Debian Codegraph @

mysql-test/suite/service_sys_var_registration/r/sys_var_service.result

raw
1 call mtr.add_suppression("duplicate variable name");
2 # Simple load test
3 INSTALL COMPONENT "file://component_test_sys_var_service";
4 # Testing integer and bool type variable
5 SELECT @@test_component.int_sys_var;
6 @@test_component.int_sys_var
7 8
8 SELECT @@global.test_component.int_sys_var;
9 @@global.test_component.int_sys_var
10 8
11 SELECT @@global.test_component.bool_sys_var;
12 @@global.test_component.bool_sys_var
13 1
14 SELECT @@test_component.int_sys_var, @@test_component.bool_sys_var;
15 @@test_component.int_sys_var @@test_component.bool_sys_var
16 8 1
17 SET test_component.bool_sys_var=1;
18 ERROR HY000: Variable 'test_component.bool_sys_var' is a GLOBAL variable and should be set with SET GLOBAL
19 SET GLOBAL test_component.int_sys_var=7;
20 SET GLOBAL test_component.int_sys_var=1234567;
21 Warnings:
22 Warning 1292 Truncated incorrect test_component.int_sys_var value: '1234567'
23 SELECT @@test_component.int_sys_var;
24 @@test_component.int_sys_var
25 1024
26 SET GLOBAL test_component.int_sys_var=-1;
27 Warnings:
28 Warning 1292 Truncated incorrect test_component.int_sys_var value: '-1'
29 SELECT @@test_component.int_sys_var;
30 @@test_component.int_sys_var
31 0
32 SET GLOBAL test_component.int_sys_var=1.25;
33 ERROR 42000: Incorrect argument type to variable 'test_component.int_sys_var'
34 SET GLOBAL test_component.int_sys_var="hello";
35 ERROR 42000: Incorrect argument type to variable 'test_component.int_sys_var'
36 SET GLOBAL test_component.int_sys_var=123, test_component.bool_sys_var=0;
37 SELECT @@test_component.int_sys_var, @@test_component.bool_sys_var;
38 @@test_component.int_sys_var @@test_component.bool_sys_var
39 123 0
40 SET SESSION test_component.int_sys_var=123;
41 ERROR HY000: Variable 'test_component.int_sys_var' is a GLOBAL variable and should be set with SET GLOBAL
42 # Testing enum type variable
43 SELECT @@test_component.enum_sys_var;
44 @@test_component.enum_sys_var
45 MEDIUM
46 SET GLOBAL test_component.enum_sys_var="LOW";
47 SELECT @@test_component.enum_sys_var;
48 @@test_component.enum_sys_var
49 LOW
50 # Testing string type variable
51 SELECT @@test_component.str_sys_var;
52 @@test_component.str_sys_var
53 NULL
54 SET GLOBAL test_component.str_sys_var="dictionary.txt";
55 SELECT @@test_component.str_sys_var;
56 @@test_component.str_sys_var
57 dictionary.txt
58 SET GLOBAL test_component.str_sys_var=default;
59 SELECT @@test_component.str_sys_var;
60 @@test_component.str_sys_var
61 NULL
62 # Testing string type variable with default value
63 SELECT @@test_component.str_sys_var_default;
64 @@test_component.str_sys_var_default
65 default
66 SET GLOBAL test_component.str_sys_var_default="dictionary.txt";
67 SELECT @@test_component.str_sys_var_default;
68 @@test_component.str_sys_var_default
69 dictionary.txt
70 SET GLOBAL test_component.str_sys_var_default=something;
71 SELECT @@test_component.str_sys_var_default;
72 @@test_component.str_sys_var_default
73 something
74 # Testing unsigned integer type variable
75 SELECT @@test_component.uint_sys_var;
76 @@test_component.uint_sys_var
77 1024
78 SET GLOBAL test_component.uint_sys_var=12345678;
79 Warnings:
80 Warning 1292 Truncated incorrect test_component.uint_sys_var value: '12345678'
81 SELECT @@test_component.uint_sys_var;
82 @@test_component.uint_sys_var
83 10241024
84 SET GLOBAL test_component.uint_sys_var=default;
85 SELECT @@test_component.uint_sys_var;
86 @@test_component.uint_sys_var
87 1024
88 # Testing long type variable
89 SELECT @@test_component.long_sys_var;
90 @@test_component.long_sys_var
91 100
92 SET GLOBAL test_component.long_sys_var=1234567890;
93 Warnings:
94 Warning 1292 Truncated incorrect test_component.long_sys_var value: '1234567890'
95 SELECT @@test_component.long_sys_var;
96 @@test_component.long_sys_var
97 100
98 SET GLOBAL test_component.long_sys_var=default;
99 SELECT @@test_component.long_sys_var;
100 @@test_component.long_sys_var
101 100
102 # Testing unsigned long type variable
