| 1 |
// © 2020 and later: Unicode, Inc. and others. |
| 2 |
// License & terms of use: http://www.unicode.org/copyright.html |
| 3 |
|
| 4 |
#include "unicode/utypes.h" |
| 5 |
|
| 6 |
#if !UCONFIG_NO_FORMATTING |
| 7 |
#ifndef __UNITS_ROUTER_H__ |
| 8 |
#define __UNITS_ROUTER_H__ |
| 9 |
|
| 10 |
#include <limits> |
| 11 |
|
| 12 |
#include "cmemory.h" |
| 13 |
#include "measunit_impl.h" |
| 14 |
#include "unicode/locid.h" |
| 15 |
#include "unicode/measunit.h" |
| 16 |
#include "unicode/stringpiece.h" |
| 17 |
#include "unicode/uobject.h" |
| 18 |
#include "units_complexconverter.h" |
| 19 |
#include "units_data.h" |
| 20 |
|
| 21 |
U_NAMESPACE_BEGIN |
| 22 |
|
| 23 |
// Forward declarations |
| 24 |
class Measure; |
| 25 |
namespace number { |
| 26 |
class Precision; |
| 27 |
} |
| 28 |
|
| 29 |
namespace units { |
| 30 |
|
| 31 |
struct RouteResult : UMemory { |
| 32 |
// A list of measures: a single measure for single units, multiple measures |
| 33 |
// for mixed units. |
| 34 |
MaybeStackVector<Measure> measures; |
| 35 |
|
| 36 |
// The output unit for this RouteResult. This may be a MIXED unit - for |
| 37 |
// example: "yard-and-foot-and-inch", for which `measures` will have three |
| 38 |
// elements. |
| 39 |
MeasureUnitImpl outputUnit; |
| 40 |
|
| 41 |
RouteResult(MaybeStackVector<Measure> measures, MeasureUnitImpl outputUnit) |
| 42 |
: measures(std::move(measures)), outputUnit(std::move(outputUnit)) {} |
| 43 |
}; |
| 44 |
|
| 45 |
/** |
| 46 |
* Contains the complex unit converter and the limit which representing the smallest value that the |
| 47 |
* converter should accept. For example, if the converter is converting to `foot+inch` and the limit |
| 48 |
* equals 3.0, thus means the converter should not convert to a value less than `3.0 feet`. |
| 49 |
* |
| 50 |
* NOTE: |
| 51 |
* if the limit doest not has a value `i.e. (std::numeric_limits<double>::lowest())`, this mean there |
| 52 |
* is no limit for the converter. |
| 53 |
*/ |
| 54 |
struct ConverterPreference : UMemory { |
| 55 |
ComplexUnitsConverter converter; |
| 56 |
double limit; |
| 57 |
UnicodeString precision; |
| 58 |
|
| 59 |
// The output unit for this ConverterPreference. This may be a MIXED unit - |
| 60 |
// for example: "yard-and-foot-and-inch". |
| 61 |
MeasureUnitImpl targetUnit; |
| 62 |
|
| 63 |
// In case there is no limit, the limit will be -inf. |
| 64 |
ConverterPreference(const MeasureUnitImpl &source, const MeasureUnitImpl &complexTarget, |
| 65 |
UnicodeString precision, const ConversionRates &ratesInfo, UErrorCode &status) |
| 66 |
: ConverterPreference(source, complexTarget, std::numeric_limits<double>::lowest(), precision, |
| 67 |
ratesInfo, status) {} |
| 68 |
|
| 69 |
ConverterPreference(const MeasureUnitImpl &source, const MeasureUnitImpl &complexTarget, |
| 70 |
double limit, UnicodeString precision, const ConversionRates &ratesInfo, |
| 71 |
UErrorCode &status) |
| 72 |
: converter(source, complexTarget, ratesInfo, status), limit(limit), |
| 73 |
precision(std::move(precision)), targetUnit(complexTarget.copy(status)) {} |
| 74 |
}; |
| 75 |
|
| 76 |
} // namespace units |
| 77 |
|
| 78 |
// Export explicit template instantiations of MaybeStackArray, MemoryPool and |
| 79 |
// MaybeStackVector. This is required when building DLLs for Windows. (See |
| 80 |
// datefmt.h, collationiterator.h, erarules.h and others for similar examples.) |
| 81 |
// |
| 82 |
// Note: These need to be outside of the units namespace, or Clang will generate |
| 83 |
// a compile error. |
| 84 |
#if U_PF_WINDOWS <= U_PLATFORM && U_PLATFORM <= U_PF_CYGWIN |
| 85 |
template class U_I18N_API MaybeStackArray<units::ConverterPreference*, 8>; |
| 86 |
