1.1.1.8 = INTEGER: 1
241 iso.3.6.1.4.1.232.2.2.4.5.1.1.2.1 = INTEGER: 2
242 iso.3.6.1.4.1.232.2.2.4.5.1.1.2.2 = INTEGER: 2
243 iso.3.6.1.4.1.232.2.2.4.5.1.1.2.3 = INTEGER: 2
244 iso.3.6.1.4.1.232.2.2.4.5.1.1.2.4 = INTEGER: 2
245 iso.3.6.1.4.1.232.2.2.4.5.1.1.2.5 = INTEGER: 2
246 iso.3.6.1.4.1.232.2.2.4.5.1.1.2.6 = INTEGER: 2
247 iso.3.6.1.4.1.232.2.2.4.5.1.1.2.7 = INTEGER: 2
248 iso.3.6.1.4.1.232.2.2.4.5.1.1.2.8 = INTEGER: 2
249 iso.3.6.1.4.1.232.2.2.4.5.1.1.3.1 = INTEGER: 3
250
251 cpqHeResMemBoardIndex
252 iso.3.6.1.4.1.232.6.2.14.11.1.1.0.1 = INTEGER: 0
253 iso.3.6.1.4.1.232.6.2.14.11.1.1.0.2 = INTEGER: 0
254 iso.3.6.1.4.1.232.6.2.14.11.1.1.0.3 = INTEGER: 0
255 iso.3.6.1.4.1.232.6.2.14.11.1.1.0.4 = INTEGER: 0
256 iso.3.6.1.4.1.232.6.2.14.11.1.1.0.5 = INTEGER: 0
257 iso.3.6.1.4.1.232.6.2.14.11.1.1.0.6 = INTEGER: 0
258 iso.3.6.1.4.1.232.6.2.14.11.1.1.0.7 = INTEGER: 0
259 iso.3.6.1.4.1.232.6.2.14.11.1.1.0.8 = INTEGER: 0
260 iso.3.6.1.4.1.232.6.2.14.11.1.1.1.1 = INTEGER: 1
261 iso.3.6.1.4.1.232.6.2.14.11.1.1.1.2 = INTEGER: 1
262 iso.3.6.1.4.1.232.6.2.14.11.1.1.1.3 = INTEGER: 1
263 iso.3.6.1.4.1.232.6.2.14.11.1.1.1.4 = INTEGER: 1
264 iso.3.6.1.4.1.232.6.2.14.11.1.1.1.5 = INTEGER: 1
265 iso.3.6.1.4.1.232.6.2.14.11.1.1.1.6 = INTEGER: 1
266 iso.3.6.1.4.1.232.6.2.14.11.1.1.1.7 = INTEGER: 1
267 iso.3.6.1.4.1.232.6.2.14.11.1.1.1.8 = INTEGER: 1
268 iso.3.6.1.4.1.232.6.2.14.11.1.1.2.1 = INTEGER: 2
269
270
271 Redundant fans
272 -----------------------
273 I saw one old server which had only half of the possible fans installed.
274
275 Fan# 1 2 3 4 5 6
276
277 cpqHeFltTolFanPresent yes no yes no yes no
278 cpqHeFltTolFanRedundant no no no no no no
279 cpqHeFltTolFanRedundantPartner 2 1 4 3 6 5
280 cpqHeFltTolFanCondition ok other ok other ok other
281 cpqHeFltTolFanLocation cpu cpu cpu cpu io io
282
283 Normally this would result in
284 ...
285 fan #1 (cpu) is not redundant
286 fan #2 (cpu) is not redundant
287 fan #3 (cpu) is not redundant
288 fan #4 (cpu) is not redundant
289 fan #5 (ioboard) is not redundant
290 fan #6 (ioboard) is not redundant
291 WARNING - fan #1 (cpu) is not redundant, fan #2 (cpu) is not redundant, fan #3 (cpu) is not redundant, fan #4 (cpu) is not redundant, fan #5 (ioboard) is not redundant, fan #6 (ioboard) is not redundant
292
293 However it was the server's owner decision not to install fan pairs but only one fan per location, so for him this is a false alert.
294
295 By using --ignore-fan-redundancy check_hpasm only looks at the cpqHeFltTolFanCondition and ignores dependencies between two fans, so the result is:
296
297 fan 1 speed is normal, pctmax is 50%, location is cpu, redundance is no, partner is 2
298 fan 3 speed is normal, pctmax is 50%, location is cpu, redundance is no, partner is 4
299 fan 5 speed is normal, pctmax is 50%, location is ioboard, redundance is no, partner is 6
300 OK - System: 'proliant ml370 g3', ...
301
302
303 A snmp forwarding trick
304 -----------------------
305 local - where check_hpasm runs
306 remote - where a proliant can be reached
307 proliant - where the snmp agent runs
308
309 remote:
310 ssh -R6667:localhost:6667 local
311 socat tcp4-listen:6667,reuseaddr,fork UDP:proliant:161
312
313 local:
314 socat udp4-listen:161,reuseaddr,fork tcp:localhost:6667
315 check_hpasm --hostname 127.0.0.1
316
317
318 Sample data from real machines
319 ------------------------------
320
321 hpasmcli=$(which hpasmcli)
322 hpacucli=$(which hpacucli)
323 for i in server powersupply fans temp dimm
324 do
325 $hpasmcli -s "show $i" | while read line
326 do
327 printf "%s %s\n" $i "$line"
328 done
329 done
330 if [ -x "$hpacucli" ]; then
331 for i in config status
332 do
333 $hpacucli ctrl all show $i | while read line
334 do
335 printf "%s %s\n" $i "$line"
336 done
337 done
338 fi
339
340 If you think check_hpasm is not working correctly, please run the above script
341 and send me the output. It's also helpful to see the output of snmpwalk
342 snmpwalk .... 1.3.6.1.4.1.232
343