103 SELECT @@test_component.ulong_sys_var;
104 @@test_component.ulong_sys_var
105 8192
106 SET GLOBAL test_component.ulong_sys_var=1234567890;
107 Warnings:
108 Warning 1292 Truncated incorrect test_component.ulong_sys_var value: '1234567890'
109 SELECT @@test_component.ulong_sys_var;
110 @@test_component.ulong_sys_var
111 81928192
112 SET GLOBAL test_component.ulong_sys_var=default;
113 SELECT @@test_component.ulong_sys_var;
114 @@test_component.ulong_sys_var
115 8192
116 # Testing long long type variable
117 SELECT @@test_component.longlong_sys_var;
118 @@test_component.longlong_sys_var
119 8192
120 SET GLOBAL test_component.longlong_sys_var=1234567890;
121 SELECT @@test_component.longlong_sys_var;
122 @@test_component.longlong_sys_var
123 1234567890
124 SET GLOBAL test_component.longlong_sys_var=default;
125 SELECT @@test_component.longlong_sys_var;
126 @@test_component.longlong_sys_var
127 8192
128 # Testing unsigned long long type variable
129 SELECT @@test_component.ulonglong_sys_var;
130 @@test_component.ulonglong_sys_var
131 8192
132 SET GLOBAL test_component.ulonglong_sys_var=1234567890;
133 SELECT @@test_component.ulonglong_sys_var;
134 @@test_component.ulonglong_sys_var
135 1234567890
136 SET GLOBAL test_component.ulonglong_sys_var=default;
137 SELECT @@test_component.ulonglong_sys_var;
138 @@test_component.ulonglong_sys_var
139 8192
140 # Testing PERSIST for component system variables
141 SET PERSIST test_component.int_sys_var=7;
142 SELECT @@test_component.int_sys_var;
143 @@test_component.int_sys_var
144 7
145 SELECT * FROM performance_schema.persisted_variables;
146 VARIABLE_NAME VARIABLE_VALUE
147 test_component.int_sys_var 7
148 RESET PERSIST `test_component.int_sys_var`;
149 SELECT * FROM performance_schema.persisted_variables;
150 VARIABLE_NAME VARIABLE_VALUE
151 UNINSTALL COMPONENT "file://component_test_sys_var_service";
152 ########## test_component_sys_var_service.log:
153 test_component_sys_var init:
154 int register_variable failed.
155 variable value : 8
156 variable value : 1024
157 variable value : 100
158 variable value : 8192
159 variable value : 8192
160 variable value : 8192
161 variable value : ON
162 variable value : MEDIUM
163 variable value :
164 test_component_sys_var end of init:
165 test_component_sys_var deinit:
166 test_component_sys_var end of deinit:
167 #
168 # Coverage/regression tests for component & SP interations
169 #
170 CREATE PROCEDURE p(x VARCHAR(32)) SET @@GLOBAL.test_component.str_sys_var = x;
171 ERROR HY000: Unknown system variable 'test_component.str_sys_var'
172 CREATE PROCEDURE p() SELECT @@test_component.str_sys_var;
173 ERROR HY000: Unknown system variable 'test_component.str_sys_var'
174 INSTALL COMPONENT "file://component_test_sys_var_service";
175 CREATE PROCEDURE p1(x VARCHAR(32)) SET @@GLOBAL.test_component.str_sys_var = x;
176 CREATE PROCEDURE p2() SELECT @@test_component.str_sys_var;
177 CALL p2();
178 @@test_component.str_sys_var
179 NULL
180 CALL p1('test');
181 CALL p2();
182 @@test_component.str_sys_var
183 test
184 # Try to uninstall the component and fail with a warning since its busy
185 UNINSTALL COMPONENT "file://component_test_sys_var_service";
186 # Check that the component has been uninstalled
187 UNINSTALL COMPONENT "file://component_test_sys_var_service";
188 ERROR HY000: Component specified by URN 'file://component_test_sys_var_service' to unload has not been loaded before.
189 # Variable is not available any more: the component is uninstalling
190 CALL p1('test');
191 ERROR HY000: Unknown system variable 'test_component.str_sys_var'
192 CALL p2();
193 ERROR HY000: Unknown system variable 'test_component.str_sys_var'
194 # Check that the component is uninstalled
195 INSTALL COMPONENT "file://component_test_sys_var_service";
196 # Variable is available again
197 CALL p2();
198 @@test_component.str_sys_var
199 NULL
200 CALL p1('test');
201 CALL p2();
202 @@test_component.str_sys_var
203 test
204 UNINSTALL COMPONENT "file://component_test_sys_var_service";
205 DROP PROCEDURE p1;