template class U_I18N_API MemoryPool<units::ConverterPreference, 8>; |
| 87 |
template class U_I18N_API MaybeStackVector<units::ConverterPreference, 8>; |
| 88 |
#endif |
| 89 |
|
| 90 |
namespace units { |
| 91 |
|
| 92 |
/** |
| 93 |
* `UnitsRouter` responsible for converting from a single unit (such as `meter` or `meter-per-second`) to |
| 94 |
* one of the complex units based on the limits. |
| 95 |
* For example: |
| 96 |
* if the input is `meter` and the output as following |
| 97 |
* {`foot+inch`, limit: 3.0} |
| 98 |
* {`inch` , limit: no value (-inf)} |
| 99 |
* Thus means if the input in `meter` is greater than or equal to `3.0 feet`, the output will be in |
| 100 |
* `foot+inch`, otherwise, the output will be in `inch`. |
| 101 |
* |
| 102 |
* NOTE: |
| 103 |
* the output units and the their limits MUST BE in order, for example, if the output units, from the |
| 104 |
* previous example, are the following: |
| 105 |
* {`inch` , limit: no value (-inf)} |
| 106 |
* {`foot+inch`, limit: 3.0} |
| 107 |
* IN THIS CASE THE OUTPUT WILL BE ALWAYS IN `inch`. |
| 108 |
* |
| 109 |
* NOTE: |
| 110 |
* the output units and their limits will be extracted from the units preferences database by knowing |
| 111 |
* the following: |
| 112 |
* - input unit |
| 113 |
* - locale |
| 114 |
* - usage |
| 115 |
* |
| 116 |
* DESIGN: |
| 117 |
* `UnitRouter` uses internally `ComplexUnitConverter` in order to convert the input units to the |
| 118 |
* desired complex units and to check the limit too. |
| 119 |
*/ |
| 120 |
class U_I18N_API UnitsRouter { |
| 121 |
public: |
| 122 |
UnitsRouter(StringPiece inputUnitIdentifier, const Locale &locale, StringPiece usage, |
| 123 |
UErrorCode &status); |
| 124 |
UnitsRouter(const MeasureUnit &inputUnit, const Locale &locale, StringPiece usage, |
| 125 |
UErrorCode &status); |
| 126 |
|
| 127 |
/** |
| 128 |
* Performs locale and usage sensitive unit conversion. |
| 129 |
* @param quantity The quantity to convert, expressed in terms of inputUnit. |
| 130 |
* @param rounder If not null, this RoundingImpl will be used to do rounding |
| 131 |
* on the converted value. If the rounder lacks an fPrecision, the |
| 132 |
* rounder will be modified to use the preferred precision for the usage |
| 133 |
* and locale preference, alternatively with the default precision. |
| 134 |
* @param status Receives status. |
| 135 |
*/ |
| 136 |
RouteResult route(double quantity, icu::number::impl::RoundingImpl *rounder, UErrorCode &status) const; |
| 137 |
|
| 138 |
/** |
| 139 |
* Returns the list of possible output units, i.e. the full set of |
| 140 |
* preferences, for the localized, usage-specific unit preferences. |
| 141 |
* |
| 142 |
* The returned pointer should be valid for the lifetime of the |
| 143 |
* UnitsRouter instance. |
| 144 |
*/ |
| 145 |
const MaybeStackVector<MeasureUnit> *getOutputUnits() const; |
| 146 |
|
| 147 |
private: |
| 148 |
// List of possible output units. TODO: converterPreferences_ now also has |
| 149 |
// this data available. Maybe drop outputUnits_ and have getOutputUnits |
| 150 |
// construct a the list from data in converterPreferences_ instead? |
| 151 |
MaybeStackVector<MeasureUnit> outputUnits_; |
| 152 |
|
| 153 |
MaybeStackVector<ConverterPreference> converterPreferences_; |
| 154 |
|
| 155 |
static number::Precision parseSkeletonToPrecision(icu::UnicodeString precisionSkeleton, |
| 156 |
UErrorCode &status); |
| 157 |
|
| 158 |
void init(const MeasureUnit &inputUnit, const Locale &locale, StringPiece usage, UErrorCode &status); |
| 159 |
}; |
| 160 |
|
| 161 |
} // namespace units |
| 162 |
U_NAMESPACE_END |
| 163 |
|
| 164 |
#endif //__UNITS_ROUTER_H__ |
| 165 |
|
| 166 |
#endif /* #if !UCONFIG_NO_FORMATTING */ |